CONFIGURATION 2

INTRODUCTION

This chapter contains the information required to hardware configure the M-Drive for purposes of electrical compatibility. The procedures within this chapter should be completed prior to installing the M-Drive. Note that these procedures do not require power to complete.

Before proceeding with the configuration procedure, read the information below to determine if the factory default configuration is appropriate for your application. In most cases, it will not be necessary to reconfigure the M-Drive.

This chapter is divided into 3 sections: Frequency Inputs, Analog Input/Output (Optional), and Power Voltage Select. Figure 2-1 below illustrates the location for the CPU board and the Power Drive board.

Power CPU Supply _ - " Board Board pa aaa

Figure 2-1: M-Drive Board Location (Rear View)

Page 2-1

Page 12 read from a scan by OCR; it may hold reading errors

FREQUENCY INPUTS

The Frequency Input select jumpers are located on the M-Drive CPU board. To gain access to this board, remove (pull off) the screw headers from the rear terminal connecters. Next, remove the six mounting screws and backplate. The CPU board is the right-hand board when viewing the M-Drive from the rear (Figure 2-1). Pull this board out approximately 1 inch to expose the Frequency Input select jumpers on the top component side of the board.

Note: Ensure that the CPU board is properly seated into the back pin connections when reassembling the M-Drive.

The Frequency Input select jumper configures the External Reference, Feedback and Auxiliary Frequency Inputs for either zero crossing (magnetic pickup) or open-collector (proximity and encoder) signal compatibility. Table 2-1 below illustrates which jumpers are used to configure these three inputs. For example, a jumper shunted between pins 7 and 8 configures the Feedback Input for Zero Crossing.

Open Collector Zero Crossing (Default) External Reference 1-2 3-4 Feedback 5 = 6 7-8 Auxiliary Input 9 - 10 11 - 12

Table 2-1: Frequency Input Selections

Figure 2-2 below illustrates 2 possible configurations for the Frequency Input select jumpers: Figure 2-2a illustrates all three inputs configured for Open-Collectors, while Figure 2-2b illustrates all three inputs configured for Zero Crossing (Default).

J4 J4 mn ‘ee 1 re) ° 2 1 ro) oO 2 3 re) ° 4 3 re) re) 4 5 ?) re) 6 5 ° ° 6 7 ro) oO 8 7 ° re] 8 9 re) oO 10 9 re) °o 10 11 re) ° 12 11 e) re) 12 iin i

J2 A: Open-Collector J2 B: Zero Crossing

(Default)

Figure 2-2: Frequency Input Options

Page 2-2

Page 13 read from a scan by OCR; it may hold reading errors

ANALOG INPUT/OUTPUT (OPTIONAL)

The Analog Input/Output Option board mounts on the lower rear component side of the CPU board. To field install this option board, first remove the screw barrier connectors on the rear of the M-Drive. Next, remove the six mounting screws and backplate. The CPU board is the right-hand board when viewing the M-Drive from the rear (Figure 2-1). Pull this board out to expose the two 12-position male connectors used to mount the Analog Input/Output Option board (lower rear component side of CPU board). Plug the two 12-position female connectors on the solder side of the Analog Input/Output Option board into the male connectors of the CPU board. A nylon standoff is provided for mechanically mounting the option board. The option board should be mounted with the selector shunts facing the rear of the CPU board.

Note: Ensure that the CPU board is properly seated into the back pin connections when reassembling the M-Drive.

The Analog Input/Output select jumper configures the analog input and output for either a 10 volt DC level or a 4 to 20 mA current level. Table 2-2 below illustrates which jumpers are used to configure the input and output. For example, a jumper shunted between pins 9 and 10 configures the analog output for + 10 VDC. *

0 to 10 vbC 4 to 20 mA (Default) 1 - 2 and 3 - 4 and Analog Input 5-6 7-8 * Analog Output 9 - 10 11 - 12

Table 2-2 Analog Input/Output Selections

* Note: The analog output level will range from -10 volts to + 10 volts when patched to variables with positive and negative values. It will range from 0 to +10 volts for variables with positive values only.

Page 2-3

Page 14 read from a scan by OCR; it may hold reading errors

Figure 2-3 below illustrates 2 possible configurations for the Analog Input/Output select jumpers. Figure 2-3a illustrates both the input and output configured for 0-10 VDC (default). Figure 2-3b illustrates both the input and output configured for 4-20 mA.

1 °o ° 2 1 ° °o 2 3 °o ° 4 3 ° ° 4 Analog Input 5 ° ra] 6 5 o re) 6 7 Oo ° 8 7 °o ° 8 9 ° °o 10 9 re) oO 10 Analog Output 11 ° ° 12 11 °o °o 12 A: 0 to 10 VDC B: 4 to 20 mA (Default)

Figure 2-3: Analog Input/Output Options

CAUTION

To prevent possible equipment damage, the upper two shunts configuring the Analog Input must always move as a pair. That is, the Analog Input shunts must connect either positions 1-2 and 5-6 or connect positions 3-4 and 7-8.

POWER VOLTAGE SELECT

The Power Voltage Select switch is located on the bottom of the Power Drive board, just above the fuse.

This switch selects for either 115 VAC (Default) or 230 VAC power.

The switch is clearly marked for the two available positions.