Page 1

DATASHEET MEMEX A87L-0001-0017

OTHER SYMBOLS: A87L00010017, A87L0001 0017, A87L0001-0017, A87L 00010017, A87L 0001 0017, A87L 0001-0017, A87L-00010017, A87L-0001 0017, A87L-0001-0017

RGB ELEKTRONIKA AGACIAK CIACIEK SPÓŁKA JAWNA Jana Dlugosza 2-6 Street 51-162 Wrocław Poland www.rgbelektronika.pl biuro@rgbelektronika.pl +48 71 325 15 05 www.rgbautomatyka.pl www.rgbautomatyka.pl www.rgbelektronika.pl

Page 2

YOUR PARTNER IN MAINTENANCE Repair this product with RGB ELEKTRONIKA

LINEAR ENCODERS

ORDER A DIAGNOSIS ∠

PLC SYSTEMS INDUSTRIAL COMPUTERS

ENCODERS

CNC CONTROLS

SERVO AMPLIFIERS

MOTORS CNC MACHINES

OUR SERVICES

SERVO DRIVERS

POWER SUPPLIERS

OPERATOR PANELS

At our premises in Wrocław, we have a fully equipped servicing facility. Here we perform all the repair works and test each later sold unit. Our trained employees, equipped with a wide variety of tools and having several testing stands at their disposal, are a guarantee of the highest quality service.

Buy this product at RGB AUTOMATYKA

BUY ∠

Page 3

MME/HSL Memory Upgrade for Fanuc For Series 6, 11 & 12 Installation Instructions and Operator’s Manual M100700D

© 2009-- Memex Automation Inc. All rights reserved. No part of this manual may be reproduced without express written consent of Memex Automation Inc. Memex does not assume any liability for the use of this manual.

Page 4

Contents

Table of Contents Chapter 1 – Introduction ...........................................................................

4

General ..................................................................................................... 4 Features ........................................................................................... ......... 4 Board Features Description ....................................................................... 5

Chapter 2 - The Basics ..............................................................................

6

Using Parameter Sentry System ............................................................... 6 Installation Considerations ........................................................................ 7 Backup Critical Parameters ....................................................................... 7 Verify Your Control .................................................................................... 7

Chapter 3 - Installation for Fanuc 6 ........................................................ 8 Back Up Your Control ................................................................................ 8 NC Parameters .................................................................. 8 Pitch Error Compensation .................................................. 8 Part Programs .................................................................... 9 Tool Offsets ........................................................................ 9 Work Offsets ...................................................................... 9 PC Parameters ................................................................. 10 System Parameters .......................................................... 10 Setting Data ...................................................................... 10 Quick-Load procedures for Fanuc 6 ....................................................... 11

M100700D Page 2

Page 5

Contents

Installation Checklist for Fanuc 6............................................................ 14 Restoring Your Fanuc 6 ......................................................................... 15

Chapter 4 - Installation for Fanuc 11/12 ................................................ 18 Back Up Your Control .............................................................................. 18 NC Parameters ................................................................. 18 Pitch Error Compensation ................................................. 18 Part Programs .................................................................. 19 Tool Offsets ...................................................................... 19 Macro Variables ................................................................ 19 Quick-Load procedures for Fanuc 11/12 ................................................ 20 Manual Installation Procedures for Fanuc 11/12 .................................... 23 Installation Checklist for Fanuc 11/12 .................................................... 25

Chapter 5 – Appendix ............................................................................... 26 Technical Summary for Fanuc 6 ............................................................ 26 Technical Summary for Fanuc 11/12 ..................................................... 28 Parameter Worksheet .............................................................................. 30 Specifications ........................................................................................... 33 Standard ASCII Table .............................................................................. 34

M100700D Page 3

Page 6

Chapter 1 - Introduction

Introduction General The MME (Memex Memory Engine) is a Static RAM based memory board, designed to replace the old BMU (Bubble Memory Unit) found in Fanuc Series 6, 9, 11 and 12 machine tool controls. Our leading edge technology has enabled us to create a high speed, low power alternative to conventional Fanuc memory. Besides being a memory replacement the MME has a unique feature called “QUICK-LOAD”. This allows the various parameters stored in the original BMU to be automatically transferred to the MME via a special BMU socket on the side. With the BMU “piggy-backed” onto the installed MME, all NC and PC parameters can be transferred by just powering on the control normally. Generally, the “QUICKLOAD” feature installs the MME board easily with very little downtime – that said, still perform a backup of parameters and key macro programs. Once the new MME has been proven (all parameters checked and the machine functionally tested), the “PARAMETER SENTRY” (PS) system can be used to backup the verified parameter settings. This useful feature will keep a copy of the machine’s critical parameters in a special on-board, non-volatile, memory location for safekeeping. Finally, the battery backup system is unique in that the battery is continuously conditioned and recharged when the power is on. New Lithium rechargeable technology has been implemented to keep your data safe for more than 10 years.

Features

20 MHz on-board RISC processor High speed, low power, SRAM in 128k, 512k or 2 meg sizes (HSL5 board only) Non-volatile SRAM for on-board “Parameter Sentry” backup Easy-to-use switches for parameter save and restore Rechargeable, long life, Lithium battery for Part Program Storage SRAM enabling a feature called “PermaCharge Battery System” On-board 19200-BAUD serial port for diagnostics In-line BMU connector for “Quick Load” parameter transfer Compact 5.3” x 5.9” board size

M100700D Page 4

Page 7

Chapter 1 - Introduction

Board Features Description (Fanuc 6/11/12 - 320M to 1280M)

5

2

4 1

6

3

7 8

11

9

10

1

CNC Connector Plugs into the BMU slot on the CNC

2

CPU 20 Mhz processor in socket

3

4

5

7

SRAM (1 – 4) 128K x 8 high speed, low power

8

Status LEDs Turbo, Data Status, Quick Load, Save and Restore

9

Parameter Sentry System Toggle switch & push button

Option Jumpers Used to select CNC type NVSRAM 8K x 8 Non-Volatile SRAM for Parameter Sentry System Serial Port High speed serial port for diagnostics

10 MOS Connector Used for HSL upgrades

11 Perma-Charge Battery Rechargeable, Lithium battery

6

BMU Connector Used for quick-loading old BMU Note: 2 Megs on a Fanuc 11/12 uses HSL

M100700D Page 5

Page 8

Chapter 2 – The Basics

The Basics Using the Parameter Sentry System The MME’s Parameter Sentry System is unique and simple to use. The system offers protection of the first 20 meters (8K) of memory, thus protecting all of your NC system parameters, PC parameters, Tool Offset data, Pitch Error Compensation data and System data. Note that part programs are not included. The HSL saves the bottom 1280 meters (512k). All of these parameters are stored in Non-Volatile SRAM (NVSRAM). This memory is Non-Volatile meaning that it does not require a backup power source of any kind and is a relatively permanent and a convenient form of storing your critical control parameters. To use the Parameter Sentry System, power on your Fanuc control and bring the CRT to the Position screen. Open the control cabinet with the Fanuc control. Make sure that the power remains ON when you open the door to the cabinet. While holding the toggle switch at the bottom of the Memex MME board toward the “SAVE” position, momentarily PUSH the “PARAM SENTRY” button, and then release the toggle switch. You should notice the LED adjacent to the toggle switch light up for approximately one second. This will save your Fanuc system parameters in the NOVRAM. To RESTORE your parameters, reverse the above procedure. Make sure that your Fanuc CNC is turned on and that you have access to the Memex MME. While holding the toggle switch toward “RESTORE”, momentarily PUSH the “PARAM SENTRY” button, then release the toggle switch. Again, you should notice the “Restore” LED light up for one second. Power off your control, then power on again for the saved parameters to take effect. If an error relating to part programs occurs at this point after powering on the control, you may also need to Delete All Part Programs by powering on the control while holding the DELET & RESET keys.

Memex HSL3 Board Used For Fanuc 11 & 12 Upgrades to 2 Megs

M100700D Page 6

Page 9

Chapter 2 – The Basics

Installation Considerations The installation of the MME should be conducted with care. Never install or remove a board with the control power on (the main power can be on, but not the control). Take care with the handling of the MME and BMU, as they are static sensitive. Keep the boards in the anti-static bags provided. Take care not to place the circuit boards on a metal surface as the backup battery could suffer damage if shorted. Do not place the MME in any other slot on the Fanuc masterboard, other than the one, labeled BMU. Do not force, drop or otherwise mishandle the boards during the installation procedure. Always check the functionality of the machine at the end of the installation (i.e. move the axes, perform a tool change, run a program, etc.).

Backup Critical Parameters Although the MME has the ability to transfer the relevant NC parameters, it is a good idea to make a manual backup of all information in the BMU before proceeding (if possible). The MME will contain no useful information when shipped, and as such the following data must be reloaded: NC parameters, PC parameters, tool offsets, part programs, macro variables and names (if applicable), etc. Follow your Fanuc manual for the appropriate procedure.

Verify Your Control Once the MME has been installed either manually or by the Quick-Load method, satisfy yourself that the control is working properly and that all of your parameters have been restored. Test the machine by the following procedure through either MDI or program:

Home all axes, tool-changers and pallets.

Check spindle functionality through all speeds and gear ranges.

Check also Clockwise and Counter-clockwise rotation with M3 and M4 commands.

Check the tool changer. Be sure that the tool you received was the tool requested and that the carousel rotates in the proper direction.

Check the pallet changer (if applicable). If your machine requires special custom macros for a pallet changer or tool changer, be sure that they have been loaded.

Once your machine has been proven with the MME, you have successfully upgraded your control.

M100700D Page 7

Page 10

Chapter 3 – Installation for Fanuc 6

Installation for Fanuc 6 Backup Your Control Before starting the installation, power on the control and verify that the machine tool is in good working order. If the control has a system error, or the BMU is inoperable, you will have to replace your memory board with the MME, and restore the information from existing backup sources.

Important!

Backup the following BMU memory contents: NC parameters, PC Parameters (if parameter 3.7 = 1), Tool Offsets, Pitch Error Compensation, and Part Programs (if applicable). All of this information is contained in the Bubble Memory Unit (BMU) and must be restored; therefore all of this information must either be written down or punched out of the control via the RS-232 serial port. Use the “Fanuc System 6 Machine Parameter Worksheet” provided at the end of this document to record the important parameter data. Use the following procedures to save the data on a computer. If in doubt, consult your Fanuc manuals, as they are your ultimate authority on your particular version of control.

1. Set up your computer to receive data through its COM port and connect it to your Fanuc control. Set the communication parameters on your PC for 7 data bits, and the stop bits and baud rate as determined by the applicable parameters for your control. Please refer to the “Fanuc 6 Technical Summary” at the end of this document for the appropriate parameters.

NC Parameters

2. Make the computer ready to receive the data.

Select EDIT Mode.

Press the PARAM key to display the Parameter Screen.

Press P

- 9

9

9

9

PUNCH

The Parameters will be punched out.

Pitch Error Compensation

3. Make the computer ready to receive the Pitch Error data.

Confirm that EDIT Mode is selected.

Confirm the Parameters are displayed on the screen.

Press P

- 9

9

9

8

PUNCH

The Pitch Error data will be punched out.

M100700D Page 8