Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 11 of 13

PanelMate Series 500 Getting Started User's Guide, pages 101 to 110

Pages 101 to 110 of 127

The original document is the PDF (3.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Cutler-Hammer 542VM PanelMate Series 500 and Eaton 542VM PanelMate Series 500

Page 101

The Communication Startup Reference Charts

A-6

Configuration Name PLC Type

ABDH485 Allen-Bradley SLC 500 family

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Allen-Bradley DH 485 A-B DH 485 1 2 485-2 19200 8 1 even 1 S:1/7 DH 485 port or 1747 AIC module AB33 or AB34

Configuration Name PLC Type

ABSLCSER Allen-Bradley SLC 5/03 or SLC 5/04

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Allen-Bradley Serial Allen-Bradley Serial (DF1 protocol) 1 2 RS232 19200 8 1 none 1 S:1/7 channel 0 AB36

Appendix

Page 102

Configuration Name PLC Type

ABSLCDHP Allen-Bradley SLC 5/04

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Allen-Bradley DH/DH+ Allen-Bradley Data Highway Plus I/O 2 N/A N/A N/A N/A N/A 1 S:1/7 channel 1 N/A (A-B 1770-CD twinaxial, or equivalent)

Configuration Name PLC Type

ABMICRO Allen-Bradley Micrologix

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Allen-Bradley Serial Allen-Bradley Serial (DF1 protocol) 1 2 RS 232 9600 8 1 none 1 S:1/7 programming port N/A (A-B 1761-CBL-PM02 cable)

Appendix

A-7

Page 103

A-8

Configuration Name PLC Type

ABSER232 Allen-Bradley PLC 5 family

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Allen-Bradley Serial Allen-Bradley Serial (DF1 protocol) 1 2 RS 232 19200 8 1 none 1 S:1/7 channel 0 AB37

Configuration Name PLC Type

ABSER422 Allen-Bradley PLC 5 family

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Allen-Bradley Serial Allen-Bradley Serial (DF1 protocol) 1 2 RS 422 19200 8 1 none 1 S:1/7 channel 0 AB38

Appendix

Page 104

Configuration Name PLC Type

ABDHP Allen-Bradley PLC 5 family

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Allen-Bradley DH/DH+ Allen-Bradley Data Highway Plus I/O 2 N/A N/A N/A N/A N/A 1 S:1/7 DH+ port N/A (A-B 1770-CD twinaxial, or equivalent)

Configuration Name PLC Type

CHD50 Cutler-Hammer D50, D300

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Cutler-Hammer D50/D300 serial RS 485 1 2 RS 485-2 9600 8 1 none 1 F00106 programming port CH32

Appendix

A-9

Page 105

A-10

Configuration Name PLC Type

CHD200 Cutler-Hammer D200

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

Cutler-Hammer D200/D500 serial RS 422 1 2 RS 422 9600 8 1 none 1 R62F computer link CH31

Configuration Name PLC Type

GECMM232 General Electric Series 90

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

GE Series 90 point-to-point GE Series 90 point-to-point 1 2 RS 232 19200 8 1 odd 1 %S5 CMM port GE33

Appendix

Page 106

Configuration Name PLC Type

GECMM422 General Electric Series 90

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

GE Series 90 point-to-point GE Series 90 point-to-point 1 2 RS 422 19200 8 1 odd 1 %S5 CMM port GE32

Configuration Name PLC Type

GES90P-P General Electric Series 90

PLC driver to transfer to PM 500 Communication type PanelMate Port assigned PanelMate ID assigned Electrical Connection Baud Rate Data Bits Stop Bits Parity PLC ID needed PLC address referenced PLC port used Cutler-Hammer IDT cable #

GE Series 90 point-to-point GE Series 90 point-to-point 1 2 RS 422 19200 8 1 odd 1 %S5 programming port GE31

Appendix

A-11

Page 107

A PanelMate 500 Product Demonstration A PanelMate 500 product demonstration is described below using the built-in “coffee machine” example

Introduction The PanelMate 500 unit is available in 6 online models. Four of these models are: a 4-line vacuum fluorescent display (VFD) unit, a 4-line liquid crystal display (LCD) unit and 2-line versions of each display type. In addition, separate 4-line LCD and 4-line VFD models are available featuring the exclusive “Virtual Mentor” capability. The Virtual Mentor capability provides autopilot-like functions for the most demanding applications. As an easy-to-understand example of how the model 500 can function as a complete operator station, we have provided a simulation which mimics the way a coffee machine works. This simulation is loaded into every unit as one of the final stages in its manufacture. Why a coffee machine? A coffee machine requires you to act as an operator by reading from choices presented to you, then performing a sequence of actions in order to obtain the desired result. Occasionally, something unexpected will occur - a cup will fail to be placed in position by the machine for filling, or the machine will be out of sugar or another supply. In such a case, you will begin a kind of “diagnostic” sequence by looking for feedback from the machine (e.g. messages providing status about the cups or other supplies) and expecting to take further action (restock cups or choose another beverage.) The PanelMate 500 is more than just a message display unit - it’s a complete operator station that can lead even inexperienced operators through sequences of operation in much the same way as in our coffee machine example. In addition to merely presenting messages to an operator, PanelMate 500 can display bar and numeric data, plus process numeric entry and control button actions by the operator. And tri-function LEDs are built into the control buttons. As with our other PanelMate products, the model 500 features considerable built-in mathematical capabilities which make it a powerful link between operators and machines.

A-12

Appendix

Page 108

Demonstration To illustrate a few of PanelMate 500’s capabilities using our “coffee machine” example, just follow these steps with your PanelMate 500: After initial power-up, the PanelMate 500 will display a Welcome page, including the invitation to press the first soft function key beneath the page for “Run”, or the fourth soft function key for “Readme”. Press the key corresponding to Run, to link to the Main Menu. The “Main Menu” presents 9 choices to the operator, 3 of which are visible in 4-line units and 1 of which is visible in 2-line units. You may use the right Ø and left × arrow keys on the keypad to scroll down and up through the 9 selections, then press the carriage return ↵ key to choose the item selected. Or, simply press the number of the selection you wish to make, as follows: Press the number 9 to link to the Coffee Menu page. The selections from the Coffee Menu are: 1 Run Machine 2 Clean Machine 3 Re-stock Supply Press the number 1 to link to the Select Beverage page and begin the coffee brewing process

Appendix

A-13

Page 109

The choices from the Select Beverage page are: 1 Coffee 2 De-caffeinated 3 Tea Press 1 to select Coffee and link to the Confirm Selection page. On the Confirm Selection page, press the Continue soft function key just below the display area. This will link to the Brew Strength page. The Brew Strength page presents the soft function key choices: Light

Med.

Dark

Mud

Press any of the four choices, to link to the SelectAdditives page. The Select Additives page asks whether you wish to “Add Creamer?” Your soft key choices are Yes or No. Press either the Yes or No soft function key to continue additive selection. Press either the Yes or No soft function key for sugar. Press either the Yes or No soft function key for sweetener. Press the Start soft function key to begin brewing.

A-14

Appendix

Page 110

The first time you complete the previous cycle, you will link to the “Brewing Complete” page. If you then press the Continue soft function key, you can start the cycle over again. When you complete the second coffee brew cycle, the system will link to the Out of Beverage page, and will generate an alarm. The alarm tone will be on, and the red LED embedded in the ALARMS control button will be in rapid blink mode. Press the ALARMS control button (the top left control button, whose red LED will be blinking) to link to the Alarm Assistance page. Press the Horn soft key to turn off the audio alarm. Press Help to link to the Out of Beverage page which identifies the unavailable beverage. Select the Refill soft key to link to the Edit Beverages page. On the Edit Beverages page, use the right arrow Ø to choose a beverage field in which you can edit the number of servings remaining before the next alarm. As you continue to operate the simulation, you can also resupply coffee, decaff coffee, tea, sugar, sweetener, cream or cups as supplies are exhausted. After entering the Additives or Brewables edit page, you can use the right arrow Ø key and the numeric keypad to “restock” the item chosen. Enter Brewables to restock coffee. If you attempt to choose the Supplies edit page, you will be asked to enter a password for protected level #1. Simply press the number 1, followed by the carriage return ↵ key. You may now edit the supply of cups, from 1 to 20. The number of cups you select will also be displayed as a horizontal bar at the bottom of the screen. Press the blue Home u key to return to the Main Menu page. To cycle through an examination of all color and blink states of the tri-color LEDs, repeatedly press the topmost control button on the right side of the keypad.

Appendix

A-15