Page 131

9.DIAGNOSIS

B-64004EN/02

9

DIAGNOSIS The diagnosis screen for the maintenance operation of the Dual Check Safety function is displayed in the group of [SYSTEM] screens. The operation to select the Dual Check Safety diagnosis screen is as a follows: (1) Press the [SYSTEM] key. (2) Press the continuous menu key [+] key several times then the [DUAL CHECK] soft key is displayed. (3) Press the [DUAL CHECK] soft key then the Dual Check Safety diagnosis screen is displayed. The state of MCC OFF TEST, the state of signals in case that the alarm related to safety occurs and the cause of alarm is displayed on the Dual Check Safety diagnosis screen.

- 123 -

Page 132

9.DIAGNOSIS

9.1

B-64004EN/02

MCC OFF TEST STATUS SCREEN By pressing [MCC TEST] soft key, the following MCC OFF TEST STATUS screen is displayed.

The following items are displayed for each machine group. Passing time from the last MCC OFF TEST Passing time from the last MCC OFF TEST is displayed. Count of time is stopped when reaching 24:00:00. 24:00:00 is displayed at power-on. MCC OFF TEST execution request The CNC system notifies that it is necessary to select MCC OFF TEST mode and check whether MCC off signal (*MCF) works normally or not. When the MCC OFF TEST execution request signal is turned to “1”, select MCC OFF TEST mode and execute MCC OFF TEST as soon as possible. Last number of test sequence The current sequence number of MCC OFF TEST is displayed. If MCC OFF TEST is finished normally, “0” is displayed. Refer to the section of “MCC OFF TEST” for further detail. Message When the power is turned on or 24 hours passes from the last MCC OFF TEST, this screen is selected and the message “EXECUTE MCC TEST” is displayed.

- 124 -

Page 133

9.DIAGNOSIS

B-64004EN/02

9.2

CROSS CHECK DATA SCREEN The CROSS CHECK DATA screen displays (1) [ALARM INFORMATION] SCREEN Press the [CROSS CHECK] soft key then the screen shown below appears. This screen shows the DI/DO status when the cross check alarm occurs.

(2) [DI SIGNAL STAUS] SCREEN Press the [PAGE DOWN] key and select the second page. The screen shown below appears. This screen shows the current DI status. If there is difference of DI state between PMC and DCS PMC, “#” is displayed on the left side of the address.

- 125 -

Page 134

9.DIAGNOSIS

B-64004EN/02

(3) [DO SIGNAL STATUS] SCREEN Press the [PAGE DOWN] key and select the third page. The screen shown below appears. This screen shows the current DO status. If there is difference of DO state between PMC and DCS PMC, “#” is displayed on the left side of the address.

(4) [SPINDLE STATUS] SCREEN Press the [PAGE DOWN] key and select the fourth screen. The screen shown below appears. When the judging result of safety function of CNC is not the same as other CPU, the cross check alarm occurs. This screen shows the cause of cross check alarm related to a spindle.

- 126 -

Page 135

9.DIAGNOSIS

B-64004EN/02

(5) [SERVO STATUS] SCREEN Press the [PAGE DOWN] key and select the fifth page. The screen shown below appears. When the judging result of safety function of CNC is not the same as other CPU, the cross check alarm occurs. This screen shows the cause of cross check alarm related to a servo motor.

- 127 -

Page 136

9.DIAGNOSIS

9.3

B-64004EN/02

FLOW MONITORING SCREEN The FLOW MONITORING screen displays Press the [+] continuous menu soft key. And press the [FLOW MONIT.] soft key. The screen shown below appears. This screen shows the counter for program flow monitoring.

If each safety function works normally, the present value shows the same value as the default.

- 128 -

Page 137

9.DIAGNOSIS

B-64004EN/02

9.4

FEED LIMIT MONITORING SCREEN (1) SERVO The data that are related to the safety limitation feed of the servo and the Dual Check Safety function are displayed. Press the FEED soft key. The screen shown below appears. LMT.

The following items (a) to (d) are displayed for every servo axis. (a) MNT. 0:Not Monitoring / 1:Monitoring (b) FEED LMT. In the safety limitation feed 1 to 4 (Set by the parameter No.13821 to No.13829), the safety limit feed that is selected by the Safety speed/Safety Position Selection signal A,B(SVAx,SVBx) is displayed (c) UNIT Unit of feed (Position control:D/sec Velocity control:min-1) (d) ACT. FEED Current actual feed rate(NC side and Servo side)

- 129 -

Page 138

9.DIAGNOSIS

B-64004EN/02

(2) SPINDLE The data that are related to the safety limitation feed of the spindle and the Dual Check Safety function are displayed. Press the [PAGE DOWN] key, the screen of the Safety limitation feed of the spindle shown below appears.

The following items (a) to (d) are displayed for every spindle axis. (a) MNT. 0:Not Monitoring / 1:Monitoring (b) FEED LMT. In the Safety feed limit 1 to 4 (Set by the parameter No.4372, 4442 to 4444), the safety limit feed that is selected by the Safety speed/Safety Position Selection signal A,B (SPAx, SPBx) is displayed (c) UNIT Unit of the feed (min-1) (d) ACT. FEED Current actual feed rate(NC side and Spindle side)

- 130 -

Page 139

9.DIAGNOSIS

B-64004EN/02

9.5

SAFE MACHINE POSITIONING MONITORING SCREEN The data that are related to the safe machine positioning monitoring of the Dual Check Safety function are displayed. Press the MCHN. soft key, The screen shown below appears. POS.

The following items (a) to (c) are displayed for every servo axis. (a) MNT. 0:Not Monitoring / 1:Monitoring/-: The reference position is not established (b) RANGE In the safety machine position 1 to 4 (Set by the parameter No.13830 to 13838), the upper limit value and lower limit value of the safety machine position that are selected by the Safety speed/Safety Position Selection signal A,B (SVAx, SVBx) are displayed (c) MCHN. POS. Current machine position (NC side and Spindle side)

- 131 -

Page 140

9.DIAGNOSIS

9.6

B-64004EN/02

SAFETY POSITION ERROR MONITORING SCREEN The data that are related to the safety position error monitoring of the Dual Check Safety function are displayed. Press the POS. soft key, The screen shown below appears. ERR.

The following items (a) to (c) are displayed for every servo axis. (a) MNT. 0:Not Monitoring / 1:Monitoring/-: The reference position is not established (b) LIMIT In the safety positioning error, the limit values corresponding to the current state (Stopping/Moving/Servo off) are displayed (c) POS. ERR. Current positioning error (NC side and Servo side)

- 132 -