ADVANCE PROGRAMMING 8

INTRODUCTION

This chapter explores some of the advanced programming capabilities of the M-Drive. These capabilities include two additional speed control formats, a form of position control and analog input/output. The five sections of this chapter are:

Format Definition

Direct Speed Control Format

Offset Speed Control Format

Additional Setpoint and Tachometer Possibilities Analog Input/Output (Optional)

FORMAT DEFINITION

Master and Follower speed control formats are both explained in chapter five. Two additional speed control formats are possible: Direct and Offset. The Direct speed control format is a method to command the M-Drive’s drive output to a specific percentage of the output voltage, ignoring the scaling and feedback conditions. Direct is typically used for system trouble-shooting.

The Offset speed control format adds two independent process variables, with the resulting sum used to pace the M-Drive. An example of the Offset control format using a follower system with a dancer POT is provided in this chapter.

SELECTING A SPEED CONTROL FORMAT

As indicated in chapter five, the Primary /Secondary discrete input selects between Master and Follower. Therefore, the question arises "How are the additional speed control formats invoked?". The answer is that the M-Drive must be told which format to use as Primary and which to use as Secondary. This is done by entering the number associated with each format (as listed below) into CP-61 for Primary and CP-62 for Secondary. A review of the programming examples in chapter five shows that the first step was in fact defining CP-61 and CP-62.

Number Speed Control Format

0 Direct

1 Master 2 Follower 3 Offset

Page 8-1

Page 78 read from a scan by OCR; it may hold reading errors

Note also that many of the scaling constants (CP-20 through CP-39) divide themselves into a primary and secondary group. Thus, the typical programming procedure is as follows:

1. Determine the speed control format for Primary Mode. Enter the appropriate number in CP-61.

Load system constants into the Primary Parameter Group.

* © BS

Repeat steps 1 through 3 above for Secondary Mode, using CP-62 and the Secondary Parameter Group.

DIRECT SPEED CONTROL FORMAT

When using the Direct Speed Control Format, the operator is able to control the output to the motor directly. When operating in Direct Format, the M-Drive ignores Accel, Decel and Feedback values, and immediately changes the output to the requested level entered into CP-6. The normal RUN/STOP logic is complied with. The example below illustrates Direct Format using Primary Mode (Secondary Mode would work as well). OBJECTIVE: Run the motor drive at 10% of full output. 1. Enter a 0 into CP-61 thereby designating Primary Mode as using Direct Format. 2. Enter 10 into CP-6 (Output Setpoint). 3. Place the M-Drive into the RUN state. RESULTS: The output should be at 10% of full output. The actual motor speed will depend on load characteristics, and will most likely not be 10% of the rated speed.

CAUTION: When operating in Direct Format, the current limit feedback is overridden by the M-Drive. Caution should be exercised to prevent equipment damage.

Page 8-2

Page 79 read from a scan by OCR; it may hold reading errors

OFFSET SPEED CONTROL FORMAT INTRODUCTION The Offset Speed Control format differs from Follower Format in two respects:

1. Offset provides for a second process variable in addition to the External Reference Frequency.

2. Offset allows the programmer to specify a speed difference (or offset) from the normally calculated Follower speed.

Consequently, the Offset Format motor speed is controlled by four variables: Ratio Setpoint, External Reference Frequency, Auxiliary Reference Frequency, and the user specified offset.

Appendix B lists the actual formulas used to calculate the motor speed for both Follower Format and Offset Format.

OFFSET FORMAT EXAMPLE

Figure 8-1 below illustrates a simple web process. Note that this application contains a loop which is controlled by a dancer POT. The example illustrates the use of a voltage controlled oscillator from the dancer POT to the Auxiliary Frequency Input. (The Analog Input could also be used, eliminating the VCO.) The frequency output of the oscillator is then applied to J3 pin 8 of the Follower M-Drive. Depending on this output value, the M- Drive adjusts the speed of the Follower Motor up or down as required to maintain the dancer POT position.

Follower J3-5 be ~ J3-2 < M-Drive } J3-5 Master 33-8 he M-Drive 6eT a c re > _, Dancer POT

Figure 8-1: Web Process illustrating Offset Format

Page 8-3

Page 80 read from a scan by OCR; it may hold reading errors

Recall that in this case two frequencies are used by the Follower M-Drive to determine the required follower Motor RPM: Line Speed (the external reference supplied by the Master Motor Feedback), and dancer POT position (the auxiliary reference supplied by the VCO). Also note that it is possible to control the gain on the POT displacement from the center Position and to bias or offset the result with the user specified constant. The Tach is explained later in this chapter.

This example uses Secondary Mode, but the Primary Mode would work as well.

ASSUMPTIONS Oo Nip rolls in Figure 8-1 are 1 foot in circumference oO Follower Motor is to draw the web at the same linear speed as the Master

(1800 feet per minute at 1800 RPM)

oo0oco

Both gears have 60 teeth Master is scaled as per chapter six (Page 6-5)

Desired Follower Setpoint is 1.000

VCO output range is 0 - 1000 Hz (500 Hz = dancer centered)

Full scale authority of the dancer POT is 10% of full speed (l.e., a 1000 Hz change in Aux Frequency should result in a 180 RPM change in the follower motor speed).

Ignoring the dancer pot, first program the M-Drive to follow at the proper line speed:

Control Parameter Entered

Parameter Title Data Remarks

CP-62 Secondary 3 Designates Secondary as Offset Format Scaling Format

CP-37 Secondary 1800 Maximum RPM of the shaft which the RPM Feedback feedback sensor is monitoring Maximum (normal operation)

CP-36 Secondary 1800 Maximum RPM of the shaft which the external RPM External reference sensor is monitoring Reference (normal operation) Maximum

CP-21 Secondary 1.000 Desired setpoint when the Ext. Ref. and Feedback Setpoint shafts are rotating at the speeds entered at Engineering CP-37 and CP-36 Units

CP-31 PPR 60 Number of teeth on the gear or number of lines Feedback on the encoder used for feedback

CP-30 PPR Ext 60 Number of teeth on the gear or number of lines Ref. on the encoder used for external reference

Page 8-4

Page 81 read from a scan by OCR; it may hold reading errors

The next step is to program the Auxiliary Reference Frequency input which represents the Dancer POT position (the VCO output). Two characteristics of this input must be controlled: Offset and Gain. The Offset determines which frequency will have no effect on the M-Drive’s speed (i.e., which position the dancer POT stabilizes at). The Gain determines how large an impact on the speed a given change in the Auxiliary Reference Frequency will have. As the Auxiliary Frequency source (in this case) is a VCO instead of a gear and sensor, it may be helpful to review the material on alternative frequency sources on Page 5-16.

Recall that the authority or gain of the dancer POT was assumed to be 10%. To accomplish this, entries are made indicating that the maximum expected Auxiliary Reference Frequency is 10,000 Hz when if fact it will never exceed the 1000 Hz output of the VCO. This provides the 10 to 1 reduction needed.

Control Parameter Entered

Parameter Title Data Remarks

CP-38 Secondary 1000 Ay RPM Auxil. Maximum

CP-32 PPR Aux. 600 These two entries imply the 10,000 Hz maximum Ref. as required

The last step is to enter an offset so that a centered POT (500 Hz) has no effect. This offset depends on the gain and is calculated using the formula:

- | AX * Bfmx * Pf C= Ramx * Pa

Where: = the required offset Rimx = the maximum RPM of the feedback shaft (CP-37) in the example. = PPR of the gear on the feedback shaft (CP-31) Ramx = the maximum RPM of the auxiliary shaft (CP-38) Pa = PPR of the gear on the auxiliary shaft (CP-32)

= the frequency at which the POT is to be neutralized (500 Hz)

A Refer to the programming conventions used when using Hz instead of RPM and PPR as discussed in Chapter 5.

Page 8-5

Page 82 read from a scan by OCR; it may hold reading errors

Replacing the variables with the example numbers, the Offset is then calculated. Note the minus sign in front of the right-hand expression.

- * 4 * C= 1000 * 600 C= -90 Control Parameter Entered Parameter Title Data Remarks CP-78 Secondary 90 Programming is complete Negative Offset

CP-77 and CP-78 work together in that CP-77 is a plus offset and CP-78 is a negative Offset. Note that only one of these parameters can have a non-zero value at a time. Whenever an entry is made at one location, the M-Drive automatically sets the other to zero. Codes CP-75 and CP-76 work the same but are in the Primary Parameter group.

Page 86

Page 83 read from a scan by OCR; it may hold reading errors

ADDITIONAL SETPOINT AND TACHOMETER POSSIBILITIES

SETPOINT POSSIBILITIES

The programmer is not prevented from designating the same format for both Primary and Secondary modes. E.g., CP-61 and CP-62 could both be loaded with a “2", giving two independent Follower formulas. In addition, both parameter groups could be loaded with the same system constants but four setpoints would be available.

TACHOMETER POSSIBILITIES

Chapter five assumed that the Master Format tach would always indicate the speed of the motor scaled in some appropriate engineering unit, and that the Follower Format tach would display a ratio between the two motors. Just as it is possible to use any combination of speed scaling formats and modes, it is possible to use any combination of tach scaling formats and modes. The most likely case is probably a Follower Speed control using a speed tach instead of a ratio tach.

ANALOG INPUT/OUTPUT PROGRAMMING (OPTIONAL)

ANALOG INPUT

The Analog Input can be used to replace any of the three frequency inputs or four setpoint values. To allocate the Analog Input to a specific function, enter the correct value for CP-84 according to the table below:

:

Analog Function

Not Used

External Reference Frequency Replacement Feedback Frequency Replacement

Offset Frequency Replacement

CP-1 (Setpoint 1) Replacement

CP-2 (Setpoint 2) Replacement

CP-3 (Setpoint 3) Replacement

CP-4 (Setpoint 4) Replacement

NOOhon- Oo

Table 8-1: CP-84 - Analog Input Allocation Codes

Page 8-7

Page 84 read from a scan by OCR; it may hold reading errors

When the Analog Input is allocated to replace one of the frequency inputs, the M-Drive automatically adjusts the corresponding PPR and RPM MAX codes for that frequency input. It sets the PPR value to 60 and RPM MAX values to 4095. For example, if the user enters a value of 1 for CP-84, the M-Drive then sets CP-30 to 60, CP-33 to 4095 and CP- 36 to 4095. This is equivalent to having an input frequency of 4095 HZ (4095 RPMs with a 60 tooth gear) when the Analog input is at its maximum level.

To complete the programming process, simply enter in the desired Engineering Unit values (at CP-20 through CP-23 and CP-75 through CP-78) that correspond to the maximum Analog Input value.

If an analog input level less than full scale is used, it is necessary to proportionally adjust the appropriate Engineering Unit parameter. For example, if a 0 to 5 VDC input corresponds to an Engineering Unit of 15 gallons/minute, the user enters an Engineering Unit value of 30 gallons/minute for the 0 to 10 VDC equivalent value.

The following examples illustrate the use of the Analog Input in the Master, Follower and Offset Modes.