Page 31

Chapter 5 – Appendix

1: 2: 3: 4: 5: 6: 7:

Control codes (DC1 - DC4) are used and feed is punched Control codes (DC1 - DC4) are not used and feed is punched Control codes (DC1 - DC4) are used and feed is not punched [Use This Setting] Control codes (DC1 - DC4) are not used and feed is not punched Reserved PPR FANUC cassette

5111

Number of stop bits of I/O device corresponding to device number 1 1: 1 Stop bit 2: 2 Stop bits

5112

Baud rate of I/O device corresponding with device number 1 1: 50 7: 600 2: 100 8: 1200 3: 110 9: 2400 4: 150 10: 4800 5: 200 11: 9600

2201.0

Programs O9000 - O9999 (canned cycles) can 0: Be edited 1: Not be edited

11.0

Programs O8000 - O8888 can 0: Be edited 1: Not be edited

2200.3

When programs are loaded, M02, M30 and M99 should 0: Be assumed as program end 1: Not be assumed as program end. In this case a program number must exist in the first block of the program.

2200.6

When punching the program with external I/O device control (foreground editing only) [parameter 20 and 21], 0: Punch a single program 1: Punch all programs

Standard Fanuc Serial Port: (DB-25 Female) 1 = Frame Ground 2 = Transmit Data 3 = Receive Data 4 = Ready To Send 5 = Clear To Send

6 = Data Set Ready 7 = Signal Ground 8 = Carrier Detect 20= Data Terminal Ready 25= +24 Volts (DC)

The usual software handshaking cable configuration has lines 2, 3 & 7 connected through, with 4&5 optionally jumpered (hardware handshake lines) and pins 6, 8 & 20 jumpered on the Fanuc side only. NOTE: Parameters are listed as “P” “number.bit” (e.g. P 2 bit 5 is P2=xx1x xxxx) Fanuc Masterboard Serial Port: CD4 - RS-232 Honda 20 Pin Female – I/O Port 2 5 = ER1 16=CD 19=CTS 8=RD (TX) 17=SG 20=RTS 9=SD (RX) 18=DTR 14=+24VDC

M100700D Page 29

Page 32

Chapter 5 – Appendix

Parameter Worksheet Company:_________________________________

Machine No.:___________

Fanuc 10 / 11 / 12 / 15 Software Version: _______________

Date:_____________

Masterboard No.:_____________________

Setting Screen (Handy Screen): Record the settings only from the Handy Screen, separated by commas on the above line.

Par.# 0 3 20 21 22 23

Value

Par.# 5001 5002 5003 5011 5013

Value

NC-Service Parameters Par.# Value Par.# 5110 5130 5111 5131 5112 5132 5120 5140 5121 5141 5122 5142

Value

Par.# 5150 5151 5152

Value

9000

Par.# Op# Value Hex Par.# Op# Value Hex Par.# Op# 9100 1 9116 17 9132 33 9101 2 9117 18 9133 34 9102 3 9118 19 9134 35 9103 4 9119 20 9135 36 9104 5 9120 21 9136 37 9105 6 9121 22 9137 38 9106 7 9122 23 9138 39 9107 8 9123 24 9139 40 9108 9 9124 25 9200 50 9109 10 9125 26 9201 51 9110 11 9126 27 9202 52 9111 12 9127 28 9203 53 9112 13 9128 29 9204 54 9113 14 9129 30 9205 55 9114 15 9130 31 9206 56 9115 16 9131 32 9207 57 Par.# = Parameter No. Op# = Option No. (To be entered from the I.P.L. screen.)

Value

Hex

To convert the 9100 parameters to Hex, separate the left half of the parameter from the right half, look up the bit combination for each half on the following chart, and put the two back together to form the Hex value. E.g. Param 9100 = 1101 0110 > becomes 1101 and 0110 or D 6 > that then becomes D6 in hex! New value for Param 9100 = D6. 0000 = 0 0001 = 1 0010 = 2 0011 = 3

0100 = 4 0101 = 5 0110 = 6 0111 = 7

1000 = 8 1001 = 9 1010 = A 1011 = B

M100700D Page 30

1100 = C 1101 = D 1110 = E 1111 = F

Page 33

Chapter 5 – Appendix

Fanuc PC-Parameters Manual Backup No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Data

1. Timers No.

Data

No.

Spare Data

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

Parameter ------------------

No.

2. Counters Pres Current et

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

4. Data Tables No. of Data Offset ------------------

3. Keep Relays No. Data 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Special ------------------

Table No. 0 ------------------

The remainder of the Data Tables can be written down on the following chart. Photocopy the chart as many times as you need to record the rest of the Data. Line 0 of the No. of Data column in the previous chart, will tell you how many tables there are. The remaining lines in the No. of Data column will tell you how many entries are in each table. Page Down through each table, to record all the data on each.

M100700D Page 31

Page 34

Chapter 5 – Appendix

No. 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8

Data

No. 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8

Data

No. 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8

M100700D Page 32

Data

No. 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8

Data.

Page 35

Chapter 5 - Appendix

Specifications Electrical:

Physical:

Processors:

Input Power Voltage: 5V Power Consumption:

5 VDC +/- 5% 3.75 Watts (250 mA) Maximum (Excluding BMU)

Battery Life: No-Power Data Retention:

Over 3,000 Discharge Cycles or 10 Years (Minimum) 1 Year @ 24 C (Typical)

Temperature (Operating): Temperature (Storage):

-20 to +60 C 10 to 30 C

Humidity (Operating): Humidity (Storage):

10 to 90% (non-condensing) 10 to 60% (non-condensing)

Dimensions:

5.3” L x 5.9” W

MME: HSL

20 MHz RISC Peripheral Controller 32 Bit Motorola MC68340

HSL3 Mounted in a Fanuc 11 with BMI board connected

M100700D Page 33

Page 36

Chapter 5 - Appendix

STANDARD ASCII TABLE DEC. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42

HEX. 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A

SYM. NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SP ! “ # $ % & ‘ ( ) *

DEC. 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 80 82 83 84 85

HEX. 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55

SYM. + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C D E F G H I J K L M N O P Q R S T U

M100700D Page 34

DEC. 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

HEX. 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

SYM. V W X Y Z [ \ ] ^ _ ` a b c d e f g h I j k l m n o p q r s t u v w x y z { | } ~ Del *

Page 37

Chapter 5 - Appendix

Notes:

M100700D Page 35

Page 38

Memex Automation Inc. 200 – 3425 Harvester Rd., Burlington, Ontario Canada L7N 3N1 Phone: 905-635-3040 Fax: 905-631-9640 www.memex.ca support@memex.ca (905) 635-3042

Thank you for using Memex products

File: /ISO9000/DOCS/M100700D - MME for Fanuc 6, 11, 12 Manual.doc

M100700D Page 36