Page 81
5.I/O SIGNALS
B-64004EN/02
NOTE When “Composite control” or “Path speed control of Multi path control” is specified, it is possible to give a command to control a servo axis or a spindle in another path. But in this case, the correspondence between a path and a belonging servo axis or spindle is not changed. An alarm related to a servo axis or a spindle occurs in the path that the axis and the spindle originally belong to, and MCC shut off signal correspond to the axis or spindle is output also in original path. Then, as the path that gives a command and the path that an axis and a spindle belongs to should be regarded as the same group, it is necessary to wire MCC off signal (*MCFVx, *MCFPs) to shut off the MCC of both path at the same time when “Composite control” or “Path speed control of Multi path control” is specified.
- 73 -
Page 82
6.PARAMETERS
6
B-64004EN/02
PARAMETERS
- 74 -
Page 83
6.PARAMETERS
B-64004EN/02
6.1
OVERVIEW The parameters related to the dual check safety function (safety parameters) are protected by a code (No. 3225) for the safety parameters. The value of a safety parameter cannot be modified unless the same value as the code for the safety parameters is set as the key (No. 3226) for the safety parameters. The safety parameters are stored in two locations on the CNC. The CNC, PMC, servo and spindle software check the matching of the parameters stored at the two locations. If a mismatch is found, an alarm is issued. If the setting of a safety parameter is modified, the power must be turned off then back on. The new setting of the parameter becomes effective after the power is turned back on.
- 75 -
Page 84
6.PARAMETERS
6.2
B-64004EN/02
DATA TYPE Parameters are classified by data type as follows: Data type
Valid data range
Remarks
Bit Bit machine group Bit path
0 or 1
Bit axis Bit spindle Byte Byte machine group Byte path Byte axis Byte spindle Word Word machine group Word path Word axis Word spindle 2-word 2-word machine group 2-word path 2-word axis 2-word spindle Real Real machine group Real path Real axis Real spindle
-128 to 127 0 to 225
Some parameters handle these types of data as unsigned data.
-32768 to 32767 0 to 65535
Some parameters handle these types of data as unsigned data.
0 to ±999999999
Some parameters handle these types of data as unsigned data.
See the Standard Parameter Setting Tables.
NOTE 1 Each of the parameters of the bit, bit machine group, bit path, bit axis, and bit spindle types consists of 8 bits for one data number (parameters with eight different meanings). 2 The machine group type allows data to be set separately for each machine group. 3 The path type allows data to be set separately for each path. 4 The axis type allows data to be set separately for each control axis. 5 The spindle type allows data to be set separately for each spindle axis. 6 The valid data range for each data type indicates a general range. The range varies according to the parameters. For the valid data range of a specific parameter, see the explanation of the parameter.
- 76 -
Page 85
6.PARAMETERS
B-64004EN/02
6.3
REPRESENTATION OF PARAMETERS
Parameters of the bit type, bit machine group type, bit path type, bit axis type, and bit spindle type #7
#6
#5
0000
Data No.
#4
#3
#2
#1
#0
EIA
NCR
ISP
CTV
TVC
Data (Data #0 to #7 are bit positions.)
Parameters other than the bit-type parameters above 1023
Number of the servo axis for each axis
Data No.
Data
NOTE 1 The parameters, which are described here, are related directly to Dual Check Safety function. As for the other parameters, please refer to the parameter manual (B-63950EN). 2 A parameter usable with only one path control type, namely, the lathe system (T series) or the machining center system (M series), is indicated using two rows as shown below. When a row is blank, the parameter is not usable with the corresponding series. [Example 1] Parameter HTG is a parameter common to the M and T series, but Parameters RTV and ROC are parameters valid only for the T series. #7 1403
RTV
#6
#5
#4
HTG
ROC
#3
#2
#1
#0 T series M series
HTG
[Example 2] The following parameter is provided only for the M series. T series 1411
M series
Cutting feedrate
3 When "to" is inserted between two parameter numbers, there are parameters with successive numbers between the two starting and ending parameter numbers, but those intermediate parameter numbers are omitted for convenience. 4 The lower-case letter "x" or "s" following the name of a bit-type parameter indicates the following: x” : Bit axis type parameters -” -” s” : Bit spindle type parameters
- 77 -
Page 86
6.PARAMETERS
6.4
B-64004EN/02
STANDARD PARAMETER STTING TABLES
Overview This section defines the standard minimum data units and valid data ranges of the CNC parameters of the real type, real machine group type, real path type, real axis type, and real spindle type. The data type and unit of data of each parameter conform to the specifications of each function.
Explanation (A) Length and angle parameters (type 1) Unit of data mm deg.
inch
Increment system
Minimum data unit
IS-A IS-B IS-C IS-D IS-E IS-A IS-B IS-C IS-D IS-E
0.01 0.001 0.0001 0.00001 0.000001 0.001 0.0001 0.00001 0.000001 0.0000001
Valid data range -999999.99 to +999999.99 -999999.999 to +999999.999 -99999.9999 to +99999.9999 -9999.99999 to +9999.99999 -999.999999 to +999.999999 -99999.999 to +99999.999 -99999.9999 to +99999.9999 -9999.99999 to +9999.99999 -999.999999 to +999.999999 -99.9999999 to +99.9999999
(B) Length and angle parameters (type 2) Unit of data mm deg.
inch
Increment system
Minimum data unit
Valid data range
IS-A IS-B IS-C IS-D IS-E IS-A IS-B IS-C IS-D IS-E
0.01 0.001 0.0001 0.00001 0.000001 0.001 0.0001 0.00001 0.000001 0.0000001
0.00 to +999999.99 0.000 to +999999.999 0.0000 to +99999.9999 0.00000 to +9999.99999 0.000000 to +999.999999 0.000 to +99999.999 0.0000 to +99999.9999 0.00000 to +9999.99999 0.000000 to +999.999999 0.0000000 to +99.9999999
- 78 -
Page 87
6.PARAMETERS
B-64004EN/02
(C) Velocity and angular velocity parameters Unit of data
Increment system
Minimum data unit mm/min degree/min
IS-A IS-B IS-C IS-D IS-E
0.01 0.001 0.0001 0.00001 0.000001
0.0 0.0 0.0 0.0 0.0 to +999000.00 to +999000.000 to +99999.9999 to +9999.99999 to +999.999999 inch/min
IS-A IS-B IS-C IS-D IS-E
0.001 0.0001 0.00001 0.000001 0.0000001
0.0 0.0 0.0 0.0 0.0 to +96000.000 to +9600.0000 to +4000.00000 to +400.000000 to +40.0000000
Valid data range
(D)Acceleration and angular acceleration parameters Increment system
Minimum data unit mm/sec deg./sec2
IS-A IS-B IS-C IS-D IS-E
0.01 0.001 0.0001 0.00001 0.000001
0.00 0.000 0.0000 0.00000 0.000000 inch/sec2
IS-A IS-B IS-C IS-D IS-E
0.001 0.0001 0.00001 0.000001 0.0000001
0.000 to +99999.999 0.0000 to +99999.9999 0.00000 to +9999.99999 0.000000 to +999.999999 0.0000000 to +99.9999999
Unit of data
2
Valid data range to +999999.99 to +999999.999 to +99999.9999 to +9999.99999 to +999.999999
Notes (1) Values are rounded up or down to the nearest multiples of the minimum data unit. (2) A valid data range means data input limits, and may differ from values representing actual performance. (3) For information on the ranges of commands to the CNC, refer to Appendix, "List of Command Ranges," in the "USER’S MANUAL" (B-63944EN). (4) The setting value of the parameter related with length and angle depends on whether the attribute of the axis is diameter specification or radius specification. In case safety function, set the parameter according to the attribute of the axis at power on. Even if the attribute is changed after power on, changed value is not used by each safety function. Each safety function refers to the value that is specified at power on. .
- 79 -
Page 88
6.PARAMETERS
6.5
B-64004EN/02
PARAMETERS 0980
Machine group number of each path
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input Byte path 1 to 3 Set the machine group number which each path belongs.
NOTE When 0 is set, each path is assumed to belong to machine group 1. 0981
Absolute path number of each axis
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input Byte axis 1 to 10 Set the path to which each axis belongs.
NOTE When 0 is set each axis is assumed to belong to path 1. 0982
Absolute path number of each spindle
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
Parameter input Byte spindle 1 to 10 Set the path to which each spindle belongs.
NOTE When 0 is set each axis is assumed to belong to path 1.
- 80 -
Page 89
6.PARAMETERS
B-64004EN/02
1023
Servo axis number of each axis
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Valid data range]
1240
Parameter input Byte axis 0 to Number of controlled axis Set the servo axis for each control axis. Usually set to same number as the control axis number. The control axis number is the order number that is used for setting the axis-type parameters or axis-type machine signals With an axis for which Cs contour control/spindle positioning is to be performed, set "-(spindle number)" as the servo axis number. Example) When performing Cs contour control on the fourth control axis by using the first spindle, set -1. Coordinates value of the reference position in the machine coordinate system
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Minimum unit of data] [Valid data range]
Parameter input Real axis mm, inch, degree (machine unit) Depend on the increment system of the applied axis 9 digit of minimum unit of data (Refer to standard parameter setting table(A). But in case that CMR≥1, data range becomes 1/CMR of 9 digits of minimum unit of data.) (When the increment system is IS-B and CMR=1, -999999.999 to +999999.999) (When the increment system is IS-B and CMR=2, -499999.999 to +499999.999)
NOTE Whether to specify this parameter by using a diameter value or radius value depends on whether the corresponding axis is based on diameter specification or radius specification. Set the coordinate values of the reference position in the machine coordinate system.
- 81 -
Page 90
6.PARAMETERS
B-64004EN/02
1838
Position deviation limit for each axis in moving state during safety check
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]
1839
Parameter input 2-word axis Detection unit 0 to 99999999 Position deviation limit for each axis in moving state for safety check of Dual Check Safety function is specified. If position deviation of a moving axis exceeds position deviation limit while Safety Check is carried out (Safety Monitoring Request “*VLDVx” =0), a servo alarm (SV0475, SV1071) is generated and axes are stopped immediately like emergency stop state. In Dual Check Safety function, position deviation is always checked by CNC and Servo. In case that Safety Check is carried out (Safety Monitoring Request “*VLDVx” =0), the servo alarm (SV0475,SV1071) is generated when each CPU finds out that the deviation exceeds position deviation limit in moving state. Position deviation limit for each axis in stopped state during safety check
NOTE When this parameter is set, the power must be turned off before operation is continued. [Input type] [Data type] [Unit of data] [Valid data range]
Parameter input 2-word axis Detection unit 0 to 99999999 Set the positioning deviation limit in stopped state for each axis for Dual Check Safety function. If the positioning deviation exceeds the positioning deviation limit during stopped state while Safety Check is carried out (Safety Monitoring Request “*VLDVx” =0), a servo alarm (SV0474, SV1072) is generated, and operation is stopped immediately (as in emergency stop). In Dual Check Safety function, position deviation is always checked by CNC and Servo. In case that Safety Check is carried out (Safety Monitoring Request “*VLDVx” =0), servo alarm (SV0474,SV1072) is generated when each CPU finds out that the deviation exceeds position deviation limit in stopped state.
- 82 -