Page 129
APPENDIX D - USER’S ACTUAL CODE RECORD D
Column 5 (User Setting) is provided for recording the actual value entered for each Code Type.
CODE USER
TYPE DESCRIPTION MIN MAX SETTING UNITS 01-CP Primary Setpoint 1 0000 9999 ENG. 02-CP Primary Setpoint 2 0000 9999 ee ENG, 03-CP Secondary Setpoint 1 0000 9999 _ ENG. 04-CP Secondary Setpoint 2 0000 9939 _ ENG. 05-CP Jog Setpoint 0000 9999 _ RPM 06-CP Output Setpoint -100 +100 % 10-CP Minimum Limit 0000 9999 RPM 11-CP Maximum Limit 0000 9999 RPM 12-CP Low Alarm 0000 9999 RPM 13-CP High Alarm 0000 9999 RPM 14-CP Error Alarm 1 0000 9999 _ RPM 15-CP Error Alarm 2 0000 9999 _ RPM 16-CP Acceleration Time 000.0 600.0 SEC 17-CP Deceleration Time 000.0 600.0 SEC 18-CP Lag Pulse Limit 0 9999 __ PULSES 19-CP Lead Pulse Limit 0 9999 PULSES 20-CP Eng. Units-Pri.Sp. 0.000 9999 ENG. 21-CP Eng. Units-Sec.Sp. 0.000 9999 ENG. 22-CP Eng. Units-Pri.Dsp. 0.000 9999 ENG. 23-CP Eng. Units-Sec.Dsp. 0.000 9999 ENG. 29-CP Recovery Multiplier 0 100 -
30-CP PPR-Ext. Reference 1 9999 PPR 31-CP PPR-Feedback 1 9999 PPR 32-CP PPR-Auxiliary 1 9999 PPR 33-CP RPM-Ref.-Primary Max 1 9999 RPM 34-CP RPM-Fdbk.-Primary Max 1 9999 RPM 35-CP RPM-Aux.-Primary Max 1 9999 RPM 36-CP RPM-Ref.-Secondary Max 1 9999 RPM 37-CP RPM-Fdbk.-Secondary Max 1 9999 RPM 38-CP RPM-Aux.-Secondary Max 1 9999 RPM 60-CP Current Limit Response 0 50 CODED 61-CP Scaling Mode-Pri. 0 3 CODED 62-CP Scaling Mode-Sec. ft) 3 CODED 63-CP Display Mode-Pri. 1 2 CODED 64-CP Display Mode-Sec. 1 2 CODED 65-CP Gain 0 9999 -
66-CP Reset 0 9999 -
67-CP Rate 0 9999 -
68-CP Trim Authority 0 100 % 69-CP Rate Threshold 1) 100 HZ 70-CP Device Address 1 32 -
71-CP Baud Rate 1 6 CODED 72-CP Character Format 1 3 CODED 73-CP Control Mask 0 255 CODED 74-CP Zero Speed Logic 0 1 CODED 75-CP Positive Offset, Pri. 0 9999 HZ 76-CP Negative Offset, Pri. 0 9999 HZ 77-CP Positive Offset, Sec. 0 9999 HZ
Page 130
USER
CODE-TYPE DESCRIPTION MIN MAX SETTING UNITS 78-CP Negative Offset, Sec. 0 9999 HZ 79-CP Setpoint Mask 0 2 CODED 80-CP Analog Output Allocat. 0 99 CODED 81-CP Analog Output Range 0 9999 CODED 82-CP Analog Output Zero 0 2048 CODED 83-CP Analog Output Span 2048 4095 CODED 84-CP Analog Input Allocat. 0 7 CODED 85-CP Analog Input Zero 0 2048 CODED 86-CP Analog Input Span 2048 4095 CODED
Page D-2
Page 131
APPENDIX E: CODE LIST QUICK REFERENCE E
CODE DESCRIPTION MIN MAX DEFAULT UNITS TYPE
01-CP Primary Setpoint 1 0000 9999 0000 ENG. 02-CP Primary Setpoint 2 0000 9999 0000 ENG. 03-CP Secondary Setpoint 1 0000 9999 0000 ENG. 04-CP Secondary Setpoint 2 0000 9999 0000 ENG. 05-CP Jog Setpoint 0000 9999 50 RPM 06-CP Output Setpoint, 100 +100 0 % 10-CP Minimum Limit 0000 9999 0000 RPM 11-CP Maximum Limit 0000 9999 2000 RPM 12-CP Low Alarm 0000 9999 0000 RPM 13-CP High Alarm 0000 9999 2000 RPM 14-CP Error Alarm 1 0000 9999 2000 RPM 15-CP Error Alarm 2 0000 9999 2000 RPM 16-CP Acceleration Time 000.0 600.0 5.0 SEC 17-CP Deceleration Time 000.0 600.0 5.0 SEC 18-CP Lag Pulse Limit 0 9999 0 PULSES 19-CP Lead Pulse Limit 0 9999 0 PULSES 20-CP Eng. Units-Pri.Sp. 0.000 9999 2000 ENG. 21-CP Eng. Units-Sec.Sp. 0.000 9999 1.000 ENG. 22-CP Eng. Units-Pri.Dsp. 0.000 9999 2000 ENG. 23-CP Eng. Units-Sec.Dsp. 0.000 9999 1.000 ENG. 29-CP Recovery Multiplier 0 100 0 _ - 30-CP PPR-Ext. Reference 1 9999 60 PPR 31-CP PPR-Feedback 1 9999 60 PPR 32-CP PPR-Auxiliary 1 9999 60 PPR 33-CP RPM-Ref.-Primary Max 1 9999 2000 RPM 34-CP RPM-Fdbk.-Primary Max 1 9999 2000 RPM 35-CP RPM-Aux.-Primary Max 1 9999 2000 RPM 36-CP RPM-Retf.-Secondary Max 1 9999 2000 RPM 37-CP RPM-Fdbk.-Secondary Max 1 9999 2000 RPM 38-CP RPM-Aux.-Secondary Max 1 9999 2000 RPM 40-MV Tach 0 9999, ENG. 41-MV External Reference 0 9999, HZ 42-MV Auxiliary Input 0 9999, HZ 43-MV Feedback ) 9999, HZ 44-MV Deviation 0 9999, HZ 45-MV Scaled Reference 0 9999, HZ 46-MV Ramped Reference 0 9999, HZ 47-MV Output -100 +100, % 48-MV Trim Output, 4096 +4096, BITS 49-MV Pulse Error Count -9999 9999, PULSES 50-MV Active Mode 0 3, CODED 51-MV Entry Errors 0 5, CODED 52-MV Alarm Status 0 6, CODED 53-MV Control State 8) 128, CODED 54-MV Control Mode 0 255 _ CODED 55-MV A/D Input 0 4095 _ CODED 56-MV A/D Input-Adjusted 0 4095, CODED 57-MV Power Line Failure 0 9999, _ COUNTS 58-MV Communications Error 0 63, CODED 59-MV Frequency Overflow 0 9999 _ COUNTS 60-CP Current Limit Response 0 50 20 CODED
Page E-1
Page 132
CODE DESCRIPTION MIN MAX DEFAULT UNITS TYPE
61-CP Scaling Mode-Pri. 0 3 1 CODED 62-CP Scaling Mode-Sec. 0 3 2 CODED 63-CP Display Mode-Pri. 1 2 1 CODED 64-CP Display Mode-Sec. 1 2 2 CODED 65-CP Gain 0 9999 9000, 66-CP Reset 0 9999 2000, 67-CP Rate 0 9999 9000, 68-CP Trim Authority 1) 100 100 % 69-CP Rate Threshold 1) 100 10 HZ 70-CP Device Address 1 32 1, 71-CP Baud Rate 1 6 6 CODED 72-CP Character Format 1 3 2 CODED 73-CP Control Mask 0 255 0 CODED 74-CP Zero Speed Logic 0 1 0 CODED 75-CP Positive Offset, Pri. 0 9999 0 HZ 76-CP Negative Offset, Pri. 0 9999 0 HZ 77-CP Positive Offset, Sec. 0 9999 ) HZ 78-CP Negative Offset, Sec. 0 9999 0 HZ 79-CP Setpoint Mask 0 2 2 CODED 80-CP Analog Output Alloc. 0 99 98 CODED 81-CP Analog Output Range 0 9999 2000 CODED 82-CP Analog Output Zero 0 2048 998 CODED 83-CP Analog Output Span 2048 4095 3906 CODED 84-CP Analog input Allocat. 0 7 0 CODED 85-CP Analog Input Zero 0 2048 0 BITS 86-CP Analog Input Span 2048 4095 3900 BITS 99-MV Software Code Rev were wee wee REV 00-MV Software PartNumber 9 ws-w--= were eee NUMBER
Page E-2