Page 31

3.SAFETY FUNCTIONS

B-64004EN/02

2. *SGOPN

Guard State signal (Machine side input signal) The signal is provided for double monitoring of the protective door state. The signal is connected so that it is normally set to 1 while the protective door is closed and locked (door closed) and set to 0 otherwise (door opened). These states are implemented by the combination of the safety door and safety relays. The PMC ladder for safety check must check the state of axes by asserting the Safety Request signal, when a protective door is open.

3. *VLDVx, *VLDPs

Safety Check Request signal (input) These signals are monitored in redundant mode. These signals request safety check when a protective door is open. These signals are prepared for each axis and each spindle. CNC monitors these signals. If safe speed range of a servo motor is exceeded in the door open state, the system enters the controlled stop state. If an axis is still not stopped, the system enters the safe stop state. If safe speed range of a spindle motor is exceeded in the door open state, the spindle motor enters free run state. If the spindle motor is not decelerated, the system enters the safe stop state.

4. SVAx/SVBx,SPAs/SPBs

Safety Speed / Safety Position Selection signal (input) These signals are monitored in redundant mode. SVA/SVB are the signals to select safety speed / safety position for each servo axis. SPA/SPB are the signals to select safety speed for each spindle. (The values of safety speed / safety position are given by the parameters.)

5. *SMC

MCC Contact State signal (input) The MCC contact state is monitored in redundant mode. In normal operation, the MCC is closed, therefore whether the contact of a relay is in an abnormally closed state cannot be detected. In the test mode, it can be detected whether the contact of relay is abnormally closed.

6. *DCALM, *MCF, *MCFVx, *MCFPs

MCC Off signal (output)

With these signals, the MCC is shut off by 2 channels I/O when either one of these signals state is “0”. *DCALM is to allow turning off MCC of all system when I/O cross check alarm or some problems of safety check function are found. *MCF is to allow turning on MCC of each machine group according to emergency stop or MCC off Test. *MCFVx is to allow turning on MCC of each axis according to monitor safety speed of servo axis or so on. *MCFPs is to allow turning on MCC of each spindle according to the result of monitoring safety speed of spindle. These signals are assigned on both PMC and DCS PMC. Machine tool builder must output the signal to shut off MCC when either one of these signal is “0”.

7. BRKx

Safety Brake signal (output) These signals are output to control the brake of each servo axis. - 23 -

Page 32

3.SAFETY FUNCTIONS

B-64004EN/02

8. SPS1 to SPS32 (SPS33 to SPS64 in case of 2 or more path) Safety Position Switch (output) These signals show whether the machine position of each axis is stayed within the range specified by the parameters or not.

9. Programmable Safety I/O signals (input/output) The 8 bytes (64 bit) programmable safe I/Os can be freely defined as the different address from the above basic safe signals. Each byte of 8 byte programmable safe I/Os can be assigned on either address of X/Y or R or D by parameter. Each byte of the programmable safe I/O between the PMC and DCS PMC is cross-checked by the CNC and PMC. The combinations of cross-checking these signals are defined by using Safety parameters as follows. Signal type input output

Combination No. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

DCS PMC No.11950 No.11951 No.11952 No.11953 No.11954 No.11955 No.11956 No.11957 No.11960 No.11961 No.11962 No.11963 No.11964 No.11965 No.11966 No.11967

PMC No.11970 No.11971 No.11972 No.11973 No.11974 No.11975 No.11976 No.11977 No.11980 No.11981 No.11982 No.11983 No.11984 No.11985 No.11986 No.11987

Signals other than safe-related I/O The following signals are not safe-related signals (are not checked in redundant mode) but are important signals in the dual check safety system. The machine tool builder must create an appropriate Ladder program with these signals.

IMPORTANT The error of ladder program cannot be checked by safety function itself. Please make sure to check safety function (see Chapter 7). 10. ORQ

Guard Open Request signal (input) When this signal is input, the CNC set the Guard Open Inhibit signal (*OPIHB) to “1” (Guard open accept). The PMC ladder program of a machine tool builder confirms the safety machine position and the safety speed. If both machine position and speed are judged within safe range according to the result of confirmation, the guard unlock signal is set to 1 (guard unlock enabled). The machine tool builder - 24 -

Page 33

3.SAFETY FUNCTIONS

B-64004EN/02 must provide an output signal that opens the actual protective door through the PMC.

11. OPT

Test Mode signal (input) When the signal is input, a MCC off Test is executed. The MCC off Test checks whether the contact of the MCC is abnormally closed. When carrying out the MCC off Test manually, input this signal after the preparation of a MCC off Test is completed by the PMC.

12. *OPIHB

Guard Open Inhibit signal (output) When the Guard Open Request signal (ORQ) is input, the CNC sets this signal to “1”. The machine tool builder must design the PMC ladder logic by this signal. If this signal is set to “1”, the PMC confirms safety machine position and safety speed. If the result of confirmation is judged safe, PMC turns on the signal to release guard lock and outputs the signal to open the actual protective door. If the protective door is unlocked (*SGOPN becomes “0”) while the signal is set to 0, PMC will notify alarm occurrence to an operator by lighting a lamp or so on and bring the motor into the safe stop state.

NOTE This signal is not output while MCC off Test is carried out. 13. RSVx, RSPs

Monitoring Result signal (output) These signals show the result of monitoring safety machine position and safety speed of each axis and the result of monitoring safety speed of each spindle. When Guard Open Inhibit signal (*OPIHB) is set to “1”, a machine tool builder can judge whether the machine is in the safety state or not according to these signals. If safety is confirmed as a result, turn on the signal to unlock the guard lock and output the signal to open the actual protective door.

14. RQT

MCC Off Test Execution Request signal (output) If the execution of a MCC off Test is required, this signal is output. At power-on, this signal is always output. If this signal is output, a MCC off Test must be executed.

15. POSEx

Position Informaion Effect signal (output) This signal is output when Dual Check Safety Function is effective and the reference point is established. When the reference point is not established, the machine system is in danger state because Safety Machine Position Monitoring and Safety Position Error Monitoring are not active. If this signal is “0”, Machine Tool Builder has to control not to open the protective door.

- 25 -

Page 34

3.SAFETY FUNCTIONS

B-64004EN/02

Guard Open Request signal and Guard Unlock signal CNC(PMC)

Door open request 24V

G ORQ

X Ladder

Protective door

ORQ-I Y

*OPIHB

F

RSVx RSPx

F

POSEx

Ladder Protective door lock

F

The figure shows a sample connection of the protective door open request switch and the guard unlock signal. In the normal state, the door lock state is changed as follows before the safety monitoring state is established.

Door lock state transition ORQ-I

ORQ

*OPIHB

RSVx RSPs

POSEx

A

0

0

0

Protective door lock (*SGOPN) Locked

B C1

1 1

0 1

0 0

Locked Locked

C2 D

1 1

1 1

1 1

1

1

E

1

1

1

1

1

Unlocked (*SGOPN=0)

D

1

1

1

1

1

Locked

F

0

1

1

1

1

Locked

G

0

0

1

1

1

Locked

A

0

0

0

Locked Locked

Locked

- 26 -

A protective door open request is not made, and the door is locked. A guard open request is made. The request is transferred to the CNC. The CNC receives the request. Reference point is established and a safe speed check, a machine position check and a position error check prove that there is no failure and that the CNC can enter the safe state. The actual safety door is unlocked. Operations can be performed with the door open. The door is closed and locked again. The guard open request is canceled. The request is transferred to the CNC. The CNC receives the request and exits from the safe state.

Normal operating state

Safety function is enabled.

Page 35

3.SAFETY FUNCTIONS

B-64004EN/02

IMPORTANT The PMC ladder must be designed to monitor whether the protective door is open (*SGOPN is set to 0) while ORQ is set to 0. If the door open is detected, the PMC ladder judges that an abnormal event has occurred and enters the safe stop state. This can occur, for instance, when the door happens to open (or to be unlocked) while machining is in progress with the protective door closed.

Timing diagram from door close state to door open state The following diagram shows the timings at which the door is opened and closed again. ORQ_P

ORQ

*OPIHB RSVx RSPs POSEx

Actual door unlock signal

*SGOPN (Safety related I/O signal) Door closed

Door closed

Door opened

Actual door unlock signal

(1)

(2)

(3)

(4)

(5)

t

(1) When the Guard Open Request signal (ORQ) is input, the CNC returns the answer signal (*OPIHB) to PMC. (2) The PMC ladder program checks that the machine position, speed and position error are within safe ranges by the Monitoring Result signal (RSVx/RSPs) and the reference point is established by the Position Information Effect signal (POSEx). Then, it turns on the guard unlock signal. This example assumes that the protective door has an electromagnetic lock mechanism. While the door is open, the unlock signal is turned off. (3) The door is open. (4) The protective door is closed and locked. After this, the Guard Open Request signal (ORQ) must be turned off. (5) When the Guard Open Request signal (ORQ) is turned off, the CNC turned off the answer signal (*OPIHB).

- 27 -

Page 36

3.SAFETY FUNCTIONS

B-64004EN/02

CAUTION Ensure a time of 100 ms or longer (“t” in the figure) from when the door is closed (locked) until the Guard Open Request signal (ORQ) goes off. If this time requirement is not satisfied, an alarm may be raised when the door is closed (locked). Design an operator panel to inform an operator that Guard Open Request signal (ORQ) is turned on by lighting a lamp.

- 28 -

Page 37

3.SAFETY FUNCTIONS

B-64004EN/02

3.5

EMERGENCY STOP The Emergency Stop signal is monitored in redundant mode. When the emergency stop is input, the servo motor slows down to a stop (*see the below caution) and enters the dynamic brake stop. The spindle slows down to a stop (*see the below caution) as instructed by the PMC (Ladder program), and then the power is shut off.

CAUTION To enable the function to slow down and stop the servo motor, the corresponding parameter must be specified. If the parameter is not specified, the motor immediately enters the dynamic brake stop state. The spindle motor slows down and stops as instructed by the PMC (Ladder program). If the PMC does not instruct this, the motor maintains the high speed prior to the power-down and coasts. If an illegal speed is specified because of a failure on the PMC side while the safety function is active (the protective door is open), the CNC enters the safe stop state. WARNING In the emergency stop state, the processing to open or close the protective door depends on the Ladder program created by the machine tool builder. For instance, if the protective door should not be opened in the emergency stop state, a Ladder program of the processing must be created. IMPORTANT Emergency Stop Button must fulfill the Standard IEC60947-5-1. This is mandatory.

- 29 -

Page 38

3.SAFETY FUNCTIONS

3.6

B-64004EN/02

SAFE SPEED MONITORING If the safe speed range is exceeded while the protective door is open, the dual check safety function immediately enters the stop state. If each axis or spindle is not stopped, the dual check safety function enters the safety stop state. For each feed axis and spindle, up to four safe speed ranges can be specified in safety parameters. Both the CNC and the SV/SP monitor whether a safe speed is kept on each feed axis and spindle. Limit speed can be changed by the Safety Speed / Safety Position Selection signals (SVAn/SVBn for feed axis, SPAn/SPBn for spindle). Safety Speed/Safety Position Selection signal SVAn/ SVBn/ SPAn SPBn

Name Safety speed 1 Safety speed 2 Safety speed 3 Safety speed4

0 1 0 1

0 0 1 1

Safety speed parameter Feedaxis

Spindle

No.13821 No.13822 No.13823 No.13824

No.4372 No.4438 No.4440 No.4442

When excess limit error is detected, Monitoring Result signal (RSVx/RSPs) is set to “0”. In this situation, if Safety Check Request signal (*VLDVx/ *VLDPs) is “0” and safety monitor is executed, an alarm is generated. Error detected CPU CNC SV SP

Alarm SV0494/SP0757 SV0476 SP9069(SPINDLE ALARM 69)

CAUTION 1 When an illegal speed is detected for the servo axis, if the axis is not stopped after the time specified in the parameter, the MCC Off signal (*MCFVx) is turned to “0”. 2 When an illegal speed is detected for the spindle axis, CNC checks whether the spindle speed decelerates continuously or not. If acceleration is detected, the MCC Off signal (*MCFPs) is turned to “0”.

- 30 -

Page 39

3.SAFETY FUNCTIONS

B-64004EN/02

IMPORTANT 1 A gear ratio, ball screw, and the like must be carefully selected so that a safe speed can be kept on the feed axis. 2 Before inputting the Guard Open Request signal (ORQ), reduce each axial speed and spindle speed to a safe speed range or below. If a speed exceeds the limit, do not unlock the protective door. The PMC ladder must be designed that the power to the driving circuit is shut off (safe stop state) if the door is forced open. WARNING The safe speed monitoring function monitors whether the traveling speed exceeds a specified limit. The function cannot monitor the stop state (zero speed). If an error causes a movement on the feed axis at a speed lower than the safe speed range while the protective door is open, for instance, the function cannot detect this state. The machine must be designed so that this state does not affect the safety of the machine system.

- 31 -

Page 40

3.SAFETY FUNCTIONS

3.7

B-64004EN/02

SAFE MACHINE POSITION MONITORING While the door is open, the dual check safety function checks whether the position on each feed axis is within the safe machine position range defined by safety parameters. If it detects a machine position beyond the safety range, the dual check safety function immediately enters the stop state. If each axis is not stopped, the dual check safety function enters the safety stop state. For each feed axis, up to four safe positions can be specified in safety parameters. Both the CNC and the Servo monitor whether each axis is within the safety position. The range of the safety machine position can be changed by the Safety Speed / Safety Position Selection signals (SVAn/SVBn for feed axis). Safety Speed/Safety Position Selection signal SVAn SVBn

Name Safety machine position 1 Safety machine position 2 Safety machine position 3 Safety machine position 4

Safety machine position parameter + direction - direction

0

0

No.13831

No.13832

1

0

No.13833

No.13834

0

1

No.13835

No.13836

1

1

No.13837

No.13838

When “out of position error” is detected, Monitoring Result signal (RSVx) is set to “0”. In this situation, if Safety Check Request signal (*VLDVx) is “0” and safety monitor is executed, an alarm is generated. Error detected CPU CNC SV

Alarm SV0495 SV0477

CAUTION 1 The safe machine position monitoring function does not keep monitoring the specified range. Only after the function detects that a position on a feed axis exceeds the range, the system enters the stop state. Accordingly, in the stop state, an over travel has occurred on the feed axis. The travel distance depends on the traveling speed and other conditions. 2 When an “out of position error” is detected, if the axis is not stopped after the time specified in the parameter, the MCC Off signal (*MCFVx) is turned to “0”. - 32 -