Page 141
10.SAMPLE SYSTEM CONFIGURATION
B-64004EN/02
10
SAMPLE SYSTEM CONFIGURATION
- 133 -
Page 142
10.SAMPLE SYSTEM CONFIGURATION
10.1
B-64004EN/02
SAMPLE CONFIGURATION I/O UNIT (I/OLINK #1/#2)
+24V
PMC
CNC RQT
OPT_P
OPERATORS PANEL
OPT
ORQ_P
ORQ
ESP
*ESP1 *ESP_X
*ESPG
+24V
DOOR STATUS
(*SGOPN)
*VLDVx *VLDPs *OPIHB RSVx RSPs
DOOR LOCK
*DCALM *MCF *MCFVx *MCFPs
MCC OFF
MCC STATUS
*SMC
I/O UNIT (I/OLINK #3)
DCS PMC *ESP2
DOOR STATUS MCC STATUS
*SGOPN
*VLDVx *VLDPs *SMC
+24V
*DCALM *MCF *MCFVx *MCFPs
MCC OFF
0V U
PSM
SPM
SVM
V 24V 200A 200B U V W LINE CONTACTOR (MAIN MCC)
SPINDLE Motor
- 134 -
Servo Motor
Servo Motor
Page 143
10.SAMPLE SYSTEM CONFIGURATION
B-64004EN/02
10.2
SAMPLE CONNECTIONS
10.2.1
Emergency Stop Signal (*ESP) I/O-Link#1 I/O UNIT *ESP (X008#4)
+24V
I/O-Link#3 I/O Unit *ESP (X008#4)
0V
PSM CX4 ESP
NOTE Use a two-contact emergency stop button with a forced dissociation mechanism. Connect the emergency stop button to the PSM, as illustrated in the figure. When the signal is input, the spindle slows down and stops. Input a power-down factor to [G008#4] other than the signal from the emergency stop button. Create a Ladder program so that [X008#4] becomes a factor of [G008#4]. Machine side
I/O-Link I/O UNIT
PMC Emergency stop factor
Emergency stop button
X008#4
Emergency stop factor other than emergency stop button
X00n#n
Ladder program
*ESPG (G008#4)
IMPORTANT Emergency stop button must fulfill the Standard IEC60947-5-1.This is mandatory. - 135 -
Page 144
10.SAMPLE SYSTEM CONFIGURATION
10.2.2
B-64004EN/02
Guard Open Request Signal (ORQ)
+24V
Guard open request button
I/O-Link I/O UNIT PMC X00n#n
Ladder program
ORQ
NOTE Create a Ladder program of conditions for making a guard open request and then input the program to the PMC side. When the guard open request signal (ORQ) is input, CNC will output the *OPNIHB signal. After the ladder program confirms the safety status, the signal for the guard unlock enable signal should be outputted by the ladder program. Also, the ladder program should inform the status of guard open by the *VLDVx and *VLDPs signals. If the input of ORQ is canceled while the guard is open, the ladder program should enter a safely stopped status (state in which the guard is open although the guard open request signal is not input). Close the guard (*VLDVx and *VLDPs are set to 1), then cancel this signal.
10.2.3
Test Mode Signal (OPT) Test start button
+24V
I/O-Link I/O UNIT PMC
X00n#n
Ladder program
OPT
NOTE When all the conditions for the MCC off test become ready, this signal (OPT) should be set to “1”.
- 136 -
Page 145
10.SAMPLE SYSTEM CONFIGURATION
B-64004EN/02
10.2.4
Guard Open Inhibit Signal (*OPIHB), Monitoring Result Signal (RSVx,RSPx), Safety check Request Signal (*VLDVx,*VLDPs)
PERATING PRINCIPLE
+24V
Guard closed SW1
SW2
Safety relay
Guard-monitoring limit switch
RY1
SW3
RY1
RY3 RY2 0V
RY2
RY3
RY3 RY2 0V
[Sample control components] SW1/SW2: Guard state monitoring
PMC#1 I/O Link#1 I/O UNIT X00n#n *VLDVx Ladder *VLDPs (Guard state *SGOPN) program switch with forced
*OPIHB RSVx RSPs dissociation mechanism
Y00n#n (Guard Lock)
SW3: Guard lock switch RY1, RY2, RY3:
I/O Link#3 I/O UNIT
Safety relay
X00m#n (Guard state *SGOPN)
- 137 -
Ladder program
*VLDVx *VLDPs
Page 146
10.SAMPLE SYSTEM CONFIGURATION
B-64004EN/02
This section describes the operation of various guard monitoring limit switches with lock mechanism and safety relays. State transition of components SW1
SW2
SW3
RY1
RY2
RY3
*SGOPN (*VLDVx, *VLDPs)
1
Guard closed Guard locked
CLOSE
CLOSE
CLOSE
ON
ON
OFF
1
2
Guard closed Guard unlocked
CLOSE
CLOSE
OPEN
OFF
ON
OFF
0
3
Guard opened Guard unlocked
OPEN
OPEN
OPEN
OFF
OFF
ON
0
4
Guard opened Guard locked
OPEN
OPEN
CLOSE
OFF
OFF
ON
0
1
Guard closed Guard locked
CLOSE
CLOSE
CLOSE
ON
ON
OFF
1
In a normal operation, the transition of 1, 2, 3, 4,1, 2, and so on is repeated. RY3 detects whether RY1 and RY2 contacts are made. If an unusual event is detected, *SGOPN input is turned off.
NOTE The guard state is monitored, and the guard state signal (*VLDVx,*VLDPs) affects the dual check safety function. The illustrated sample system determines that the guard is open (sets *VLDVx and *VLDPs to 0) when the guard is unlocked. When the guard open request signal (ORQ) is accepted, CNC will negate the guard open inhibit signal (*OPIHB). Machine tool builder can create the signal to release the guard-lock by his ladder program, when the following conditions are met. *OPIHB=1, RSVx and RSPs to be refered=1 and the safety conditions of the machine
- 138 -
Page 147
10.SAMPLE SYSTEM CONFIGURATION
B-64004EN/02
10.2.5
MCC Off Signal (*MCF,*MCFVx,*MCFPs,*DCALM), MCC Contact State Signal (*SMC)
I/O Link #1 I/O UNIT X00n#n
+24V
Y00n#n
PMC#1 *SMC
*MCF *MCFVx, *MCFPs *DCALM
0V I/O UNIT#3 I/O UNIT X00n#n Y00n#n 0V
PMC#2 *SMC *MCF *MCFVx, *MCFPx *DCALM
PSM 200A 200B
CX3 MCC
U V W Electromagnetic contactor (MAIN MCC)
NOTE Only in case that all the signals (*MCF, *MCFVx, *MCFPx, *DCALM) of the PMC side are “1”, the signal which turns on the MCC should be asserted by the ladder program. Also in the DCS PMC side, similar logic should be made. Also connect the MCC control signal to PSM, as illustrated in the figure. If an error occurs in the PSM, the PSM turns off the MCC. Any equipment should not be connected on the 3- phase AC line between the MAIN MCC and PSM. CAUTION The MCC shall have forced guided contacts , and must fulfill the standard IEC60204 and IEC 60255. This is mandatory. - 139 -
Page 148
11.COMPONENTS LIST
11
B-64004EN/02
COMPONENTS LIST
- 140 -
Page 149
11.COMPONENTS LIST
B-64004EN/02
11.1
HARDWARE COMPONENTS
11.1.1
Hardware Components for Series 30i/300i/300is-MODEL A
CNC Control unit No. 1 Main board 2 CPU card
Description
3
Axes control card
4 5
PMC module FROM/SRAM module
6 7 8
Power supply unit Back Panel Back Panel
11.1.2
Specification Number A20B-8100-0980 A20B-3300-0471 A20B-3300-0470 A20B-3300-0473 A20B-3300-0474 A20B-3300-0477 A20B-3300-0440 A20B-3300-0442 A20B-3300-0445 A20B-3300-0447 A20B-3300-0448 A20B-3900-0200 A20B-3900-0160 A20B-3900-0161 A20B-3900-0163 A20B-3900-0164 A20B-3900-0183 A20B-3900-0180 A20B-3900-0181 A20B-3900-0182 A20B-8101-0010 A20B-2003-0610 A20B-2003-0600
Remarks
Hardware Components for Other Units
Other unit for CNC No. Description 1 Separate detector I/F unit (Basic 4 axes) 2 Separate detector I/F unit (Additional 4 axes) 3 I/O module for operator’s panel 4 I/O module for operator’s panel 5 6
I/O module for connector panel (Basic module) I/O module for connector panel (Extension module)
7 8 9 10
2A DO output module Analog input module Machine operator’s panel main panel I/O card
11 12
Control PCB for Machine operator’s panel 10 slots base Horizontal ABU10A
Specification Number A02B-0303-C205 A02B-0236-C204 A20B-2002-0470 A20B-2002-0520 A20B-2002-0521 A03B-0815-C001 A03B-0815-C002 A03B-0815-C003 A03B-0815-C004 A03B-0815-C005 A02B-0303-C231 A16B-2202-0730 A16B-2202-0731 A20B-8002-0020 A20B-9001-0040 A03B-0819-C001
- 141 -
Remarks
Page 150
11.COMPONENTS LIST No. Description 13 5 slots base Horizontal ABU05A 14
10 slots base Vertical ABU10B
15
5 slots base Vertical ABU05B
16
Interface AIF01A
17
Interface AIF01B
18
DC digital input AID32A1
19
DC digital input AID32B1
20
DC Digital input AID16D
21
DC Digital input AID16L
22
DC digital input AID32E1
23
DC digital input AID32F1
24
AC digital input AIA16G
25
DC digital input AID32F2
26
DC digital input AID32E2
27
DC digital input AID32H1
28
DC digital input AID16G
29
DC digital output AOD08D
30
DC digital output AOD16D
31
DC digital output AOD32D1
32
AC digital output AOA05E
33
AC digital output AOA08E
34
AC digital output AOA12F
35
Relay output AOR08G
36
Relay output AOR16G
37
Relay output AOR16H2
38
DC digital output AOD32D2
B-64004EN/02
Specification Number A20B-9001-0020 A03B-0819-C002 A20B-2000-0510 A03B-0819-C003 A20B-2003-0100 A03B-0819-C004 A20B-8000-0410 A03B-0819-C011 A20B-8000-0420 A03B-0819-C012 A20B-9000-0970 A03B-0819-C101 A20B-9000-0971 A03B-0819-C102 A20B-8002-0370 A03B-0819-C104 A20B-8002-0371 A03B-0819-C114 A20B-8002-0150 A03B-0819-C105 A20B-8002-0151 A03B-0819-C106 A20B-8000-0341 A03B-0819-C107 A20B-8002-0161 A03B-0819-C109 A20B-8002-0160 A03B-0819-C110 A20B-9000-0972 A03B-0819-C111 A20B-8000-0342 A03B-0819-C115 A20B-9001-0220 A03B-0819-C152 A20B-9000-0921 A03B-0819-C154 A20B-8000-0440 A03B-0819-C156 A20B-8000-0470 A03B-0819-C157 A20B-8000-0480 A03B-0819-C158 A20B-8000-0321 A03B-0819-C159 A20B-9001-0200 A03B-0819-C160 A20B-8000-0101 A03B-0819-C161 A20B-8000-0500 A03B-0819-C165 A20B-8000-0510 A03B-0819-C167
- 142 -
Remarks