Page 31
Valve terminals CPV, Compact Performance Key features – Electrical components ET200X/ET200pro pneumatic interface for CPV10 and CPV14 Adaptation of the CPV valve manifold to the input/output module ET200X/ET200pro from Siemens. The combination of the functional mod ules of the ET200X/ET200pro and the pneumatic functions of the CPV valve manifold provides a highly integrat able automation solution for systems using electrical and pneumatic drives with: 8 valve slices for up to 16 CPV valves Faster and more reliable contacting and valve manifold High IP65/IP67 protection Modular design
Large number of I/O modules – digital I/O – analogue I/O – supply branching for activa tion of three-phase motors Profibus DP interface
Mounting kit for ET200X CPV-…-VI-BG-ET200X (included in the scope of delivery)
Specific data on the ET200X/ET200pro pneumatic interface can be found in Siemens product catalogues.
-H- Note A moulded seal is required for the valve manifold CPV10-ET200pro in order to achieve the IP protection class.
2018/09 – Subject to change
è Internet: www.festo.com/catalogue/...
The moulded seal CPV10-…-GE-8 or CPV14-…-GE-8 must be ordered separately.
31
Page 32
Valve terminals CPV, Compact Performance Key features – Electrical components Multi-pin plug connection In addition to pneumatic integration, a multi-pin plug connection also pro vides integration of the electrical side and facilitates connection to the control cabinet and the valve terminal via a single cable. Sub-D 9-pin and 25-pin plugs are used for connection. The plug housing of the KMP-…- cable provides the Sub-D connectors with IP65 protection.
Pin allocation – Pre-assembled multi-pin cable (viewed from plug-in direction) Plug view Pin
The following sizes of plug connector are used: 4-valve valve terminal: 9-pin 6-valve valve terminal: 25-pin 8-valve valve terminal: 25-pin Prefabricated connecting cables are available for easy connection. Standard lengths of and can be supplied. The pre-assembled connecting cables are also available in a design suitable for use with energy chains.
Wire colour
Cable KMP3-25P-16… or KMP4-25P… with 25-pin Sub-D plug for 6-valve and 8-valve valve terminal 1 White 2 Green 3 Yellow 4 Grey 5 Pink 6 Blue 7 Red 8 Purple 9 Grey-pink 10 Red-blue 11 White-green 12 Brown-green 13 White-yellow 14 Yellow-brown 15 White-grey 16 Grey-brown 17 White-pink (KMP4 only) 18 Pink-brown (KMP4 only) 19 White-blue (KMP4 only) 20 Brown-blue (KMP4 only) 21 White-red (KMP4 only) 22 Brown-red (KMP4 only) 23 White-black (KMP4 only) 24 Brown 25 Black Cable KMP3-9P… or KMP4-9P… with 9-pin Sub-D plug for 4-valve valve terminal 1 2 3 4 5 6 7 8 9 1)
32
The cable KMP6-… can alternatively be used for applications with IP40 protection.
White Green Yellow Grey Pink Blue Red Purple Black
Valve 24 V DC 1 2 3 4 5 6 7 8
14 12 14 12 14 12 14 12 14 12 14 12 14 12 14 12
(0 V)1) (0 V)1)
1 2 3 4
14 12 14 12 14 12 14 12
Common
0 V for positive switching control signals; connect 24 V for negative switching control signals; mixed operation is not permitted.
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/09
Page 33
Valve terminals CPV, Compact Performance Key features – Electrical components Pin allocation – Pre-assembled multi-pin cable (viewed from plug-in direction) Plug view Pin
Wire colour
Cable KMP6-25P-20… with 25-pin Sub-D plug for 6-valve and 8-valve valve terminals 1 White 2 Brown 3 Green 4 Yellow 5 Grey 6 Pink 7 Blue 8 Red 9 Black 10 Purple 11 Grey-pink 12 Red-blue 13 White-green 14 Brown-green 15 White-yellow 16 Yellow-brown 17 White-grey 18 Grey-brown 19 White-pink 20 Pink-brown 21 White-blue1) 22 Brown-blue1) 23 White-red1) 24 Brown-red1) 25 White-black1)
Valve 24 V DC 1 2 3 4 5 6 7 8
14 12 14 12 14 12 14 12 14 12 14 12 14 12 14 12
(0 V)2) (0 V)2)
Cable KMP6-9P-20… with 9-pin Sub-D plug for 4-valve valve terminals 1 2 3 4 5 6 7 8 9 1) 2)
White Brown Green Yellow Grey Pink Blue Red Black
1 2 3 4
14 12 14 12 14 12 14 12
Common
Wire cross section 0.34 mm2 0 V for positive switching control signals; connect 24 V for negative switching control signals; mixed operation is not permitted.
-H- Note Two threaded sleeves (NEAU-TA-M35-U4, è p. 63) are required to secure the multi-pin cable MKP6.
2018/09 – Subject to change
è Internet: www.festo.com/catalogue/...
33
Page 34
Valve terminals CPV, Compact Performance Key features – Electrical components Valve terminal CPV – AS-interface valve terminal The AS-interface facilitates wide rang ing physical distribution of individual components or small component groups. The AS-interface connection of valve terminal CPV can be used to control 2, 4, 8 solenoid coils. The valve terminal cover contains the LEDs that indicate the operating status and the protective circuit for the valves.
The AS-interface protocol standard permits a maximum of 4 inputs and 4 outputs in one unit. The use of 2 ASinterface slaves in one valve terminal means that 8 inputs and 8 outputs can be controlled in an 8-valve valve terminal (8 solenoid coils). All CPV valve terminals can be operated using additional functions, e.g. relay plates or vacuum generators.
AS-interface valve terminal with auxiliary power supply
34
è Internet: www.festo.com/catalogue/...
Valve terminals CPV with inputs are also available for A/B operation to SPEC 2.1 and 3.0. AS-interface control For 2, 4 or 8 valves Great variety thanks to the wide range of modules in the system AS-interface with A/B operation For 3 or 4 and/or 6 or 8 valves depending on the specification All the benefits of the simple installation system are retained
100% more inputs/master 50% more outputs/master Improved peripheral error diagnostics More AS-interface functions in Specifications 2.1 and 3.0
è Internet: as-interface
AS-interface valve terminal with auxiliary power supply and inputs
Subject to change – 2018/09
Page 35
Valve terminals CPV, Compact Performance Key features – Electrical components I-Port interface/IO-Link The I-Port interface/IO-Link enables the valve terminal CPV to be connec ted to the following systems: I-Port master from Festo (CPX terminal, CECC) Fieldbus node CTEU from Festo IO-Link master A maximum of 16 solenoid coils can be actuated distributed over a maximum of 8 valve positions.
The maximum distance between the I-Port/IO-Link master and valve ter minal with I-Port interface/IO-Link is 20 m. The 5-pin connecting cables contain the power supply for the valves, sep arate from this is the power supply for the internal valve terminal electronics and the control signals.
CPV valve terminal with I-Port interface/IO-Link
The valve terminal cover contains the LEDs that indicate the operating status and the protective circuit for the valves. All valve terminals CPV can be oper ated with other functions such as relay plates or vacuum generators.
è Internet: cteu è Internet: cpx è Internet: cecc
CPV valve terminal with I-Port interface with fieldbus node
CP/CPI installation system, valve terminal The integration of valve terminal CPV into a fieldbus system or independent control system is accomplished by connecting the terminal to the corre sponding fieldbus node or control block with simple, pre-assembled ter minal connectors.
The 5-pin connecting cables carry the supply power and control signals. The valve terminal cover contains the LEDs that indicate the operating status and the protective circuits for the valves.
The installation system integrates the valve terminal CPV and various I/O modules, etc. into a single installation concept.
Max. 8 valve slices for up to 16 CPV valves
The CP string is used to exchange the input and output states of the con nected modules with the CP fieldbus node. è Internet: ctec
11
2018/09 – Subject to change
è Internet: www.festo.com/catalogue/...
35
Page 36
Valve terminals CPV, Compact Performance Instructions for use Fieldbus Direct valve terminal Fieldbus Direct is a system for connecting one valve terminal to nine different fieldbus standards. The most important systems, including PROFIBUS, INTERBUS, DeviceNet and CANopen, are supported. The CP string extension option en ables the functions and components of the CPI installation system to be used. The optional string extension permits additional valve terminals and I/O modules with CP/CPI function to be connected to the Fieldbus Direct fieldbus node.
Depending on the version, the valve terminals are available in all three sizes, 10, 14 and 18 mm, each with 8 valve slices.
Equipment Operate system equipment with unlu bricated compressed air if possible. Festo valves and cylinders are de signed so that, if used as designated, they will not require additional lu brication and will still achieve a long service life. The quality of compressed air down stream of the compressor must corre spond to that of unlubricated com pressed air. If possible, do not operate all your system equipment with lubri cated compressed air. The lubricators should, where possible, always be installed directly upstream of the actuator used.
Incorrect additional oil and too high an oil content in the compressed air reduce the service life of the valve terminal. Use Festo special oil OFSW-32 or the alternatives listed in the Festo catalogue (as specified in DIN 51524 HLP32; basic oil viscosity 32 CST at 40°C).
36
è Internet: www.festo.com/catalogue/...
Bio-oils When using bio-oils (oils based on synthetic or native ester, e.g. rapeseed oil methyl ester), the maximum residual oil content of 0.1 mg/m3 must not be exceeded (see ISO 8573-1 Class 2).
Mineral oils When using mineral oils (e.g. HLP oils to DIN 51524, parts 1 to 3) or similar oils based on poly-alpha-olefins (PAO), the maximum residual oil con tent of 5 mg/m3 must not be exceeded (see ISO 8573-1 Class 4). A higher residual oil content irrespec tive of the compressor oil cannot be permitted, as the basic lubricant would be flushed out over time.
Subject to change – 2018/09
Page 37
Valve terminals CPV, Compact Performance Technical data
-M- Flow rate up to
CPV10: 400 l/min CPV14: 800 l/min CPV18: 1600 l/min
-K- Valve width
CPV10: 10 mm CPV14: 14 mm CPV18: 18 mm
-P- Voltage
24 V DC
General technical data CPV10 Design Lubrication Type of mounting
Mounting position Lap Manual override Width Nominal size Nominal flow rate without fitting
[mm] [mm] [l/min] b value c value
[l/sbar]
Pneumatic connections1) Pneumatic connection Supply port Exhaust port Working ports Pilot air supply port Pilot exhaust air port
1/11 3/5 2/4 12/14 82/84
1) 2) 3)
CPV14
CPV18
Electromagnetically actuated piston spool valve Life-time lubrication, PWIS-free (free of paint-wetting impairment substances) Via pneumatic multiple connector plate Via backwall On H-rail Any Overlap Non-detenting/detenting/blocked 10 14 18 4 6 8 400 800 1600 1400 3) 0.4 0.42 0.38 0.372) 0.412) 0.403) 1.6 3.2 6.3 5.663)
Via end plate or pneumatic multiple connector plate G1/8 G1/4 G3/8 (G1/4) G1/2 (G3/8) M7 G1/8 M5 (M7) G1/4 M5 (M7) G1/8
G3/8 G1/2 G1/4 G1/4 G1/4
Connection dimensions in brackets for pneumatic multiple connector plate Values for 2x 2/2-way valve Values for 5/3-way valve with mechanical spring return
Safety characteristics CPV10 Max. positive test pulse with 0 signal Max. negative test pulse with 1 signal Shock resistance Vibration resistance
2018/09 – Subject to change
[ìs] [ìs]
CPV14
1400 1400 700 400 Shock test with severity level 2, to EN 60068-2-27 Transport application test with severity level 2, to EN 60068-2-6
è Internet: www.festo.com/catalogue/...
CPV18 1900 1700
37
Page 38
Valve terminals CPV, Compact Performance Technical data Operating and environmental conditions Valve function order code Operating medium Note on operating/pilot medium Operating pressure Operating pressure for valve terminal with internal pilot air supply Pilot pressure Ambient temperature Temperature of medium Storage temperature Relative air humidity at 25 °C Corrosion resistance class CRC1) Note on materials 1)
M, MK
[bar] [bar] [bar] [°C] [°C] [°C] [%]
F
J, JK
N, NK
C, CK
CY
H, HK
G
D, DK
I, IK
A
E
Compressed air to ISO 8573-1:2010 [7:4:4] è page 36 Lubricated operation possible (in which case lubricated operation will always be required) –0.9 … +10 +0.1 … +10 –0.9 … +10 3…8 3…8 –5 … +50 (vacuum generators: 0 … +50) –5 … +50 (vacuum generators: 0 … +50) –20 … +40 95 with no condensation 2 RoHS-compliant
1
Corrosion resistance class CRC 1 to Festo standard FN 940070 Low corrosion stress. For dry indoor applications or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive trunnions). Corrosion resistance class CRC 2 to Festo standard FN 940070 Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo sphere typical for industrial applications.
ATEX ATEX category for gas Type of ignition protection for gas ATEX category for dust Certification Explosion protection certification outside the EU CE marking (see declaration of conformity)
II 3G Ex nA IIC T4 X Gc –5 ≤ Ta ≤ +50 c UL us Recognized (OL) C-Tick NEC 500 Class I, Div. 2 To EU Explosion Protection Directive (ATEX) To EU EMC Directive
-H- Note The ATEX certification in accordance with the EU ATEX directive only applies to fully assembled valve terminals.
ATEX Permitted pneumatic multiple connector plates for the valve terminal CPV Pneumatic multiple connector plate CPV10-VI-P…-1/8-C ATEX category for gas Type of ignition protection for gas ATEX category for dust Type of ignition protection for dust ATEX ambient temperature Certificate issuing authority
[°C]
Explosion protection certification outside the EU CE marking (see declaration of conformity)
38
CPV10VIP…-M7-…
II 2G Ex e II II 2D Ex tD A21 IP65 –10 ≤ Ta ≤ +60 TÜV 06 ATEX 7334 X IECEx TUR 12.0002X EPL Db (IEC-EX) EPL Gb (IECEx) To EU Explosion Protection Directive (ATEX)
è Internet: www.festo.com/catalogue/...
CPV14-VI-P…-1/8-…
TÜV 06 ATEX 7334 X – –
Subject to change – 2018/09
Page 39
Valve terminals CPV, Compact Performance Technical data Electrical CPV10 Operating voltage Edge steepness (IC and MP only) Limitation of the voltage peaks when switching off Residual ripple Electrical power consumption
CPV14
CPV18
[V DC] [V/ms]
24 (+10/–15%) 0.4 minimum voltage increase time to reach the high-current phase
[V DC]
38
[Vss] [W]
4 0.6 (0.45 at 21 V); 0.9 (0.65 at 21 V) (at CPV10-M11H-… 0.65) 100 –0.9 … +10 By means of PELV power supply unit
Duty cycle ED [%] with pilot air supply [bar] Protection against electric shock (protection against direct and indirect contact to EN 60204-1/IEC 204) Degree of protection to EN 60529 [IP]
1.5 (0.95 at 21 V)
65 (for all types of signal transmission in mounted state)
Relay plate CPV10 Operating voltage Electrical power consumption No. of relays Load current circuit Relay response times On Off
Valve switching times [ms] Valve function order code CPV10 Switching times
CPV14 Switching times
CPV18 Switching times
2018/09 – Subject to change
[V DC ] [W]
[ms] [ms]
CPV14
CPV18
20.4 … 26.4 1.2 2 with galvanically isolated outputs Each 1 A/24 V DC +10% 5 2
– – – – – –
M
MK
F
J
JK
N
NK
C
CK
CY
H
HK
G
D
DK
I
IK
A
E
On 17 Off 27 Change – over
17 27 –
12 17 –
– – 10
– – 10
17 25 –
17 25 –
17 25 –
17 25 –
17 25 –
17 25 –
17 25 –
20 30 –
15 17 –
15 17 –
15 17 –
15 17 –
– – –
15 17 –
On 25 Off 35 Change – over
25 35 –
– – –
– – 12
– – 12
24 30 –
24 30 –
24 30 –
24 30 –
– – –
24 30 –
24 30 –
22 30 –
13 16 –
13 16 –
13 16 –
13 16 –
– – –
13 16 –
On 18 Off 26 Change – over
– – –
– – –
– – 12
– – –
18 24 –
– – –
18 24 –
– – –
– – –
– – –
– – –
14 32 –
14 20 –
– – –
14 20 –
– – –
– – –
14 20 –
è Internet: www.festo.com/catalogue/...
39
Page 40
Valve terminals CPV, Compact Performance Technical data Materials CPV10 Basic electrical unit Valve slices Valve module 5/3G Relay plate Blanking plate/separator plate End plates Flat plate silencer Pneumatic multiple connector plate Inscription label holder Seal
Product weight Approx. weight
[g]
Electrical connection plates with AS-Interface connection on CP valve terminals with 2 valve positions on CP valve terminals with 4 valve positions on CP valve terminals with 8 valve positions Electrical connection plates with CP connection on CP valve terminals with 4 valve positions on CP valve terminals with 6 valve positions on CP valve terminals with 8 valve positions Electrical connection plates with MP connection on CP valve terminals with 4 valve positions on CP valve terminals with 6 valve positions on CP valve terminals with 8 valve positions End plates (2 pieces) Pneumatic multiple connector plate on CP valve terminals with 2 valve positions on CP valve terminals with 4 valve positions on CP valve terminals with 6 valve positions on CP valve terminals with 8 valve positions Flat plate silencer Relay plate Blanking plate Separator plate Valve sub-bases, vacuum generators Function element: 5/3G function Function element: one-way flow control valve
40
CPV14
CPV18
CPV10
CPV14
CPV18
85 110 400
130 175 460
275 355 –
145 180 200
230 250 300
– – –
110 140 165 160
170 230 275 280
400 425 515 740
120 165 225 270 147 35 25 25 70 46 25
270 390 510 630 234 55 45 45 110 105 54
520 750 870 1300 – – 90 90 260 – 125
Die-cast aluminium, PA, NBR Die-cast aluminium Cast aluminium, POM PA, brass PA Die-cast aluminium Die-cast aluminium, PE Wrought aluminium alloy POM, PVC NBR, HNBR