Page 111
6.PARAMETERS
B-64004EN/02
[Valid data range]
9 digits of minimum unit of data (Refer to standard parameter setting table(A). But in case that CMR≥1, data range becomes 1/CMR of 9 digits of minimum unit of data.) (When the increment system is IS-B and CMR=1, -999999.999 to +999999.999) (When the increment system is IS-B and CMR=2, -499999.999 to +499999.999)
NOTE Whether to specify this parameter by using a diameter value or radius value depends on whether the corresponding axis is based on diameter specification or radius specification. These parameters set the minimum operation range of the 1st through 64th safe position switches.
CAUTION 1 When the machine position is on the boundary of the specified ranges (machine position = parameter setting value), it is considered within the specified ranges. 2 When the setting of operation range is “maximum operation range < minimum operation range”, the safe position switch is not output. 3 If parameter No.13960 to No.13991, No.10565 to No.10596 are changed, please turn the power of the machine off once.
- 103 -
Page 112
6.PARAMETERS
B-64004EN/02
11950
1st byte address of Safety input signal for CNC CPU
11951
2nd byte address of Safety input signal for CNC CPU
: 11957
8th byte address of Safety input signal for CNC CPU
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input 2-Word 0 to 3999999 These parameters set the address of the 1st through 8th double checked input signals of CNC CPU (DCS PMC). Setting value = TYPE + ADRS ADRS = Byte address TYPE 0 1000000 2000000 3000000
Meaning This signal is not checked. X address R address D address
Ex.) X8 : setting value = 1000008 R8 : setting value = 2000008 11960
1st byte address of Safety output signal for CNC CPU
11961
2nd byte address of Safety output signal for CNC CPU
: 11967
8th byte address of Safety output signal for CNC CPU
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input 2-word 0 to 3999999 These parameters set the address of the 1st through 8th double checked output signals of CNC CPU(DCS PMC). Setting value = TYPE + ADRS ADRS = Byte address TYPE 0 1000000 2000000 3000000
Meaning This signal is not checked. Y address R address D address
Ex.) Y8 : setting value = 1000008 R8 : setting value = 2000008 - 104 -
Page 113
6.PARAMETERS
B-64004EN/02
11970
1st byte address of Safety input signal for PMC CPU
11971
2nd byte address of Safety input signal for PMC CPU
: 11977
8th byte address of Safety input signal for PMC CPU
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input 2-word 0 to 303999999 These parameters set the address of the 1st through 8th double checked input signals of PMC CPU. Setting value = TYPE + ADRS ADRS = Byte address TYPE 0 101000000 102000000 103000000 104000000 201000000 202000000 203000000 204000000 301000000 302000000 303000000
Meaning This signal is not checked X address of 1st PMC R address of 1st PMC D address of 1st PMC E address of 1st PMC X address of 2nd PMC R address of 2nd PMC D address of 2nd PMC E address of 2nd PMC X address of 3rd PMC R address of 3rd PMC D address of 3rd PMC
Ex.) X8 of 1sr PMC : setting value = 101000008 X8 of 2nd PMC: setting value = 201000008
- 105 -
Page 114
6.PARAMETERS
B-64004EN/02
11980
1st byte address of Safety output signal for PMC CPU
11981
2nd byte address of Safety output signal for PMC CPU
: 11987
8th byte address of Safety output signal for PMC CPU
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input 2-word 0 to 303999999 These parameters set the address of the 1st through 8th double checked output signals of PMC CPU. Setting value = TYPE + ADRS ADRS = Byte address TYPE 0 101000000 102000000 103000000 104000000 201000000 202000000 203000000 204000000 301000000 302000000 303000000
Meaning This signal is not checked Y address of 1st PMC R address of 1st PMC D address of 1st PMC E address of 1st PMC Y address of 2nd PMC R address of 2nd PMC D address of 2nd PMC E address of 2nd PMC Y address of 3rd PMC R address of 3rd PMC D address of 3rd PMC
Ex.) Y8 of 1st PMC: setting value = 101000008 Y8 of 2nd PMC: setting value = 201000008
- 106 -
Page 115
6.PARAMETERS
B-64004EN/02
6.6
PROFIBUS-DP parameter settings PROFIBUS DI/DO signals can be assigned to Dual Check Safety PMC per each slot unit. To configure PROFIBUS parameters, please refer to “Chapter II.SETTING” of “FANUC PROFIBUS-DP board (for Series 30i-MODEL-A) Operator’s manual / B-63994EN”. The following is the additional information relating to Dual Check Safety function.
Assigning PROFIBUS DI/DO signals to Dual Check Safety PMC Assigning PROFIBUS DI/DO signals to Dual Check Safety PMC can be set up as follows. 1. Press soft key [DI/DO ADDR] to display the DI/DO ADDRESS screen. 2. Set the DI/DO addresses (DI ADDR and DO ADDR) according to the following format. S : <PMC-address> For R0500 of Dual Check Safety PMC, for example, “S:R0500” must be entered. X and R address is available to DI ADDRess. Y and R address is available to DO ADDRess. If there is no “:” key in your CNC unit, it is substituted with the “/” or “EOB” key.
Broken wire detection “Broken wire detection” enables slaves to monitor the communication interval, detect the communication error when a slave cannot receive data from the Master, and clear the DO data which is received from Master. “Broken wire detection” and “Watchdog time” are configured with Slave parameters which are transferred from Master to Slaves during initialization. When PROFIBUS-DP signal is used for Dual Check Safety, please activate “Broken wire detection”. - 107 -
Page 116
6.PARAMETERS
B-64004EN/02
“Watchdog time” should be set to several times longer than the refresh time in consideration of re-transmission. The refresh time can be observed in STATUS INFORMATION screen of PROFIBUS setting screen. “Broken wire detection” and “Watchdog time” can be configured in PROFIBUS setting screen. When “1” is set into “WD”, “Broken wire detection” becomes active. “Watchdog time” is calculated with the following expression. 10 x WD_FACT1 x WD_FACT2 (ms) For example, in the following setting, “Broken wire detection” will activate when a watchdog time of 250ms expires.
- 108 -
Page 117
7.START-UP
B-64004EN/02
7
START-UP
- 109 -
Page 118
7.START-UP
7.1
B-64004EN/02
START-UP OPERATION The machine tool builder has to do tests for insulation and protective bonding. Testing must be performed according to Chapter 19.2 and 19.3 of the standard IEC 60204-1 by an appropriately authorized person and recorded.
Continuity of the protective bonding circuit When the machine is installed and the electrical connections are complete, including those to the power supply, the continuity of the protective bonding circuit can be verified by a loop impedance test in accordance with 612.6.3 of IEC 60364-6-61. For further details, please refer to Chapter 19.2 of IEC 60204-1.
Insulation resistance tests The insulation resistance measured at 500 V d.c. between the power circuit conductors and the protective bonding circuit is to be not less than 1 M Ω. For further details, please refer to Chapter 19.3 of IEC 60204-1.
7.1.1
Acceptance test and report for safety functions
Acceptance test for Safety function The machine tool builder is to conduct a dual check safety function check test during machine start-up operation. In this test, limits need to be exceeded to check that the dual check safety function operates normally.
Acceptance report A qualified person is to check each dual check safety function and record the test results in a check report.
NOTE When modifying dual check safety function data, conduct an additional check test on the modified dual check safety function and record the test results in a check report.
Safety-related I/O monitoring test Data cross-check operation is tested with the I/O device connector detached.
MCC off Test check The test mode signal is used to check that a MCC off Test is conducted. Negative test: Conduct a MCC off Test by disconnecting the MCC contact signal (input). Check that an alarm is issued and the MCC remains to be shut off. - 110 -
Page 119
7.START-UP
B-64004EN/02
Safety limitation speed monitoring test This test checks that when the actual speed exceeds a speed limit, safety stop state is set by a stop response.
Safety machine position monitoring test A positional limit test is conducted by making many different movements. A positional limit is placed at the center of an axis, and the position is moved at many different speeds in a rapid traverse mode. Thus, the distance traveled on the axis until stop state is set by a stop response is measured. The machine tool builder is to determine a safety limit stop position including a safety margin.
Data modification The user needs to enter the correct password before setting safety parameters with the system. After a safety parameter is modified, a check test needs to be conducted on the related safety function, and the test results need to be recorded in a report.
- 111 -
Page 120
7.START-UP
B-64004EN/02
7.2
START-UP OF THE SAFETY FUNCTION
7.2.1
Initial start-up
Main flow Disable dual check safety Machine start-up
Safety related I/O setting
Safety parameter input
Step 1 Initial state First, check that the machine starts up normally when the dual check safety function is disabled. Preparation 1 Preparation 2
Disable the dual check safety function. Wire to control the MCC
Bit 6 (DCE) of PRM No. 1902 = 0 Connect the relay to control MCC with I/O output
NOTE When the dual check safety function is disabled, the MCC Off signal (*DCALM, *MCFVx, *MCFPs) is set to “1”. (The MCC Off signal (*MCF) is changed according to the emergency stop signal. ) So, make a ladder program to output DO signal to control the relay for the MCC control according to the MCC Off signal.
Step 2 DCS PMC side I/O setting Make the settings as for the I/O Link#3,#4 or Profibus. Make a ladder program for the safe related I/O. (PMC/DCS PMC) In case Profibus is used, please refer to the sub-section “5.6 Assignment of PROFIBUS DI/DOs to Dual Check Safety PMC”
Step 3 Safety parameter input Enable the dual check safety function, and enter the safety parameters. Preparation 1
Enable the dual check safety function.
Bit 6 of PRM No. 1902 = 1
Set the safety parameters indicated in the table below. Parameter setting 980 981 982
- 112 -
Meaning Machine group number of each path Absolute path number of each axis Absolute path number of each spindle