What this file really is
The old site listed this file as a manual for the Contrex M-TRIM-2 and Fenner M-TRIM-2. The file is named as an M-TRIM-2 manual, but the document is the manual for the M-Drive motor speed drive, which mentions the M-Trim only in passing.
Filed with · 2 models
Also filed with these models on the old site
Summary
What is in it
Manual for the M-Drive, a digital motor speed drive in a 1/2 DIN enclosure that controls DC permanent magnet or field wound motors, alone or in a multi-motor system. It explains the Master and Follower formats, the run, jog and stop states, hardware configuration, installation and wiring, calibration, programming, operation, RS-422 serial communications, advanced programming and maintenance, with appendices and the warranty.
Its parts
- Introduction
- Configuration
- Installation
- Calibration
- Programming
- Operation
- Serial Comm
- Advanced Programming
- Maintenance
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Fenner manual for the M-Drive, a digital DC motor speed drive in a 1/2 DIN enclosure. It covers the drive formats and run/stop logic, installation and wiring, built-in diagnostics, symptom-based troubleshooting, spare parts and feedback sensors. The pages name the M-Drive throughout and mention the M-Trim only in passing; the text comes from a scan read by OCR.
- What it is
- M-Drive: digital speed drive for DC permanent magnet or field wound motors, 1/4 to 2 horsepower p. 1
- Input power
- 115 VAC or 230 VAC on the lowest 3 pins of J2 p. 21
- Enclosure
- 1/2 DIN vertical instrument enclosure for door mounting in a NEMA enclosure p. 16
- Communications
- RS-422 port for a host computer p. 1
- Feedback input
- Pulse train from a magnetic pickup, encoder, Hall effect quad sensor or proximity sensor; +12VDC for sensors up to 50 milliamps total p. 21
- Speed formats
- Four formats, including Master (keypad setpoint) and Follower (external reference times ratio) p. 3, 4
- Setpoints
- 4 preset setpoints p. 1
- Operating states
- RUN, R-STOP, F-STOP and JOG, set by J3 pins 14, 11, 13 and 16 p. 5, 6
- Environment
- 0-55 degrees C inside the enclosure; 0-90% humidity non-condensing p. 17
- Branch fuses
- Class G, 250V, 15 A, provided in the end application p. 15
- Spare fuses
- 6441-0200 Fuse 1A; 6441-0315 Fuse 15A (power fuses on the Power Drive Board) p. 99, 104
- Analog option
- 3200-1680 Analog Input/Output Option Board p. 104
- Magnetic pickups
- 5800-1410 SM3N; 5800-1412 SM3N-A; 6500-0038 SM5XP p. 110
- Brown-out codes
- ---1 AC power problem; ---2 noise; ---3 noise disrupted parameter RAM p. 103
What this manual walks you through
- Run/stop logic on J3 pins 14, 11, 13 and 16 p. 5, 6
- Mounting the drive in a panel cutout p. 16, 17
- Wiring input power and the feedback sensor p. 18, 21
- Power-up RAM and PROM tests p. 93
- Running the built-in display, keypad, input, output and serial tests p. 94, 95, 96, 97
- Troubleshooting a motor that will not stop, will not run or runs at the wrong speed p. 98, 99, 100, 101
- Fixing an incorrect tach reading p. 102
- Ordering spare parts p. 104
- Choosing ring kits, magnetic pickups and encoders for feedback p. 107, 110
Good to know
- Hazardous voltages are present; install only with qualified electrical maintenance personnel. p. 15
- Motor overload protection must be provided in the installation per the NEC. p. 15
- Do the configuration steps before mounting; the shunts and switches are harder to reach afterward. p. 16
- Keep AC power wiring (J2) apart from other wiring to avoid coupled noise. p. 18
- Suppress relay, contactor and solenoid coils in the same enclosure or on the same AC line with an RC network; 50 ohms and 0.1 microfarads give best results. p. 18
Questions this manual answers
What does ---1 or ---2 on the M-Drive display mean?
A brown-out watchdog problem: ---1 generally means an AC power problem and ---2 means electrical noise. p. 103
What voltage does the M-Drive run on?
Either 115 VAC or 230 VAC. p. 21
What size motors can the M-Drive control?
DC permanent magnet or field wound motors from 1/4 to 2 horsepower. p. 1
Contents
Chapters and sections
Each line opens the PDF at its page.
- M-Drive 1 Introduction1
- M-Drive 2 Configuration11
- M-Drive 3 Installation15
- M-Drive 4 Calibration35
- M-Drive 5 Programming39
- M-Drive 6 Operation55
- M-Drive 7 Serial Comm61
- M-Drive 8 Advanced Programming77
- M-Drive 9 Maintenance93
- M-Drive Appendix A107
- M-Drive Appendix B111
- M-Drive Appendix C113
- M-Drive Appendix D129
- M-Drive Appendix E131
- M-Drive Appendix F133
- M-Drive Appendix G135
- M-Drive Appendix H139
- M-Drive Appendix I141
- M-Drive Appendix J143
- M-Drive Warranty-Service147
The whole text · 20 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- M-Drive 1 Introduction1-10
- M-Drive 2 Configuration11-14
- M-Drive 3 Installation, pages 15 to 2415-24
- M-Drive 3 Installation, pages 25 to 3425-34
- M-Drive 4 Calibration35-38
- M-Drive 5 Programming, pages 39 to 4639-46
- M-Drive 5 Programming, pages 47 to 5447-54
- M-Drive 6 Operation55-60
- M-Drive 7 Serial Comm, pages 61 to 6861-68
- M-Drive 7 Serial Comm, pages 69 to 7669-76
- M-Drive 8 Advanced Programming, pages 77 to 8477-84
- M-Drive 8 Advanced Programming, pages 85 to 9285-92
- M-Drive 9 Maintenance93-106
- M-Drive Appendix A107-110
- Pages 111 to 119111-119
- Pages 120 to 128120-128
- Pages 129 to 132129-132
- Pages 133 to 138133-138
- Pages 139 to 142139-142
- Pages 143 to 148143-148
The file