The text of a manual · part 13 of 20
M-Drive: M-Drive 9 Maintenance
Pages 93 to 106 of 148, from M-Drive
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Fenner M-TRIM-2 and Contrex M-TRIM-2
Page 93
MAINTENANCE 9
INTRODUCTION
This chapter contains information designed to assist in diagnosing and solving M-Drive problems, and is divided into the following sections:
Power Up Describes the Power Up tests which occur during every M-Drive Power Up (Page 9-1)
Diagnostics Provides information for running the M-Drive Diagnostic Routines (Page 9-2)
Trouble-shooting Provides information to assist in solving typical M-Drive maintenance problems (9-6)
Spare Parts List Lists the available spare parts which can be ordered from the factory (Page 9-12)
EPROM Replacement Contains a procedure for replacing the EPROM (Page 9-12)
Restore Settings Provides a procedure which restores the M-Drive to the default factory settings (Page 9-13)
lf the information in this chapter does not solve your problem with the M-Drive, consult the factory.
The Fenner service number is 1-800-FIC-4411.
POWER UP
These routines are performed during every M-Drive Power Up.
1. RAM TEST
1. If RAM fails, a number is displayed (RAM Address = Displayed number + 49152) (C0000 HEX). Consult Factory. a) _ Test stops if a failure is detected. Press clear to continue test.
2. If RAM is good, exit is automatic (0.0.0.0 is displayed)
2. PROM TEST
1. Performs a checksum comparison. 2. If test fails, an error code is displayed: O.0.0.0. a) _ Test stops if a failure is detected. Press clear to continue test. 3. If PROM is good, exit is automatic. Page 9-1
Page 94
DIAGNOSTICS
The M-Drive contains a number of internal diagnostic routines designed to verify that the M-Drive is running correctly, and to identify specific M-Drive problems if they occur. The first set of diagnostic routines are initiated by a specific power up procedure, while the second set of diagnostics involve entering M-Drive input values, and verifying subsequent M-Drive frequency calculations.
CLEAR/8 POWER UP TESTS
Initiate Test
1. Remove power from the M-Drive. 2, While simultaneously pressing “Clear” and “4” on the Operator Keypad, apply power to the M-Drive. Response: “1” is shown in the lower display. If a “1” does not appear on the lower display, repeat step 2 using the “Clear” and “8” keys. 3. Press the UP or DOWN keys to select which of the seven tests to initiate. Each of the seven tests can be performed without repeating steps 1 and 2 above. 4. Press CODE SELECT key to exit diagnostics.
1, RAM TEST 1. Display “1” in the M-Drive lower display. 2. Press ENTER to start test. 3. If RAM fails, a number is displayed (RAM Address = Displayed number + 49152) (C0000 HEX). Consult Factory. a) Test stops if a failure is detected. Press clear to continue test. 4. If RAM is good exit is automatic (0.0.0.0 is displayed).
Page 9-2
Page 95
2. DISPLAY TEST
1. Display "2" in the M-Drive lower display.
2. Press ENTER to start test.
3. M-Drive displays the following: 000000000 14141141411 222222222 333333333 444444444 555555555 666666666 777777777 888888888
999999999
The following LEDs are illuminated in order: Setpoint, Tach, Code Select, Run, Jog, Preset Limit Alarm, Dev Alarm.
0.0.0.0 is then displayed Display goes blank.
(Incorrect Display indicates failure)
3. KEYPAD TEST 1. Display “3" in the M-Drive lower display. 2. Press ENTER to start test. 3. Press each Operator Keypad Key. The M-Drive displays a number according to the key pressed:
Press Display Press Display - - SETSPEED 10 TACH 11 ENTER 12 13 14 Code Select 15 Clear
OOnNOOAWNY=AO OOANDOAADNH=O°
4. Press CLEAR to exit test.
Page 9-3
Page 96
4. INPUT TEST 1. Display "4" in the M-Drive lower display. 2. Press ENTER to start test.
3. Close input switches. The M-Drive displays a number according to the input pressed. Input Closure Display In losure Display R-STOP (J3-11) 1 Ramp Dis = (J4-7) 9 RUN (J3-13) 2 P 1/2 (J4-9) 10 F-STOP (J3-14) 3 S$ 3/4 (J4-10) 11 JOG (J3-16) 4 Local/Rem (J4-12) 12 Key Lock = (J4-1) 5 Remt UP (J4-13) 13 Pri/Sec (J4-3) 6 Remt DN (J4-15) 14 Spare (J4-4) 7 Loop (J4-6) 8
4. Press CLEAR to exit test.
5. OUTPUT TEST 1. Display "5" in the M-Drive lower display. 2. Press ENTER to start test.
3. Press keys 1 - 7 to enable outputs. Pull-up resistors and meter or LED is required.
Key Outputs Key Qutput |
1 Zero Speed 4 Dev 1 2 HighAlarm 5 Dev 2 3 Lo Alarm
4. Press CLEAR to exit test.
6. SERIAL INPUT TEST
Prerequisites: Jump J1 Pin 4 to J1 Pin 2 and Jump J1 Pin 5 to J1 Pin 3
Display “6" in the M-Drive lower display. Press ENTER to start test.
M-Drive displays 300 if 300 baud failure. M-Drive displays 2400 if 2400 baud failure. M-Drive displays 9600 if 9600 baud failure. 4. Exit is automatic (0.0.0.0 is displayed)
oOn>
Page 9-4
Page 97
7. CODE # TEST 1. Display "7" in the M-Drive lower display. 2. Press ENTER to start test. 3. M-Drive displays date code of software. 4. Press CLEAR to exit test.
VERIFYING M-DRIVE FREQUENCY CALCULATIONS
1, Frequency input Test
1. Connect VCO frequency into: a) External Reference Frequency Input b) Feedback Frequency Input c) Offset Frequency Input 2. Verify proper input calculations by checking the following M-Drive Monitor Variables: a) MV-41 (External Reference Frequency) b) MV-42 (Offset Frequency) C) MV-43 (Feedback Frequency).
2._Driv Ti 1. Set CP-61 to 0.
2. Set Code 6 variables from 0 to +100 3. Check Drive for correct output.
3. Run Motor Test 1. Test M-Drive running a Motor at 1800 RPM.
Page 9-5
Page 98
TROUBLE-SHOOTING INTRODUCTION
The trouble-shooting section is organized using a symptom/ response format. On the left side of the page are symptoms, conditions or instructions, and on the right side of the page are cross-references indicating an additional routine to perform.
In general, identify which category from section 1 (Symptoms) applies for your problem, and then follow the cross-referenced routine on the following pages to identify the probable cause (and solution) for the M-Drive malfunction.
NOTE: IAW indicates “In Accordance With".
WARNING
Hazardous voltages are present during certain procedures in this chapter. Therefore, these procedures should only be performed by qualified electrical maintenance personnel.
1. Symptoms
1.1 _M-Drive processor operates incorrectly Perform Routine # 1.2 Motor does not stop 2.
1.3 Motor does not run 3.
1.4 Motor runs at wrong speed 4.
1.5 Motor runs at correct speed but does not run fast enough 5.
1.6 Motor runs at correct speed but does not run slow enough 6.
1.7 Motor runs unstable 7.
1.8 Tach reads incorrectly 8.
1.9 Display shows ---1 or ---2 10.
Page 9-6
Page 99
2. Motor Does Not Stop 2.1 Check MV-53 (RUN/STOP STATE) If MV-53 = 128, then 2.2 If MV-53 = 64, then 2.2 If MV-53 = 32, then J3 pin 13 is (at least momentarily) shorted to common If MV-53 = 1, then J3 pin 16 is shorted to common
2.2 Measure voltage of J2-Pin 4 with respect to J2-Pin 3. If voltage = zero Verify motor armature wiring. lf voltage not = zero Consult MV-54 and Page C-9 to determine if Ramp is disabled. If true, J4-Pin 7 is shorted to common. if false, call factory.
3. Motor Does Not Run 3.1 Check MV-53 If MV-53 = 128, then J3 Pin 14 is not shorted to common If MV-53 = 64, then J3 Pin 11 is (at least momentarily) not shorted to common If MV-53 = 32, then check fuses on Power Drive Board * If MV-53 = 1, then check fuses on Power Drive Board
4. Motor Runs at Wrong Speed 4.1 Determine M-Drive control format if Master, then 4.2 If Follower, then 4.3 If Offset, then 4.4 if Jog, then 4.5 lf Direct, then 4.6 4.2 Master Control Format
Check MV-53
If MV-53 not = 32, then 9.1 Check MV-50 (Active Format)
If MV-50 not = 1, then 9.2 Check Setpoint
If setpoint incorrect, then enter correct Setpoint and exit Trouble-shooting outline. Check MV-45 (Scaled Reference)
If MV-45 incorrect, then 9.3
IF MV-45 correct, then 4.7
* In addition to the logic fuse on the rear of the M-Drive, there are two power fuses located on the M-Drive Power Drive Board. These are used to protect the power drive portion of the M-Drive. Remove the rear plate and pull out the Power Drive Board to replace these fuses (Fenner Part No 6441-0315).
Page 9-7
Page 100
4.3 Follower Control Format
Check MV-53 If MV-53 not = 32, then 9.1 Check MV-50 If MV-50 not = 2, then 9.2 Check Setpoint if setpoint incorrect, then enter correct setpoint and exit Trouble-shooting outline. Check MV-45 (Scaled Reference) If MV-45 incorrect, then 9.3 IF MV-45 correct, then 4.7 4.4 Offset Control Format Check MV-53 If MV-53 not = 32, then 9.1 Check MV-50 If MV-50 not = 3, then 9.2 Check Setpoint If setpoint incorrect, then enter correct setpoint and exit Trouble-shooting outline. Check MV-45 (Scaled Reference) If MV-45 incorrect, then 9.3 If MV-45 correct, then 4.7
4.5 Jog Control Format Check MV-53 If MV-53 not = 1, then 9.1 Check CP-5 (Jog Setpoint) lf CP-5 incorrect, then enter correct setpoint and exit Trouble-shooting outline.
Check MV-45 (Scaled Reference) If MV-45 incorrect, then 9.3 IF MV-45 correct, then 4.7
4.6 Direct Control Format
Check MV-53
If MV-53 not = 32, then 9.1 Check MV-50
If MV-50 not = QO, then 9.2
Check CP-6 (Direct Setpoint) If CP-6 incorrect, then enter correct setpoint and exit Trouble-shooting outline. lf CP-6 correct, then 4.12
4.7 Check MV-46 (Ramped Reference) if MV-46 correct, then 4.8 If MV-46 incorrect, then consult Table 9-1 to determine if Ramp is disabled, else Ramp is in Progress. Page 3-8
Page 101
4.8 Consult Table 8-1 for Open/Closed Loop status if Closed Loop, then 4.9 lf Open Loop, then J4-Pin 6 is shorted to common
4.9 Check MV-68 (Trim Authority) Most systems should be able to operate with trim authorities as low as 20%. If this is not true, either the system (drive) is nonlinear, under powered, or improperly scaled. lf CP-68 < 20, then set CP-68 to 20 or higher lf CP-68 > 20, then 4.10
4.10 Check CP-66 (Reset) This value should be the smallest reset possible consistent with stable operation. 2000 - 4000 is reasonable.
4.12 Check Motor Armature and field connections
5. Motor Runs at Correct Speed but does not Run Fast Enough 5.1 Check CP-11 (Maximum RPM) 9.2 Verify current limit calibrations IAW Page 4-1.
6. Motor Runs at Correct Speed but does not Run Slow Enough 6.1 Check CP-10 (Minimum RPM)
7. Motor Runs Unstable 7.1 Enter 100 at CP-68, and tune the M-Drive [AW Page 5-12.
Page 9-9
Page 102
8. Tach Reads Incorrectly 8.1 Check MV-54 and Table 9-1 to insure M-Drive is operating Closed Loop. 8.2 Check Mv-44 If MvV-44 is not near zero, then motor is not running at the correct speed 4. 8.3 Verify Mv-54 is correct using the appropriate formula from 9.3 9.3
8.4 Check MV-54 and Table 9-1 toe determine if M-Drive is in Primary or Secondary Moda. If Primary Mode, Check MV~63. If M-Drive in Primary Mode and MV-63=1, then calculate tach indication: Mv-40 = (CP-22 * Mv-43 * 60)/(CP-34 * CP-31)
If M-Drive in Primary Mode and MV-63=2, then calculate tach indication: Mv-40 = (CP-22 * MV-43 * CP-33 * CP-30) (MV-41 * CP-34 * CP31)
If Secondary Mode, Check MV-64. If M-Drive in Secondary Mode and MV-64=1, then calculate tach indication: MVv-40 = (CP-23 * MV-43 * 60)/(CP-37 * CP-31)
If M-Drive in Secondary Mode and MV-64=2, then calculate tach indication: Mv-40 = (CP-23 * MV~43 * CP-36 * CP-30) (MV-41 * CP-37 * CP-31)
Page 9-10
Page 103
9. System Checks 9.1 RUN/STOP LOGIC lf MV-53 = 128, then J3-Pin 14 is not shorted to common. If MV-53 = 64, then J3-Pin 11 was not (at least temporarily) shorted to common. If MV-53 = 32, then J3-Pin 13 was (at least temporarily) shorted to common. IF MV-53 = 1, then J3-Pin 16 is shorted to common.
9.2 Format Consult MV-54 and Table 7-1 to verify Primary/Secondary mode. If Primary Mode, enter proper format into CP-61. If Secondary Mode, enter proper format in CP-62.
9.3 Scaled Reference Determine Mode and Format, then calculate MV-45 per the correct equation.
MODE FORMAT EQUATION
PRI 0 MV-45=0
PRI 1 MV-45 = (SP*CP34*CP31)/(CP20 *60)
PRI 2 MV-45 = (SP*MV41*CP34*CP31) (CP20*CP33*CP-30)
PRI 3 Mv-45= (SP*MV41*CP34*CP31) (CP20*CP33*CP-30) +
(MV42*CP34*CP31)/(CP35*CP32) +
(CP75 - CP76).
SEC 0 MV-45=0
SEC 1 MV-45 = (SP*CP37*CP31)/(CP21 *60)
SEC 2 MV-45= (SP*MV41*CP37*CP: (CP21*CP36*CP-30)
SEC 3 MV-45= (SP*MV41*CP37*CP31)
(CP21*CP36*CP-30) + (MV42*CP37*CP31)/(CP38*CP32) + (CP77 - CP78).
10. Brown Out Watch Dog (---1, ---2 or ---3 displayed)
A display reading of ---1, ---2 or ---3 indicates an M-Drive environment problem; i-.e., electrical noise severe enough to disrupt the microprocessor or a temporary interruption of AC power requirements. Generally, ---1 indicates an AC power problem, ---2 indicates noise, and ---3 indicates noise has disrupted the parameter RAM. If a ---2 or --3 appears, the programming Control Parameters should be verified and a Clear 7 procedure performed (see Page 9-13).
Page 9-11
Page 104
SPARE PARTS LIST
Part Number Description
6441-0200 Fuse 1A
6441-0315 Fuse 15A
6340-0021 Shunt Jumper
6310-0226 7 Position Terminal Connector (Power Drive Board)
6310-0224 16 Position Terminal Connector (CPU Board)
6310-0227 16 Position Terminal Connector (Drive Board)
6310-0228 18 Position Terminal Connector (CPU Board)
3200-1680 Analog Input/Output Option Board
Call Factory PROM Number
Page 9-12
Page 105
EPROM LOCATION
It is possible that the EPROM may be replaced at the customer’s location. Figure 9-1 below illustrates the location of this EPROM.
(TOP)
a oT * . tT
EPROM Chip
Figure 9-1: EPROM Location
RESTORE SETTINGS
CAUTION
This procedure restores the M-Drive to the factory default settings. Any User-entered parameters or programming will be erased.
1. Remove power from the M-Drive.
2. While pressing "Clear* and "7" on the Operator Keypad, apply power to the M-Drive.
Response: The M-Drive restores the factory default settings, and then performs the Power Up routine described on Page 9-1,
Page 9-13
Page 106
NOTES
Page 9-14