Manual · Fanuc
FANUC Series 30i/31i/32i-MODEL A Dual Check Safety Operator's Manual
Manual174 pagesPDF 1.7 MB
Operator's manual for Dual Check Safety on FANUC Series 30i, 31i and 32i-MODEL A CNCs: safety functions, signals, parameters.
What this file really is
The old site listed this file as a manual for the Fanuc A03B-0807-C159, ABU05A and 39 more models. The file is named as a user manual for the ABU05A, but it is the FANUC Series 30i/31i/32i-MODEL A Dual Check Safety operator's manual and does not name that part.
Filed with · 41 models
Also filed with these models on the old site
Summary
What is in it
FANUC operator's manual for the Dual Check Safety function of the Series 30i/300i/300is, 31i/310i/310is and 32i/320i/320is-MODEL A CNCs. It explains the two-channel safety principle and EN954-1 Category 3 compliance, then covers system configuration, each safety function (safe stop, emergency stop, safe speed and safe machine position monitoring, MCC off test), installation, I/O signals, parameters, start-up and acceptance testing, alarm messages, diagnosis screens, sample connections and a components list.
Its parts
- Overview
- System Configuration
- Safety Functions
- Installation
- I/O Signals
- Parameters
- Start-up
- Alarm Message
- Diagnosis
- Sample System Configuration
- Components List
From the manual
Key facts from this manual
Each line names its page in the PDF.
Operator's manual (B-64004EN/02) for the Dual Check Safety function of FANUC Series 30i/31i/32i-MODEL A CNCs, which has two CPUs check motor speed and position and cut motor power on a mismatch. It covers the safety functions, I/O signals, parameters, start-up, alarm messages and diagnosis screens. It is not a manual for the ABU05A or the other I/O parts the site files it under: they appear only in its hardware components list.
- What it covers
- Dual Check Safety: two independent CPUs in the CNC monitor motor speed and position p. 9
- Applicable CNCs
- FANUC Series 30i/300is/300i, 31i/310is/310i (and A5), 32i/320is/320i p. 20
- Controlled axes
- Up to 32 (30i), 20 (31i), 9 (32i) p. 20
- Error response
- Motor power is cut (MCC off) through two independent paths p. 13
- Safety I/O path
- Guard and other safety signals come in through an I/O unit on the I/O Link p. 13
- I/O parts listed
- Bases ABU05A (5-slot horizontal) and ABU10A (10-slot horizontal), interface AIF01A, modules such as AID16D, AIA16G, AOD32D1, AOR08G, AOR16G p. 149, 150
- Amplifiers
- Alpha and alpha i servo and spindle amplifiers, beta i servo amplifiers, power supply modules p. 20
- Detectors
- Detectors built into the motors, such as Pulsecoder alpha A1000 and spindle M, MZ, BZ, Mi, MZi, BZi, CZi sensors p. 21
- Software option
- Dual check safety software option p. 21
- Software revisions
- CNC G001, G011, G021 (23~); PMC 406N (13~); servo 90D0, 90E0, 90D3, 90E3; spindle 9D70 (A4~) p. 152
- Power supply modules
- Alpha i PSM-5.5i to PSM-55i (A06B-6110-H006 to -H055) and PSMR-1i to -5.5i p. 153
- Alarm groups
- SV servo, SP spindle, PW power-off and DS other alarms p. 123, 125
- IP protection
- Servo motors IP55; spindle motors IP54 with oil seal, IP40 without; amplifiers IP1x p. 52
- Safety standard
- The manual states the function meets EN954-1 Category 3 p. 13
What this manual walks you through
- Safe speed and safe machine position monitoring p. 5
- Running the MCC off test of the safe stop function p. 5
- Setting the safety-related parameters p. 6
- Start-up, acceptance test and report p. 6
- Reading and clearing Dual Check Safety alarms p. 123, 124, 125
- Using the cross check and MCC off test diagnosis screens p. 6
- Wiring the 2-channel I/O Link for safety-related I/O p. 53
- Sample connections for emergency stop and guard signals p. 7
- Machine groups and multi path control p. 6
- Conditions for third-party motors and encoders p. 7
Good to know
- The function cannot monitor the stop state of the motors. p. 10
- It works only with the motors, built-in detectors and amplifiers FANUC specifies. p. 9
- A safety-related hardware and software test must be run at set intervals. p. 9
- Some system alarms cannot be cleared by reset; power must be turned off. p. 123
- Servo and spindle amplifiers and the CNC are to be installed in IP54 cabinets. p. 52
Questions this manual answers
What does FANUC alarm SV0488 SELF TEST OVER TIME mean?
The MCC off test did not finish within the time set in parameter 1946; the manual says to check the MCC contact. p. 123
What does alarm DS0022 DUAL CHECK SAFETY IS NOT WORKED mean?
Dual Check Safety is unavailable because parameter 1902#6 is set to 0. p. 125
How do I clear a Dual Check Safety alarm?
A reset clears it once the abnormal condition is gone; system-related alarms need the power turned off. p. 123
Which FANUC CNCs support Dual Check Safety?
Series 30i/300is/300i, 31i/310is/310i (including A5) and 32i/320is/320i. p. 20
What is the FANUC ABU05A in this manual?
Its components list names the ABU05A as a 5-slot horizontal base; the manual gives no other detail on it. p. 150
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 18 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
- Pages 161 to 170161-170
- Pages 171 to 174171-174
The file