Page 11
1.OVERVIEW
B-64004EN/02
1.1
DIRECTIVE AND STANDARDS
1.1.1
Directives Machine tools and their components must satisfy the EC directives listed below. The FANUC CNC systems with the dual check safety function are compatible with all of these directives.
Directive Directive 98/37/EC Directive 89/336/EEC Directive 73/23/EEC
1.1.2
1998 Safety of machinery 1989 Electromagnetic compatibility 1973 Low Voltage Equipment
Related Safety Standards To be compatible with the directives, especially the machine directive, the international standards and European standards need to be observed.
Important safety standards EN292-1 1991 EN292-2 1991 EN954-1 1996 EN1050 1996 EN60204-1 1997 DIN V VDE0801 (1990) including amendment A1(1994)
1.1.3
Safety of machinery - Basic concepts, general principles for design – Part 1: Basic terminology, methodology Safety of machinery - Basic concepts, general principles for design – Part 2: Technical principles and specifications Safety of machinery - Safety-related parts of control systems – Part 1: General principles for design Safety of machinery - Principles for risk assessment Safety of machinery - Electrical equipment of machines Part 1: General requirements Principles for computers in safety- related systems
Risk Analysis and Evaluation According to the machine directive, the manufacturer of a machine or machine components and a responsible person who supplies a machine or machine components to the market must conduct risk evaluation to identify all risks that can arise in connection with the machine or machine components. Based on such risk analysis and evaluation, a machine and machine components must be designed and manufactured. Risk evaluation must reveal all remaining risks and must be documented.
-3-
Page 12
1.OVERVIEW
B-64004EN/02
1.2
DEFINITION OF TERMS
1.2.1
General Definition of Terms Reliability and safety Reliability and safety are defined by EN292-1 as follows: Term Reliability
Safety
1.2.2
Definition Capability of a machine, machine component, or equipment to perform its required function under a specified condition for a specified period Capability of a machine to perform its function without injuring the health under a condition of use for an intended purpose specified in the operator's manual and allow its transportation, installation, adjustment, maintenance, disassembly, and disposal
Definition of Terms Related to the Safety Function Safety-related I/O signal Safety-related I/O signals are input/output signals monitored by two systems. These signals are valid for each feed axis and spindle with a built-in safety function, and are used with each monitoring system. Example: Protection door state signal Safety stop When a safety stop occurs, power to the drive section is shut off. The drive section can generate neither a torque nor dangerous operation. The following are measures for incorporating the safety stop feature: Contactor between the line and drive system (line contactor) Contactor between the power section and drive motor (motor contactor) If an external force is applied (such as a force applied onto a vertical axis), an additional measure (such as a mechanical brake) must be securely implemented to protect against such a force. Safety limitation speed When the drive system has reached a specified limitation speed, a transition is made to the safe stop state. A measure must be implemented to prevent a set limitation speed from being changed by an unauthorized person. Safety machine position When the drive system has reached a specified positional limit, a transition is made to the safety stop state. When a positional limit is set, a maximum move distance traveled until a stop occurs must be considered. A measure must be implemented to prevent a set positional limit from being changed by an unauthorized person.
-4-
Page 13
1.OVERVIEW
B-64004EN/02
1.3
BASIC PRINCIPLE OF DUAL CHECK SAFETY
1.3.1
Features of Dual Check Safety Dual Check Safety function has the following features. Two-channel configuration with two or more independent CPUs Cross-check function for detecting latent errors Detection A servo motor detector signal is sent via the servo amplifier and is applied to the CNC through the FSSB interface. Then, it is fed to two CPUs: a CNC CPU and a Servo CPU. A spindle motor detector signal is sent via the spindle amplifier and is applied to the CNC connected through the serial interface. Then, it is fed to two CPUs: a CNC CPU and a CPU built into the spindle amplifier. The safety related signal such as guard signal is sent via the independent I/O unit and is applied to the CNC through the I/O link interface. Then, it is fed to two CPUs: a CNC CPU and a PMC CPU. Evaluation The safety function is monitored independently by a CNC CPU and servo CPU or by a CNC CPU and spindle CPU. Each CPU cross-checks data and results at certain intervals. Response If the monitoring function detects an error, the CNC CPU and the servo/spindle CPU switch off the MCC via independent paths to shut off the power to the feed axis and spindle.
1.3.2
Compliance with the Safety Standard (EN954-1, Category 3) The dual check safety function satisfies the requirements of Category 3 of the safety standard EN954-1. Category 3 requires the following: The safety function of a safety-related portion must not degrade when a single failure occurs. Single errors must be detected at all times when natural execution is possible. To satisfy these requirements, the dual check safety function is implemented using the two-channel configuration shown below.
-5-
Page 14
1.OVERVIEW
B-64004EN/02
CNC CPU Motor detector signal
Shut off power
Magnetic
Cross-check of data and results
Servo Spindle CPU contactor 電磁接触器
PMC CPU
Shut off power
Door switch signal
Monitoring of servo motor and spindle motor movement Data output from the detector built into each motor is transferred to the CNC through the amplifier. The safety of this path is ensured by using motors and amplifiers specified by FANUC. Cross-monitoring using 2 CPUs Two CPUs built into the CNC are used to cross-monitor the safety function. Each CPU is periodically checked for errors. If one system fails, the servo system and spindle can be stopped safely. Power shutoff via two paths If an error is detected, the power is shut off via two power shutoff paths. The paths need to be tested for built-up failures within a certain time. Input signal safety Safety-related input signals such as the protection door lock/unlock signal are monitored doubly. If a mismatch between the two occurrences of a signal is detected, the power to the motor drive circuit is shut off. This cross-check is constantly made. Output signal safety A signal is output (via two paths) to the relay used to shut off the power to the motor drive circuit. An error is detected by a MCC off Test. For detection of built-up failures, a MCC off Test needs to be conducted at certain intervals. This MCC off Test is not mandatory when machining is performed with the protection door closed. (The MCC off Test should be performed, before the protection door is open after the certain intervals.)
-6-
Page 15
1.OVERVIEW
B-64004EN/02
1.3.2.1
Latent error detection and cross-check Detection of latent errors This detection function can detect latent software and hardware errors in a system that has a two-channel configuration. So, the safety-related portions of the two channels need to be tested at least once within an allowable period of time for latent errors. An error in one monitoring channel causes a mismatch of results, so that a cross-check detects the error.
CAUTION Forced detection of a latent error on the MCC shutoff path must be performed by the user through a MCC off Test (after power-on and at intervals of a specified time (within normally 24 hours)). When the system is operating in the automatic mode (when the protection door is closed), this detection processing is not requested as mandatory. But, before the protection door opens after the specified time, the detection processing is required mandatory. If this has not been performed, lock for the protection door should not be released. Cross-check A latent safety-related error associated with two-channel monitoring can be detected as a result of cross-checking. For numeric data, an allowable difference between the two channels is set in a parameter. (For example, an allowable cross-checked difference is set for the actual position.)
NOTE An error detected as the result of forced latent error detection or cross-checking leads to a safety stop state. (See Chapter 3.3.3).
1.3.2.2
Safety monitoring cycle and cross-check cycle The safety function is subject to periodical monitoring in a monitoring cycle. The following functions are monitored at every 8ms. - Safe speed monitoring (servomotor) - Safe machine position monitoring (servomotor) - Safe position error monitoring (servomotor) The cross-check cycle represents a cycle at which all I/O data subject to cross-checking is compared. Cross-check cycle: 8 ms
-7-
Page 16
1.OVERVIEW
1.3.2.3
B-64004EN/02
Error analysis Error analysis The table below indicates the results of system error analysis controlled by the dual check safety function. Error analysis when the protection door is open Error Excessive speed for Spindle axis Excessive speed for feed axis Feed axis safety machine position error Input/output signal error
Cause Amplifier or control unit failure, operation error, etc. Amplifier or control unit failure, operation error, etc. Amplifier or control unit failure, operation error, etc. Wiring error, control unit failure, etc.
Action Safety limitation speed monitoring function EN60204-1 Category 1/0 stop Safety limitation speed monitoring function EN60204-1 Category 1/0 stop Safety machine position monitoring function EN60204-1 Category 1/0 stop Safe-related I/O signal monitoring function EN60204-1 Category 1/0 stop
Error analysis when the protection door is closed Error Input/output signal error
1.3.2.4
Cause Wiring error, control unit failure, etc.
Action Safe-related I/O signal monitoring function EN60204-1 Category 1/0 stop
Remaining risks The machine tool builder is to make a failure analysis in connection with the control system and determine the remaining risks of the machine. The dual check safety system has the following remaining risks: a)
b)
c) d)
The safety function is not active until the control system and drive system have fully powered up. The safety function cannot be activated if any one of the components of the control or drive is not powered on. Interchanged phases of motor connections, reversal in the signal of encoder and reversal mounting of encoder can cause an increase in the spindle speed or acceleration of axis motion. If abnormal speed detected, system controlled to brake to zero speed, but no effective for above error. MCC off is not activated until the delay time set by parameter has expired. Electrical faults (component failure etc.) may also result in the response described above. Faults in the absolute encoder can cause incorrect operation of the safety machine position monitoring function. With a 1-encoder system, encoder faults are detected in a single channel, but by various HW and SW monitoring functions. The parameter related to encoder must be set carefully. Depending on the error type, a category 0 or category 1 stop function according to EN60204-1 is activated.
-8-
Page 17
1.OVERVIEW
B-64004EN/02 e)
The simultaneous failure of two power transistors in the inverter may cause the axis to briefly (motion depend on number of pole pairs of motor) Example: An 8-pole synchronous motor can cause the axis to move by a maximum of 45 degrees. With a lead-screw that is directly driven by, e.g.16mm per revolution, this corresponds to a maximum linear motion of approximately 2.0mm. f) When a limit value is violated, the speed may exceed the set value briefly or the axis/spindle overshoot the set point position to a greater or lesser degree during the period between error detection and system reaction depending on the dynamic response of the drive and the parameter settings (see Section Safety-Functions) g) The category 0 stop function according to EN60204-1 (defined as STOP A in Safety Integrated) means that the spindles/axes are not braked to zero speed, but coast to a stop (this may take a very long time depending on the level of kinetic energy involved). This must be noted, for example, when the protective door locking mechanism is opened. h) Amplifiers (drive power modules) and motors must always be replaced by the same equipment type or else the parameters will no longer match the actual configuration and cause Dual check Safety to respond incorrectly. i) Dual check Safety is not capable of detecting errors in parameterization and programming made by the machine tool builder. The required level of safety can only be assured by thorough and careful acceptance. j) There is a parameter that MCC off test is not to be made in the self test mode at power-on as in the case of machine adjustment. This parameter is protected, only changed by authorized person. IF MCC off test is not conducted, MCC may not be off at stop response is measured. k) Safety machine position monitoring function does not apply to the spindle axis. l) During machine adjustment, an exact motion may be executed incorrectly until the safety functions setup correctly and confirm test is completely. m) Before the reference point return is performed and the MCC off test is performed, it may be dangerous because the correct operation does not be guaranteed. So, the careful operations are required when the machine is operated in the status that the protection door opens. n) The delay timer is prepared for the cross-checking of the safety related input/output signals. When the inconsistency exists between the signal from the 2 paths, system will recognize this failure, after this time is passed. The system will start the sequence of MCC shut-off, when this time is passed after the inconsistency is detected.
-9-
Page 18
1.OVERVIEW
1.4
B-64004EN/02
GENERAL INFORMATION The following requirements must be fulfilled for the Dual-Check System: All conditions of the certification report have to be respected. The procedures for the changes in the System (either HW or SW) should be referred to maintenance manual (B-63945EN). When safety related components are exchanged, confirmation test regarding safety functions can be performed according to Chapter 8. Programming in ladder logic should be referred to PMC programming manual (B-63983EN).
Training FANUC Training Center provides versatile training course for the person who is concerned with hardware installation, maintenance and operation. FANUC recommend studying and learning in the training center how efficiently operate FANUC products. There are 3 CNC training course. [ CNC ELEMENTARY COURSE ] Provides basics of CNC functions, operation and programming. The course is recommended before taking more specialized training courses to gain best effects. MAIN ITEMS OF TRAINING CNC functions Configuration of CNC Configuration and function of servo system Basic programming of CNC Part programming of milling machine Part programming of turning machine Introduction of Custom Macro function [ CNC MAINTENANCE COURSE ] To master maintenance technique that permits you to maintain and inspect CNC, also how to restore it promptly if a trouble should occur. MAIN ITEMS OF TRAINING Function and configuration of Power Unit Function and configuration of CNC system include AC servo and AC spindle Self-diagnosis function Interface between CNC and the machine tools Data saving and restoring operation Trouble shooting
- 10 -
Page 19
1.OVERVIEW
B-64004EN/02
[ CNC SE INTERFACE COURSE ] Training course offered to the engineers who design CNC machine tools or CNC application system for the first time. This course is also suitable for customers who provide to retrofitting, to develop an original CNC machine tools or new application of CNC. MAIN ITEMS OF TRAINING Configuration of CNC system Interface between CNC and machine tools Ladder programming of machine control sequence Setting of parameter related to machine Setting of parameter related to servo and spindle More information and course registration Yamanakako-mura, Yamanashi Prefecture : 401-0501, JAPAN Phone : 81-555-84-6030 Fax : 81-555-84-5540 Internet: www.fanuc.co.jp/eschool
- 11 -
Page 20
2.SYSTEM CONFIGURATION
2
B-64004EN/02
SYSTEM CONFIGURATION The dual check safety function has the following components. Applicable CNC FANUC Series 30i/300is/300i FANUC Series 31i/310is/310i A5 FANUC Series 31i/310is/310i FANUC Series 32i/320is/320i Number of controlled axes - Series 30i/300is/300i - Series 31i/310is/310i A5 - Series 31i/310is/310i - Series 32i/320is/320i
: 32 maximum : 20 maximum : 20 maximum : 9 maximum
Number of spindle controlled axes - Series 30i/300is/300i : 8 maximum - Series 31i/310is/310i A5 : 6 maximum - Series 31i/310is/310i : 6 maximum - Series 32i/320is/320i : 2 maximum Amplifier - α series servo amplifier - α series spindle amplifier - α series power supply module - αi series servo amplifier - βi series servo amplifier - αi series spindle amplifier - αi series power supply module Motor - α series servo motor - α series spindle motor - β series servo motor - αi series servo motor - αi series spindle motor - αis series servo motor - βis series servo motor - Lis series linear motor I/O - I/O unit (I/O Link)
- 12 -