For the Festo FBA-2-M12-5pol

Page 11

Fieldbus Direct Key features – Electrical connection Operating voltage and load current supply The operating voltages for the Fieldbus Direct valve terminal and for the ex­ tension modules are connected cen­ trally via the 4- or 5-pin M12 plug. It must supply the operating voltages for the electronic unit of the fieldbus node and the modules connected to the CP string. The load supply for the valves is supplied separately from the supply for the electronic unit. The valves of the Fieldbus Direct valve terminals and the valves/outputs on the CP string extension are supplied together via pin 2 of the M12 plug. The power supply for the sensors connected to the input module is nor­ mally also supplied by the M12 plug. Up to 500 mA for the sensor supply is made available to the connected input module via the CP string. A separate, electrically isolated sensor supply is available with the two input modules CP-E16-KL-IP20-Z and CP-E16-M8-Z. In this case, a max. current of 2 A is available for the sensors.

Since the CP string carries the lines for both communication and the entire power supply for the connected modules, it represents a very easily installed extension option. The following functions are supported via the CP string: Connection for data exchange Power supply for the connected modules Sensor voltage supply of up to 500 mA

Load voltage supply for the connected valves The electrical modules are protected against overload by electronic fuses. All diagnostic information for the mod­ ules is transferred to the fieldbus node via the CP string and from there for­ warded to the PLC according to the rel­ evant protocol.

Example of circuitry for CPV Direct – Connection of load voltage

1

0V

1 Connection for power supply on the CPV Direct valve terminal 2 Protective earth (PE) 3 Equipotential bonding 4 Load voltage (can be discon­ nected separately) and external fuse 5 Earth terminal on pin 4, configured for 3 A

2A 24 V

2

2A

4

3

3 5

Pin allocation – Power supply for CPV Direct Pin Description 1 2 3 4

2018/06 – Subject to change

24 V DC electronics and sensors 24 V DC valves and outputs 0 V electronics and sensors Earth terminal

Notes The voltage is supplied via a 4-pin M12 plug (A-coded).

è Internet: www.festo.com/catalogue/...

11

Page 12

Fieldbus Direct, CPV-DI01 Technical data – Fieldbus node CPV-DI01 CPV fieldbus node for communication between a CPV valve terminal and a fieldbus master. The fieldbus node is used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the signal status via LED. The CPV-… valves are activated via automatic current reduction, which results in less power consumption and heat emission. 16 digital inputs and 8 digital outputs or 16 valves can be connected via a serial CP string extension. DI01 supports 4 different fieldbus protocols, which are selected by means of DIL switches: PROFIBUS DP Moeller SUCOnet K ABB CS31 Festo fieldbus The CPV fieldbus node is available in three sizes, with identical performance characteristics: CPV10 CPV14

Application Bus connection Sub-D socket

12

M12 adapter

è Internet: www.festo.com/catalogue/...

Sub-D socket 9-pin Sub-D socket Installation with IP65 protection

M12 adapter Plug connector 2xM12 Installation with IP65 protection

The bus connection is established via a 9-pin Sub-D socket with a typical PROFIBUS allocation (to EN 50 170). The bus connector plug (with protec­ tion class IP65 from Festo or IP20 from other manufacturers) facilitates the connection of an incoming and an outgoing bus cable. An active bus terminal can be connected using the integrated DIL switch. The Sub-D inter­ face is designed for the activation of network components via a fibre optic cable connection.

Alternatively the bus connection can be established via a 2x M12 adapter (B-coded).

Subject to change – 2018/06

Page 13

Fieldbus Direct, CPV-DI01 Technical data – Fieldbus node CPV-DI01 General technical data Type

CPV10-GE-DI01-8

Fieldbus interface

Electrical isolation of the fieldbus interface Baud rates Addressing range PROFIBUS DP (12 MBaud) Festo fieldbus ABB CS31 Moeller SUCONET K CP/CPI string extension LED display (bus-specific) BUS LED display Product-specific Power Product identification Ident. number Type of communication Configuration support Max. no. of solenoid coils Max. no. of solenoid coils with string extension Max. no. of outputs Max. no. of inputs Device-specific diagnostics

Operating voltage

Current consumption Protection class to EN 60529 Materials

Nominal value Permissible range Residual ripple Power failure bridging

[kbps]

[V DC] [V] [Vss] [ms] [mA]

Housing Cover Seal

Dimensions Weight Technical data on valves

CPV14-GE-DI01-8

Either Sub-D socket, 9-pin Socket and plug, M12x1, 5-pin, B-coded Via optocoupler 9.6 … 12,000; automatic detection 1 … 125; Set using a switch module

Yes, 16 inputs and 8 outputs (or 16 valves) Communication and configuration errors Valve signal status Operating voltage for electrics and load supply Product family 4: Valves 0xC9 Cyclical communication GSD file and bitmaps 16 32 8 (1x16 solenoid coils omitted) 16 Short circuit/overload of outputs Undervoltage of valves Undervoltage of outputs Undervoltage of sensor supply Missing module on CP/CPI string extension Via device-specific diagnostics (DPVO) 24, reverse polarity protected 20.4 … 26.4 4 10 Max. 100 + sensor supply IP65 Die-cast aluminium Reinforced polyamide Nitrile rubber è Internet: cpv

Operating and environmental conditions Ambient temperature Storage temperature Fieldbus certification Certification CE symbol (see declaration of conformity)

2018/06 – Subject to change

[°C] [°C]

–5 … +50 –20 … +70 PNO cULus recognized (OL) In accordance with EU EMC directive

è Internet: www.festo.com/catalogue/...

13

Page 14

Fieldbus Direct, CPV-DI01 Technical data – Fieldbus node CPV-DI01 Connection and display components 1 Red LED: Bus status/error (BUS) 2 Green LED: Power supply (POWER) 3 Yellow LED row: For pilot solenoid coils 12 4 Yellow LED row: For pilot solenoid coils 14

1 2 3 4

Pin allocation for fieldbus interface (viewed on plug) Pin Festo Sub-D plug (IP65)

Manufacturer-specific signal designation Festo fieldbus ABB CS31 PROFIBUS DP interface n.c. n.c. RxD/TxD-P CNTR-P DGND VP n.c. RxD/TxD-N n.c. Screened

Moeller SUCONET K Sub-D DIN (round) 9-pin 5-pin

1 2 3 4 5 6 7 8 9 Hous­ ing

– – B – – – – A – Cable clip

– – S+ – – – – S– Screened

– – Bus1 – – – – Bus2 – Screened

– – 3 (TA/RA) – – – – 7 (TB/RB) – 4 (screened)

Bus In (pin)

Bus Out (socket)

PROFIBUS DP (signal)

Description

M12 and 5 4 – – 2

M12 and 5

Screened

Screened or functional earth

4 3 1 2

RxD / TxD-P DGND VP (P5V) RxD / TxD-N

Data B Reference potential to supply voltage positive (VP) Supply voltage positive Data A

– – 4 (TA/RA) – – – – 1 (TB/RB) – Housing

Pin allocation for M12 adapter

14

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/06

Page 15

Fieldbus Direct, CPV-DI01 Accessories – Fieldbus node CPV-DI01 Ordering data Designation

Part No.

Type

CPV10

165809

CPV10-GE-DI01-8

CPV14

165811

CPV14-GE-DI01-8

For setting bus parameters and device configuration in the case of CPV

165814

CPV10/14/18-GE-DI-SM

For cable 4 … 6 mm

18494

SIE-GD

For cable 8 … 9.5 mm

18495

FBSD-GD-9

For cable 4 … 6 mm

12956

SIE-WD-TR

For cable 6 … 8 mm

18525

FBSD-WD-9

Fieldbus socket, Sub-D connection

532216

FBS-SUB-9-GS-DP-B

Bus connection Micro Style M12 Bus connection Micro Style, 2xM12

533118

FBA-2-M12-5POL-RK

Fieldbus node

Switch module

Power supply Power supply socket, straight, M12x1, 4-pin

Power supply socket, angled, M12x1, 4-pin

Fieldbus connection

Socket M12x1, 5-pin, straight, for self-assembly of a connecting cable for FBA-2-M12-5POL-RK

1067905 NECU-M-B12G5-C2-PB

Plug M12x1, 5-pin, straight, for self-assembly of a connecting cable for FBA-2-M12-5POL-RK

1066354 NECU-M-S-B12G5-C2-PB

Fieldbus socket for Micro Style connection, M12, 5-pin, straight

18324

FBSD-GD-9-5POL

Plug for Micro Style connection, M12, 5-pin, straight

175380

FBS-M12-5GS-PG9

0.25 m 0.5 m 2m 5m 8m 2m 5m 8m

540327 540328 540329 540330 540331 540332 540333 540334

KVI-CP-3-WS-WD-0,25 KVI-CP-3-WS-WD-0,5 KVI-CP-3-WS-WD-2 KVI-CP-3-WS-WD-5 KVI-CP-3-WS-WD-8 KVI-CP-3-GS-GD-2 KVI-CP-3-GS-GD-5 KVI-CP-3-GS-GD-8

German English Italian French Spanish

165816 165817 165818 165819 165820

P.BE-CP-DI01-DE P.BE-CP-DI01-EN P.BE-CP-DI01-IT P.BE-CP-DI01-FR P.BE-CP-DI01-ES

Valve terminal connection Connecting cable, angled plug, angled socket

Connecting cable, straight plug, straight socket

User documentation User documentation for CPV Direct, CPV fieldbus node DI01

2018/06 – Subject to change

è Internet: www.festo.com/catalogue/...

15

Page 16

Fieldbus Direct, CPV-DI02-8 Technical data – Fieldbus node CPV-DI02-8 CPV fieldbus node according to the CP system with Specification “B” for communication between a CPV valve terminal and a fieldbus master. The fieldbus node is used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the signal status via LED. The CPV-… valves are activated via automatic current reduction, which results in less power consumption and heat emission. 32 digital inputs and outputs or 32 solenoid coils can be connected via a serial CP string extension. The CPV fieldbus node is available in three sizes, with identical performance characteristics: CPV10 CPV14

Application Bus connection Screw terminals

16

Plug connector 2xM12

Sub-D fieldbus plug

è Internet: www.festo.com/catalogue/...

Sub-D socket 9-pin Sub-D socket Installation with IP65 protection

M12 adapter Plug connector 2xM12 Installation with IP65 protection

The bus connection is established via a 9 pin Sub-D socket with a typical PROFIBUS allocation (to EN 50170). The bus connector plug (with protec­ tion class IP65 from Festo or IP20 from other manufacturers) facilitates the connection of an incoming and an outgoing bus cable. An active bus terminal can be connected using the integrated DIL switch. The Sub-D inter­ face is designed for the activation of network components via a fibre optic cable connection.

Alternatively the bus connection can be established via a 2x M12 adapter (A-coded). Screw terminals 5-pin screw terminal strip for installation in protected environ­ ments (IP20). The bus connection is established via a 5-pin row. If the valve terminal is ordered with this bus connection, the 5-pin screw terminal strip will also be supplied. It is designed with double screw terminals for the incoming and the outgoing bus cable. This connection technology provides a T-distributor function.

Subject to change – 2018/06

Page 17

Fieldbus Direct, CPV-DI02-8 Technical data – Fieldbus node CPV-DI02-8 General technical data Type Fieldbus interface

CPV10-GE-DI02-8 Either

Electrical isolation of the fieldbus interface CP string extension Baud rates Addressing range

PROFIBUS DP (12 MBaud)

LED display

Bus-specific Product-specific Power

[kbps]

Ident. number Type of communication Configuration support Max. no. of solenoid coils Max. no. of solenoid coils with string extension Max. no. of outputs Max. no. of inputs LED diagnostic displays POWER BUS Device-specific diagnostics

Operating voltage

Nominal value Permissible range Residual ripple Power failure bridging

Current consumption Protection class to EN 60529 Materials

[V DC] [V] [Vss] [ms] [mA]

Housing Cover Seals

Dimensions Weight Technical data on valves

CPV14-GE-DI02-8

Screw terminal strip, 5-pin Sub-D socket, 9-pin Socket and plug, M12x1, 5-pin, B-coded Via optocoupler Yes, 32 inputs and 32 outputs 9.6 … 12,000; Automatic detection 1 … 125; Set using a switch module Communication and configuration errors Valve signal status Operating voltage for electrics and load supply 0xC9 Cyclical communication GSD file and bitmaps 16 48 with string extension 16 solenoid coils and 32 outputs 32 Operating voltage for electronics and load supply Communication and configuration errors Short circuit/overload of outputs Undervoltage of valves Undervoltage of outputs Undervoltage of sensor supply Missing module on CP string extension Via device-specific diagnostics (DPVO) 24, reverse polarity protected 20.4 … 26.4 4 10 Max. 100 + sensor supply IP20 with 5-pin screw terminal strip IP65 Sub-D, socket/plug M12x1 Die-cast aluminium Reinforced polyamide Nitrile rubber, polychloroprene rubber è Internet: cpv

Operating and environmental conditions Ambient temperature Storage temperature Fieldbus certification Certification CE symbol (see declaration of conformity) Note on materials

2018/06 – Subject to change

[°C] [°C]

–5 … +50 –20 … +70 PNO cULus recognized (OL) In accordance with EU EMC directive RoHS-compliant

è Internet: www.festo.com/catalogue/...

17

Page 18

Fieldbus Direct, CPV-DI02-8 Technical data – Fieldbus node CPV-DI02-8 Connection and display components 1 Fieldbus connection (9-pin Sub-D socket) 2 Removable switch cover 3 Operating/load voltage connection (4-pin M12 plug) 4 Power LEDs (PS, PL) and bus status LEDs (BF)

1

2 3 4

Pin allocation for PROFIBUS DP interface (viewed on plug) Pin Signal

Description

1 2 3 4 5 6 7 8 9 Hous­ ing n.c. n.c. RxD/TxD-P CNTR-P DGND VP n.c. RxD/TxD-N n.c. Screened

Not connected Not connected Received/transmitted data P Repeater control signal Data reference potential (M5V) Supply voltage positive (P5V) Not connected Received/transmitted data N Not connected Connection to functional earth

Pin

Signal

Description

1 2 3 4 5

VP RxD/TxD-N DGND RxD/TxD-P FE

Supply voltage positive (P5V) Received/transmitted data N Data reference potential (M5V) Received/transmitted data P Functional earth

Pin allocation for M12 adapter

18

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/06

Page 19

Fieldbus Direct, CPV-DI02-8 Accessories – Fieldbus node CPV-DI02-8 Ordering data Designation

Part No.

Type

CPV10

546188

CPV10-GEDI02-8

CPV14

546190

CPV14-GEDI02-8

For setting bus parameters and device configuration in the case of CPV

165814

CPV10/14/18-GE-DI-SM

For cable 4 … 6 mm

18494

SIE-GD

For cable 8 … 9.5 mm

18495

FBSD-GD-9

For cable 4 … 6 mm

12956

SIE-WD-TR

For cable 6 … 8 mm

18525

FBSD-WD-9

Fieldbus socket, Sub-D connection

532216

FBS-SUB-9-GS-DP-B

M12 adapter

525632

FBA-2-M12-5POL

Bus connection, 5-pin screw terminal strip Open Style adapter for 5-pin terminal strip

525634

FBA-1-SL-5POL

5-pin terminal strip

525635

FBSD-KL-2x5POL

0.25 m 0.5 m 2m 5m 8m 2m 5m 8m

540327 540328 540329 540330 540331 540332 540333 540334

KVI-CP-3-WS-WD-0,25 KVI-CP-3-WS-WD-0,5 KVI-CP-3-WS-WD-2 KVI-CP-3-WS-WD-5 KVI-CP-3-WS-WD-8 KVI-CP-3-GS-GD-2 KVI-CP-3-GS-GD-5 KVI-CP-3-GS-GD-8

German English Spanish French Italian

548731 548732 548733 548734 548735

P.BE-CPV-DI02-DE P.BE-CPV-DI02-EN P.BE-CPV-DI02-ES P.BE-CPV-DI02-FR P.BE-CPV-DI02-IT

Fieldbus node

Switch module

Power supply Power supply socket, straight, M12x1, 4-pin

Power supply socket, angled, M12x1, 4-pin

Fieldbus connection

Valve terminal connection Connecting cable, angled plug, angled socket

Connecting cable, straight plug, straight socket

User documentation User documentation for CPV Direct, CPV fieldbus node DI02-8

2018/06 – Subject to change

è Internet: www.festo.com/catalogue/...

19