Page 21

Valve terminals CPV, Compact Performance Key features – Pneumatic components Pneumatic connection The working lines are located directly in the valve slices. Threaded connectors and Quick Star push-in fittings (QS) are available for different tubing sizes. The supply ports are located in the end plates or in the pneumatic multiple connector plate. Push-in fittings are available fully assembled. The following working lines can be selected: Large push-in connectors: code A

Small push-in connectors: code B Threaded connectors: code C Connection sizes for the threaded and QS push-in fittings can be found in the table below.

the valve ports. The pneumatic multiple connector plate enables different mounting options from wall mounting to direct passage through a cabinet wall.

Easy-to-service and flexible connection technology thanks to the following: Common connection via the pneumatic multiple connector plate with all connections on one side

The valve terminal can be assembled/disassembled using only four screws, whereby the pneumatics remain fully connected Quick assembly/disassembly No errors when recommissioning as a result of incorrect connection of tubing

Pneumatic multiple connector plate One-piece “connection plates” that contain both working lines and supply ports can be combined with a pneu­ matic multiple connector plate. This enables the valve terminal as a pneu­ matic “function” to be separated from

CPV valve terminal

Pneumatic multiple connector plate 4

1

12/14 4

1

2

3/5

82/84

11

2

11

Connection sizes Connection to ISO 5599

CPV10

CPV14

CPV18

Comment

1/11

Working air

G1/8

G1/4

G3/8

2/4

Working line

M7 (QS6/QS4)

G1/8 (QS8/QS6)

G1/4 (QS10/QS8)

3/5

Exhaust air port

12/14

Pilot air supply port

G3/8 G1/4 M5

G1/2 G3/8 G1/8

G1/2 G1/2 G1/4

82/84

Pilot exhaust air port

M5 M7 (M5)1)

G1/8 G1/8

G1/4 G1/4

Fitting in end plate or pneumatic multiple connector plate Connection in valve slice, connection for push-in fitting in brackets Via right-hand/left-hand end plate Pneumatic multiple connector plate Fitting in end plate or pneumatic multiple connector plate Via right-hand/left-hand end plate Pneumatic multiple connector plate

1)

With flanged pneumatic multiple connector plate

2018/09 – Subject to change

è Internet: www.festo.com/catalogue/...

21

Page 22

Valve terminals CPV, Compact Performance Key features – Pneumatic components Pneumatic connection: fitting set for compressed air supply Code for Port compressed air supply

Designation

Without pneumatic multiple connector plate U, V 82/84 Silencer 3/5 Silencer 1 Push-in fitting

Size 14 QS8 Type

Size 18 QS10 Type

AMTE-M-LH-M5 U-3/8-B QS-1/8-8-I

U-1/8-B U-1/2-B QS-1/4-10-I

U-1/4-B U-1/2-B QS-3/8-12-I

W, X

82/84 3/5 1 12/14

Silencer Silencer Push-in fitting Push-in fitting

AMTE-M-LH-M5 U-3/8-B QS-1/8-8-I QSM-M5-6-I

U-1/8-B U-1/2-B QS-1/4-10-I QS-1/8-8-I

U-1/4-B U-1/2-B QS-3/8-12-I QS-1/4-10-I

Y

82/84 on right 82/84 on left 3/5 on right 3/5 on left 1/11 on left

Silencer Blanking plug Silencer Blanking plug Push-in fitting

AMTE-M-LH-M5 B-M5 U-3/8-B B-3/8 QS-1/8-8-I

U-1/8-B B-1/8 U-1/2-B B-1/2 QS-1/4-10-I

U-1/4-B B-1/4 U-1/2-B B-1/2 QS-3/8-12-I

Z

82/84 on right 82/84 on left 3/5 on right 3/5 on left 12/14 on right 12/14 on left 1/11

Silencer Blanking plug Silencer Blanking plug Push-in fitting Blanking plug Push-in fitting

AMTE-M-LH-M5 B-M5 U-3/8-B B-3/8 QSM-M5-6-I B-M5 QS-1/8-8-I

U-1/8-B B-1/8 U-1/2-B B-1/2 QS-1/8-8-I B-1/8 QS-1/4-10-I

U-1/4-B B-1/4 U-1/2-B B-1/2 QS-1/4-10-I B-1/4 QS-3/8-12-I

UC-M7 B-M7 U-1/4-B QS-1/8-8-I B-1/8

U-1/8-B B-1/8 U-3/8-B QS-1/4-10-I B-1/4

U-1/4-B B-1/4 U-1/2-B QS-3/8-12-I B-3/8

UC-M7 U-1/4-B QSM-M7-6-I QS-1/8-8-I

U-1/8-B U-3/8-B QS-1/8-8-I QS-1/4-10-I

U-1/4-B U-1/2-B QS-1/4-10-I QS-3/8-12-I

AMTE-M-LH-M5 B-M5 U-1/4-B QS-1/8-8-I B-1/8

U-1/8-B B-1/8 U-3/8-B QS-1/4-10-I B-1/4

U-1/4-B B-1/4 U-1/2-B QS-3/8-12-I B-3/8

AMTE-M-LH-M5 U-1/4-B QSM-M5-6-I QS-1/8-8-I

U-1/8-B U-3/8-B QS-1/8-8-I QS-1/4-10-I

U-1/4-B U-1/2-B QS-1/4-10-I QS-3/8-12-I

With pneumatic multiple connector plate; code M Y 82/84 Silencer 12/14 Blanking plug 3/5 Silencer 1/11 on left Push-in fitting 11 on right Blanking plug Z

82/84 3/5 12/14 1/11 on left

Silencer Silencer Push-in fitting Push-in fitting

With pneumatic multiple connector plate; code P, GQC Y 82/84 Silencer 12/14 Blanking plug 3/5 Silencer 1/11 on left Push-in fitting 11 on right Blanking plug Z

22

Size 10 QS6 Type

82/84 3/5 12/14 1/11 on left

Silencer Silencer Push-in fitting Push-in fitting

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/09

Page 23

Valve terminals CPV, Compact Performance Key features – Pneumatic components Pneumatic connection: fitting set for compressed air supply Code for Port compressed air supply

Designation

Size 10 QS6 Type

Size 14 QS8 Type

Size 18 QS10 Type

B-M5 B-3/8 QS-1/8-8-I

B-1/8 B-1/2 QS-1/4-10-I

B-1/4 B-1/2 QS-3/8-12-I

Blanking plug Blanking plug Push-in fitting Push-in fitting

B-M5 B-3/8 QS-1/8-8-I QSM-M5-6-I

B-1/8 B-1/2 QS-1/4-10-I QS-1/8-8-I

B-1/4 B-1/2 QS-3/8-12-I QS-1/4-10-I

With pneumatic multiple connector plate; code M E, F, H 82/84 Blanking plug 3/5 Blanking plug 1/11 Push-in fitting 12/14 Push-in fitting

B-M7 B-1/4 QS-1/8-8-I QSM-M7-6-I

B-1/8 B-3/8 QS-1/4-10-I QS-1/8-8-I

B-1/4 B-1/2 QS-3/8-12-I QS-1/4-10-I

Blanking plug Blanking plug Push-in fitting Blanking plug Blanking plug

B-M7 B-1/4 QS-1/8-8-I B-1/8 B-M7

B-1/8 B-3/8 QS-1/4-10-I B-1/4 B-1/8

B-1/4 B-1/2 QS-3/8-12-I B-3/8 B-1/4

With pneumatic multiple connector plate; code P, GQC E, F, H 82/84 Blanking plug 3/5 Blanking plug 1/11 Push-in fitting 12/14 Push-in fitting

B-M5 B-1/4 QS-1/8-8-I QSM-M5-6-I

B-1/8 B-3/8 QS-1/4-10-I QS-1/8-8-I

B-1/4 B-1/2 QS-3/8-12-I QS-1/4-10-I

B-M5 B-1/4 QS-1/8-8-I B-1/8 B-M5

B-1/8 B-3/8 QS-1/4-10-I B-1/4 B-1/8

B-1/4 B-1/2 QS-3/8-12-I B-3/8 B-1/4

Without pneumatic multiple connector plate A, B 82/84 Blanking plug 3/5 Blanking plug 1 Push-in fitting C, D

G, J, K

G, J, K

2018/09 – Subject to change

82/84 3/5 1 12/14

82/84 3/5 On right in 1, left On right in 11 12/14

82/84 3/5 On right in 1, left On right in 11 12/14

Blanking plug Blanking plug Push-in fitting Blanking plug Blanking plug

è Internet: www.festo.com/catalogue/...

23

Page 24

Valve terminals CPV, Compact Performance Key features – Pneumatic components CPV valve terminal size 10 and 14 with valve extensions Function blocks CPV10-BS-5/3G-M7 CPV14-BS-5/3G-1/8

Valve kit 5/3G for creating a 5/3-way function, mid-position closed, for size 10 and 14: The valve function “mid-position closed” is created using one valve slice with 2x 3/2-way valve, normally closed (valve function code C). The valve kit CPV10-BS-5/3G-M7 or CPV14-BS-5/3G-1/8 (incorporating a double piloted non-return valve function) is used for this. This valve kit is intended for applica­ tions with one working pressure level per valve slice, i.e. it must not be used in dual-pressure applications (where the pressure levels at port 1 and 11 are different).

These valve extensions (vertical stacking) can be used to add further pneumatic functions to CPV valve terminals size 10 and 14:

Two one-way flow control valves for flow regulation directly at the valve terminal for – supply air flow control – exhaust air flow control The vacuum flow control module must be used with the vacuum gen­ erator with or without ejector pulse and provides a non-return function and adjustable ejector pulse

-H- Note

CPV10-BS-2xGRZZ-M7 CPV14-BS-2xGRZZ-1/8

2x one-way flow control valve for supply air flow control Additional function code P

CPV10-BS-2xGRAZ-M7 CPV14-BS-2xGRAZ-1/8

2x one-way flow control valve for exhaust air flow control Additional function code Q

CPV10-BS-GRZ-V-M7 CPV14-BS-GRZ-V-1/8

Vacuum flow control module Additional function code V

Additional functions for valve positions

24

è Internet: www.festo.com/catalogue/...

The additional functions cannot be used in the first or last valve posi­ tion in combination with the pneu­ matic multiple connector plate M, P and cannot be used in combination with the pneumatic multiple connector plate GQC, GQD.

Subject to change – 2018/09

Page 25

Valve terminals CPV, Compact Performance Key features – Assembly Mounting options The valve terminals have holes for four mounting screws. The mounting side is the side with the pneumatic fittings. These holes are also used to mount the valve terminal on a pneumatic multiple connector plate.

There are other mounting options in addition to this method: H-rail mounting Wall mounting Wall mounting via flanged pneumatic multiple connector plate

On rear side via wall mounting On front side (CPV10/14 with IC connection only) Mounting via through-hole in wall

The attachments are mounted with a screw and fixing bolt on the left-hand and right-hand end plates.

For valve terminal CPV10/14: CPV10/14-VI-BG-NRH-35 (mounting code H)

For valve terminal CPV18: CPV18-VI-BG-NRH-35 (mounting code H)

H-rail to EN 60715, not for accessories M, P, V (pneumatic multiple connector plate)

For valve terminal CPV10/14: CPV10/14-VI-BG-RWL-B (mounting code U)

For valve terminal CPV18: CPV18-VI-BG-RW (mounting code W)

Attachment for H-rail

Attachment for wall mounting

Attachment for individual connection and ET200X/ET200pro (included in the scope of delivery) For valve terminal CPV10/14: CPV…-VI-BG-ET200X (mounting code X)

Through-hole in wall, for example on the machine

Wall mounting via pneumatic multiple connector plate

2018/09 – Subject to change

è Internet: www.festo.com/catalogue/...

25

Page 26

Valve terminals CPV, Compact Performance Key features – Assembly Pneumatic multiple connector plate for wall/machine mounting With flange, with all pneumatic connections, code P 1

1

Without flange, with all pneumatic connections, code M

For 10 mm, 14 mm and 18 mm Multiple connector plate projects past the end plates Through mounting holes (without thread) in the flange Two additional holes running laterally through the pneumatic multiple connector plate also enable rear mounting of the CPV valve terminal

1

1 Mounting holes

1 Mounting holes

Pneumatic multiple connector plate for control cabinet assembly With all pneumatic connections, code GQC

With pneumatic ports 2 and 4, code GQD

For 10 mm and 14 mm Multiple connector plate projects past the end plates Mounting holes (with thread) in the flange Multiple connector plate with seal 1

1 1 Mounting holes

For 10 mm, 14 mm and 18 mm Multiple connector plate fits flush with the end plates Mounting holes (with thread) for wall or foot mounting are on the connection side of the pneumatic multiple connector plate

For 10 mm and 14 mm Multiple connector plate fits flush with the end plates The mounting holes (with thread) are on the connection side of the pneumatic multiple connector plate Multiple connector plate with seal

1 Mounting holes

With all pneumatic connections, code GQE For 10 mm Multiple connector plate projects past the end plates Mounting holes (with thread) in the flange Multiple connector plate with seal 1 1 Mounting holes

-H- Note The outer valve slices cannot be equipped with valve extensions (e.g. one-way flow control valve) when using the pneumatic multiple connector plate M or P. CPV valve terminals with flat plate silencers are only suitable for wall mounting.

26

If the pneumatic multiple connector plate GQC, GQD or QQE is used, the following limitations apply: Generally no attachment of valve extensions Not in combination with H-rail mounting Not in combination with wall mounting Only with 10 mm and 14 mm

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/09

Page 27

Valve terminals CPV, Compact Performance Key features – Display and operation Manual override Three types of manual override are available: Non-detenting via slide Detenting Blocked

Code N

Graphical symbol

Subsequent conversion of the manual override from non-detenting to detent­ ing or blocked is possible at any time.

Size 10 14

Note n n

Manual override, detenting

In the “detenting” version, the locking clip is removed and the manual override is activated by pushing the slide down. The non-detenting function can be re-established by re-installing the locking clip. n n

Manual override, blocked

In the “blocked” version, non-detenting and detenting activation of the manual override is prevented by means of a cover. Like the non-detenting locking clip, this cover can be added subsequently, but then remains on the valve. n

2018/09 – Subject to change

See the manual for instructions.

In the “non-detenting” version, the blue slide is held via a locking clip. A pointed object (e.g. pen, etc.) can be used to activate the manual override through the opening.

n

V

-H- Note

18

Manual override, non-detenting n

R

The locking clip on the valve must be removed to this end. This is only possible after the individual valve has been removed or the tie rod of the valve terminal has been released.

n n

è Internet: www.festo.com/catalogue/...

27

Page 28

Valve terminals CPV, Compact Performance Key features – Display and operation Display and operation You will find the following LEDs for displaying the switching status on the electrical connections of the CPV valve terminal:

Display of the switching status of the pilot solenoid coil 12 for outlet port 2 Display of the switching status of the pilot solenoid coil 14 for outlet port 4

CPV valve manifold with individual connection

Readable from the “top” as well as from the “front” The individual connection has an LED in the connector plug to display the switching status.

Inscription labels Clip with inscription field on connection plug (with individual connection) Inscription clips on connection node (multi-pin plug, AS-interface, CP installation system, Fieldbus Direct)

CPV valve terminal with multi-pin plug connection

1 7 3

6

2 3

5 4

4

1 Pre-assembled connecting cable for each pilot solenoid coil 2 Slot for inscription label

3 Yellow LED, signal status display for pilot solenoid coils (for each connecting cable) 4 Earth terminal

5 Terminal lugs for solenoid coil 14 6 Terminal lugs for solenoid coil 12

7 Sub-D multi-pin plug (9-pin for valve terminals with 4 valves, 25-pin for valve terminals with 6 or 8 valves)

Inscription labels can be affixed as follows: On the top of the electrical base unit On the inscription label holder The inscription label holder permits the addition of inscription labels, pro­ tects the manual overrides and pre­ vents them from being accidentally activated. The inscription labels are used to record additional information regarding the valves. The inscription label holders can be ordered together with the valve ter­ minal using the order code. The rel­ evant inscription labels are supplied in a frame and are ordered separately.

The inscription label holder cannot be used together with the relay plate.

Identification system Inscription labels type IBS-6x10 for CPV10/14 type IBS 9x20 for CPV18 Transparent inscription label holder for paper labels (readable from both sides) Inscription label holder Inscription labels type IBS 6x10

28

è Internet: www.festo.com/catalogue/...

Transparent inscription label holder The transparent inscription label holder CPV…-VI-ST-… offers a further labelling option, for example for large paper labels that can be read from both sides.

-H- Note The Word templates for CPV label holders can be found at: www.festo.com

Subject to change – 2018/09

Page 29

Valve terminals CPV, Compact Performance Key features – Electrical components Electrical power means that the valve terminal can be adapted to different electrical require­ ments or fieldbus protocols using the same pneumatic part.

I [mA]

Electrical connection Contacts that are fitted on the top of the valve slices form the interface for various electrical connection options. The electrical connection is attached from above using four screws. This t [ms]

CPV10/14 valves are actuated by means of an integrated current reduc­ tion circuit, which reduces power consumption and heat build-up. This current reduction circuit is integrated in the basic electrical unit (multi-pin plug or fieldbus connection) or in the connecting cable. During switch-off, the voltage peaks are limited to 38 V DC.

Individual connection With an individual connection integration is only carried out in the pneumatic part, the solenoid valves are connected with individual cables.

2018/09 – Subject to change

è Internet: www.festo.com/catalogue/...

29

Page 30

Valve terminals CPV, Compact Performance Key features – Electrical components Download CAD data è www.festo.com

Dimensions – Connecting cable for individual connection KMYZ-7-24-…

1 Mounting screw 2 Wire end sleeve

KMEB-2-24-…-LED

3 Cable, depending on order

1 LED illuminated area 2 Inscription label IBS-9x20 Part No. 18182 3 3-wire cable 2.5 or 5 m (3x 0.75 mm2)

4 Connection pattern to EN 175301-803, type C 5 M2.5 screw, captive, threaded head: Z-combi cross-slot screws to EN 7045

Type

B1

D1

H1

H2

L1

L2

L3

L5

NEBV-Z3WA2L-… KMEB-2-24-2,5-LED KMEB-2-24-5-LED

9.7 16

2.9 7

12.4 26

– 22

26.9 2500 5000

19 34.6

50 16

8.4 –

Download CAD data è www.festo.com

Dimensions – Connecting cable for relay plate KRP-1-24-…

2 Location for inscription labels (order code IBS 6x10, Part No. 18576) 3 Cable, depending on order

5 Mounting screw (self-tapping KB 1.8x9)

Type

B1

D1

H1

H2

L2

L3

KRP-1-24-…

9.8

3.4

16.4

12

28.3

18

30

è Internet: www.festo.com/catalogue/...