Page 101
6.PARAMETERS
B-64004EN/02
#7
#6
#5
10500
[Input type] [Data type]
#4
#3 STP
#2
#1
#0
APM
AVM
Parameter input Bit path
NOTE When this parameter is set, the power must be turned off before operation is continued. #0
AVM
In case that a servo alarm occurs, 0: MCC off signal (*MCFVx) is turned to “0” when some servo alarm occurs. 1: MCC off signal (*MCFVx) is turned to “0” when any servo alarm occurs. In case that this parameter is set to “1”, MCC off signal (*MCFVx) of all axes, which belong to the same path as the alarm axis, are turned to “0” when a servo alarm occurs.
#1
APM
In case that a spindle alarm (SPxxxx) occurs 0: MCC off signal (*MCFPs) is turned to “0” when some spindle alarm occurs. 1: MCC off signal (*MCFPs) is turned to “0” when any spindle alarm occurs. In case that this parameter is set to “1”, MCC off signal (*MCFPs) of all spindles, which belong to the same path as the alarm spindle, are turned to “0” when a spindle alarm occurs.
#3
STP
When the power is turned on, a MCC off test is: 0: Carried out. (The screen is changed to Dual Check Safety Diagnosis screen automatically and the warning "EXECUTE MCC TEST" is displayed at power-on, and MCC off Test execution request signal (RQT) is output.) 1: Not carried out.
- 93 -
Page 102
6.PARAMETERS
B-64004EN/02
CAUTION 1 The STP parameter is used temporarily, for example, when a MCC off Test is not to be made at power-on as in the case of machine adjustment. 2 After adjustment, set STP = 0. 3 Even when STP = 1, a MCC off Test is required if the power is turned 24 hours or more after the completion of the previous MCC off Test. 4 The same value must be set to the path that belongs to the same machine group. 5 The screen is changed to “ALARM SCREEN” when an alarm occurs at power-on. In this case, Dual Check Safety Diagnosis screen is not displayed at power-on automatically. 13810
Timer to start safety I/O signal after power-on
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]
13811
Parameter input Word msec 0 to 32767 In Dual Check Safety function, the time from “CNC start-up” to “I/O cross check error start” is specified just after power-on. Hysteresis width of position switch (Dual Check Safety)
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Least unit of data] [Valid data range]
Parameter input Real axis mm, inch, deg (Machine unit) According to the input increment of corresponding axis 0 or positive 9 digit of least input increment of data (Refer to standard parameter setting table(B). But in case that CMR≥1, data range becomes 1/CMR of 9 digits of least input increment of data.) (When the increment system is IS-B and CMR=1, 0 to +999999.999) (When the increment system is IS-B and CMR=2, 0 to +499999.999)
NOTE Whether to specify this parameter by using a diameter value or radius value depends on whether the corresponding axis is based on diameter specification or radius specification. - 94 -
Page 103
6.PARAMETERS
B-64004EN/02
Position switch sometimes turns on and off repeatedly near the boundary of position switch area by very small vibration of a servo motor. According to this problem, position switch is inconvenient to use. So “hysteresis” described below is applied.
Maximum limit of position switch
Minimum limit of position switch
Width of hysteresis Width of hysteresis Activated area of position switch
Fig.6.5(a) Measuring area of position switch in case state of switch is “0” Minimum limit of position switch
Maximum limit of position switch
Activated area of position switch
Fig.6.5(b) Measuring area of position switch in case state of switch is “1”
The position switch is checked at every sampling period. When the minimum and maximum limit of position switch are given like above figure, activated area is checked by the area shown in the figure 6.5(a) considering hysteresis if the state of position switch measured at last time is “0”. And activated area is checked by the area shown in the figure 6.5(b) not considering hysteresis if the state of position switch measured at last time is “1”. According to this, it is possible to suppress frequent changing of position switch.
13821
Safety limit speed 1 in position control for each axis
13822
Safety limit speed 2 in position control for each axis
13823
Safety limit speed 3 in position control for each axis
13824
Safety limit speed 4 in position control for each axis
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Minimum unit of data]
Parameter input Real axis mm/min, inch/min, degree/min (machine unit) Depend on the increment system of the applied axis - 95 -
Page 104
6.PARAMETERS
B-64004EN/02
[Valid data range]
Refer to the standard parameter setting table (C) (When the increment system is IS-B, 0.0 to +240000.0) Set a safety speed for each axis in position control. CNC and Servo always check the velocity command of each axis in Dual Check Safety function. If the speed is exceeded the safety limit even on one axis, Monitoring Result signal (RSVx) corresponding to that axis is set to “0”. Moreover if Safety Check request signal (*VLDVx) is set to “0”, an alarm SV0476 or SV0494 is generated for the corresponding axis. A safety speed parameter for each axis in feed control is from No.13826 to No.13829. Up to 4 safety speed can be specified. Safety speed is selected by Safety Speed / Safety Position Selection signal (SVAx/SVBx). As for the detail of Safety Speed / Safety Position Selection signal, refer to the description about Safety Speed / Safety Position Selection signal.
CAUTION 1 The safety speed checks are made on the basis of the speed converted to the detection unit. Accordingly, a calculation error may occur. 2 After safety speed parameters No.13821 to No.13824 have been set, the power must be turned off then back on for the setting to become effective 13825
Speed regarded as axis stop for Dual Check Safety
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Minimum unit of data] [Valid data range]
Parameter input Real axis mm/min, inch/min, degree/min (machine unit) Depend on the increment system of the applied axis 0 to 10000 This parameter sets the speed regarded as axis stop in case that an abnormal condition is found in safety speed check or safety machine position check of Dual Check Safety function. When an abnormal condition is found in safety speed check or safety machine position check, a servo alarm occurs. And whether MCC off signal (*MCFVx) is turned off or not is decided by judging if an axis is stopped after the decided time elapse. At that time, this parameter gives the speed to judge axis stop. In case an abnormal condition is detected and an axis is stopped within the given time, an MCC is not turned off. Then the system can be recovered by reset operation without power-off.
- 96 -
Page 105
6.PARAMETERS
B-64004EN/02
NOTE In case of velocity control, set the value calculated by the following formula to this parameter when R(min-1) is the velocity, at which the axis is regarded as stopped. Setting value = R * PLS * Minimum data unit (Machine unit) * N / CMR PLS: Pulse per one revolution of motor (Detection unit) CMR: Command multiplier N: In case of diameter specification, N=2. In other case, N=1. Minimum data unit: Refer to “STANDARD PARAMETER SETTING TABLE”. 13826
Safety limit speed 1 in velocity control for each axis
13827
Safety limit speed 2 in velocity control for each axis
13828
Safety limit speed 3 in velocity control for each axis
13829
Safety limit speed 4 in velocity control for each axis
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]
Parameter input 2-word axis min-1 0 to maximum motor speed This parameter sets the safety speed 1 to 4 for each axis in velocity control mode in Dual Check Safety function.
13831
Safety machine position 1 for each axis (+ direction)
13832
Safety machine position 1 for each axis (- direction)
13833
Safety machine position 2 for each axis (+ direction)
13834
Safety machine position 2 for each axis (- direction)
13835
Safety machine position 3 for each axis (+ direction)
13836
Safety machine position 3 for each axis (- direction)
- 97 -
Page 106
6.PARAMETERS
B-64004EN/02
13837
Safety machine position 4 for each axis (+ direction)
13838
Safety machine position 4 for each axis (- direction)
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Minimum unit of data] [Valid data range]
Parameter input Real axis mm, inch, degree (machine unit) Depend on the increment system of the applied axis 9 digits of minimum unit of data (Refer to standard parameter setting table(A). But in case that CMR≥1, data range becomes 1/CMR of 9 digits of minimum unit of data.) (When the increment system is IS-B and CMR=1, -999999.999 to +999999.999) (When the increment system is IS-B and CMR=2, -499999.999 to +499999.999)
NOTE Whether to specify this parameter by using a diameter value or radius value depends on whether the corresponding axis is based on diameter specification or radius specification. Set a safe machine position for each axis. CNC and Servo always check the machine position on each axis in Dual Check Safety function. If the machine position is out of the safety machine range even on one axis, Monitoring Result signal (RSVx) corresponding to that axis is set to “0”. Moreover if Safety Check request signal (*VLDVx) is set to “0”, an alarm SV0477 or SV0495 is generated for the corresponding axis. Up to 4 safety machine position can be specified. Safety machine position is selected by Safety Speed / Safety Position Selection signal (SVAx/SVBx). As for the detail of Safety Speed / Safety Position Selection signal, refer to the description about Safety Speed / Safety Position Selection signal.
CAUTION The safety machine position checks are made on the basis of the machine position to the detection unit. Accordingly, a calculation error may occur.
- 98 -
Page 107
6.PARAMETERS
B-64004EN/02
WARNING 1 CNC and Servo check the machine position of only each axis whose reference position is established, and not check it of each axis whose reference position is not established. 2 After safety machine position parameters No.13831 to No.13838 have been set, the power must be turned off then back on for the setting to become effective. 13840
Address to which safety position switch 1 to 16 are assigned
13841
Address to which safety position switch 17 to 32 are assigned
13842
Address to which safety position switch 33 to 48 are assigned
13843
Address to which safety position switch 49 to 64 are assigned
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input Byte 0 to 1, 10 to 11, 20 to 21, ... , 90 to 91 According to this parameter, the address to output 64 points of position switch signals can be assigned for each 16 points. The assigning addresses are F*755 to F*756 (PMC) / F(007+m) to F(008+m) (DCS PMC) and F*757 to F*758 (PMC) / F(009+m) to F(010+m) (DCS PMC) in each path. (*: 0 to 9 [path]) The units of this parameter value specifies which address the signal of each path should be output to, “F*755 to F*756” (PMC) / “F(007+m) to F(008+m)” (DCS PMC) or “F*757 to F*758” (PMC) / “F(009+m) to F(010+m)” (DCS PMC). Setting value 0
Assigned address F*755 to F*756(PMC), F(007+m) to F(008+m) (DCS PMC) F*757 to F*758(PMC), F(009+m) to F(010+m) (DCS PMC)
1
The tens of this parameter value specify which path the signal should be output to. Setting value 0 1
Output path Path 1 Path 2 ...
9
- 99 -
Path 10
Page 108
6.PARAMETERS
B-64004EN/02
[Example] Parameter No. 13870
Setting value 00
13871
01
13872
50
13873
71
Output address of position switch signal F755-F756 (1st to 16th position switch)(PMC) F008-F008 (1st to 16th position switch)(DCS PMC) F757-F758 (17th to 32nd position switch) (PMC) F009-F010 (17th to 32nd position switch)(DCS PMC) F5755-F5756 (33rd to 48th position switch) (PMC) F107-F108 (33rd to 48th position switch)(DCS PMC) F7757-F7758 (49th to 64th position switch) (PMC) F109-F110 (49tht to 64th position switch)(DCS PMC)
NOTE 1 If all setting values are “0”, the output address is regarded as follows. Position switch 1 to 16: F755-F756(PMC) / F007-F008(DCS PMC) Position switch 17 to 32: F757-F758(PMC) / F009-F010(DCS PMC) Position switch 33 to 48: F1755-F1756(PMC) / F027-F028(DCS PMC) Position switch 49 to 64: F1757-F1758(PMC) / F029-F030(DCS PMC) 2 Do not assign two or more position switch to the same address. 13880
Axis corresponding to the 1st safe position switch
13881
Axis corresponding to the 2nd safe position switch
… 13910
Axis corresponding to the 31st safe position switch
13911
Axis corresponding to the 32nd safe position switch
10501
Axis corresponding to the 33rd safe position switch
10502
Axis corresponding to the 34th safe position switch
… 10531
Axis corresponding to the 63rd safe position switch
10532
Axis corresponding to the 64th safe position switch
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input Byte 0 to Number of controlled axes - 100 -
Page 109
6.PARAMETERS
B-64004EN/02
These parameters specify the control-axes numbers corresponding to the 1st thorough 64th safe position switch functions. A corresponding position switch signal is output to “I/O Link#1 or #2” and “I/O Link#3, #4 or Profibus-DP” when the machine coordinate value of a corresponding axis is within the range that is set using a parameter.
WARNING 1 Set 0 for those position switch numbers that are not to be used. (The safe position switch signal of that number is not output.) 2 The safe position switch signal for the axis whose parameter No.1904#6 is 1 (Dual Check Safety is disabled) is not output. 3 After safety position switch parameters No.13880 to No.13911, No.10501 to No.10532 have been set, the power must be turned off then back on for the setting to become effective 13920
Maximum operation range of the 1st safe position switch
13921
Maximum operation range of the 2nd safe position switch
: 13950
Maximum operation range of the 31st safe position switch
13951
Maximum operation range of the 32nd safe position switch
10533
Maximum operation range of the 33rd safe position switch
10534
Maximum operation range of the 34th safe position switch
: 10563
Maximum operation range of the 63rd safe position switch
10564
Maximum operation range of the 64th safe position switch
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Minimum unit of data] [Valid data range]
Parameter input Real mm, inch, degree (machine unit) Depend on the increment system of the reference axis 9 digits of minimum unit of data (Refer to standard parameter setting table(A). But in case that CMR≥1, data range becomes 1/CMR of 9 digits of minimum unit of data.) (When the increment system is IS-B and CMR=1, -999999.999 to +999999.999) (When the increment system is IS-B and CMR=2, -499999.999 to +499999.999) - 101 -
Page 110
6.PARAMETERS
B-64004EN/02
NOTE Whether to specify this parameter by using a diameter value or radius value depends on whether the corresponding axis is based on diameter specification or radius specification. These parameters set the maximum operation range of the 1st through 64th safe position switches.
CAUTION 1 When the machine position is on the boundary of the specified ranges (machine position = parameter setting value), it is considered within the specified ranges. 2 When the setting of operation range is “maximum operation range < minimum operation range”, the safe position switch is not output. 3 If parameter No.13920 to No.13951, No.13533 to No.13564 are changed, please turn the power of the machine off once. 13960
Minimum operation range of the 1st safe position switch
13961
Minimum operation range of the 2nd safe position switch
: 13990
Minimum operation range of the 31st safe position switch
13991
Minimum operation range of the 32nd safe position switch
10565
Minimum operation range of the 33rd safe position switch
10566
Minimum operation range of the 34th safe position switch
: 10595
Minimum operation range of the 63rd safe position switch
10596
Minimum operation range of the 64th safe position switch
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Minimum unit of data]
Parameter input Real mm, inch, degree (machine unit) Depend on the increment system of the reference axis
- 102 -