Page 11
Chapter 3 – Installation for Fanuc 6
Part Programs
4. NOTE: Any macro programs in the range of O8000-O9999 that have been protected from editing will not be transferred. Release the parameter bits that are protecting them. On a Fanuc 6-B2, one would go through the following steps: To release the Macro Program “Edit Protect” on a Fanuc 6-B2: - Select MDI Mode. - Switch the Parameter Write switch to the ON position (ignore the PW100 alarm). - Press the PARAM key to display the Parameter Screen. - Set parameter 319 bit 7 and 318 bit 7 (left most digit) to a 0 (zero). - Switch PWE to the OFF position. - Press RESET to clear the PW100 alarm. Make the computer ready to receive the programs.
Select EDIT Mode.
Press PRGRM to display the Program Screen.
Press O
- 9
9
9
9
PUNCH
All of the programs will be punched out.
Tool Offsets
5. Make the computer ready to receive the Tool Offset data.
Confirm that EDIT Mode is selected.
Press OFSET to display the Tool Offset Screen.
Press P
- 9
9
9
9
PUNCH
The Tool Offsets will be punched out.
Work Offsets
6. Press OFSET again to display the Work Offset Screen. If it does not appear, you do not have any Work Offsets in your machineproceed to the next step. If you do have a Work Offset screen, record the Work Offsets in the following chart: Relative X Y Z
00
Relative X Y Z M100700D Page 9
01
02
03
04
05
06
Page 12
Chapter 3 – Installation for Fanuc 6
PC Parameters
7. Check Parameter 3, bit 7. If this is a 0, go to step #8 (System Parameters) as you have no PC Parameters. Write down the PC Parameters between, and including the following parameters: N600-619, N1001-1040, N2001-2010 and N3001-3036.
Press the PARAM key twice to display the PC Parameter Screen.
Type N 6
0
0
INPUT to select PC Parameter 600.
You can use the (cursor) key to advance the PC Parameter in
System Parameters
8. Press the PARAM key once again to display the Parameter Screen.
Setting Data number. Write down the PC Parameter values on the Parameter chart found the back of this manual. Repeat the last two lines to record the remaining PC Parameters.
Type N 0
INPUT to select Parameter 0. You can use the
(cursor) key to advance the Parameter number. Write down the System Parameter values on the Machine Parameter Worksheet found at the end of this manual. Repeat the last two lines to record the remaining Parameters.
9. Press the SET key to display the Setting Data Screen.
Record all of the Setting Data on the Parameter Worksheet found in the Appendix of this manual.
Fanuc 6-TB Control – Memex Also Makes BTRs For Serial Dripfeeding
M100700D Page 10
Page 13
Chapter 3 – Installation for Fanuc 6
Quick-Load Procedures for Fanuc 6 Time Needed: Tools Needed: Components: Controls:
1 hour (approx.) 1 Philips Screwdriver 1 MME memory board Fanuc 6A, 6B and 6-B2
Before starting the installation, power on the control and verify that the machine tool is in good working order.
Important!
Make sure that you have a current backup of the NC parameters, including PC Parameters, Tool Offsets, Pitch Error Compensation, and Part Programs. For instructions on downloading your control’s information, refer to previous section entitled “Backup Your Control” at the beginning of Chapter 3. 1. Inspect the Memex Memory Engine (MME) for any damage during shipping. Also check that the “CNC Type” jumpers have been set to the Fanuc 6 control type.
2. With the Fanuc control powered off and the Emergency Stop (E-STOP) Remove the button depressed, gain access to the main master-board. Find the Bubble Bubble memory Memory Unit (BMU) board on the right-hand side of the master-board, and carefully remove it with a Philips screwdriver. Carefully place the BMU in the anti-static box supplied, and set it aside.
Install the MME memory
3. Install the MME in the slot where the BMU was removed once again using the Philips screwdriver. 4. Locate the Parameter Write Enable (PWE) switch on the lower left of the master-board. Move the switch to the right to the “ON” (enable) position.
CAUTION!
5. With the 0 (zero) and DEL “DELETE” keys depressed on the front MDI panel, power on the control. This action will cause the control to startup and immediately clear the entire memory of the MME. If the control will not power on at this point, check that the cabinet door interlock is bypassed. The control may take a few seconds to clear the entire memory. You will then be given a “WARNING: SYSTEM INCONSISTENT” alarm and will be prompted to press RESET to continue. Ignore this “Reset” prompt. 6. Power off the control. M100700D Page 11
Page 14
Chapter 3 – Installation for Fanuc 6
7. Restore the PWE switch to the “OFF”, or disabled, position.
MME Quickload! Copy the Data
8. Mount the original BMU onto the blue “BMU” connector found on the MME board. Screw down the top screw into the MME to secure the BMU properly. 9. Power on the control with the door interlock disabled. The control should start-up normally from the original BMU. During this boot up process, parameter data is being relocated to the appropriate memory areas in the MME. To ensure a complete transfer, view the parameter screen, page through all the tool offsets, etc. If all looks normal, release the EMERGENCY STOP (E-STOP) button. 10. Power off the control and carefully remove the BMU. Set the BMU aside in the anti-static bag provided.
Check the Parameters
11. Power the control on holding DELET and RESET . It should start-up and arrive at the position screen. Check all your parameters, tool offsets etc., carefully. Note that Part Programs do not get Quick-loaded at this time. At the program screen, in EDIT mode, view the directory by pressing CAN then ORIGIN . This will verify the available memory in the new MME. 12. Initiate a Parameter Sentry “SAVE” operation to save your parameters to non-volatile memory. It is best to do this when there are no part programs present as the directory that is saved should be clear of entries.
13. Test your machine thoroughly. You can proceed to the section of this manual entitled “Verify Your Control” for assistance.
M100700D Page 12
Page 15
M100700D Page 13
MME Quickload on a Fanuc 6
PTELLLLLLLLLL LL hha ee
WY MSHONNG/DIS9 ae - 4 r tec
[ - 9sz nwa
Chapter 3, Installation for Fanuc® 6
Page 16
Chapter 3 – Installation for Fanuc 6
Installation Checklist for Fanuc 6 Check Machine - Power On - Check for Machine Problems Before You Start. Backup Parameters and Programs. Power Off. Depress E-STOP Remove BMU and set it aside. Mount MME. Set PWE to enable. Power On the Control with 0 and DEL depressed, to erase MME. Power Off and turn PWE off. Piggy-Back BMU to MME - Secure with Screw. Power Up - Page through the Tool Offsets. Power Off. Remove BMU. Power On while holding DELET and RESET . Check the Parameters and machine operation thoroughly. Save your parameters with the Parameter Sentry Save. Complete.
M100700D Page 14
Page 17
Chapter 3 – Installation for Fanuc 6
Restoring your Fanuc 6 If you have successfully installed your MME via the Quick-Load method described in the previous section, then skip this chapter. This chapter is designed to step you through a manual BMU restore operation with the assumption that you have adequate backups.
1. Open the door to the control’s master-board on your machine.
Replace the BMU with your new memory board.
Turn ON (Enable) the Parameter Write switch located in the lower left corner of the control’s master-board (ignore the PW100 alarm).
CAUTION!
Power ON the control while holding both the 0 (zero) and DELET keys. This will delete the entire memory board in your control! Wait for the control to completely erase your new memory board. It will be done when you get the “System Inconsistent” message.
2. Set up your computer to send data through the COM port and connect it to your Fanuc control.
Press the PARAM key to display the Parameter Screen.
Type N 3
1
0
INPUT to select Parameter 310.
You can use the (cursor) key to advance the Parameter number.
Set the communication parameters by pressing P , the original value, then INPUT .
Repeat the last two lines to enter all the system parameters that you had previously recorded.
3. Power OFF the control, then power it back ON.
Loading NC Parameters
4. Make the computer ready to send the Parameter data to the control.
Select EDIT Mode.
Press the EMERGENCY STOP button in.
Press the SET key to display the display Setting Screen.
Restore the correct Setting information from your backup. Confirm that the Parameter Write switch is in the ENABLE position.
Press the PARAM key to display the Parameter Screen.
Press P
- 9
9
9
9
M100700D Page 15
READ
Page 18
Chapter 3 – Installation for Fanuc 6
Pitch Error Compensation
Send the (backed-up) Parameters to the control from your computer.
5. Make the computer ready to send the Pitch Error data to the control.
Confirm the EMERGENCY STOP button has been depressed.
Confirm that the Parameter Write switch is in the ENABLE position.
Confirm the Parameters are displayed on the screen.
Press P
- 9
9
9
8
READ
Send the Pitch Error data file to the control from your computer.
6. Power OFF the control, then power it back ON.
PC Parameters
7. If Parameter 3, bit 7 was a 0, then skip this step; otherwise:
Confirm that the EMERGENCY STOP button is in.
Confirm that the Parameter Write switch is in the ENABLE position.
Press the PARAM key twice to display the PC Parameter Screen.
Type N 6
0
0
INPUT to select PC Parameter 600. You can use the (cursor) key to advance the PC Parameter number and (page down) to view a page worth of PC Parameters.
Set the PC Parameters by pressing P , the original value, then INPUT .
Program Data Input Option
Repeat the last two lines to enter all the remaining PC Parameters that you recorded.
8. Press the PARAM key to display the Parameter Screen.
Type N 3
INPUT to select System Parameter 3.
Check that bit 1 (2 from right), of System Parameter 3 is a 1. If it is nd not, set it to a 1 by pressing P , the new value, then INPUT .
Reset the Control
9. Power OFF the control.
Turn OFF (Disable) the Parameter Write switch on the master-board.
Release the EMERGENCY STOP.
Power the control back ON.
M100700D Page 16
Page 19
Chapter 3 – Installation for Fanuc 6
Loading Tool Offsets
10. Make the computer ready to send the Offset file.
Confirm that the control is in EDIT Mode.
Confirm that the Program Screen in showing.
Press O
0
0
0
1 , then READ
Send the Tool Offset file to the control from your computer. The Tool Offsets will be loaded into the control as program O0001. Once the file has been sent, press RESET .
Put the control in MEM Mode, then press CYCLE START .
Press the OFSET key to display the Tool Offsets.
Verify that all of the Tool Offsets have been loaded successfully. If not, reload the Tool Offsets manually as necessary. If all of the Tool Offsets have been reloaded successfully, delete program 1 by pressing O
Loading Part Programs
0
0
0
1 , then DELET .
11. Any macro programs that have been protected from editing will not be loaded. On a Fanuc 6-B, check that parameters 318 and 319 have bit 7 equal 0.
To release the Macro Program “Edit Protect” on a Fanuc 6-B: - Select MDI Mode. - Switch PWE to the ON position (ignore the PW100 alarm). - Press the PARAM key to display the Parameter Screen. - Set parameter 319 bit 7 and 318 bit 7 (left most digit) to a 0 (zero). - Switch PWE to the OFF position. - Press RESET to clear the PW100 alarm.
Make the computer ready to send the program file.
Press PRGRM to display the Program Screen.
Press O
Send the programs to the control from your computer.
- 9
9
9
9
READ
12. If the programs were protected, restore parameters 318 and 319 to their original values. 13. Press the OFSET key and restore the Work Zero offsets.
M100700D Page 17
Page 20
Chapter 4 – Installation for Fanuc 11/12
Installation for Fanuc 11/12 Backup Your Control Before starting the installation, power on the control and verify that the machine tool is in good working order. If the control has a system error, or the BMU is inoperable, you will have to replace your memory board with the MME, and restore the information from existing backup sources.
Important!
Be sure to write down the NC (Service) parameters; 0, 3, 20-23, 5001-5122, 9000 and 9100-9125/9131/9207 (depending on you control). Backup the Setting Screen Data, NC parameters, PC parameters (Timers, Counters, Keep Relays, Data Tables and Position Module Information) and Tool Offsets. Use the “Fanuc System 10/11/12 Machine Parameters” worksheet provided at the end of this document to record important parameter data. Use the following procedures to save the data on a computer. If in doubt consult your Fanuc manuals, as they are the ultimate authority on your particular control.
1. Set up your computer to receive data through its COM port and connect it to your Fanuc control. Set the communication parameters on your PC for 7 data bits, and the stop bits and baud rate as determined by the applicable parameters for your control. Please refer to the “Fanuc 6 Technical Summary” at the end of this document for the appropriate parameters.
NC Parameters
2. Make the computer ready to receive the data.
Select EDIT mode.
Press the SERVICE function key.
Press PUNCH + PARAM (or ALL for Both NC + Pitche Error)
The Parameters will be punched out.
Pitch Error Compensation
3. Make the computer ready to receive the Pitch Error data.
Confirm that EDIT Mode is still selected.
Press the SERVICE function key.
Press PUNCH + PITCH
The Pitch Error data will be punched out.
M100700D Page 18