Software - Dual check safety software option DETECTOR SYSTEM The detectors below can be used. Feed axis detector -Pulsecoder αA1000, αA64, - αA16000i, αA1000i, αI1000i, αA64i - βA64B, βA32B - βI64B, βI32B - Separate type detector (A quard B) Spindle detector - M sensor - MZ sensor - BZ sensor - Mi sensor - MZi sensor - BZi sensor - CZi sensor High Resolution Serial output circuit
- 13 -
Page 22
3.SAFETY FUNCTIONS
3
B-64004EN/02
SAFETY FUNCTIONS
- 14 -
Page 23
3.SAFETY FUNCTIONS
B-64004EN/02
3.1
APPLICATION RANGE The dual check safety function assumes the following configuration: A) At least, one protective door is provided. B) If protective door is closed, safety is assured. When the operator makes a request to open the protective door, the safety functions are enabled, and the protective door can be unlocked. While the protective door is open, the active safety functions assure safety. When the request to open the protective door is canceled, the protective door is locked, and the safety functions are disabled. The dual check safety function provides these safety functions while the protective door is open, as described above. Some of the safety functions continue working while the protective door is closed.
WARNING Each machine tool builder should take measures to assure safety while the protective door is closed and to ensure safety related to a rotation axis and travel axis. At the same time, safety measures for the FANUC servo motor or spindle motor need to be taken, while the door is open.
Safety function The dual check safety function has the following safety functions: •
• •
Safe-related I/O signal dual monitoring Emergency stop input, protective door open/close state, relay state for turning off the MCC Output signal for shutting off the power (turning the MCC off) To detect the latent cause of an abnormal state of this output, a MCC off Test must be made. Spindle motor Safe speed monitoring Servo motor Safe speed monitoring Safe machine position monitoring Safe position error monitoring
- 15 -
Page 24
3.SAFETY FUNCTIONS
B-64004EN/02
CAUTION This safety function is enabled while the protective door is open after a request to open the protective door is made. If the request to open the protective door is canceled and if the protective door is closed, this safety function is disabled. The dual input check of the safe-related I/O signal monitoring function and the emergency stop function are always active, regardless of whether the protective door is opened or closed. The CNC and the spindle check the safe speed of the spindle motor in redundant mode.
CNC
Dual monitoring of emergency stop signal
Emergency stop
Spindle
CNC
Cross check
Spindle motor
SPM
Safety related signal is checked by the CNC(DCS PMC) and the PMC in redundant mode
Safe speed monitoring
DCS PMC
Servo motor
SVM
Safe speed of servo motor and machine position are checked by the CNC and the Servo in redundant mode
Cross check PSM
Servo
Dual monitoring
Safe speed monitoring. Safe machine position monitoring. Safe position error monitoring.
of MCC Power down direction
Protective door
PMC Power down
Protective door lock
Dual monitoring of MCC Dual power down Detection of latent cause of error by MCC off test signal
Door lock open/close monitoring
Power down (MCC)
Dual monitoring of protective door state
- 16 -
Page 25
3.SAFETY FUNCTIONS
B-64004EN/02
3.2
BEFORE USING THE SAFETY FUNCTION
3.2.1
Important Items to Check Before Using the Safety Function When using the safety function for the first time upon assembly of the machine, replacing a part, or changing a safety parameter (such as a safe speed limit or safe range as described in Chapter 6), the user must check that all safety parameters are correct and that all safety functions are working normally. A return reference position must be made on each axis. The user must also check the absolute position of the machine. For details, see Chapter 7, “START UP.”
3.2.2
MCC off Test of the Safe Stop Function An MCC off Test of the safe stop function monitors the contact state of the electromagnetic contactor (MCC), compares the state with a command to the electromagnetic contactor, and checks that the safe stop function works normally. The user of the machine must carry out the test. This test must be carried out when the CNC is turned on or when 24 hours have elapsed after the previous test is completed. If the CNC is turned on or if 24 hours have elapsed after the previous test is completed, a guard open request (protective door open request) should not be accepted until the test is performed. A machine tool builder must make the ladder program to realize this sequence.
- 17 -
Page 26
3.SAFETY FUNCTIONS
B-64004EN/02
3.3
STOP
3.3.1
Stopping the Spindle Motor Because the spindle motor is an induction type motor, power-down during rotation causes the motor to continue rotating for a certain amount of time. From a safety standpoint, the motor may have to be stopped immediately. If an error is detected and the spindle is judged to be controlled, it is possible to stop spindle motor by the ladder program. In case of emergency stop and abnormal condition of safety related I/O, it is necessary to design the ladder program to shut off the power after waiting the specified time elapses. To speed down and stop the spindle, the PMC must input the spindle Emergency Stop signals (*ESPA(G71.1), *ESPB(G75.1), and so on). When this signal is input, the spindle slows down and stops. (A Ladder program for inputting this signal in case of alarm must be created.) The emergency stop input (connector CX4) of the PSM has the same effect. If the Emergency Stop signal is connected to emergency stop input (connector CX4) of the PSM, the spindle slows down and stops in the emergency stop state. If the spindle does not stop in spite of the stop command, the MCC is shut off. If this processing is not performed, power-down causes the spindle motor to continue rotating at the speed prior to power-down (and eventually stopping in the end).
CAUTION When the servo alarm related to the communication error or position detector is caused, MCC off signal corresponding to the spindle is output. Shut off the MCC after executing appropriate procedure such as spindle stop operation. According to the setting value of the parameter, MCC off signals of all axes, which belong to the same path of the spindle that causes an alarm, are output. Shut off the MCC after executing appropriate procedure such as spindle stop operation.
3.3.2
Stopping the Servo Motor Because the servo motor is a synchronous motor, power-down results in a dynamic brake stop. The dynamic brake stop is electric braking in which the excited rotor is isolated from the power source and the generated electric energy is used up in the winding. An internal resistor provides additional braking. Unlike an induction motor, the servo motor does not coast because of this function.
- 18 -
Page 27
3.SAFETY FUNCTIONS
B-64004EN/02
If the input of the Emergency Stop signal or an error of a safe-related signal or speed monitoring is detected, the CNC automatically specifies a command to zero the speed and reduces the speed to zero (controlled stop). After the motor slows down and stops, the power is turned off, and the motor is brought into the dynamic brake stop state. To slow down and stop the motor, some parameters must be specified in the CNC. If those parameters are not specified, the motor is immediately brought into the dynamic brake stop state. When abnormal state is detected in monitoring safety speed or so on, a dynamic brake stop is made.
3.3.3
Stop States The following stop states are possible.
Safe stop state The power to the motor is shut off (MCC off state) in this state. If the spindle motor can be controlled, the ladder program must shut off the power after the spindle motor is slowed down to a stop. If the spindle motor cannot be controlled, the power is immediately shut off. If the servo motor can be controlled, the motor is slowed down to a stop and then brought into the dynamic brake stop state. If the motor cannot be controlled, the motor is immediately brought into the dynamic brake stop state. If the power is shut off immediately, the spindle motor continues at the same speed prior to the abnormal event and eventually comes to a stop. If the spindle motor can be slowed down to a stop, the operation is performed as instructed by the PMC and then the power is shut off.
Controlled stop state The power to the motor is not shut off. The servo motor and the spindle motor are controlled to stop. In the controlled stop state of either motor, the safety function is active if the condition for enabling the safety function is satisfied (the door is open). If a further abnormal event occurs, the motor is brought into the safe stop state by the ladder program.
WARNING 1 The machine tool builder must design the machine so that the machine is kept in the stop state if the power to the servo motor driving circuit is shut off. Example) Brake mechanism that would not drop the vertical axis after the power is shut off 2 If the power to the spindle motor driving circuit is shut off, the spindle motor continues rotating at the speed before the power-down and eventually comes to a stop. A measure must be taken so that this coasting does not affect safety.
- 19 -
Page 28
3.SAFETY FUNCTIONS
3.4
B-64004EN/02
SAFE-RELATED I/O SIGNAL MONITORING A set of safe-related I/O signals are connected to the two channels of the I/O respectively. As for safe-related I/O signals, a pair of signals are prepared and connected to each I/O through different paths. The two independent CPUs individually check the input signals. If a mismatch between two corresponding signals is found, the system enters the safe stop state. The following safe-related I/O signals are monitored or output in redundant mode: • • • • • • • •
Emergency stop input signal Protective door state input signal (Request to monitor for each axis) Input signal for selecting safety speed monitoring and safety position monitoring Input signal for monitoring the MCC contact state Output signal for turning off the MCC (power-down) Output signal for position switch Output signal for brake control User defined safe-related I/O signals
In order to setup double monitoring system, machine tool builder must connect safety signals to both I/O Link #1, #2 and I/O Link#3, #4, Profibus-DP.
IMPORTANT If the safety input signals, except for Emergency Stop input signals, are connected to the I/O module, a Ladder program must be created to establish a one-to-one relationship between the actual input (X) and the input to the CNC (G). The duplicated input/output signals are always checked for a mismatch, regardless of whether the safety function is active or not. When a signal state changes, the pair of signals may not match for some period because of a difference in response. The dual check safety function checks whether a mismatch between the two signals continues for a certain period of time, so that an error resulting from the difference in response can be avoided. The check period must be specified as a safety parameter. Parameter number 1945
Name Safe-related input/output signal check timer
The following signals are not defined as safe-related I/O signals and are not duplicated. The signals, however, are necessary for the system. -
Input signal for making a protective door open request Input signal for starting the test mode Output signal for requesting a MCC off Test - 20 -
Page 29
3.SAFETY FUNCTIONS
B-64004EN/02
This section briefly describes the signals. For details, see Chapter 5, “OPERATION.” For specific connections, see the sample system configuration in Chapter 10.
NOTE 1 Dual Check Safety PMC (DCS PMC) 2 First path PMC, Second path PMC, Third path PMC Please refer to “FANUC Series 30i/300i/300is-MODEL A PMC PROGRAMMING MANUAL (B-63983EN)” 3 When I/O Link and PROFIBUS-DP are connected to DCS PMC at the same time, the X/Y signals cannot be allocated to PROFIBUS-DP. 4 Please activate “Broken wire detection” of the slave, which connect with PROFIBUS network as Safety-related I/O. As for detail, please refer to “6.6. PROFIBUS-DP parameter settings”. CAUTION Ladder functional instruction MOVB, MOVD and MOVW cannot be used with ladder for Dual Check Safety PMC. Use MOVN instead of them.
- 21 -
Page 30
3.SAFETY FUNCTIONS
B-64004EN/02
I/O related with Dual Check Safety Function PMC(n=path(0-9)) DCS PMC (m=path(0-9) x20) 1 2 3
Symbol *ESP
Signal name Emergency Stop signal
*SGOPN *VLDVx
Guard State signal Safety Check Request signal (Servo) Safety Check Request signal (Spindle) Safety Speed / Safety Position Selection signal (Servo) Safety Speed Selection signal (Spindle) MCC Contact State signal
*VLDPs SVAn/ SVBn SPAn/ SPBn *SMC
4 5
*DCALM
7
BRKx
MCC Off signal (for all system) MCC Off signal (for each machine group) MCC Off signal (for each servo axis) MCC Off signal (for each spindle) Safety Brake signal
8
SPS
Safety Position Switch signal
*MCF 6
*MCFVx *MCFPs
I/O address <X008#4,0,1> (PMC) <X008#4,0,1>(DCS PMC) Machine side signal <Gn750#0-#7> (PMC) <G(002+m)#0-#7>(DCS PMC) <Gn751#0-#3>(PMC) <G(003+m)#0-#3>(DCS PMC ) <Gn752/Gn753>(PMC) <G(004+m)/G(005+m)>(DCS PMC) <Gn754>(PMC) <G(006+m)>(DCS PMC) <Gn748#6>(PMC) <G(000+m)#6>(DCS PMC) <F0748#7>(PMC) <F000#7>(DCS PMC) <Fn748#1>(PMC) <F(000+m)#1>(DCS PMC) <Fn752#0-#7>(PMC) <F(004+m)#0-#7>(DCS PMC) <Fn753#0-#3>(PMC) <F(005+m)#0-#3>(DCS PMC) <Fn754#0-#7>(PMC) <F(006+m)#0-#7>(DCS PMC) <Fn755-Fn758>(PMC) <F(007+m)-F(010+m)>(DCS PMC)
Programmable Safety I/O signals
9 10 11 12
13
ORQ OPT *OPIHB
Guard Open Request signal Test Mode signal Guard Open Inhibit signal
RSVx
Monitoring result signal (Servo)
RSPs
Monitoring result signal (Spindle) MCC Off Test Execution Request signal Position Information Effect signal
14
RQT
15
POSEx
<Gn191#3>(PMC) <Fn191#2>(PMC) <Fn191#0>(PMC) <F(019+m)#0>(DCS PMC) <Fn750#0-#7>(PMC) <F(002+m)#0-#7>(DCS PMC) <Fn751#0-#3>(PMC) <F(003+m)#0-#3>(DCS PMC) <Fn191#2>(PMC) <Fn766#0-#7>(PMC) <F(018+m)#0-#7>(DCS PMC)
Dual input monitoring Dual input Dual input monitoring Dual input monitoring Dual input monitoring Dual input monitoring Dual input monitoring Dual output Dual output Dual output Dual output Dual output Dual output Dual input monitoring Dual output Input Input Dual output Dual output Dual output Output Dual output
Safe-related I/O 1. *ESP
Emergency Stop signal (input) This signal is Emergency Stop signal and is monitored in redundant mode. The signal is connected to the *ESP input of the servo amplifier as well.
- 22 -