Page 41

3.SAFETY FUNCTIONS

B-64004EN/02

The user of the machine must first carry out a reference position return in order to obtain the initial position. If the reference position return is not carried out, the check function is disabled. This check function is enabled after the reference position is established. (The function cannot be disabled by any means after the reference position is established.) A safe machine position limit on each feed axis is specified in a safety parameter.

CAUTION A machine operator must confirm whether the machine reference position is established correctly by checking the actual machine position and position display of the CNC. At power-on, the safety function does not work. After power-on, the CNC checks whether a reference position return is completed. If the reference position return is completed and if the protective door is open, safe machine position monitoring, safe speed monitoring and safety position error monitoring are performed. Then, the safety functions start working. If the reference position return is not completed, safe machine position monitoring cannot be performed because the coordinates are not established. In this state, the machine position monitoring function is disabled. After a reference position return is made, this function is enabled. Depending on the safety parameter setting, however, an alarm may be raised. To avoid this alarm, specify the safe machine position parameters before making a reference position return.

CAUTION 1 The machine coordinate of the safety function is based on position feed back. So it does not always indicate the same value as the machine coordinate based on the summation of the command value. 2 This function is activated only in position control mode. This function is not activated in torque control mode.

- 33 -

Page 42

3.SAFETY FUNCTIONS

3.8

B-64004EN/02

MCC OFF TEST A MCC off Test must be carried out in intervals of 24 hours, so that the safety functions would not be damaged by a possible cause of failure. A message telling that the MCC off Test must be carried out is displayed at power-on or when 24 hours have elapsed after the previous MCC off Test. The machine tool builder must set up the machine not to open the protective door before a MCC off Test is not completed. The protective door can be opened only after the MCC off Test is carried out accordingly. A MCC off Test performs the test to turn on and off MCC by controlling *SMC signal in order to confirm whether the circuit to shut off MCC is normal. The MCC off Test is performed both on PMC and DCS PMC. If the MCC off Test is not completed within the time specified by the parameter No.1946 (MCC off Test timer), servo alarm SV0488 is generated. It is necessary to carry out the MCC off Test before the protective door is open, when power is on or 24 hours have elapsed after previous MCC off Test. The PMC ladder program must be designed to carry out the following control. <1> When MCC off Test request signal (RQT) is set to “1” at power-on or in case 24 hours are elapsed after the previous MCC off Test, the protective door is locked till the MCC off Test is performed. But the operator can operate the machine while the protective door is closed. <2> When the MCC off Test request signal (RQT) is turned to “0”, the protective door can be unlocked. Example) Test No. *MCF (PMC)

DO state during MCC off Test 1

2

3

4

5

*MCF (DCS PMC) *SMC (PMC) *SMC (DCS PMC) Timer limit Timer

Test start

Test completion

IMPORTANT Carry out the MCC off Test with the protective door closed. As the test shuts off the MCC, prepare the system for mechanical MCC shut-off before starting the MCC off Test. - 34 -

Page 43

3.SAFETY FUNCTIONS

B-64004EN/02

3.9

SAFETY POSITION SWITCH FUNCTION It is checked whether the machine position is within the range of safety position switch. The checked result is outputted to the Safety Position Switch signal. The correspondence between axes and each signal is specified by the parameters. In case of 1 path system, up to 32 points can be specified. And in case of 2 or more paths, up to 64 points can be specified. When a machine position of controlled axis is within a range, which is specified by the safety parameters, this signal is output. 1 0 Parameter setting value

Parameter setting value

The signals are output after establishment of the reference position. The signal is not output before the completion of return to reference position. The “machine position” is the actual machine position (which is calculated using feedback of position detector), not the commanded position. The comparison of position for safe position switch is executed in detection unit. If the machine position equals parameter setting value, the safe position switch signal is output. The safe position switch signal is not output for axis which the Dual Check Safety (No.1904#6(DCN=1)) is not applied to. Safety Position switch can be assigned up to 16 points per 1 group to the output signal (F area) and totally up to 4 groups can be used in the CNC system. Two areas per a path are provided to assign. It is possible to assign the signal to an appropriate area. Safe position switch signals can be assigned to arbitrary controlled axes. (All points can be also assigned to one axis.) The assignment of controlled axes is set by the safety parameters (No.13880 to No.13911, No.10501 to No.10532). And the signals can be also assigned to the rotary axes. When inconsistency between the position switch on PMC and that on DCS PMC is lasted for the time that is specified by the parameter No.1945, the safety function sets MCC Off signal (*DCALM) to “0” and generates the alarm “safe I/O cross check error” (PW0010/PW0011) .

- 35 -

Page 44

3.SAFETY FUNCTIONS

B-64004EN/02

NOTE The machine coordinate of the safety function is based on position feed back. So it does not always indicate the same value as the machine coordinate based on the summation of the command value. Two machine coordinates that are calculated by two CPU independently are not always the same because the position feedback is continuously changed a little. As there is a possibility that the condition of two signals is different from each other near the boundary, do not stop an axis near the boundary. CAUTION This function is activated only in position control mode. This function is not activated in velocity control mode and torque control mode. • Hysteresis Position switch sometimes turns on and off repeatedly near the boundary of position switch area by very small vibration of a servo motor. According to this problem, position switch is inconvenient to use. So “hysteresis” described below is applied. Maximum limit of position switch

Minimum limit of position switch

Width of hysteresis Width of hysteresis Activated area of position switch

Fig.3.9(a) Measuring area of position switch in case state of switch is “0” Minimum limit of position switch

Maximum limit of position switch

Activated area of position switch

Fig.3.9(b) Measuring area of position switch in case state of switch is “1”

The position switch is checked at every sampling period. When the minimum and maximum limit of position switch are given like above figure, activated area is checked by the area shown in the figure 3.9(a) considering hysteresis if the state of position switch measured at last time is “0”. And activated area is checked by the area shown in the figure 3.9(b) not considering hysteresis if the state of position switch measured at last time is “1”. According to this, it is possible to suppress frequent changing of position switch. - 36 -

Page 45

3.SAFETY FUNCTIONS

B-64004EN/02

3.10

SAFETY RELATED PARAMETERS CHECK FUNCTION At every power-on, the CNC checks whether the safety related parameters are destroyed and are transferred to the SV, the SP and the PMC normally or not. The SV, the SP and the PMC also check whether the safety related parameters are transferred from the CNC normally or not. If some problem is found in this check, an alarm is generated and the MCC is shut off. (*DCALM=0)

3.11

PARAMETER LOCK FUNCTION It is possible to lock the rewriting of the safety related parameters. The parameter No.3225 and No.3226 unlock these parameters. The following parameters are locked. No.980, No.981, No.982, No.1023, No.1240, No.1838, No.1839, No.1840, No.1841,No.1842, No.1902, No1904, No.1945, No.1946, No.1948, No.1950, No.3021,No.3022, No.3225, No.3717, ,No.3797, No.4372, No.4438, No.4440, No.4442, No.4448, No.10500-No.10596, No.11950-No.11957, No.11960-No.11967, No.11970-No.11977, No.11980-No.11987, No.13811, No.13821-No.13829, No.13831-No.13838, No.13840-No.13843, No.13880-No.13911, No.13920-No.13951, No.13960-No.13991

- 37 -

Page 46

3.SAFETY FUNCTIONS

3.12

B-64004EN/02

SEFETY POSITION ERROR MONITORING FUNCTION Both the CNC and the SV check whether the servo following error of each axis exceeds the limit of deviation specified by the parameters. If the servo following error exceeds, an alarm is generated and MCC OFF signal (*MCFVx) is output immediately. The relation between the safety monitoring state and the parameter of limit of deviation is shown in the following table.

Moving Stopping Servo-off

Safety monitoring is activated (In case *VLDVx =0) No.1838 No.1839 No.1840

Error detected CPU CNC SV

Safety monitoring is not activated (In case *VLDVx =1) No.1841 No.1842 No.1840

Alarm SV1072/SV1071/SV1069 SV0474/SV0475/SV1070

When position deviation exceeds the limit given by the parameter (No.1839 in stop state, No.1838 in moving state and No.1840 in servo off state) during safety monitoring, Monitoring result signal RSVx is set to “0” regardless of the state of Safety check request signal *VLDVx. This function is valid after the reference position return is finished or the follow-up of absolute position is finished in case an absolute position coder.

CAUTION This function is activated only in position control mode. This function is not activated in torque and velocity control mode.

- 38 -

Page 47

3.SAFETY FUNCTIONS

B-64004EN/02

3.13

AMPLIFIER CIRCUIT MONITORING FUNCTION The SV and the SP transmit the data of plural axes to amplifiers through one electronic circuit (LSI). The CNC, the SV and the SP check whether this transmission is performed normally without placing data on wrong address. In case of servo amplifier, the CNC axis numbers kept by the CNC are compared with the CNC axis numbers kept by the SV. In case of spindle amplifier, the spindle numbers kept by the CNC are compared with the spindle number kept by the SP. The checking sequence is as follows. [Checking sequence for servo amplifier] <1> When a servo amplifier is set up at the first time, an alarm SV0498 is generated. At that time, the CNC transfers the CNC axis numbers to the SV and the SV keeps the data. Then the power of all CNC system (amplifiers are included) must be turned off and on. When an alarm is generated after the configuration of servo amplifiers is changed, it is necessary to carry out the operation to send the CNC axis numbers to servo amplifiers. Set the parameter No.2212#4 to “1” then return to “0”. Then turned off the power of all CNC system (amplifiers are included.) <2> After the power-on, the CNC and the SV start monitoring the CNC axis numbers. The CNC monitors by comparing the CNC axis number kept by the CNC itself with that kept by the SV. The SV monitors by comparing the CNC axis numbers kept by the SV with that sent by the CNC. When some error is found, an alarm SV0478 or SV0496 is output, and MCC Off signal (*DCALM) is turned to “0”. [Checking sequence for spindle amplifier] <1> When spindle is set up, the spindle numbers are transferred from the SP to the CNC. <2> The CNC compares the spindle numbers kept by the CNC itself with that sent from spindle amplifier. If inconsistency is found, an alarm SP0756 is output and MCC Off signal (*DCALM) is turned to “0”. <3> The SP compares the spindle numbers with that kept by the SP. If inconsistency is found, alarm SP9070 (Spindle alarm 70) is output, and MCC Off signal (*DCALM) is turned to “0”.

- 39 -

Page 48

3.SAFETY FUNCTIONS

3.14

B-64004EN/02

SAFETY BRAKE SIGNAL OUTPUT FUNCTION The CNC and the SV output the Safety Brake signal (*BRKx) to control the mechanical brake. When this signal is “0”, mechanical brake must be activated. When this signal is “1”, mechanical brake is allowed to be released. These signals cannot be used with the ignore v-ready off for all axes signal <Gn066#0> and the ignore v-ready off for each axis <Gn192> at the same time. When the inconsistency between the break signal on PMC and that on DCS PMC is lasted for the time that is specified by the parameter No.1945, the safety function sets MCC Off signal (*DCALM) to “0” and generates the alarm “safe I/O cross check error” (PW0010/PW0011).

- 40 -

Page 49

3.SAFETY FUNCTIONS

B-64004EN/02

3.15

CPU SELF TEST FUNCTION The CNC, the PMC, the SV and the SP carry out the following self-diagnosis. If the error is detected, the alarm is generated and sets MCC Off signal (*DCALM) to “0”. <1> CPU check It is checked whether each CPU runs normally or not. It is checked whether the instructions related to safety function is executed normally or not. Error detected CPU CNC PMC SV SP

ALARM PW0014 PW0009 SV0484 SP9074(Spindle alarm 74)

<2> Program monitoring It is confirmed whether all safety related function run normally. Error detected CPU CNC PMC SV SP

ALARM PW0017 / SV0490 PW0008(DCS PMC) PW0009(PMC) SV0484 SP9076 (Spindle alarm 76) SP0755

<3> Cross check It is checked whether the result of the judgment about the safety related function of a CPU is consistent with that of another CPU. If some error is found, an alarm is output. SV relation SP relation

PMC relation

- 41 -

ALARM SV0490/SV0484 SP9072(Spindle alarm 72) SP9077(Spindle alarm 77) SP9078(Spindle alarm 78) SP0755 PW0008(DCS PMC) PW0009(PMC)

Page 50

3.SAFETY FUNCTIONS

3.16

B-64004EN/02

RAM CHECK FUNCTION ECC (Error Check and Correct) function is applied to the battery back-upped file memory. Then a single-bit error is corrected. And, when an error that cannot be corrected occurs, memory parity error is generated. Other memory for dual check safety is checked as follows:(If the error is detected, the alarm is generated and sets MCC Off signal (*DCALM) to “0”) 1) Test at power-on The several test patterns are written to the RAM area. It is checked whether the written test data are read correctly. If read error occurs, an alarm is generated. 2) Test during normal operation RAM area is checked in turn at constant interval during normal operation. The several test patterns are written to the RAM. It is checked whether the written test data are read correctly. If read error occurs, an alarm is generated. Alarm detected CPU CNC SV PMC SP

3.17

Alarm PW0016 SV0484 PW0008(DCS PMC) PW0009(PMC) SP9016(Spindle alarm 16)

CRC CHECK FUNCTION At power-on and after power on, the data that are related to Dual Check Safety and stored in the ROM area are checked. The CNC software, the servo software, the PMC software and the spindle software are checked. If some error is found, an alarm is generated. After power on Error detected Software CNC software Servo software PMC management software Spindle software

Alarm CRC CHECK ERROR: NC BASIC. SERVO ROM TEST: CRC CHECK ERROR LED “6” Spindle alarm 75

After power on Error detected Software CNC software PMC management software

- 42 -

Alarm PW0018 CRC CHECK ERROR SYS-ALM199 NON MASK INTERRUPT OTHER-CPU