Page 121
7.START-UP
B-64004EN/02 Parameter setting 1023 1240 1838 1839 1840 1841
1842
1904#6 1945 1946 1948 1950 3717 3797#0 4372 4438 4440 4442 4448 13821 13822 13823 13824 13825 13831 13832 13833 13834 13835 13836 13837 13838
Meaning Servo axis number of each axis Coordinates value of the reference position in the machine coordinate system Position deviation limit for each axis in moving state Position deviation limit for each axis in stopped state Position deviation limit for each axis in servo-off state Position deviation limit of each axis in moving state during other than Dual Check Safety monitoring (for Dual Check Safety Function) Position deviation limit of each axis in stopped state during other than Dual Check Safety monitoring (for Dual Check Safety Function) Enable safety function for each axis Timer for safety input signal check Timer for MCC off Test Timer 2 for MCC off Break signal timer Motor number to each spindle Enable safety function for each spindle Safety speed 1 on each spindle Safety speed 2 on each spindle Safety speed 3 on each spindle Safety speed 4 on each spindle Speed regarded as spindle stop for Dual Check Safety Safety speed 1 on each axis Safety speed 2 on each axis Safety speed 3 on each axis Safety speed 4 on each axis Speed regarded as axis stop for Dual Check Safety Safety position 1 (+ direction) on each axis Safety position 1 (- direction) on each axis Safety position 2 (+ direction) on each axis Safety position 2 (- direction) on each axis Safety position 3 (+ direction) on each axis Safety position 3 (- direction) on each axis Safety position 4 (+ direction) on each axis Safety position 4 (- direction) on each axis
Step 4 If alarm SV0478 or SV0496 occurs, set the parameter No.2212#4 is set to “1” and then set to “0”. Then turn off the CNC and the amplifier. And turn on the CNC and the amplifier.
Step 5 Execution of general machine tests Axis and spindle optimization Dual check safety function adjustment (safety limitation speed, safety machine position, Safe position error monitoring)
- 113 -
Page 122
7.START-UP
B-64004EN/02
Step 6 Test for checking the safety function Check test execution and report creation
Step 7 Parameter preservation Save all parameters including the safety parameters. parameters are used to start up the series.
The
Step 8 Set a password. A password is used to disable unauthorized persons from modifying safety parameters. Before safety parameters of the equipment for which a password (No. 3225) is set can be modified, the password value must be set as the keyword (No. 3226). Only those persons authorized to conduct a check test should know the password value.
7.2.2
Series start-up The parameters for the safety monitoring function are transferred together with other parameters to the CNC as in the case of normal series start-up. Perform a safety function check test in addition to the normal start-up procedure.
7.2.3
Troubleshooting Alarms related to the safety function are output on the ALARM screen. Correct the cause of trouble according to the chapter describing alarms and messages in this manual. When a component related to the safety function is to be replaced, an authorized person must conduct a safety function check test.
- 114 -
Page 123
8.ALARM MESSAGE
B-64004EN/02
8
ALARM MESSAGE
Alarm When Dual Check Safety function finds out some abnormal condition in safety check and generates an alarm, the alarm can be reset by reset operation if the abnormal condition is cleared. However, if the problem related with the system is found and an alarm is generated when unfit condition is found by double check function of signals or so on, alarm cannot be cancelled by a reset. In this case, to cancel the alarms, turn off the power.
- Servo Alarms (SV alarm) No.
Message
SV0474 EXCESS ERROR (STOP:SV) SV0475 EXCESS ERROR (MOVE:SV) SV0476 ILLEGAL SPEED CMD. (SV)
SV0477 ILLEGAL MACHINE POS.(SV)
SV0478 ILLEGAL AXIS DATA (SV)
Description The Servo detected that the positional deviation during stopping exceeded the parameter (No. 1839, No.1842) setting value. The Servo detected that the positional deviation during traveling exceeded the parameter (No. 1838, No.1841) setting value The Servo detected that the specified speed on the axis exceeded the safety speed (parameter No. 13821 to 13824, No. 13826 to 13829) during safety monitoring (the safety check request signal (*VLDVx) is 0). When the guard is open, confirm a proper value is set to parameter (No. 13821 to 13824, No. 13826 to 13829), and the operation is done within the safety speed. The Servo detected that the machine position on the axis is not in the safety area (parameter No.13831 to 13838) during safety monitoring (the safety check request signal (*VLDVx) is 0). When the guard is open, confirm a proper value is set to parameter No.13831 to 13838 and do an operation in the safety area. The safe machine position monitoring is done after the machine reference position is established. The Servo detected that an error occurred on the axis during axis data transfer. If the alarm occurs after performing axis number setting for the servo amplifier, set parameter No.2212#4 to 1, and reset the bit to 0, and then turn off the power to the entire system. In the other case, replace the servo amplifier if the alarm occurred.
SV0481 SAFETY PARAM ERROR(SV)
Error detected for safety parameter check function by Servo.
SV0484 SAFETY FUNCTION ERROR (SV)
An error occurred in safety functions of Servo: 1. The Servo or CNC detected the inexecution of servo software safety functions. 2. A mismatch between the servo software results of the safety functions and the CNC results of them occurred. 3. An error occurred in a servo CPU test. 4. An error occurred in a servo RAM test. In case of 1, 3 and 4, replace the axis control card. MCC off Test was not completed within the specified time (parameter No. 1946). Check the MCC contact.
SV0488 SELF TEST OVER TIME
- 115 -
Page 124
8.ALARM MESSAGE No.
B-64004EN/02
Message
SV0489 SAFETY PARAM ERROR(CNC)
Description Error for safety parameter check function is detected on n-th axis by CNC.
SV0490 SAFETY FUNCTION ERROR (CNC) An error occurred in safety functions of CNC: 1. The Servo detected the inexecution of CNC safety functions. 2. A mismatch between the CNC results of the safety functions and the Servo results of them occurred. Replace the CPU card. SV0494 ILLEGAL SPEED CMD. (CNC) The CNC detected that the specified speed exceeded the setting (parameter No. 13821 to 13824 in case of position control, No. 13826 to 13829 in case of velocity control) during safety monitoring (the safety check request signal(*VLDVx) is 0). When the guard is open, confirm a proper value is set to parameter (No. 13821 to 13824, No. 13826 to 13829), and the operation is done within the safety speed. SV0495 ILLEGAL MACHINE POS.(CNC) The CNC detected that the machine position is not in the safety area (parameter No.13831 to 13838) during safety monitoring (the safety check request signal(*VLDVx) is 0). When the guard is open, confirm proper values is set to parameter No. No.13831 to 13838, and operation is done in the safety area. The safe machine position monitoring is done for the axis whose machine reference position is established. SV0496 ILLEGAL AXIS DATA (CNC) The CNC detected that an error occurred during axis data transfer. If the alarm occurs after performing axis number setting for the servo amplifier, set parameter No.2212#4 to 1, and reset the bit to 0, and then turn off the power to the entire system. In the other case, replace the servo amplifier where the alarm occurred. SV0498 AXIS NUMBER NOT SET (CNC) The CNC detected that the axis number is not set with the servo amplifier. Turn off the power to the entire system. Then an axis number is automatically set. SV1068 DUAL CHECK SAFTY ALARM The alarm which shut off the MCC(system common) occurred in the dual check safety function. SV1069 EXCESS ERROR (SERVO OFF: The CNC detected that the positional deviation at servo off time CNC) exceeded the parameter (No. 1840) setting value. SV1070 EXCESS ERROR (SERVO OFF:SV The Servo detected that the positional deviation at servo off time DSP) exceeded the parameter (No. 1840) setting value. SV1071 EXCESS ERROR (MOVE: CNC) The CNC detected that the positional deviation during moving exceeded the parameter (No.1838, No.1841) setting value. SV1072 EXCESS ERROR (STOP:CNC) The CNC detected that the positional deviation during stopping exceeded the parameter (No.1839, No.1842) setting value.
- Spindle Alarms (SP alarm) No.
Message
SP0755 SAFETY FUNCTION ERROR
SP0756 ILLEGAL AXIS DATA
Description An error occurred in safety functions of the n-th spindle: ・The CNC detected that the safely function of the n-th spindle was not executed. ・A mismatch between the CNC results of the safety functions and the Spindle results of them occurred. The CNC CPU detected that the connection state and the hardware setting of the spindle amplifier were incompatible on the n-th spindle. If an alarm occurs because of the configuration change of the spindle amplifier, set the spindle amplifier correctly.
- 116 -
Page 125
8.ALARM MESSAGE
B-64004EN/02
No.
Message
SP0757 SAFETY SPEED OVER
SP1700 SAFETY PARAM ERROR
Description The CNC CPU detected that during safety monitoring (the safety check request signal(*VLDPs) is 0), the spindle motor speed was greater than the safety speed (parameter No. 4372, 4438, 4440, or 4442) on the n-th spindle. Operate within the safety speed. The CNC CPU detected error in safety parameter check function.
- Alarms requiring power to be turned off (PW alarm) No. PW0008 PW0009
Message CPU SELF TEST ERROR(DCS PMC) CPU SELF TEST ERROR(PMC)
PW0010
SAFE I/O CROSS CHECK ERROR(DCS PMC) PW0011 SAFE I/O CROSS CHECK ERROR(PMC) PW0012 USER I/O CROSS CHECK ERROR(DCS PMC) PW0013 USER I/O CROSS CHECK ERROR(PMC) PW0014 CPU TEST ALARM (CNC) PW0015 SAFETY PARAM ERROR PW0016 RAM CHECK ERROR PW0017 INEXECUTION OF SAFETY FUNCTIONS PW0018 CRC CHECK ERROR
Description The DCS PMC detected the error in the CPU self test function and RAM check function. The PMC detected the error in the CPU self test function and RAM check function. The DCS PMC detected the error of system define safe I/O in the I/O cross check function. The PMC detected the error of system define safe I/O in the I/O cross check function. The DCS PMC detected the error of user define safe I/O in the I/O cross check function. The PMC detected the error of user define safe I/O in the I/O cross check function. An error occurred in a CNC CPU test. The CNC detected error for safety parameter check function. The CNC detected error in RAM check function. The CNC detected abnormal condition in the execution of CNC safety functions. The CNC detected the CRC check error in the CNC ROM.
- Other alarms (DS alarm) No. DS0022
Message DUAL CHECK SAFETY IS NOT WORKED
Description Dual Check Safety function is unavailable by setting a parameter No.1902#6 to 0.
- 117 -
Page 126
8.ALARM MESSAGE
B-64004EN/02
- Serial Spindle Alarms No.
Message
SP indication
SP9016 SSPA:16 RAM ERROR SP9069 SAFETY SPEED OVER
16
SP9070 ILLEGAL AXIS DATA
70
SP9071 SAFETY PARAM ERROR
71
SP9072 MISMATCH RESULT OF MOTOR SPEED CHECK SP9074 CPU TEST ERROR
72
69
Faulty location and remedy
Description
Replace the SPM unit.
An error occurred in a spindle RAM test. Replace spindle amplifier module. The spindle detected that the speed of the 1 Check the safety speed parameter (parameter No.4372/ spindle motor exceeded the safety speed (parameter No. 4372/No.4438/No.4440 No.4438/No.4440 /No.4442). 2 Perform operation at a speed /No.4442) during safety monitoring (the not exceeding the safety speed. safety check request signal (*VLDPs) is 0). The spindle detected a mismatch between 1 Check the spindle amplifier the spindle amplifier connection state and connection state and spindle spindle amplifier hardware setting. amplifier hardware setting. 2 If this alarm is issued because If this alarm is issued because the spindle amplifier configuration is changed, correct the spindle amplifier configuration is changed, correct the setting on the spindle amplifier side. the setting on the spindle amplifier side. Set the safety parameter again. The spindle detected a safety parameter The following are spindle safety error. parameters. (No.4372/No.4438 /No.4440/No.4442/No.4448) Replace the SPM control The spindle detected a mismatch between printed-circuit board. the CNC result of the motor speed check and the spindle result of it.
74
Replace the SPM control printed-circuit board.
An error occurred in a spindle amplifier CPU test.
75
Replace the SPM control printed-circuit board. Replace the SPM control printed-circuit board.
An error occurred in a spindle ROM CRC test. Any safety function was not executed.
Replace the SPM control printed-circuit board.
The spindle detected a mismatch between the CNC result of the axis number check and the spindle result of it.
Set the safety parameter again. The following are spindle safety parameters. (No.4372/No.4438 /No.4440/No.4442/No.4448) Replace the SPM control printed-circuit board.
The spindle CPU detected a mismatch between the CNC result of the safety parameters check and the spindle result of it. The safety functions at power-up for spindle were not executed.
SP9076 INEXECUTION OF 76 SAFETY FUNCTIONS SP9077 MISSMATCH THE 77 RESULTS OF AXIS NUMBER CHECK SP9078 MISSMATCH THE 78 RESULTS OF SAFETY PARAMETER 79
- Boot System Alarms Message
Description
CRC CHECK ERROR:NC BASIC.
CRC error occurs in CNC BASIC ROM. Please install CNC BASIC ROM in flash memory again.
- 118 -
Page 127
8.ALARM MESSAGE
B-64004EN/02
- Servo Alarms to turn MCC off Signal (*MCFVx) to “0” In case that the parameter No.10500#0 (AVM) is set to “0”, the MCC off Signal (*MCFVx) of an alarm axis is turned to “0” immediately when the alarm related to data communication or detector occurs. The following table shows this kind of servo alarm. Number
Message
SV0301
APC ALARM: COMMUNICATION ERROR
SV0302
APC ALARM: OVER TIME ERROR
SV0303
APC ALARM: FRAMING ERROR
SV0304
APC ALARM: PARITY ERROR
SV0305
APC ALARM: PULSE ERROR
SV0306
APC ALARM: OVER FLOW ERROR
SV0307 SV0360 SV0361 SV0362 SV0363 SV0364 SV0365
APC ALARM: MOVEMENT EXCESS ERROR ABNORMAL CHECKSUM(INT) ABNORMAL PHASE DATA(INT) ABNORMAL REV. DATA(INT) ABNORMAL CLOCK(INT) SOFT PHASE ALARM(INT) BROKEN LED(INT)
SV0366 SV0367 SV0368
PULSE MISS(INT) COUNT MISS(INT) SERIAL DATA ERROR(INT)
SV0369
DATA TRANS. ERROR(INT)
SV0380 SV0381
BROKEN LED(EXT) ABNORMAL PHASE (EXT)
SV0382 SV0383 SV0384
COUNT MISS(EXT) PULSE MISS(EXT) SOFT PHASE ALARM(EXT)
SV0385
SERIAL DATA ERROR(EXT)
SV0386
DATA TRANS. ERROR(EXT)
Description Since the absolute-position detector caused a communication error, the correct machine position could not be obtained. (data transfer error) The absolute-position detector, cable, or servo interface module is thought to be defective. Since the absolute-position detector caused an overtime error, the correct machine position could not be obtained. (data transfer error) The absolute-position detector, cable, or servo interface module is thought to be defective. Since the absolute-position detector caused a framing error, the correct machine position could not be obtained. (data transfer error) The absolute-position detector, cable, or servo interface module is thought to be defective. Since the absolute-position detector caused a parity error, the correct machine position could not be obtained. (data transfer error) The absolute-position detector, cable, or servo interface module is thought to be defective. Since the absolute-position detector caused a pulse error, the correct machine position could not be obtained. The absolute-position detector or cable is thought to be defective. Since the amount of positional deviation overflowed, the correct machine position could not be obtained. Since the machine moved excessively, the correct machine position could not be obtained. The checksum alarm occurred on the built–in Pulsecoder. The phase data abnormal alarm occurred on the built–in Pulsecoder. The speed count abnormal alarm occurred on the built-in Pulsecoder. The clock alarm occurred on the built–in Pulsecoder. A digital servo soft detected an abnormality on the built in Pulsecoder. The digital servo software detected abnormal data on the built–in Pulsecoder. A pulse error occurred on the built–in Pulsecoder. A count error occurred on the built–in Pulsecoder. The communications data could not be received from the built–in Pulsecoder. A CRC error or stop bit error occurred in the communications data from the built–in Pulsecoder. Separate detector error An abnormal alarm in the position data occurred on the separate linear scale. A count error occurred on the separate detector. A pulse error occurred on the separate detector. The digital servo software detected abnormal data on the separate detector. The communications data could not be received from the separate detector. A CRC error or stop bit error occurred in the communications data from the standalone detector.
- 119 -
Page 128
8.ALARM MESSAGE Number
B-64004EN/02
Message
SV0387
ABNORMAL ENCODER(EXT)
SV0445 SV0448
SOFT DISCONNECT ALARM UNMATCHED FEEDBACK ALARM
SV0453
SPC SOFT DISCONNECT ALARM
SV0460
FSSB DISCONNECT
SV0462
SEND CNC DATA FAILED
SV0463
SEND SLAVE DATA FAILED
SV0474
EXCESS ERROR(STOP:SV )
SV0475
EXCESS ERROR(MOVE:SV)
SV1067
FSSB:CONFIGURATION ERROR(SOFT)
SV5134
FSSB:OPEN READY TIME OUT
SV5136
FSSB:NUMBER OF AMP. IS INSUFFICIENT
SV5137
FSSB:CONFIGURATION ERROR
SV5139
FSSB : ERROR
SV5197
FSSB:OPEN TIME OUT
SV5311
FSSB:ILLEGAL CONNECTION
Description An abnormality occurred on a separate detector. For more information, contact the scale manufacturer. The digital servo software detected a disconnected Pulsecoder. The sign of the feedback signal from the standalone detector is opposite to that from the feedback signal from the built–on Pulsecoder. Software disconnection alarm of the α pulse coder. Turn off the power to the CNC, then remove and insert the pulse coder cable. If this alarm is issued again, replace the pulse coder. The FSSB connection was discontinued. Or, the FSSB connection cable was disconnected or broken. The amplifier was turned off. In the amplifier, the low-voltage alarm occurred. The correct data could not be received on a slave side because of the FSSB communication error. The correct data could not be received in the servo software because of the FSSB communication error. The Servo detected that the positional deviation during stopping exceeded the parameter (No. 1839, No.1842) setting value. The Servo detected that the positional deviation during traveling exceeded the parameter (No. 1838, No.1841) setting value. The FSSB configuration error occurred. (Detected in software). Or, there is a difference in the type of connected amplifier and FSSB setting. In the initialization, the FSSB could not be in an open ready sate. The axis card is thought to be defective. The number of amplifier identified by the FSSB is insufficient than the number of control axes. Or, the setting of the number of axes or the amplifier connection is in error. An FSSB configuration error occurred. The connecting amplifier type is incompatible with the FSSB setting value. Servo initialization did not terminate normally. The optical cable may be defective, or there may be an error in connection to the amplifier or another module. Check the optical cable and the connection status. The initialization of the FSSB was completed, but it could not be opened. Or, the connection between the CNC and the amplifier in is incorrect. 1. This alarm is issued if axes, whose servo axis numbers (parameter No. 1023) are even and odd numbers, are allocated to the amplifiers connected to the FSSBs of different paths. 2. This alarm is issued if an attempt is made to set up for use of the pulse modules connected to the FSSBs of different paths. And the system did not satisfy the requirements for performing HIGH SPEED HRV control.
- 120 -
Page 129
8.ALARM MESSAGE
B-64004EN/02
- Spindle Alarms to turn MCC off Signal (*MCFPs) to “0” In case that the parameter No.10500#1 (APM) is set to “0”, the MCC off Signal (*MCFPs) of an alarm spindle is turned to “0” immediately when the alarm related to data communication or detector occurs. The following table shows this kind of spindle alarm. Number SP1220 SP1225 SP1226 SP1227 SP1228 SP1229 SP1245 SP1246 SP1247 SP1976 SP1977 SP1978 SP1979 SP1980 SP1981 SP1982 SP1983 SP1987 SP9073 SP9081 SP9082 SP9083
Message
Description
NO SPINDLE AMP.
Either the cable connected to a serial spindle amplifier is broken, or the serial spindle amplifier is not connected. CRC ERROR (SERIAL SPINDLE) A CRC error (communications error) occurred in communications between the CNC and the serial spindle amplifier. FRAMING ERROR (SERIAL A framing error occurred in communications between the CNC and the SPINDLE) serial spindle amplifier. RECEIVING ERROR (SERIAL A receive error occurred in communications between the CNC and the SPINDLE) serial spindle amplifier. COMMUNICATION ERROR (SERIAL A communications error occurred between the CNC and the serial SPINDLE) spindle amplifier. COMMUNICATION ERROR SERIAL A communications error occurred between serial spindle amplifiers SPINDLE AMP. (motor Nos. 1 and 2, or motor Nos. 3–4). COMMUNICATION DATA ERROR A communication data error was detected on the CNC. COMMUNICATION DATA ERROR A communication data error was detected on the CNC. COMMUNICATION DATA ERROR A communication data error was detected on the CNC. SERIAL SPINDLE COMMUNICATION The amplifier No. could not be set to the serial spindle amplifier. ERROR SERIAL SPINDLE COMMUNICATION An error occurred in the spindle control software. ERROR SERIAL SPINDLE COMMUNICATION A time–out was detected during communications with the serial spindle ERROR amplifier. SERIAL SPINDLE COMMUNICATION The communications sequence was no longer correct during ERROR communications with the serial spindle amplifier. SERIAL SPINDLE AMP. ERROR Defective SIC–LSI on serial spindle amplifier SERIAL SPINDLE AMP. ERROR An error occurred during reading of the data from SIC–LSI on the analog spindle amplifier side. SERIAL SPINDLE AMP. ERROR An error occurred during reading of the data from SIC–LSI on the serial spindle amplifier side. SERIAL SPINDLE AMP. ERROR Could not clear on the spindle amplifier side. SERIAL SPINDLE CONTROL ERROR Defective SIC–LSI on the CNC MOTOR SENSOR DISCONNECTED The motor sensor feedback signal is not present. 1-ROT MOTOR SENSOR ERROR The one-rotation signal of the motor sensor cannot be correctly detected. NO 1-ROT MOTORSENSOR The one-rotation signal of the motor sensor is not generated. MOTOR SENSOR SIGNAL ERROR An irregularity was detected in a motor sensor feedback signal.
- 121 -
Page 130
8.ALARM MESSAGE
B-64004EN/02
Reference of Dual Check Alarm message Dual Check Alarm by Servo CPU and CNC CPU No. SV0474 SV0475 SV0476 SV0477 SV0478 SV0481 SV0484 SV1070
Message (Servo)
No.
EXCESS ERROR(STOP:SV ) EXCESS ERROR(MOVE:SV) ILLEGAL SPEED CMD.(SV ) ILLEGAL MACHINE POS.(SV) ILLEGAL AXIS DATA(SV) SAFETY PARAM ERROR(SV) SAFETY FUNCTION ERROR(SV) EXCESS ERROR(SERVO OFF:SV)
SV1072 SV1071 SV0494 SV0495 SV0496 SV0489 SV0490 SV1069
Message (CNC) EXCESS ERROR(STOP:CNC) EXCESS ERROR(MOVE:CNC) ILLEGAL SPEED CMD.(CNC) ILLEGAL MACHINE POS.(CNC) ILLEGAL AXIS DATA(CNC) SAFETY PARAM ERROR(CNC) SAFETY FUNCTION ERROR(CNC) EXCESS ERROR(SERVO OFF:CNC)
Dual Check Alarm by Spindle CPU and CNC CPU No.
Message (Spindle)
No.
Message (CNC)
SP9069 (69) SP9070 (70) SP9071 (71)
SAFETY SPEED OVER
SP0757
SAFETY SPEED OVER
ILLEGAL AXIS DATA
SP0756
ILLEGAL AXIS DATA
SAFETY PARAM ERROR
SP1700
SAFETY PARAMETER ERROR
SP9072 (72) SP9076 (76)
MISMATCH RESULT OF MOTOR SPEED CHECK INEXECUTION OF SAFETY FUNCTIONS
SP0755
SAFETY FUNCTION ERROR
SP9077 (77)
MISMATCH RESULT OF AXIS NUMBER CHECK
SP9078 (78)
MISMATCH RESULT OF SAFETY PARAMETER
Dual Check Alarm by PMC CPU and CNC CPU (Power must be off) No.
Message (PMC)
No.
Message (CNC)
PW0008 PW0010 PW0012
CPU SELF TEST ERROR(DCS PMC) SAFE I/O CROSS CHECK ERROR(DCS PMC) USER I/O CROSS CHECK ERROR(DCS PMC)
PW0009 PW0011 PW0013
CPU SELF TEST ERROR(PMC) SAFE I/O CROSS CHECK ERROR(PMC) USER I/O CROSS CHECK ERROR(PMC)
- 122 -