Page 91

6.PARAMETERS

B-64004EN/02

1840

Position deviation limit for each axis in servo-off state during safety check

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

1841

Parameter input 2-word axis Detection unit 0 to 99999999 Set the positioning deviation limit in servo-off state for each axis for Dual Check Safety function. If the positioning deviation exceeds the positioning deviation limit during servo-off, a servo alarm (SV1069,SV1070) is generated, and operation is stopped immediately (as in emergency stop). In Dual Check Safety function, position deviation is always checked by CNC and Servo. In case that Safety Check is carried out (Safety Monitoring Request “*VLDVx” =0), servo alarm (SV1069,SV1070) is generated when each CPU finds out that the deviation exceeds position deviation limit in servo-off state. Position deviation limit of each axis in moving state during other than Dual Check Safety monitoring (for Dual Check Safety Function)

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

Parameter input 2 word axis Detection unit 0 to 99999999 Set the positioning deviation limit in moving state for each axis for Dual Check Safety function, in case that Safety Check is not carried out (Safety Monitoring Request “*VLDVx”=1). In case that Safety Check is not carried out (Safety Monitoring Request “*VLDVx” =1), servo alarm (SV0475,SV1071) is generated and operation is stopped immediately (as in emergency stop), when each CPU finds out that the deviation exceeds position deviation limit in moving state. If the value of this parameter is “0”, the parameter No.1828 is used for the value of deviation limit in moving state. In case that Safety Check is carried out (Safety Monitoring Request “*VLDVx” =0), the parameter No.1838 is used for the value of deviation limit in moving state.

- 83 -

Page 92

6.PARAMETERS

B-64004EN/02

1842

Position deviation limit of each axis in stopped state during other than Dual Check Safety monitoring (for Dual Check Safety Function)

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

Parameter input 2 word axis Detection unit 0 to 99999999 Set the positioning deviation limit in stopped state for each axis for Dual Check Safety function, in case that Safety Check is not carried out (Safety Monitoring Request “*VLDVx”=1). In case that Safety Check is not carried out (Safety Monitoring Request “*VLDVx” =1), servo alarm (SV0474,SV1072) is generated and operation is stopped immediately (as in emergency stop), when each CPU finds out that the deviation exceeds position deviation limit in stopped state. If the value of this parameter is “0”, the parameter No.1829 is used for the value of deviation limit in stopped state. In case that Safety Check is carried out (Safety Monitoring Request “*VLDVx” =0), the parameter No.1839 is used for the value of deviation limit in stopped state. #7

1902

[Input type] [Data type]

#6

#5

#4

#3

#2

#1

#0

DCE

Parameter input Bit

NOTE When this parameter is set, the power must be turned off before operation is continued. #6

DCE

Dual Check Safety function is 0: inactive. 1: active. This parameter invalidates Dual Check Safety function temporarily. In the system with Dual Check Safety function, this parameter is used when the system set up without wiring and ladder related with Dual Check Safety in order to set up other function.

- 84 -

Page 93

6.PARAMETERS

B-64004EN/02

NOTE When Dual Check Safety function is used, this parameter must be set to “1”. If Dual Check Safety function is ordered and this parameter is “0”, an alarm (DS0022) is displayed at power-on. This alarm can be reset by pushing “CAN” and “RESET” key on MDI at the same time. #7 1904

[Input type] [Data type]

#6

#5

#4

#3

#2

#1

#0

DCN

Parameter input Bit axis

NOTE When this parameter is set, the power must be turned off before operation is continued. #6

DCN

The checks of the target axis by Dual Check Safety function are: 0: carried out. 1: not carried out.

NOTE 1 It is not possible to inhibit each check of Dual Check Safety Function of all axes by the parameter DCN. 2 Set the DCN bit to 1 for the slave axis under tandem control or for the tool axis of a simple electronic gear box or electronic gear box 2-pair. 3 The checks by the dual check safety function are not carried out on an axis for which the DCN bit is set to 1. Set the DCN bit to 0 for normal axes. 1945

Safety input signal check timer

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

Parameter input Word machine group msec 0 to 1000 Input/output signals related to Dual Check Safety function (safety double input/output signals) are transmitted through two paths, “I/O Link #1 or #2” and “I/O Link#3, #4 or Profibus-DP”. CNC CPU and PMC CPU exchange the input/output signals with each other at all time to check each other. If a mismatch between double input/output signals through two paths lasts greater than the time set in this - 85 -

Page 94

6.PARAMETERS

B-64004EN/02 parameter, alarm PW0010, PW0011, PW0012 or PW0013 is generated. If a value of less than 16 is specified, it is assumed that 16 ms is specified. If a value of more than 1000 is specified, it is assumed that 1000 ms is specified.

NOTE The same value is applied to each path that belongs to a machine group. 1946

MCC off Test timer

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

Parameter input Word machine group msec 0 to 32767 When MCC off Test mode is selected with Dual Check Safety function, CNC CPU carries out MCC off Test by the safety output signal (*MCF). If MCC off Test is not completed within the time set in this parameter, a servo alarm SV0488 is generated. If a value of less than 0 is specified, it is assumed that 10000 ms is specified.

NOTE The same value is applied to each path that belongs to a machine group. 1948

MCC off timer 2

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

Parameter input Word machine group msec 0 to 32767 CNC CPU and PMC CPU set MCC Off signal (*MCFVx) to 0, when an axis is not stopped within the time set by this parameter after Safe Speed Monitoring or Safe Machine Position Monitoring function of Dual Check Safety function detects abnormal condition.

- 86 -

Page 95

6.PARAMETERS

B-64004EN/02

NOTE The same value is applied for each path that belongs to a machine group. 1950

Brake signal timer

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

Parameter input Word machine group msec 0 to 32767 Set a time period from when CNC CPU and Servo CPU in Dual Check Safety function detects that the servo amplifier is ready (MCC on state) until Safety Brake signal (*BRKx) goes 1 (brake release enabled).

NOTE The same value is applied for each path that belongs to a machine group. 3021

Address to which an axis signal is assigned

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]

Parameter input Byte axis 0 to 7, 10 to 17, 20 to 27, ... , 90 to 97 For each axis of the CNC, set a PMC interface address. Set a value according to the tables below. Setting value 0 1 9 Setting value 0 1

Value of parameter No. 3021 (tens digit) Input signal address Output signal address G0000 to G0999 F0000 to F0999 G1000 to G1999 F1000 to F1999 ・・・ G9000 to G9999 F9000 to F9999 Value of parameter No. 3021 (ones digit) Input signal address Output signal address #0 #1 ・・・ #7

7

- 87 -

#0 #1 #7

Page 96

6.PARAMETERS

B-64004EN/02

[Example of setting] Axis number 1

No.3021

2

1

3

2

4

10

5

11

0

Signal allocation +J1<G0100.0>, -J1<G0102.0>, ZP1<F0090.0>, ... +J2<G0100.1>, -J2<G0102.1>, ZP2<F0090.1>, ... +J3<G0100.2>, -J3<G0102.2>, ZP3<F0090.2>, ... +J4<G1100.0>, -J4<G1102.0>, ZP4<F1090.0>, ... +J5<G1100.1>, -J5<G1102.1>, ZP5<F1090.1>, ...

If eight or less axes are used per path, the following signal allocation results when 0 is set for all axes: Axis 1 of path 1 = Setting equivalent to 0 Axis 2 of path 1 = Setting equivalent to 1 : Axis 1 of path 2 = Setting equivalent to 10 :

NOTE Set this parameter when more than eight axes are used per path. The valid data range varies, depending on the NC system type. 3022

Address to which a spindle signal is assigned

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]

Parameter input Byte spindle 0to3,10to13,20to23, ... ,90to93 For each axis of the CNC, set a PMC interface address. Set a value according to the tables below. Value of parameter No. 3022 (tens digit) Input signal address Output signal address G0000 to G0999 F0000 to F0999 G1000 to G1999 F1000 to F1999 ・・・ 9 G9000 to G9999 F9000 to F9999 Value of parameter No. 3022 (ones digit) Setting value Input signal address Output signal address 0 Bit position A Bit position A 1 Bit position B Bit position B 2 Bit position C Bit position C 3 Bit position D Bit position D Setting value 0 1

- 88 -

Page 97

6.PARAMETERS

B-64004EN/02

(The bit positions A, B, C and D vary, depending on the type of signal.) [Example of setting] Spindle number 1

No.3022 0

2

1

3

10

4

11

Signal allocation TLMLA<G0070.0>, TLMHA<G0070.1>, ALMA<F0045.0>, ... TLMLB<G0074.0>, TLMHB<G0074.1>, ALMB<F0049.0>, ... TLMLA<G1070.0>, TLMHA<G1070.1>, ALMA<F1045.0>, ... TLMLB<G1074.0>, TLMHB<G1074.1>, ALMB<F1049.0>, ...

If four or less axes are used per path, the following signal allocation results when 0 is set for all axes: Axis 1 of path 1 = Setting equivalent to 0 Axis 2 of path 1 = Setting equivalent to 1 : Axis 1 of path 2 = Setting equivalent to 10

NOTE Set this parameter when more than four axes are used per path. The valid data range varies, depending on the system software. 3225

Code for safety parameters

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]

Parameter input 2-word 0 to 99999999 Set a code (password) for protecting against modifications to parameters related to Dual Check Safety function (safety parameters). When a code for safety parameters is set other than the value “0”, the parameters are locked. In this state, the setting (code) is not displayed but is blank, and safety parameter input is disabled. If an attempt is made to input data in a locked safety parameter, the result indicated in the table below is produced, depending on the method of input. No attempt is successful. Input method

Result MDI input Warning “WRITE PROTECT” Input via reader/puncher interface No alarm is generated. But parameter input is disabled. Input through window function Completion code 7 (WRITE PROTECT)

If the value other than “0” is set to this parameter, the safety parameter cannot be modified. The safety parameters can be set when the safety - 89 -

Page 98

6.PARAMETERS

B-64004EN/02 parameters are not locked, that is, when the code for safety parameters is 0, or when the code for safety parameters is the same as the key for safety parameters (No. 3226). The following safety parameters are protected by a code for safety parameters: No.980, No.981, No.982, No.1023, No.1240, No.1838, No.1839, No.1840, No.1841, No.1842, No.1902, No1904, No.1945, No.1946, No.1948, No.1950, No.3021, No.3022, No.3225, No.3717, No.3797, No.4372, No.4438, No.4440, No.4442, No.4448, No.10500, No.10501-No.10596, No.11950-No.11957, No.11960-N0.11967, No.11970-No.11977, No.11980-No-11987, No.13811, No.13821-No.13829, No.13831~No.13838, No.13840-No.13843, No.13880-No.13911, No.13920-No.13951, No.13960-No.13991

NOTE Once parameters are locked, the lock must be released or memory must be cleared before the safety parameters can be modified. Moreover, the code for the safety parameters cannot be modified in locked condition. Be careful when setting a code for safety parameters. 3226

Key for safety parameters

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]

Parameter input 2-word 0 to 99999999 When the same value as the code for safety parameters No.3225 is set in this parameter, the key is opened to enable modifications to the safety parameters. The value set in this parameter is not displayed. When the value other than 0 is set to the code for safety parameters No.3225 and the value is different from this parameter, the key is locked and the safety parameters can not be modified. When the power is turned off, the value set in this parameter is cleared to 0. Then the power-off results in the locked state.

- 90 -

Page 99

6.PARAMETERS

B-64004EN/02

3717

Motor number to each spindle

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]

Parameter input Byte spindle 0 to Maximum number of controlled axes Set a spindle amplifier number to be assigned to each spindle. 0: No spindle amplifier is connected. 1: Spindle motor connected to amplifier number 1 is used. 2: Spindle motor connected to amplifier number 2 is used. to n: Spindle motor connected to amplifier number n is used. #7

#6

#5

3797

[Input type] [Data type]

#4

#3

#2

#1

#0 DCN

Parameter input Bit spindle

NOTE When this parameter is set, the power must be turned off before operation is continued. #0

DCN

Each safety check of Dual Check Safety function for the specified spindle is 0: carried out. 1: not carried out. Set “1” to this bit for the spindle that is not required to apply Dual Check Safety.

- 91 -

Page 100

6.PARAMETERS

B-64004EN/02

4372

Safe speed 1 for each spindle

4438

Safe speed 2 for each spindle

4440

Safe speed 3 for each spindle

4442

Safe speed 4 for each spindle

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

Parameter input Word spindle min-1 0 to 32767 Set a safe speed for each spindle in terms of motor speed. In case Dual Check Safety function is activated, CNC and Spindle always check the speed of each spindle motor. When it is detected that revolution speed of spindle exceeds safety speed limit, Monitoring Result signal (RSPs) is set to “0”. Moreover if the safety check is carried out (Safety Check Request signal *VLDPs =”0”), an alarm SP0757(CNC side) or SP9069(Spindle side) occurs. Safety Speed can be set up to 4 data. Which speed should be selected is decided by Safety Speed Selection signal (SPAs/SPBs). Please refer more detail to the description about Safety Speed/Safety Position Selection signal.

CAUTION After Safety Speed parameters No.4372, No.4438, No.4440 or No.4442 has been modified, the power must be turned off then back on for the setting to become effective. 4448

Stop check level

NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]

Parameter input Word spindle min-1 0 to 32767 When a spindle motor is in free-run state because of excess of safety speed, a motor is regarded as stop state if the speed of a spindle motor becomes lower than the value set by this parameter. In this condition, an alarm can be reset. The setting value must be lower than the parameter “Safe Speed for each spindle”. - 92 -