Page 61

5.I/O SIGNALS

B-64004EN/02

5.3

SIGNALS

Emergency Stop signal (input) *ESP <PMC:X008#4, #0, #1><DCS PMC:X008#4, #0, #1> (for each machine group) *ESP <PMC: Gn008#4> <DCS PMC: G(019+m)#4> (for each path) This is Emergency Stop signal. The Emergency Stop signal must be connected to the Emergency Stop input of the amplifier. [Classification] [Function] [Operation]

Input signal (Dual signal) Stops machine movement immediately in an emergency. 0: Emergency stop state 1: Normal state When Emergency Stop signal (*ESP) is set to 0, the CNC is reset, and the system enters emergency stop state. A machine tool builder must output a signal to shut off directly the MCC when “MCC Off signal” (*MCF) is set to “0”. In emergency stop state, a machine tool builder must check “MCC Contact State signal” (*SMC). If *SMC signal is “0” (MCC is on), a machine tool builder must not release the guard lock signal of protective door. In general, Emergency Stop signal (*ESP) is specified by the pushbutton switch B contact. When an emergency stop occurs, the servo ready signal SA is set to 0. If the input of the Emergency Stop signal is detected, the CNC automatically specifies a command to zero the speed of a servo motor and reduces the speed to zero (controlled stop). (See below note) After the servo motor slows down and stops, the power is turned off, and the servo motor is brought into the dynamic brake stop state. The spindle motor is slowed down by the PMC command (see below note) and the power is shut off.

- 53 -

Page 62

5.I/O SIGNALS

B-64004EN/02

CAUTION 1 The Emergency Stop signal for DCS PMC is assigned to each machine group, like the signal for PMC. <X008#4> for 1st machine group <X008#0> for 2nd machine group <X008#1> for 3rd machine group 2 The related parameter must be set in order to perform the controlled stop of a servo motor. If the parameter is not set, a servo motor is stopped by dynamic brake control just after an emergency stop is detected. 3 A spindle motor is slowed down by the command (PMC ladder program). If the PMC does not command to slow down, the spindle motor continues rotating at the speed prior to power-down and runs by inertia (and eventually stopping in the end). When safety function is active (protective door is open) and abnormal speed is given due to the trouble of PMC, the spindle is brought into safe stop state. 4 The Emergency Stop signals for every machine group, <X008#4> <X008#0> <X008#1>, are checked doubly in PMC and DCS PMC. WARNING A machine tool builder must make the ladder to control to open and shut protective door in emergency stop state. For instance, a machine tool builder must make the ladder program for procedure to inhibit to open the protective door in emergency stop state. IMPORTANT 1 Emergency stop button must fulfill the Standard IEC60947-5-1.This is mandatory. 2 As MCC Off signal (*MCF) is effective for each machine group, MCC is controlled per a machine group. Then, although the Emergency Stop signal by G signal is effective for each path, design to turn on Emergency Stop by G signal of all paths in a machine group at the same time.

- 54 -

Page 63

5.I/O SIGNALS

B-64004EN/02

Example of protective door open/shut sequence The following figure shows the sequence in case of emergency stop. EMG_P

*ESP

*SMC RSVx RSPs Actual door lock releasing signal

*SGOPN (Safety related I/O)

Actual door open/close signal

Door closed

Door closed

Door opened

(1)

(2)

(3)

(4)

(5)

t

A machine tool builder must design the ladder program as follows: (1) In case Emergency Stop signal (*ESP) is input, the guard lock signal is turned off after confirming safety machine position, safety speed and safety position error by the Monitoring Result signals RSVx/RSPs. (2) In this example, it is assumed that a protective door with an electronic door lock is applied. When a door is opened, door lock releasing signal must be turned off. At the same time, Guard State signal (*SGOPN: machine side signal) is changed to show guard-releasing state. (3) This is door open state (4) Protective door is shut and locked. Then Emergency Stop signal (*ESP) is released. Pay attention the time “t”. (5) After Emergency Stop signal is released, CNC turns MCC Off signal (*MCF) to “1”. Test Mode signal (input) OPT <PMC:Gn191#2> (for each machine group) When this signal is input, MCC off Test is carried out. MCC off Test checks whether the contact of the MCC is abnormally closed or not. MCC Off Test Execution Request signal (RQT) notifies that MCC off Test should be executed. Input this signal while servo ready signal (SA) is set to “1”. When MCC off Test is carried out by manual operation, input this signal after preparing to carry out MCC off Test by PMC.

- 55 -

Page 64

5.I/O SIGNALS

B-64004EN/02

[Classification] [Function]

[Operation]

Input signal (Single signal) This signal notifies CNC to enter MCC off Test mode. 0: not enter MCC off Test mode 1: enter MCC off Test mode Test Mode signal (OPT) through I/O Link#3, 4, Profibus-DP is not provided. When this signal (OPT) is set to “1”, CNC turns on/off MCC in various combinations with MCC Off signals *MCF(PMC)/*MCF(DCS PMC). And CNC checks whether MCC Contact State signals *SMC(PMC)/ *SMC(DCS PMC) are input in proper combination corresponding to the combination with MCC Off signals. However MCC off Test should not be carried out in case of emergency stop state, servo alarm state or spindle alarm state. Avoid VRDY OFF alarm by MCC off Test by using all axes of each path VRDY off alarm ignore signal IGNVRY <Gn066#0> or each axis VRDY off alarm ignore signal IGNVRY1 to IGNVRY8 <Gn192>. If MCC off Test is not completed within the time specified by the parameter No.1946, a servo alarm SV0488 occurs.

CAUTION 1 While MCC off Test is being carried out, do not turn Test Mode signal (OPT) to “0”. 2 It is not permitted to carry out MCC off Test for plural machine groups simultaneously. Carry out MCC off Test for only one machine group independently. 3 If MCC is shared between two or more machine groups and MCC off Test is carried out in a machine group, VRDY off alarm in another machine group, which shared MCC, must be ignored by using all axes of each path VRDY off alarm ignore signal IGNVRY <Gn066#0> or each axis VRDY off alarm ignore signal IGNVRY1 to IGNVRY8 <Gn192>. 4 The MCC shall have forced guided contacts , and must fulfill the standard IEC60204 and IEC 60255. This is mandatory. WARNING While the MCC off Test processing is in progress, the MCC Off signal (*MCF) goes high and low to turn on and off the MCC. Carry out the MCC off Test in such a state that the turning on or off of the MCC will not cause a problem.

- 56 -

Page 65

5.I/O SIGNALS

B-64004EN/02

NOTE If MCC off Test is executed when MCC is forced to shut off in emergency stop state, servo alarm state or spindle alarm state, the test cannot be executed normally. MCC off Test should be executed only when the test can be executed normally. Test No.

1

2

3

4

5

*MCF (DCS PMC) *MCF (PMC) *SMC (DCS PMC) *SMC (PMC) Timer limit Timer

Test start

Test completion

Example 1) Timing chart 1 of MCC off test (normal state)

Test No.

1

2

3

4

*MCF (DCS PMC) *MCF (PMC) *SMC (DCS PMC) *SMC (PMC) Timer limit Alarm !!

Timer

Test start Example 2) Timing chart 2 of MCC off test (abnormal state)

- 57 -

Page 66

5.I/O SIGNALS

B-64004EN/02

Guard Open Request signal (input) ORQ <PMC: Gn191#3>(for each machine group) This signal is input when an operator intends to release the guard lock and open the protective door. [Classification] Input signal (Single signal) [Function] In order to open the protective door, this signal requests CNC to unlock the guard lock with the Dual Check Safety Function. Guard Open Request signal (ORQ) is not input via the DCS PMC. 0: not request to open guard lock. 1: request to open guard lock [Operation] When CNC detects that the Guard Open Request signal (ORQ) is 1, CNC returns Guard Open Inhibit signal (*OPIHB). A machine tool builder must design the PMC ladder program so that the guard lock is released after judging the result of safety machine position check, safety speed check, safety position error check to be safe or other safety condition such as Dual Check alarm status signal to be safe. This signal is not a safety signal that is checked doubly. But this is an important signal to make up the safety system. Then a machine tool builder must design the proper ladder program to deal with this signal.

IMPORTANT The mistake of the ladder program cannot be checked. So be sure to perform the confirmation of the safety function. (refer to the chapter 7) Guard State signal (Machine side input signal) *SGOPN <PMC:X machine side signal><DCS PMC:X machine side signal> (for each safety door) Input the guard state of the protective door to this signal. When the protective door is open (Guard State signal (*SGOPN) =0), set Safety Check Request signal (*VLDVx, *VLDPs) to “0” in order to activate the alarm monitoring of safety functions. [Classification] [Function]

[Operation]

Input signal (Dual signal) Guard State signal informs CNC of the guard open/closed state for the Dual Check Safety Function. 0: Guard open state 1: Guard closed state When Guard State signal (*SGOPN) is “0”, the ladder program turn Safety Check Request signal (*VLDVx, *VLDPs) to “0” in order to activate the alarm monitoring of safety speed, safety machine position and safety position error. If the ladder program detects abnormal condition in each CPU, it generates a safety related alarm and stops motors.

IMPORTANT As for the contacts for Guard State signal, it is recommended to fulfill the Standard IEC60947-5-1. - 58 -

Page 67

5.I/O SIGNALS

B-64004EN/02

MCC Contact State (input) *SMC <PMC: Gn748#6><DCS PMC: G(000+m)#6> (for each machine group) The state of MCC contact is checked doubly. It is not possible to check whether the contact of MCC is melted and adhered abnormally because MCC contact is closed during normal operation. The state of MCC contact can be checked by performing MCC off Test. [Classification] [Function]

[Operation]

Input signal (Dual signal) MCC Contact State signals (*SMC) inform CNC of the MCC state for the Dual Check Safety Function. 0: MCC-on state 1: MCC-off state MCC Contact State signals (*SMC) is used to check if the MCC Off signals (*MCF) operates normally in MCC off Test mode. When the MCC Contact State signals (both *SMC(PMC) and *SMC(DCS PMC)) are 1 in the emergency stop state (*ESP=0), it is possible to design the ladder program to release the guard lock.

CAUTION Input this signal according to the MCC state. Safety Check Request signal (input) *VLDVx <PMC:Gn750#0 to #7><DCS PMC:G(002+m)#0 to #7> (for each axis) *VLDPs <PMC:Gn751#0 to #3><DCS PMC:G(003+m)#0 to #3> (for each spindle) If these signals are set to “0” when Guard State signal (*SGOPN: machine side signal) is “0”, the alarm monitoring of safety speed, safety machine position and safety position error is activated. [Classification] [Function]

[Operation]

Input signal (Dual signal) Safety Check Request signals request each CPU to carry out the safety check for the Dual Check Safety Function. These signals select a servo axis and a spindle that must be checked when a protective door is open. 0: Alarm by safety check is monitored, as a protective door is open. 1: Alarm by safety check is not monitored, as a protective door is closed Each CPU carries out the safety check of the servo axis and the spindle that are selected by these signals. (Safety speed for a spindle, safety speed, safety machine position and safety position error for a servo axis.) If each CPU finds out any problem, it generates a safety related alarm and stops motors.

- 59 -

Page 68

5.I/O SIGNALS

B-64004EN/02

Guard Open Inhibit signal (output) *OPIHB <PMC: Fn191#0><DCS PMC: F(019+m)#0> (for each machine group) CNC returns these signals as answer when CNC detects that Guard Open Request signal (ORQ) is set to “1”. [Classification] [Function]

[Operation]

Output signal (Not checked doubly) When CNC receives Guard Open Request signal (ORQ) =1, CNC returns these signal as answer. CNC outputs Guard Open Inhibit signal (*OPIHB) through both PMC and DCS PMC. 0: Inhibit guard open 1: Permit guard open A machine tool builder can release a guard lock by his ladder program when Guard Open Inhibit signal (*OPIHB) =1, Monitoring Result signal (RSVx/RSPs) =1 and the condition of machine side is confirmed to be safe.

IMPORTANT The mistake of the ladder program cannot be checked. So be sure to perform the confirmation of the safety function. (refer to the chapter 7) Monitoring Result signal (output) RSVx <PMC:Fn750#0 to #7><DCS PMC:F(002+m)#0 to #7> (for each axis) RSPx <PMC:Fn751#0 to #3><DCS PMC:F(003+m)#0 to #3> (for each spindle) These signals show the result of monitoring safety speed, safety machine position and safety position error. By checking these signals, a machine tool builder can judge whether a machine is in safe state or not. When a machine is judged to be in safe state, it is necessary to turn on the signal for releasing a guard lock and outputs a signal actually to open a protective door. [Classification] [Function]

[Operation]

Output signal (Output to both PMC but not checked doubly) These signals show the result of monitoring of the Dual Check Safety Function. These signals notify that an abnormal condition is detected in safety monitoring function of the Dual Check Safety Function, such as safety speed check, safety machine position check and safety position error check. In the following case, these signals are turned to “0”. 0: In dangerous condition (Abnormal condition is detected by safety function.) In the following case, these signals are turned to “1”. 1: In safe condition (Abnormal condition is not detected.) Each CPU notifies PMC of the result of safety monitoring through these signal. A machine tool builder can release a guard lock by his ladder program when Guard Open Inhibit signal (*OPIHB) =1, these Monitoring Result signal (RSVx/RSPx) =1 and the condition of machine side is confirmed to be safe. - 60 -

Page 69

5.I/O SIGNALS

B-64004EN/02

MCC Off signal (output) *DCALM <PMC: F0748#7><DCS PMC: F000#7> (for all system) In case this signal is “0”, MCC is shut off through 2 channels of I/O line respectively. This signal is set to “0”, when a crosscheck alarm of safety related signals or a CPU self-diagnosis alarm occurs. A machine tool builder makes a ladder program to output a signal to shut off MCC when this signal is turned to “0”. If necessary, control DO signal for peripheral devices. [Classification] [Function]

[Operation]

Output signal (This signal output to both PMC but is not monitored doubly) This is a signal to turn on MCC when both a crosscheck alarm and a CPU self-diagnosis alarm are not caused. 0: MCC off 1: MCC on When each CPU finds out any abnormal condition, it generates an alarm and turns off this signal at the same time.

MCC Off signal (output) *MCF <PMC: Fn748#1, DCS PMC: F(000+m)#1> (for each machine group) In case this signal is “0”, MCC is shut off through 2 channels of I/O Link line respectively. This signal is set to “0”, when Emergency Stop signal (*ESP ) is “0” or MCC off Test is carried out. A machine tool builder makes a ladder program to output a signal to shut off MCC when this signal is turned to “0”. [Classification] Output signal (This signal output to both PMC but is not monitored doubly) [Function] When the Dual Check Safety Function is applied, this signal allows turning on MCC. When either MCC Off signal through PMC or that through DCS PMC is “0”, MCC is turned off. When both MCC Off signal through PMC and that through DCS PMC is “1”, MCC is turned on. 0: MCC off 1: MCC on [Operation] When Emergency Stop signal is input, CNC turns off this signal. When MCC off Test is carried out, CNC turns off this signal, too. [Output condition] In the following case, this signal turns to “0” (not permit MCC on) MCC off Test is carried out. In emergency stop state In other than the above case, this signal turns to “1” (permit MCC on).

- 61 -

Page 70

5.I/O SIGNALS

B-64004EN/02

MCC Off signal (output) *MCFVx <PMC: Fn752#0 to #7><DCS PMC: F(004+m)#0 to #7> (for each axis) In case this signal is “0”, MCC is shut off through 2 channels of I/O line respectively. This signal is set to “0”, when an alarm occurs in safety speed check, safety machine position check or safety position error check for each servo axis. A machine tool builder makes a ladder program to output a signal to shut off the MCC of the path that the axis belongs, when this signal is turned to “0”. [Classification] [Function]

[Operation]

Output signal (This signal output to both PMC but is not monitored doubly) When the Dual Check Safety Function is applied, this signal allows turning on MCC. 0: MCC off 1: MCC on If each CPU finds out the abnormal state of the axis when Safety Check Request signal for the axis (*VLDVx)=0, each CPU brings the axis into controlled stop state at first. In case of an alarm of Safety Speed Monitoring or Safety Machine Position Monitoring, each CPU watches whether the axis is decelerated and stopped or not. If the axis does not stop, each CPU turns this signal corresponding to the alarm axis to “0”. In case of an alarm of Safety Position Error Monitoring, each CPU turns this signal corresponding to the alarm axis to “0” immediately. In case of an alarm other than described above and related to data communication or position detector, each CPU turns this signal corresponding to the alarm axis to “0” immediately. But according to the parameter setting, it is possible to turn to “0” this signals of all the axes belonged to the path that involves the alarm axis in case of any servo alarms.

MCC Off signal (output) *MCFPs <PMC: Fn753#0 to #3><DCS PMC: F(005+m)#0 to #3> (for each spindle) In case this signal is “0”, MCC is shut off through 2 channels of I/O Link line respectively. This signal is set to “0”, when an alarm occurs in safety speed check for each spindle. A machine tool builder makes a ladder program to output a signal to shut off the MCC of the path that the spindle belongs, when this signal is turned to “0”. [Classification] [Function]

[Operation]

Output signal (This signal output to both PMC but is not monitored doubly) When the Dual Check Safety Function is applied, this signal allows turning on MCC. 0: MCC off 1: MCC on If each CPU finds out safety speed over alarm in safety speed monitoring when Safety Check Request signal for the spindle (*VLDPs)=0, each CPU brings the spindle into free run state at first. - 62 -