Page 87
PiC904X- CSM/CPU Central Service Module/Central Processing Unit
CSM/CPU Time-of-Day Clock
An internal clock IC maintains the current date and time. If power is off to the system, the battery maintains the clock. The application program and PiCPro can access this clock. Details are given in the Software manual.
Theory of Operation
The CSM/CPU module converts input power into DC power at voltages of +5V, +15 V, and -15 V and supplies them to the logic side of the modules in the rack. External power supplies are used for the field side of the I/O modules. Such supplies are not routed through the CSM/CPU, but they should all have the same power cut-off switch as the PiC9041. CAUTION The on/off rocker switch on the face of the CSM/CPU does not control the I/O power supplies. Always shut off power at the main disconnect switch before you replace a module in the system rack. With the CSM/CPU module, a key is supplied to protect the system from unauthorized start-ups. You can set up the PiC9041 hardware, power up and run the diagnostic tests, and even load a software application program without the system key. However, the application program will not be scanned until you turn the Run/Stop key on the CSM/CPU to the Run position. The CSM/CPU module does the following: • • • • • • •
•
Performs diagnostic tests. Checks the battery. Performs routine maintenance tasks. Executes the application program. Communicates with the I/O modules. Maintains communication with the workstation through the PiCPro port. Maintains communication with the user interface device through the user port. (Details for this communication depend partly on the type of interface device. Refer to the manual that comes with the device.) Provides peer-to-peer (ARCNET) communication and block I/O expansion capability (optional).
A.8 -7
Page 88
PiC904X- CSM/CPU Central Service Module/Central Processing Unit
Application in Flash
The 904X has a flash chip on board that allows you to load an application program into it. This is standard on the 904X and not the same as the optional Flash Memory System (FMS) that you can add. Having the application in the standard flash chip ensures that you will not lose the application if the battery fails. On power up, the application is transferred from the flash chip to RAM as it is when directly downloaded from PiCPro. To place the application in flash: 1.
Compile the application into a hex file in PiCPro.
2.
Use the SENDHEX utility (refer to the PiCPro Utilities Manual) to download the application into flash.
Even though you have placed an application in flash, you can still download and run a differenct application from PiCPro. However, when you cycle power on the PiC, the application in flash will always be placed into RAM. If you want to remove the application from FLASH so that it is not placed into RAM when you cycle power, use the SENDHEX utility to send the CLRFLASH.HEX file to the PiC. Replacing the Battery on the CSM/CPU
Follow the procedure below to replace a battery. 1.
After power has been applied to the CSM/CPU for at least five minutes, turn off power at the control cabinet main disconnect switch and at the CSM/CPU power switch. Unplug all connectors from the CSM/CPU.
2.
Remove the CSM/CPU module from the rack by pressing down the latch at the top and pulling it out.
3.
Use a static-free work surface if possible. Ground yourself using a properly grounded wrist strap before you open the case. These are standard precautions before handling any electronics component.
4.
Lay the CSM/CPU on the work surface with its label side up. Press the plastic tabs at the top and bottom of the module case toward each other and lift the side cover off WARNING Do not touch any of the capacitors. Do not touch the pins on any of the ICs; even with precautions against static you may destroy the circuitry.
5. A.8 -8
Use Figure A8-6 to locate the battery. Note how it is oriented.
Page 89
PiC904X- CSM/CPU Central Service Module/Central Processing Unit
Figure A8-6. Inside the CSM/CPU Module: Position of Battery
LEDs
Power Supply
BATTERY
Key
-
Battery Clip
+
6.
Use an insulated screwdriver to pry out one end of the battery clip. Remove the clip. Lift the battery out. Replace it with a 3V, 2/3A lithium battery. (See the specification sheet at the end of this section.) Replace the clip ensuring that it is latched.
7.
Close the case and insert the CSM/CPU in the rack. Reconnect all the cables. Turn on power and check the LEDs.
A.8 -9
Page 90
PiC904X- CSM/CPU Central Service Module/Central Processing Unit
Specification Table
Characteristic
CSM/CPU specifications
Functions
Supplies regulated DC power to the hardware modules installed in the rack. Executes the application program. Executes Diagnostics on the system and its modules. Communicates through the RS232 ports to external devices. Peer-to-peer communication with PiC900 family of controls (optional) Number of servo axes available at six update rates*
Models available PiC90 Model (for use with AC Power Source)
Part Number Speed
App RAM Mem Mem
User 8 4 2 1 .5 .25 Mem ms ms ms ms ms ms
9041 Standard w/o comm
502-04104-01
16 MHz
256K
128K
64K
12
9041 Standard w comm
502-04104-11
16 MHz
256K
128K
64K
9043 Turbo w/o comm
502-04125-01
32 MHz
256K
128K
64K
9043 Turbo w comm
502-04125-11
32 MHz
256K
128K
6
4
2
1
0
12
6
4
2
1
0
12
12
8
4
2
1
64K
12
12
8
4
2
1
6
4
2
1
0
PiC90 Model (for use with DC Power Source)
9041 Standard w/o comm
502-04110-00
16 MHz
256K
128K
64K
12
9041 Standard w comm
502-04110-10
16 MHz
256K
128K
64K
12
6
4
2
1
0
9043 Turbo w/o comm
502-04126-00
32 MHz
256K
128K
64K
12
12
8
4
2
1
9043 Turbo w comm
502-04126-10
32 MHz
256K
128K
64K
12
12
8
4
2
1
*The number of axes listed is typical for RATIO_GR, RATIOCAM, VEL_STRT, POSITION and DISTANCE move types. Applications which use time axes, servo tasks, RATIO_RL, M_LINCIR , or M_SCRVLC moves require more CPU time. Consult Giddings & Lewis for assistance if you want to exceed the number of axes in this chart.
AC power source
110-230 VAC, 47-63 Hz, 1A
DC power source
20 -30V DC, 3 A
Input connector
3-terminal plug connector, meets all specifications for touch safety in accordance with IEC 529 and DIN VDE 0470 part 1
Power output, total
A.8 -10
CSM/CPU 40 W (for AC power source) 30 W (for DC power source)
Page 91
PiC904X- CSM/CPU Central Service Module/Central Processing Unit
Individual outputs +5V @ + 15 V @ -15 V @ Battery
AC Power Source
DC Power Source
5.0 A 2.0 A .5 A
3A 1A .5A
1.2 Ah 3V, 2/3A lithium battery
CAUTION for Lithium Batteries
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batterries according to the manufacturers instructions. + 5 V supply monitor
Low trip point 4.50V min 4.75V max High trip point 5.50V min 5.94V max PWR LED goes off and PiC9041 shuts down
Flash memory system board (optional)
4 Megabyte FMS Board 502-03882-00 8 Megabyte FMS Board 502-03882-20
PiCPro port
Used to connect to the work station RS232 serial port, secured protocol Software selectable baud rate (300 to 57600 baud)
User port
Used to connect to a serial interface device RS232 serial port Supports RTS/CTS hardware handshaking Baud rates to 19.2 K
Peer-to-peer communications (optional)
Allows for communication between PiC90s and/or PiC900s (up to 255) A dedicated network controller supports peer-to-peer communications. Provides a twisted pair wire interface that is transformer isolated. Data is transferred serially at a rate of 2.5 megabits per second.
Block I/O expansion (optional)
Allows for communication between the PiC90 and block I/O modules (up to 77) The maximum distance between modules is 200 feet using shielded twisted pair wire
Time-of-day clock
Access via PiCPro or application program.
Clock tolerance
At 25° C, ±1 second per day Over temperature, voltage and aging variation, +2/-12 seconds per day
A.8 -11
Page 92
PiC904X- CSM/CPU Central Service Module/Central Processing Unit
Logic side power requirements (typical)
450 mA 650 mA 600 mA 800 mA 5 mA 10 mA
@ +5 V @ +5 V @ +5 V @ +5 V @+15 V @ -15V
40 mA @ -15V
5 µA @ +3 V
Operating temperature range
502-04104-00, 502-04110-00 502-04104-10, 502-04110-10 502-04125-00, 502-04126-00 502-04125-10, 502-04126-10 all 502-04104-00, 502-04110-00, 502-04125-00, 502-04126-00 502-04104-10, 502-04110-10 502-04125-10, 502-04126-10 (all) From the battery during power down
7° C to 55° C (45° F to 131° F)
Storage temperature range -40° C to 85° C (-40° F to 185° F) Humidity
5 to 95%, non-condensing
CE Marked
Conforms to Directives 73/23/EEC, 89/336/EEC, 92/31/EEC, 93/ 68/EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61000-4-3, ENV 50141, and ENV50204 • Electrical fast transients per EN61000-4-4 • Magnetic fields per EN61000-4-8 Refer to the EMC Guidelines for more information.
UL and C/UL Listed
File No. E126417 NRAQ Programmable Controllers
Physical size
2.4" wide x 12" high x 8.4" deep (including latch) 61 mm x 305 mm x 213 mm
Vibration (per IEC 68-2-6) 10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g) Shock (per IEC 68-2-27)
A.8 -12
Four shocks per axis (15g/11 msec)
Page 93
Appendix B - Communication Modules