Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 2 of 35

Series One Programmable Controllers, Series One/One Plus User's Manual, pages 11 to 20

Pages 11 to 20 of 300

The original document is the PDF (40 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the GE Fanuc IC610CPU105A, GE Fanuc IC610CPU105C, Fanuc IC610CPU105A, GE IC610CPU105A, Fanuc IC610CPU105C and GE IC610CPU105C

Page 11

xi

Content GEK-90842

I/O Interface Cable Cross Reference

List I/O Module Catalog Numbers I/O Module Specifications and Wiring 115 V ac Input IC61OMDL125 230 V ac Input IC61OMDL127 115 V ac Isolated Input IC61OMDL126 24 V dc Sink Input (8 Circuits) IC61OMDLlOl 24 V dc Sink Input (16 Circuits) IC61OMDL106 24 V dc Sink Load Input (16 Circuits) with Removable Terminal Board IC61OMDL107 24 V ac/dc Source Input IC61OMDLlll 24 V ac/dc Source Input (16 Circuits) with Removable Terminal Board IC61OMDL112 115/230 V ac Output IC61OMDL175 115/230 V ac Isolated Output IC61OMDL176 24 V dc Sink Output (8 Circuits) IC61OMDL151 24 V dc Sink Output (16 Circuits) IC6lOMDL156 24 V dc Sink Output (16 Circuits) with Removable Terminal Board IC6lOMDL157 24 V dc 2 Amp Sink Output IC61OMDL153 24 V dc 2 Amp Sir&/Source Output IC61OMDL154 24 V dc Source Output IC61OMDL155 24 V dc Source Output (16 Circuits) with Removable Terminal Board IC61OMDL158 _ Relay Output (8 Circuits) IC61 OMDL180 Relay Output (16 Circuits) with Removable Terminal Board IC61OMDL182 24 V dc Input/Output (4 In/4 Out) IC61OMDL103 24 V dc Input/Relay Output (4 In/4 Out) IC61OMDL104 Thumbwheel InterfaceIC61OMDL105 High Speed CounterIC6lOMDLllO Module Location Interface to Field Devices Up/Down Counter Inputs Encoder Interface 1 Binary Coded Decimal (BCD) Output Counter Output Interface to User Logic Interface Function Definition Ouptut Logic Manual Mode Counter Mode Fitter Selection Fast Response I/OIC61OMDLll!5 Mode Selection Output Logic - Manual Mode Output Logic - Fast Response Mode I/O SimulatorIC61OMDL124 Analog InputIC61OMDL116

6-5 6-6 6-7 6-7 6-8 69 6-10 6111 6-12 6-13 6-14 6-16 6-17 6-18 6-19 6-20 6-22 6-23 6-24 6-26 6-27 6-29 6-31 6-33 6-36 6-39 6-41 6-42 6-43 6-44 6-46 6-48 6-49 6-50 6-53 6-53 6-53 6-55 6-56 6-58 6-58 6-58 6-61 6-62

Page 12

Content xii

GEK-90842

Introduction Hardware Features Power Requirements General and Electrical Specifications I/O Reference Definitions Sample Ladder Logic Analog Input Module Features Selection Of Operating Mode Analog OutputIC61OMDL166 Introduction Hardware Features Power Requirements General and Electrical Specifications I/O Reference Definitions Sample Ladder Logic Analog Output Module Features UL Listed Products 5-Slot Rack, UL ListedIC61OCHS 111 115 V ac Input Module, UL ListedIC61OMDL135 Relay Output Module, UL ListedIC61OMDL181 115 V ac Output Module, UL ListedIC61OMDL185 115 V ac Input Module (16 Circuits) with Removable Terminal Board IC61OMDL129 ,~ 115/230 V ac Output Module (8 Circuits) with Removable Terminal Board IC61OMDL179 CHAPTER

7.

8.

6-76 6-77

MAINTENANCE Introduction to Maintenance Procedures Troubleshooting Aids Basic Troubleshooting Procedure General Troubleshooting Procedure Replacement of Components Replacing a Rack Replacing a CPU Module Replacing I/O Modules Replacing the Battery Adding Memory Spare Parts and Components Fuse List

CHAPTER

6-62 6-62 6-62 6-62 6-63 6-64 6-66 6-66 6-67 6-67 6-67 6-67 6-67 6-68 6-69 6-70 6-71 6-72 6-73 6-74 6-75

7-1 7-1 7-1 7-2 7-3 7-3 7-3 7-4 7-4 7-5 7-6 7-7

APPLICATIONS Application

1 - One-Shots Application 2 - Flip Flop Application 3 - Event/I%ne Drum Application 4 - Cascaded Counters Application 5 - Coil 374, Power-Up One-Shot Description of Operation Application 6 - Coil 375, lOHz Clock Example 1: - Cumulative Timer Example 2: - Time of Day Clock Application 7 - Start/Stop Circuit

8-1

8-2 8-3 8-5 8-7 8-7 8-8 8-8 88 8111 e

Page 13

Content GEK-90842

Application 8 - High Speed Counter Applications Programmable Cam Switch Cut to Length Measuring a Random Length Sample Calculation Application 9 - Typical Shift Registers Shift Register References

APPENDIX A.

Related Documentation Introduction GEK-90477 Series One/Three Data Communications Manual GEK-90507 Remote I/O User’s Manual GEK-90825 Series Six PC I/O Link Local Module User’s Manual GEK90846Portable Programmer User’s Manual GEK-96662 Logicmaster 1 Programmer Documentor Manual GFK-0075 Logicmaster 1 Family Programming and Documentation Software User’s Manual

APPENDIX B. APPENDIX C. APPENDIX D.

Glossary of Terms Series One Family of Programmable Controllers Compatibility Guide 0 t her Programmable Controllers Series OneTMJunior Programmable Controller Series ThreeTMProgrammable Controller Available I/O Types Series SixTMProgrammable Controller Programming Optional Items Series SixTMPlus Programmable Controller

8-12 8-13 8-16 8-18 8-18 8-21 8-21 A-l A-l A-l A-l A-2 A-2 A-3 A-4 B-l Cl D-l D-l D-2 D-2 D-3 D-3 D-4 D-4

Page 14

Figures xiv GEK-90842

Figure

1-l l-2 2-l 2-2 2-3 2-4 2-5 2-6 2-7 2-8 29

2110 3-l 3-2 3-3 3-4 3-5 3-6 3-7 3-8 39 3-10 3-11 3-12 3-13 3114 4-l 4-2 4-3 4-4 4-5 4-6 4-7 4-8 49 4-10 4111 5-1 5-2 5-3 5-4 5-5 5-6 5-7 5-8 59 5110

Series One/Series One Plus Programmable Controllers Basic PC Block Diagram Typical Rack Typical Hardware Typical (5 Slot) Rack Typical (10 Slot) Rack Expander Cable Installation Programmer Mount Assembly Example of Relay Control Data Communications Unit Printer Interface Unit Prom Writer Unit Rack Mounting Dimensions for Proper Heat Dissipation Recommended Rack Grounding 10 Slot Rack, 19 Inch Mounting Dimensions I/O Expansion Cable Connection I/O Addressing Switches in Series One Plus 10 Slot Racks Examples of Rack Configuration Switch Setting Series One Plus Typical Installation Dimensions CPU Module Proper Module Insertion _ Proper Module Removal Typical Routing of I/O Wiring Pull Tab on Programmer Cable Installation of Programmer Cable Programmer Mount Assembly Programmer Features Series Logic (AND) Parallel Logic (OR) Volume Control Range Setting Printer Interface Unit Sample Ladder Diagram Printout Sample Boolean Printout Sample Outputs Used Table Printout Sample Outputs Used Table Printout (continued) PROM Writer Unit Features Timer/Counter Setpoint Unit I/O References Per Physical Placement for 5 and lo-Slot Racks CPU Scanning Sequence Programmer for Series One and Series One Plus Typical Ladder Diagram Sample Relay Logic (Motor Starter) Example of Normally Closed Inputs AND STR and OR STR COMCCtiOIlS

Push-Down Stack Storage Locations Push-Down Stack Logical Opcmtions AND SIR/OR STR Example Number 1 l-2 l-5 2-l 2-2 2-3 2-3 2-4 2-5 29 2-10 2-11 2112 3-2 3-3 3-4 3-4 3-5 3-6 3-7 3-8 3-9 39 3-11 3-12 3-12 3113 4-l 4-3 43 4-17 4-20 4125 4-26 4-27 4-28 4-29 4-32 59 5-15 5-16 5-17 5-21 5-22 5-23 5-24 5-24 5125

Page 15

Figures

XV

GEK-90842

5-11 5-12 5-13 5-14 5-15 5-16 5-17 5-18 5-19 5-20 5-21 5-22 5-23 5-24 5-25 5-26 5-27 6-l 6-2 6-3 6-4 6-5 6-6 6-7 6-8 69 6-10 6-11 6-12 6-13 6-14 6-15 6.16 6-17 6.18 6-19 6-20 6-21 6.22 6-23 6-24 6-25 6-26 6-27 6-28 6-29 Q30 6-31 6-32

AND SIR/OR STR Example Number 2 Example of Latching Logic Example of Master Control Relay Logic Multiple Master Control Relay Logic Sample Coil Disabler Logic Sample of Timer Logic Example of Timer Logic Example of Counter Logic Example of Counters Example of Extended Counters Illustration of Sequencer Operation Example of Sequencer Typical Sequencer Logic Typical Shift Register Example of Shift Register Example of Shift Register Logic Data Operation Block Diagram A. Typical I/O Module B. High Density Module With Removable Connector Typical I/O Terminal Configuration I/O Interface Cable Wiring List Example of 16 Circuit I/O References Wiring for 115 V ac Inputs Wiring for 230 V ac Inputs Wiring for 115 V ac Isolated Inputs Wiring for 24 V ac Sink Inputs I/O Points VS Temperature Wiring for 16 CIRCUIT, 25 V dc Sink Input Module J/O Points VS Temperature Wiring for 16 Circuit, 24 V dc Sink Load Inputs Wiring for 24 V ac/dc Inputs If0 Points vs Temperature Chart Wiring for 16 Circuit 24 V ac/dc Source Load Inputs I/O Points vs Temperature Wiring for 115/230 V ac Outputs I/O Points vs Temperature Chart Wiring for 15 V ac Isolated Outputs YO Points vs Temperature Chart Wiring for 24 V dc Sink Outputs x/O Points vs Temperature Wiring for 16 Circuit 24 V dc Sink Outputs YO Points vs Temperature Chart Wiring for 16 Circuit 24 V dc Sink Outputs I/O Points vs Temperature Chart Wiring for 24 V dc 2 Amp Sink Outputs UO Points vs Temperature Wiring of 24 V dc 2 Amp Sink/Source Output I/O Points vs Temperature Chart Wiring for 24 V dc Source Outputs I/O Points vs Temwrature

5-26 5-27 5-28 5-29 5-30 5-31 5-32 5-33 5-34 5-35 5-36 5-37 5-38 5-39 5-40 5-41 5-43 6-3 6-3 6-4 6-5 6-7 6-8 69 6-10 6-11 6-11 6-12 6-12 6-13 6-14 6-15 6.16 6.16 6-17 6-17 6.18 818 6-19 6-19 6-20 6-21 6-22 6-22 6-23 6-23 6-24 6-25 6126

Page 16

Figures xvi

GEIWO842

6-33 6-34 6-35 6-36

6-3’7 6-38 6-39 6-40 641 6-42 6-43 6-44 645 6-46 6-47 6-48 6-49 6-50 6-51 6-52 6-53 6-54 6-55 6-56 6-57 6-58 6-59 6-60 6-61 6-62 6-63 6-64 6-65 6-67 7-l 7-2 7-3 7-4 8-l 8-2 8-3 8-4 8-5

Wiring for 24 V dc Source Outputs Wiring for 8 Circuit Relay Outputs Wiring for 16 Circuit Relay Outputs Wiring for 24 V dc Inputs/Outputs Typical Wiring Diagram Sample 24 V dc INPUT/RELAY OUTPUT Circuits Wiring for Thumbwheel Interface Thumbwheel Interface Cable Wire List High Speed Counter Overview HSC Location in 5-Slot Rack HSC Connector Pin Definition Signal Direction UP/DOWN/RESET Input Circuit Encoder with RESET/MARKER Option Resetting Counter Once per Revolution of Encoder Shaft Encoder with RESET Option in Series with Home Limit Switch Such That Counter is Reset When Both Home Limit Switch and RESET/MARKER Pulse are Enabled Encoder With Limit Switch Resetting Counter and Photoelectric Cell Inhibiting the Counter Operation Sample BCD Output Circuit BCD Output Wiring Diagram User Load Wiring Diagram I/O and Counter Function Reference Chart Filter Selection with Dip Switch Module Reference NUMBER/LOGIC Symbol Definition Fast Response Module Logic Diagram Wiring for Fast Response I/O Module I/O Simulator Module Faceplate Analog Input Module Faceplate Analog Output Module Faceplate UL Listed 5-Slot Rack Wiring for UL Listed 115 V ac Input Module Wiring for UL Listed Relay Output Module Wiring for UL Listed 115V ac Output Module YO Points vs Temperature Chart Wiring for 115 V ac Inputs with Removable Terminal Board J/O Points vs Temperature Chart Wiring for 115/230 V ac Output with Removable Terminal Board Troubleshooting Indicators Battery Location and Connection Location of Extra Memory Socket Acccssury Kit for Series One/One Plus Typical One-Shot Timing Typical One-Shot Logic Typical Flip-Flop Timing Diagram Typical Flip-Flop Logic . Evenflime Drum Logic

6-26 6-28 6-30 6-32 6-34 6-35 6-37 6-38 6-40 6-41 642 6-43 6-43 6-44

6-44 6-45 646 6-47 6-48 6-49 6-55 6-57 6-59 6-60 6-61 6-66 6-70 6-72 6-73 6-74 6-75 6-76 6-76 6-77 6-77 7-2 7-4 7-5 7-7 8-l 8-l 8-2 8-2 8-3

Page 17

xvii

Figures GE&90842

8-6 8-7 8-8 89 8-10 8-11 8-12 8-13 8-14 8-15 8.16 8-17 8-18 8-19 8-20 8121

Sample Cascaded Counter Logic Typical Machine or Process Power-Up Inhibit Logic Cumulative Timer Sample 24 Hour Time Clock Logic Time Clock Resetting Fast Response Start/Stop Logic Worst Case Timing Diagram Application System Programmable CAM Switch Logic Timing Diagram Programmable CAM Switch Output No. 1 Logic Diagram Wiring Diagram Cut to Length Program Measuring a Random Length Shift Register Example Typical Shift Register Logic

8-6 8-7 8-8 89 8-10 8111 8-11 8-12 8-13 8-14 8-16 8-16 8-17 8-18 8-21 8-22

Page 18

Tables moo

XVIII

GEK-90842

Table l-l l-2 2-l 3-1 3-2 3-3 3-4 3-5 4-l 4-2 4-3 4-4 4-5 4-6 4-7 4-8 5-l 5-2 5-3 5-Q 5-5 5-6 5-7 5-8 6-1 6-2 6-3 6-4 6-5 6-6 6-7 6-8 6-9 6-10 6-11 6-12 6-13 6-14 6-15 6-16 6-17 7-1 c-1

Series One Family General Specifications Common PC Terminology Series One/Series One Plus Catalog Numbers Series One Installation Specifications CPU Option Settings Memory Size Units of Load Supplied by Rack Units of Load Used by Modules Error Code Definitions PC Operation Sequences Printer Interface Unit Specifications Printer Requirements Format and PC Selection Ladder Diagram Listing Error Messages and Definitions Boolean Listing Error Messages and Definitions Timer/Counter Setpoint Specifications Series One Model E/One Plus Basic Ladder Diagram Instructions Series One Execution Times Series One Plus Data Operation Instructions Series One/One Plus Instruction Groups Summary of References -Summary of I/O References for 8 Circuit Modules ^ Effect of Coil 376 (Output Disabler) Data Operation Function Numbers I/O Module Catalog Numbers Maximum Current vs Load Type for Relay Outputs Maximum Current vs Load Type for Relay Outputs Maximum Current vs Load Type for Relay Outputs Number of HSCs vs Discrete I/O Capacity Manual Mode Output Logic Truth Table Real Time Comparison Table for Preset Initially > Current count Real Time Comparison Table for Preset Initially < Current count Output State vs Real Time Comparison Status in Counter Mode Output Logic in Counter Mode Maximum Current vs. Load Type for Relay Outputs Operating Mode Selection Truth Table for Output in Fast Response Mode (S5 or S7 Have Been Enabled) Analog Input Module Specifications &!o Poh Iwinition Analog Output Module Specifications I/O Point Definition I/O Module Fuse List I/O Module Capability/Compatibility Guide l-4 l-8 2-5 3-1 3-8 38 3-14 3114 4-7 49 4-19 4-19 4-22 4-23 4123 4-33 5-2 5-3 5-4 5-7 58 5-10 5-29 5-46 66 6-27 6-29 6-34 6-42 6-53 6-53 6-54 6-54 6-55 6-57 6-58 6-58 6-63 6-63 6-68 6-68 7-7 c-3

Page 19

xix

Tables c-2 c3 cb D-l D-2 D-3 D-4

Summary of Progr amming References for Series One Family of Programmable Controllers Pv!r amming Function Compatibility Guide Examples of Valid System Configurations for I/O Points Series One Junior Capabilities Series Three PC Specifications Series Six CPU Capacities Series Six Plus Combined Memory Configurations

C-4 c5 C-6 D-l D-2 D-3 D-4

Page 20

This page is a scan with no text; see it in the PDF.