AF-300 G11 User's Guide, pages 1 to 10

Pages 1 to 10 of 160

The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the GE AF-300G11, Fanuc AF-300G11 and GE Fanuc AF-300G11

Page 1 read from a scan by OCR; it may hold reading errors

GEI-100363C Supersedes GEI-100363B

FiuSi SUEErielwG GE Fuji Drives USA

AF-300 Gil

User’s Guide

Page 2

This page is a scan with no text; see it in the PDF.

Page 3

© 1999, 2000 by GE Fuji Drives USA, Inc. All rights reserved.

These instructions do not purport to cover all details or variations in equipment, nor to provide every possible contingency to be met during installation, operation, and maintenance. If further information is desired, or if particular problems arise that are not covered sufficiently for the purchaser’s purpose, the matter should be referred to GE Fuji Drives USA, Salem, Virginia, USA. This document contains proprietary information of GE Fuji Drives USA and is furnished to its customer solely to assist that customer in the installation, testing, operation, and/or maintenance of the equipment described. This document shall not be reproduced in whole or in part, nor shall its contents be disclosed to any third party without the written approval of GE Fuji Drives USA.

AF-300 G11 is a trademark of GE Fuji Drives USA, Inc. Energy $aver is a registered trademark of General Electric Company, USA. Genius is a registered trademark of GE Fanuc Automation North America, Inc. Profibus is a trademark of Profibus International. X$D is a trademark of General Electric Company, USA.

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Page 4

Notes

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Page 5

Table of Contents i. Preface Safety Instructions .................................................. iii Model Numbering System Diagram ....................... vii Dimensions & Weights .......................................... viii 1. Before Using This Product ................................ 1-1 Receiving Instructions.......................................... 1-1 Appearance .......................................................... 1-1 Handling the Product ........................................... 1-2 Carrying ............................................................... 1-3 Storage ................................................................ 1-3 Ratings Efficiency and Watts Loss ...................... 1-4 2. Installation Environment and Connection ....... 2-1 Operating Environment ........................................ 2-1 Installation Method .............................................. 2-1 Connection........................................................... 2-3 Basic Connection Diagrams ........................... 2-4 Connecting the Main Circuit and Ground Terminals ....................................... 2-8 Connecting the Control Terminals ................ 2-11 Terminal Configuration .................................. 2-15 Cable Size, Tightening Torque & Circuit Protection Rating .......................... 2-16 DC Link Reactor ........................................... 2-17 3. Operation ............................................................ 3-1 Inspection and Preparation Before Operation ..... 3-1 Operation Method ................................................ 3-1 Trial Run ............................................................... 3-1 4. Keypad Panel ..................................................... 4-1 Appearance of Keypad Panel .............................. 4-1 Operation From the Keypad Panel (LCD Screen, Level Structure) .................... 4-2 Normal Operation ........................................... 4-2 Alarm Modes .................................................. 4-2 Entering Data on the Keypad Panel .................... 4-4 Operation Mode .............................................. 4-4 Setting Digital Frequency ............................... 4-4 Switching to LED Digital Monitor .................... 4-5 Program Menu Screen .................................... 4-5

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Setting Function Data ..................................... 4-5 Checking Function Data ................................. 4-7 Monitoring Operating Status .......................... 4-7 I/O Check ........................................................ 4-8 Maintenance Information ................................ 4-9 Load Rate Measurement .............................. 4-10 Alarm Information ......................................... 4-11 Alarm History and Factors ............................ 4-12 Data Copy ..................................................... 4-13 Alarm Mode .................................................. 4-15 5. Function Selection ............................................. 5-1 Function Select List ............................................. 5-1 Alphabetical Function List ................................... 5-5 Function Explanation ........................................... 5-7 6. Protective Operations ........................................ 6-1 List of Protective Functions ................................. 6-1 Alarm Reset ......................................................... 6-2 7. Troubleshooting ................................................. 7-1 Activation of Protective Function ......................... 7-1 Abnormal Motor Rotation .................................... 7-5 8. Maintenance and Inspection ............................ 8-1 Daily Inspections .................................................. 8-1 Periodic Inspections ............................................ 8-1 Main Circuit Measurements ................................. 8-4 Insulation Test ...................................................... 8-5 Replacement Parts .............................................. 8-5 9. Warranty Parts and Service .............................. 9-1 In-Warranty Failure Checklist ............................... 9-2 10. Replacement Parts .......................................... 10-1 11. Specifications ................................................... 11-1 i

Page 6

Standard Specifications ..................................... 11-1 Common Specifications..................................... 11-3 Outline Dimensions ............................................ 11-5 Keypad Mounting Hole .................................... 11-12 12. RS485 Modbus RTU Serial Communication . 12-1 Transmission Specification ................................ 12-1 Connection......................................................... 12-1 Serial Interface Configuration ............................ 12-1 Modbus RTU Functions ..................................... 12-1 Drive function Code Access .............................. 12-2 Command and Monitor Data Registers ............. 12-2 Data Format Specification ................................. 12-4 Communication Errors ....................................... 12-8 13. Options .............................................................. 13-1 Built-in Options .................................................. 13-1 14. Electromagnetic Compatibility (EMC) ............ 14-1 General............................................................... 14-1 Recommended Installation Instructions ............ 14-1 ii

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Page 7

Safety Instructions Read this manual carefully before installing, connecting (wiring), operating, servicing, or inspecting the drive. Familiarize yourself with all safety features before using the drive. In this manual, safety messages are classified as follows:

WARNING

Improper operation may result in serious personal injury or death.

CAUTION

Improper operation may result in slight to medium personal injury or property damage.

Situations more serious than those covered by CAUTION will depend on prevailing circumstances. Always follow instructions.

Instructions on Use

WARNING • This drive is designed to drive a 3-phase induction motor and is not suitable for a single-phase motor or others, as fire may result. • This drive may not be used as a component of a life-support system or other medical device directly affecting the personal welfare of the user. • This drive is manufactured under strict quality control standards. However, safety equipment must be installed or the failure of this device may result in personal injury, property damage, or if there is a risk of accident.

Instructions on Installation

WARNING • Mount this drive on an incombustible material such as metal. There is a risk of fire. • Do not place combustible or flammable material near this drive, as fire may result.

CAUTION • Do not hold or carry this drive by its cover. Do not drop the converter, as injury may result. • Ensure that the drive and heat sink surfaces are kept free of foreign matter (lint, paper dust, small chips of wood or metal, and dust), as fire or accident may result. • Do not install or operate a damaged drive or a drive with missing parts, as electric shock or injury may occur.

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA iii

Page 8

Instructions on Wiring

WARNING • Connect the drive to power via a line-protection molded-case circuit breaker or fuse, as fire may result. Always connect a ground wire, as electric shock or fire may result. • A licensed specialist must perform all wiring work, as electric shock may result. • Turn off the power before wiring, as electric shock may result. • Wire the drive after installation is complete, as electric shock or injury may occur.

CAUTION • Confirm that the phases and rated voltage of this product match those of the AC power supply, as injury may result. • Do not connect the AC power supply to the output terminals (U, V, and W), as injury may result. • Do not directly connect a braking resistor to the DC terminals (P(+) and N(-)), as fire may result. • Ensure that the noise generated by the drive, motor, or wiring does not adversely affect peripheral sensors and equipment, as accident may result.

Instructions on Operation

WARNING • Be sure to install the cover before turning on the power (closed). Do not remove the cover while power to the drive is turned on. Electric shock may occur. • Do not operate switches with wet hands, as electric shock may result. When the retry function is selected, the drive may restart automatically after tripping. Design the machine to ensure personal safety in the event of restart. Accident may result. • When the torque limiting function is selected, operating conditions may differ from preset conditions (acceleration/deceleration time or speed). In this case, personal safety must be assured. Accident may result. • The STOP key is only effective when a function setting has been established. Install an independent emergency switch to disable the STOP key on the keypad panel when an operation is selected via the external signal terminal. Accident may result. • Operations can start up suddenly, after the alarm is reset, if there is a running signal input. Confirm that the running signal input is not present before resetting the alarm. Accident may result. • Do not touch drive terminals when energized, even if the drive has stopped. Electric shock may result.

CAUTION • Do not start or stop the drive using the main circuit power. Failure may result. • Do not touch the heat sink or braking resistor because they become very hot. Burns may result. • Since the drive can reach high speed operation easily, carefully check the performance of motor or machine before changing any speed settings. Injury may result. • Do not use the drive braking function for mechanical holding. Injury may result.

iv

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Page 9

Instructions on Maintenance, Inspection, and Replacement

WARNING • Wait a minimum of five minutes (30HP or less) or ten minutes (40HP or more) after power has been turned off (open) before starting inspection. Also confirm that the charge lamp is off and that DC voltage between terminals P(+) and N(-) does not exceed 25V. Electrical shock may result. • Only authorized personnel should perform maintenance, inspection, and replacement operations. Remove all metal jewelry such as watches and rings. Use insulated tools only. Electric shock or injury may result.

Instructions on Disposal

CAUTION • Treat as industrial waste when disposing of drive. Injury may result.

Instructions for UL/cUL Requirements

CAUTION • Hazard of electrical shock. Disconnect incoming power before working on this control. • Dangerous voltage exist until charge light is off. • Type1 - indoor use only. • Tightening torque and wire size for field wiring terminal are marked adjacent to the terminal or on the wiring diagram. • The drive shall be connected with Listed Class J Fuse or Circuit Breaker rated 600V as shown in the Table 2-3-5 (30 HP or less). • In case of using auxiliary control-power input, connect it by referring to the basic connection diagram (2-3-1). • Suitable for use on a circuit capable of delivering not more than 5000rms symmetrical amperes, for 230V (230V series), 480V (460V series) maximum up to 30HP; 42000rms symmetrical amperes 230V (230V series), 480V (460V series) maximum 40HP and above. • Use 60/75 °C CU wire only. • A Class 2 circuit wired with Class 1 wire (30HP or less). Use Class 1 wire only (40HP or more). • Field wiring connection must be made by a UL Listed and CSA Certified closed-loop terminal connector sized for the wire gauge involved. Connector must be fixed using the crimp tool specified by the connector manufacture. • Solid state motor overload protection is provided in each model.

Other Instructions

WARNING • Never modify the product. Electric shock or injury may result.

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA v

Page 10

Conformity to Low Voltage Directive in Europe

CAUTION • The contact capacity of alarm output for any fault (30A, B, C) and relay signal output (Y5A, Y5C) is 0.5A at 48V DC, 0.3A ≤ 250 VAC • The ground terminal (G) should be connected to ground. Use a crimp terminal to connect a cable to the main circuit terminal or drive ground terminal. • Where a residual-current protective device (RCD) is used for protection in case of direct or indirect contact, only a type B device is allowed on the supply side of this electrical equipment. Otherwise, another protective measure shall be applied such as separation of the electrical equipment from the environment by double or reinforced insulation or isolation of the electrical equipment and supply system by the transformer. • Use a single cable to connect the (G) drive ground terminal. Do not use two or more drive ground terminals. • Use a molded-case circuit breaker (MCCB) and magnetic contactor (MC) that conform to EN or IEC standards. • Operate the drive under over-voltage Category III conditions and maintain Pollution Degree 2 or better as specified in IEC664. To maintain Pollution Degree 2 or better, install the drive in a control panel structure (level NEMA 3 or higher) which is free from water, oil, carbon, dust, etc. • For the input-output wiring of the drive, use cable diameter and type as specified in Appendix C in EN60204. • To ensure safety, install an optional AC reactor, DC reactor, or external braking resistor as follows: 1) Install inside an IP4X cabinet or barrier if electrical parts are exposed. 2) Install inside an IP2X cabinet or barrier if electrical parts are not exposed. • In case of external cooling system, cover the drive rear side in order not to touch the main capacitor and braking resistor.

General Instructions For clarity, some figures in this manual may show the drive with covers and safety screens removed for explanation purposes. Do not operate the device until all such covers and screens have been replaced.

vi

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA