The text of a manual · part 8 of 18
FANUC Series 30i/31i/32i-MODEL A Dual Check Safety Operator's Manual, pages 71 to 80
Pages 71 to 80 of 174
The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Fanuc A03B-0807-C159, Fanuc ABU05A, Fanuc ABU10A, Fanuc AIA16G, Fanuc AID16C, Fanuc AID16D, Fanuc AID32F1, Fanuc AIF01A, and 33 more models
Page 71
5.I/O SIGNALS
B-64004EN/02
After that, if the spindle is not decelerated, each CPU turns this signal to “0”. In case of an alarm other than described above and related to data communication or position detector, each CPU turns this signal corresponding to the alarm spindle to “0” immediately. But according to the parameter setting (No.10500#1 = 1), it is possible to turn to “0” this signals of all the spindles belonged to the path that involves the alarm spindle in case of any spindle alarms. MCC Off Test Execution Request signal (output) RQT <PMC:Fn191#2> (for each machine group) [Classification] Output signal (Single signal) [Function] This signal notifies that MCC off Test mode is required and a check should be made to determine whether the safety output signals (MCC Off signal (*MCF)) operate normally. When MCC Off Test Execution Request signal (RQT) is set to 1, set MCC off Test mode and carry out a safety output signal MCC off Test as soon as possible. When MCC Off Test Execution Request signal (RQT) is 1, a machine tool builder must make ladder not to release a guard lock. Once a guard is closed when MCC Off Test Execution Request signal (RQT) is set to “1” while a guard is open by Guard Open Request signal (ORQ), it is necessary not to release a guard lock until MCC off Test request signal (RQT) turns to “0”. When MCC Off Test Execution Request signal (RQT) is 1, the following screen is displayed and the warning “EXECUTE MCC TEST” is displayed.
MCC Off Test Execution Request signal (RQT) is not output via the DCS PMC. Make a ladder program to lock a protective door when MCC Off Test Execution Request signal (RQT) =1.
- 63 -
Page 72
5.I/O SIGNALS
B-64004EN/02
[Output condition]
In the following case, this signal is set to “1”. • MCC off Test is not completed after power-on (when bit 3 of parameter No.10500 is 0). • Twenty-four hours have elapsed since the completion of the last MCC off Test. In the following case, this signal sets to “0”. • MCC off Test is completed.
CAUTION 1 Do not turn Test Mode signal (OPT) to “0” during MCC off Test. 2 In case that there are plural machine groups in a machine, carry out MCC off Test for each machine group independently. 3 If MCC is shared between two or more machine groups, do not carry out MCC off Test for those machine groups at the same time. 4 If MCC is shared between two or more machine groups and MCC off Test is carried out in a machine group, VRDY off alarm in another machine group, which shared MCC, must be ignored by using all axes of each path VRDY off alarm ignore signal IGNVRY <Gn066#0> or each axis VRDY off alarm ignore signal IGNVRY1 to IGNVRY8 <Gn192>. WARNING While the MCC off Test processing is in progress, the MCC Off signal (*MCF) goes high and low to turn on and off the MCC. Carry out the MCC off Test in such a state that the turning on or off of the MCC will not cause a problem. Safety Brake signal (output) *BRKx <PMC:Fn754#0 to #7><DCS PMC:F(006+m)#0 to #7> (for each axis) This signal is used to control mechanical brake of each axis. CNC and SV output Safety Brake signal (*BRKx) to control mechanical brake. When *BRKx is “0”, mechanical brake is active. When *BRKx is “1”, mechanical brake is not active. Note that *BRKx cannot be used with all axes of each path VRDY off alarm ignore signal IGNVRY <Gn066#0> or each axis VRDY off alarm ignore signal IGNVRY1 to IGNVRY8 <Gn192>. [Classification] [Function]
Output signal (Dual signal) When the Dual Check Safety Function is applied, this signal notifies to activate a mechanical brake. When MCC is off, a brake should be activated.
- 64 -
Page 73
5.I/O SIGNALS
B-64004EN/02
[Operation]
[Output condition]
In emergency stop state or alarm state, a mechanical brake is activated by this signal. A machine tool builder must connect this signal to a mechanical brake. In the following case, this signal is “1”. • Releasing brake state In the following case, this signal is “0”. • Activating brake state (a) In case *BRK signal is “0” Emergency Stop state (*ESP signal is “0”) 1 *ESP 0 *BRK
1 0
Servo alarm occurs 1 Alarm 0 *BRK
1 0
Power-on Power *BRK
1 0 1 0
(b) In case BRK signal is “1” When emergency stop is released (*ESP signal is “1”), MCC can be enabled l (*MCF signal is “1”). After that, when MCC is turned on, Safety Brake signal *BRK is turned to “1” after the time specified by the parameter No.1950 is elapsed. *ESP *MCF MCC *BRK
1 0 1 0 1 0 1
Timer for brake signal
0
NOTE Regular maintenance of a brake must be done. - 65 -
Page 74
5.I/O SIGNALS
B-64004EN/02
Safety Position Switch signal (output) SPS1 to SPS32<PMC:Fn755 to Fn758><DCS PMC:F(007+m) to F(010+m)> This signal shows whether the machine position of a servo axis is within the range specified by the parameter or not. [Classification] [Function]
Output signal (Dual signal) This signal notifies that the machine position of the axis specified by the safety parameter (No.13880 to No.13911) is within the range specified by the safety parameter (No.13920 to No.13951, No.13960 to No.13991). In case of single path system, up to 32 points can be used. In case of 2 or more path system, another 32 points in 2 path area can be used. Then up to 64 points can be used at maximum. This signal notifies that the machine position of the axis specified by the safety parameter (No.10501 to No.10532) is within the range specified by the safety parameter (No.10533 to No.10564, No.10565 to No.10596).
NOTE In case of 3 or more path system, safety position switch can be assigned up to 16 points per 1 group to the output signal (F area) and totally up to 4 groups can be used in the CNC system. Two areas per a path are provided to assign. It is possible to assign the signal to an appropriate area. [Output condition]
[Note]
In the following case, this signal is set to “1”. • The machine position of the axis is within the specified range. In the following case, this signal is set to “0”. • The machine position of the axis is out of the specified range. When the axis is just on the boundary of the range (machine position is equal to parameter setting value), it is regarded that the machine position is within the range. If the state of two Safety Position Switch of the signal of DCS PMC side and the signal of PMC side is different more than the specified period, each CPU shuts off MCC by DCS alarm (PW0010,PW0011).
- 66 -
Page 75
5.I/O SIGNALS
B-64004EN/02
NOTE Position switch signal is activated when the reference point correspond to the axis is established after power-on. The state of position switch is kept to “0” till then. Once activating, position is always checked and state of signal is changed according to the result of checking. Even if the reference point is lost, the state of signal is changed according to the coordinate kept in both CNC and servo CPU. So if the special procedure is required when the reference point is lost, design the ladder program by combining with Position Information Effect signal (POSEx). Safety Speed/Safety Position Selection signal A SVAx <PMC:Gn752#0 to #7> <DCS PMC:G(004+m)#0 to #7> (for each axis) SPAs <PMC:Gn754#0 to #3> <DCS PMC:G(006+m)#0 to #3> (for each spindle) Safety speed/safety position selection signal B SVBx <PMC:Gn753#0 to #7> <DCS PMC:G(005+m)#0 to #7> (for each axis) SPBs <PMC:Gn754#4 to #7> <DCS PMC:G(006+m)#4 to #7> (for each spindle) [Classification] Input signal (Dual signal) [Function] When the Dual Check Safety Function is activated, it is possible to select safety limit speed and safety machine position of each axis. This signal is prepared for each axis and each spindle. The final number in the signal name shows the number of the controlled axis and spindle. SVAx, SVBx x 1: Select safety speed/safety machine position of the 1st axis 2: Select safety speed/safety machine position of the 2nd axis 3: Select safety speed/safety machine position of the 3rd axis : : : : SPAy, SPBy y 1: Select safety speed of the 1st spindle 2: Select safety speed of the 2nd spindle : : : :
- 67 -
Page 76
5.I/O SIGNALS
B-64004EN/02
[Operation]
According to the combination of Safety Speed/Safety Machine Position Selection signal, safety speed and safety machine position are selected as the following table.
Safety Speed/ Safety Machine Position Selection signal SVAn SVBn SPAn SPBn 0
0
1
0
0
1
1
1
Safety limit speed Parameter for servo axis
Parameter for spindle
Safety limit speed 1 No.13821 No.4372 Safety limit speed 2 No.13822 No.4438 Safety limit speed 3 No.13823 No.4440 Safety limit speed 4 No.13824 No.4442
Safety machine position + direction parameter
- direction parameter
Safety machine position 1 No.13831 No.13832 Safety machine position 2 No.13833 No.13834 Safety machine position 3 No.13835 No.13836 Safety machine position 4 No.13837 No.13838
CAUTION Safety Speed/Safety Machine Position Selection signal is a safety signal. This signal is input through both PMC and DCS PMC. Both CNC and PMC check doubly inconsistency of this signal. Position Information Effect signal POSEx <PMC: Fn766#0 to #7><DCS PMC: F(018+m)#0 to #7> (for each axis) This signal is output when Dual Check Safety function is activated and the reference point is established. When the reference point is not established, the machine system is in danger state because Safety Machine Position Monitoring and Safety Position Error Monitoring are not active. If this signal is “0”, Machine Tool Builder has to control not to open the protective door. [Classification] [Function] [Operation]
Output signal (This signal output to both PMC but is not monitored doubly) This signal informs whether the reference point is established or not. 0: The reference point is not established. 1: The reference point is established. Each CPU informs whether the reference point is established or not. In the following case, this signal is turned to “1”. • After the reference point is established. • When the follow up operation of absolute pulse coder is finished after power-on In the following case, this signal is turned to “0”. • When the reference point is lost
NOTE In case that the reference point is re-established, this signal is turned to “0” till the reference point is re-established from the dog-signal is turned off.
- 68 -
Page 77
5.I/O SIGNALS
B-64004EN/02
Programmable Safety I/O signals [Classification] Input/Output signal (Dual signal) [Function] The 8 bytes (64 bit) programmable safe I/Os can be freely defined as the different address from the above basic safe signals. Each byte of 8 byte programmable safe I/Os can be assigned on either address of X/Y or R or D by parameter. Each byte of the programmable safe I/O between the PMC and DCS PMC is cross-checked by the CNC and PMC.
CNC CPU(DCS PMC)
PMC CPU(PMC)
Input Signal 1
Input Signal 2
:
Input Signal 1
CNC and PMC
Input Signal 2
: monitor each
Input Signal 8 signal. Input Signal 8
Output Signal 1
Output Signal 1
Output Signal 2
Output Signal 2
:
:
Output Signal 8
Output Signal 8
I/O Link or PROFIBUS-DP
I/O Link
- 69 -
Page 78
5.I/O SIGNALS
B-64004EN/02
[Operation]
The combinations of cross-checking these signals are defined by using Safety parameters as follows. Signal type input output
Combination No. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
- 70 -
CNC (DCS PMC) No. 11950 No. 11951 No. 11952 No.11953 No.11954 No.11955 No.11956 No.11957 No.11960 No.11961 No.11962 No.11963 No.11964 No.11965 No.11966 No.11967
PMC(PMC) No. 11970 No. 11971 No. 11972 No.11973 No.11974 No.11975 No.11976 No.11977 No.11980 No.11981 No.11982 No.11983 No.11984 No.11985 No.11986 No.11987
Page 79
5.I/O SIGNALS
B-64004EN/02
5.4
GENERAL PURPOSE I/O SIGNAL
How to turn off general purpose signal When it is confirmed that *DCALM, *MCF, *MCFVx and *MCFPs is “0”, turn general purpose I/O signal off if necessary. (a) In case MCC off Test is carried out, When RQT=1 and OPT=1, ignore *MCF=0. (b) In case of emergency stop (*ESP=0) When *ESP=0, ignore *MCF=0.
- 71 -
Page 80
5.I/O SIGNALS
5.5
B-64004EN/02
NOTE ON MULTI PATH CONTROL This section describes cautions about safe-related I/O signals that should be taken in multi-path control.
5.5.1
Machine Group And Multi Path Control CNC can treat servo axes and spindles by dividing into two classes of groups, machine group and path In case that a machine has plural machine parts that are controlled independently, machine group is provided to control a part of machine in such machine. Emergency stop is prepared for each machine group. The signals for MCC off Test and protective door open/close sequence are provided for each machine group. In case that a work piece is machined by plural cutters and plural programs at the same time, multi path control is applied. An alarm is checked by each path. If servo alarm occurs in a path, MCC of all axes in the path is shut off. In case of the alarm by safety check function, MCC of all axes in the path are shut off. Then the safety area should be set for each path basically. When plural safety areas are defined in a path, MCC may be shut off by an alarm that occurs in another safety area. When the safety area is composed by the axes that change assignment to a path, MCC of other axes are not always shut off. So wire the MCC of all paths, which include the axes changed assignment to the path, to shut off at the same time. The safety signals that are cross-checked are provided both on PMC and DCS PMC for each path. The state must be controlled to be equal.
- 72 -