Page 111
Comments About the Online Simulation After you have performed the previous demonstration, you may wish to return to the Main Menu and explore other selections in addition to the ones already noted. The most important concept illustrated by the “coffee machine” is that the PanelMate 500 can alter the way in which it leads operators through a sequence, depending upon conditions at the time. It can react to data from a PLC or network, internally stored data or inputs from the operator, and present choices or sequences to the operator accordingly.
Exploring the Configuration for the Coffee Machine If you have run the coffee machine simulation AND you have used the Getting Started Users Guide to explore the configuration software, you now may wish to look at the configuration for the coffee machine. •
On your PC, select and start the PanelMate 500 software (refer to chapter 5 of this Guide, if needed).
•
One disk furnished with your software is labeled EXAMPLES. Locate it and insert it into the floppy drive of your PC.
•
From your PanelMate 500 Configuration Editor, click on File, then Open Configuration.
•
Select your floppy drive location (Typically, A or B) then locate and select the file named 4LN_COFF.CVB. This is a file for a 4-line vacuum fluorescent unit. After you have retrieved the file successfully from the floppy disk, select “File” from the software pull-down selections and use “Save Configuration As” to save the file to the PM500 subdirectory on your hard drive, for further use.
The previous process should result in presentation of the directory for the 34 pages which comprise the coffee machine application. You may select individual pages or properties to explore at random, but we strongly recommend that you use the built-in printing capabilities of the software to print several summaries of the coffee machine simulation.
A-16
Appendix
Page 112
By clicking on File, then selecting Print Report, you can print your choice of Configuration Properties or individual Pages for the coffee machine simulation. If you print everything available, you will generate nearly 50 pages of information. Instead, we recommend you select and print only a limited selection of pages. In order to make these selections, your print selection screen should look like this (note that “System Page”, “Page Link Summary” and pages 18, 19, and 8030 are selected):
The following are details in the printouts that you should look for: Selection
Illustrates
Page Linkage Summary
*
Shows appearance of all 34 onscreen pages in the application.
(prints 5 sheets)
*
Shows how every page is linked to any other pages via:
-
- previous or next keys
-
- any of the 4 soft function keys below the screen
-
- any numbered selections on Menu pages
-
- any linkages due to Virtual Mentor Response Templates associated with a page
Appendix
A-17
Page 113
Page #18
* Shows a Menu Page appearance.
(prints 1 sheet)
* Shows that the three selections available to operators (1, 2 or 3) set the scratchpad variable “fbeverage” equal to 1, 2 or 3 and then assign the screen to Go To page 19. * Shows that a Response Template (Virtual Mentor feature) checks several scratchpad variables (e.g. “cups”) and assigns responses accordingly (e.g. goto 6020). * Shows that the Previous key returns the screen to page 9 and the Next key generates No Action.
Page #19
* Shows a Data Page appearance.
(prints 1 sheet)
* Shows the assignments of the 4 soft function keys (keys 1 and 4 go to pages 20 and 18, respectively) * Shows static text content and location on display. * Shows the 4 possible text strings which could appear in a State Indicator located after the static text string “You Selected”. Also shows the value 0, 1, 2 or 3 in the scratchpad variable “fbeverage” which will generate the text “Error”, “Coffee”, “Decaff”, or “Tea”. * Shows that a Response Template (Virtual Mentor feature) checks several scratchpad variables (e.g. “coffee”) and assigns responses accordingly (e.g. goto 6000). * Shows that the Previous key returns the screen to page 18 and the Next key generates No Action.
A-18
Appendix
Page 114
Page #8030
*
Shows a Data Page appearance.
(prints 1 sheet)
*
Shows static text content and position on display.
*
Shows position of Numeric Data Object, plus all of its parameters and references.
*
Shows Bar Graph Object, plus all of its parameters and references.
*
Shows that security level 1 password will protect access to this page.
*
Shows that the Previous key returns to page 8000 and the Next key generates no action.
System Page
*
Shows that at powerup, by setting six Response Template Conditions to 1, a set of internal scratchpad variables can be assigned initial values (such as [sp, cups] = 3). This is a Virtual Mentor feature.
(prints 2 sheets)
*
Shows the assignments of the 8 Function Keys and 8 LEDs. Note how pressing Function Key #5 increments upward the scratchpad variable called “manual”, in order to illuminate LED #5 with different colors or blink assignments.
By examining these printouts while using the configuration software to explore pages in the configuration, you can begin to see how pages are constructed and linked together. Remember that because this is a simulation, there are no references on any pages to actual PLC addresses. An actual application would access PLC addresses and make use of PanelMate 500’s data objects and mathematical tools to update operators while permitting numeric entry and control operations. Note that if you replace the coffee machine simulation in your online unit with any other application, you may reload it to that unit, as long as it is a 4-line unit featuring the Virtual Mentor capability (models 542LM and 542VM). Refer to the next section of the Appendix, titled “A Configuration Containing All Page Types and All Object Types” for an example of the loading process. Two files are provided on the Examples diskette, titled 4LN_COFF1.CVB (for 4-line vacuum fluorescent) and 4LN_COF.CLB (for 4-line LCD). Because the coffee machine simulation makes temporary use of the Virtual Mentor capability, it cannot be downloaded to models 522L, 522V, 542L or 542V.
Appendix
A-19
Page 115
A Configuration Containing All Page Types and All Object Types Introduction In addition to the coffee machine simulation already described in this Appendix, there is another simulation available on the EXAMPLES diskette. It is a configuration called ASAMPLE1, and it contains 27 pages designed to provide examples of every one of the 5 onscreen page types, all 6 object types, and the system page. As with the coffee machine simulation, ASAMPLE1 does not use any PLC references, and when loaded to the online unit, does not need to be connected to a PLC in order to run its simulation. Files are provided to load onto any model of PanelMate 500. This configuration may be examined on your PC, then downloaded to your PanelMate 500 online unit.
Loading the Configuration ASAMPLE1 If you have run the coffee machine simulation AND you have used the Getting Started Users Guide to explore the configuration software, you now may wish to load and examine the ASAMPLE1 configuration. Actually, we have furnished 4 versions of the ASAMPLE1 file, corresponding to the 4 styles of online units. You will need to select the file which corresponds to the type of online unit to which you will be downloading:
A-20
File Name
Type of Online Unit
ASAMPLE1.CLA
2-line LCD unit
ASAMPLE1.CLB
4-line LCD unit
ASAMPLE1.CVA
2-line vacuum fluorescent unit
ASAMPLE1.CVB
4-line vacuum fluorescent unit
Appendix
Page 116
Before you begin the process, be aware that the ASAMPLE1 file is preconfigured to use the Cutler-Hammer D50/300 PLC driver, even though the simulation runs in the online unit without any connection to a PLC. If you did not load the Cutler-Hammer D50/300 PLC driver to your PC when you installed your PanelMate 500 configuration software, please return to Chapter 4 of this Guide to install it at this time. If you do not have this driver available, please continue and you will be advised of an alternative.
Appendix
•
On your PC, select and start the PanelMate 500 software (refer to chapter 5 of this Guide, if needed).
•
One disk furnished with your software is labeled EXAMPLES. Locate it and insert it into the floppy drive of your PC.
•
From your PanelMate 500 Configuration Editor, click on File, then Open Configuration.
•
Select your floppy drive location (Typically, A or B) then locate and select the file named ASAMPLE1.CVB. This is a file for a 4-line vacuum fluorescent unit, and will be the basis for the examples used in the remainder of the discussion. If your online unit is one of the other 3 types, refer to the listing on the previous page to select the correct version of ASAMPLE1.
A-21
Page 117
The previous process should result in presentation of the directory for the 27 pages which comprise the ASAMPLE1 application. If you do not have the Cutler-Hammer PLC driver available with your software, you will want to select another PLC type, corresponding to a driver which IS installed in your PC. To do so, follow this procedure: 1. Within the directory tree, click on Properties, then PLC Name and Port table.
Click on the Device field and select any PLC type available.
A-22
Appendix
Page 118
2. Click on the PLC Name tab. Double-click on the Model field, click on a model to select it, then click on the adjacent Remote ID field. This process should assign a default set of entries to all 3 field types.
3. Click on OK to complete the new PLC driver selection. •
After you have retrieved the file successfully from the floppy disk, select “File” from the software pull-down selections and use “Save Configuration As” to save the file to the PM500 subdirectory on your hard drive, for further use.
•
From the File menu choices, select “Compile” and compile the file ASAMPLE1 onto your hard drive.
To download this application to your PanelMate 500 unit, follow these steps: •
Refer to Chapter 11 of the Getting Started Guide: 1) Put the PanelMate into the Offline Mode 2) Connect the transfer cable from your PC to the online unit 3) Transfer the Cutler-Hammer (or other) PLC driver to the online unit 4) Transfer the ASAMPLE1 file to the online unit 5) Put the PanelMate online unit back into the Run Mode
Appendix
A-23
Page 119
Demonstration The ASAMPLE1 configuration illustrates all 5 onscreen page types, all 6 data object types, plus the offscreen “system page” (the use of the 8 control buttons, built-in LEDs and numeric entry pad). After initial power-up, the PanelMate 500 will display a Startup page, including the invitation to press the fourth soft function key for “Reset”. Press the fourth soft function key to Reset the simulation. Pressing that key causes the text to change from “Reset” to “Ready”. The online application is now ready for you to explore. You should plan to access all 5 types of onscreen pages: Menu Data Maintenance Change Password Setup In addition, you should view all 6 types of Data Objects illustrated on the Data pages: Text Conditional Indicator State Indicator Numeric Data Alpha Display Bar Graph And, you should observe how the 8 control buttons, built-in LEDs, navigation keys and numeric entry keys are used.
A-24
Appendix
Page 120
Once the online unit indicates that it is Ready: Press the blue “Next” key to advance to page 2, which is the HOME page. Press the first soft function key, labeled “Next” to advance to page 100, which is a Data Page. Note the additional page choices available on this page: Data, Menu, Maintenance and More. Press More to advance to page 101, then press More again to advance to page 102, then press More again to advance to page 100 again. Note that pages 101 and 102 presented selections to link to Change Password, Setup and Alarms pages. Press the blue Previous and blue Next keys several times, to see how the screen presentation moves “backward” and “forward” through its linked pages.
Appendix
A-25