CPX terminal Manual Electronics: CPX field bus node Type CPX-FB32, Fieldbus protocol EtherNet/IP: Ethernet/IP Objects of the CPX-FB32, pages 108 to 116

Pages 108 to 116 of 146, from CPX terminal Manual Electronics: CPX field bus node Type CPX-FB32, Fieldbus protocol EtherNet/IP

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Festo CPX-FB-32

Page 108

B. Ethernet/IP Objects of the CPX-FB32

B.3

Objects for the I/O connection

B.3.1 Assembly Object Object class: Instances:

4 3

The Assembly Object bundles together Attributes of various Objects, so that the exchange of data with the Objects can take place via one connection. The following Object instances are saved in the Assembly Object:

B-10

Instance

Description

101

Input data

100

Output data

102

Configuration data

Festo P.BE-CPX-FB32-EN en 1111a

Page 109

B. Ethernet/IP Objects of the CPX-FB32

Remote I/O operating mode Each data range begins on the LSB (least significant bit) of a word. Instance 101: Input Within the instance “Input Assembly Object” all inputs of the CPX system are transmitted cyclically over the network by means of a communication connection. The following sequence applies during transmission: Sequence of transmission 1.

I/O diagnostic interface, if active (16-bit orientated)

2.

Object instances of the analogue channels (16-bit orientated)

3.

Instances of the technology modules (16 or 8-bit orientated)

4.

Object instances of the digital inputs (8-bit orientated)

Instance 101 (input) possesses the following member list in the operating mode Remote I/O: Obj.

Instances Attributes (= Module no. + 1) (channel)

Entries in member list

Type

133

1 ... 48

0/1

I/O diagnostic interface data, if active

WORD

104

1 ... 48

1 ... 32

Analogue channel data

WORD

106

1 ... 48

1 ... 64 / 65 ... 96

Technology module

BYTE/ WORD

102

1 ... 48

1 ... 64

Digital Data

BOOL

Festo P.BE-CPX-FB32-EN en 1111a

B-11

Page 110

B. Ethernet/IP Objects of the CPX-FB32

Instance 100: Output Within the Instance Output in the Assembly Object all outputs of the CPX system will be transmitted over the network by means of one communication connection. The following sequence applies during transmission: Sequence of transmission 1.

I/O diagnostic interface/status byte, if active (16-bit orientated)

2.

Object instances of the analogue channels (16-bit orientated)

3.

Instances of the technology modules (16 or 8-bit orientated)

4.

Object instances of the digital outputs (8-bit orientated)

Instance 100 (Output) possesses the following member list in the operating mode Remote I/O: Obj.

Instances Attributes (= Module no. + 1) (channel)

Entries in member list

Type

133

1 ... 48

0/1

I/O diagnostic interface data, if active

WORD

105

1 ... 48

1 ... 32

Analogue channel data

WORD

107

1 ... 48

1 ... 64 / 65 ... 96

Technology module

BYTE/ WORD

103

1 ... 48

1 ... 64

Digital Data

BOOL

Instance 102: Configuration Instance 102 (Configuration) possesses the following member list:

B-12

Obj.

Number of

Entries in member list

Type

199

1

Configuration Array data

ARRAY

Festo P.BE-CPX-FB32-EN en 1111a

Page 111

B. Ethernet/IP Objects of the CPX-FB32

The I/O Objects 102 ... 107 also possess the following attributes:

Festo P.BE-CPX-FB32-EN en 1111a

Attribute

Entries ...

Type

100

Number of data of the module in BYTE or WORD

BYTE

101

Data type: – D1h: BYTE – D2h: WORD

BYTE

102

All data values

ARRAY

B-13

Page 112

B. Ethernet/IP Objects of the CPX-FB32

Remote controller operating mode Each data range begins on the LSB (least significant bit) of a word. Instance 100: Output Instance 100 (Output) possesses the following member list in the operating mode Remote Controller: Obj.

Number of

Entries in member list

Type

107

1 ... 64 / 65 ... 96

Technology module

BYTE/ WORD

Instance 101: Input Instance 101 (input) possesses the following member list: Obj.

Number of

Entries in member list

Type

106

1 ... 64 / 65 ... 96

Technology module

BYTE/ WORD

Transmission by communication types Polled I/O or COS/Cyclic. Instance 102: Configuration Instance 102 (Configuration) must have the value “0” in the operating mode Remote Controller.

B-14

Festo P.BE-CPX-FB32-EN en 1111a

Page 113

B. Ethernet/IP Objects of the CPX-FB32

B.4

Objects for system data and diagnosis

B.4.1 Identity Object Object class: Instances:

01 1

The Identity Object contains the identification and general information on the CPX-FB32.

Festo P.BE-CPX-FB32-EN en 1111a

Attr. No.

Access

Description

Type

1

Get

Vendor ID

WORD

2

Get

Device type

WORD

3

Get

Product code

WORD

4

Get

Revision (major/minor)

WORD

5

Get

Status

WORD

6

Get

Serial number

DOUBLE

7

Get

Product name

ARRAY

14

Get/Set

Semaphore

ARRAY

100

Get

Operating Mode

BOOL

101

Get

External Module Identifiers

ARRAY

B-15

Page 114

B. Ethernet/IP Objects of the CPX-FB32

B.4.2 System Object (for operating mode Remote I/O) Object class: Instances:

132 1

This Object is only available in the operating mode Remote I/O. Attr. No.

Access

Description

Type

Function no.

1

Get

CPX operating mode (bit 0 ... 3) 0: Remote I/O without FEC/CEC 1: Remote I/O with FEC or CEC 2: Remote controller without bus node 3: Remote controller with bus node

BYTE

0 (bit 0 ... 3)

B-16

CPX equipment status (bit 4) Specifies whether the current equipment fitted to the CPX corresponds to the saved CPX equipment status. 0: equal 1: unequal

0 (bit 4)

Handheld (bit 5) Specifies whether or not a handheld is connected. 0: No handheld connected 1: Handheld connected

0 (bit 5)

Force mode (bit 6) Specifies whether Force is blocked or enabled. 0: blocked 1: enabled

0 (bit 6)

Bit 7: reserved

0 (bit 7)

Festo P.BE-CPX-FB32-EN en 1111a

Page 115

B. Ethernet/IP Objects of the CPX-FB32

Attr. No.

Access

Description

Type

Function no.

2

Get

Fail safe Specifies whether Fail Safe is active or inactive. 0: inactive 1: active

BYTE

1 (bit 0, 1)

System Idle mode Specifies whether Idle mode is active or inactive. 0: inactive 1: active

1 (bit 2, 3)

3

Get

Monitoring CPX terminal (bit 0 ... 7) Specifies whether the monitoring of short circuit/overload and undervoltage is active or inactive. Bit 0: Monitoring SCS (short circuit/ overload sensor supply) Bit 1: Monitoring SCO (short circuit/ overload outputs) Bit 2: Monitoring VOut (Undervoltage outputs) Bit 3: Monitoring VVal (Undervoltage valves) Bit 4: Monitoring SCV (short circuit valves) Bits 5 ... 7: reserved 0: inactive 1: active

BYTE

2 (bit 0 ... 7)

4

Get

Number of input bytes (Rx size) Specifies the number of input bytes of the CPX terminal.

BYTE

-

5

Get

Number of output bytes (Tx size) Specifies the number of output bytes of the CPX terminal.

BYTE

-

Festo P.BE-CPX-FB32-EN en 1111a

B-17

Page 116

B. Ethernet/IP Objects of the CPX-FB32

Attr. No.

Access

Description

Type

Function no.

9

Get/Set

Monitoring (bit 0 ... 7) Bit 0: Monitoring SCS (short circuit/ overload sensor supply) Bit 1: Monitoring SCO (short circuit/ overload outputs) Bit 2: Monitoring Uout (Undervoltage outputs) Bit 3: Monitoring Uval (Undervoltage valves) Bit 4: Monitoring SCV (short circuit valves) Bits 5 ... 7:reserved 1: active (presetting) 0: inactive

BYTE

4401 (bit 0 ... 7)

10

Get/Set

Fail safe 0: Reset all outputs (presetting) 1: Hold last state (Retain signal status) 2: Assume Fault mode

BYTE

4402 (bit 0, 1)

11

Get/Set

Force mode 0: blocked 1: enabled

BYTE

4402 (bit 2, 3)

12

Get/Set

System Idle mode 0: Reset all outputs (presetting) 1: Hold last state (Retain signal status) 2: Assume Idle mode

BYTE

4402 (bit 4, 5)

13

Get/Set

System start 0: System start with default parameterisation (factory setting) and current CPX disassembly; external parameterisation possible (presetting) 1: System start with stored parameterisation and stored CPX expansion; Parameter and CPX-expansion are stored remanently; external parameterisation is blocked; the M-LED on the fieldbus node is lit

BYTE

4402 (bit 6)

B-18

Festo P.BE-CPX-FB32-EN en 1111a