Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 16 of 60

PiC900 Hardware Manual: B.4 - ETHERNET™ - TCP/IP Module

Pages 115 to 124 of 508, from PiC900 Hardware Manual

The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Giddings & Lewis 502-03550-02

Page 115

B.4 - ETHERNET™ - TCP/IP Module Introduction

The ETHERNET - TCP/IP module provides the PiC with Ethernet access and Internet connectivity. Connections for 10Base T, 10Base 2, and AUI (Attachment Unit Interface) are provided following the IEEE 802.3 specification. The data transfer rate is 10 Mbps. Applications can range from connecting several PiCs, connecting groups of PiCs and PCs, or connecting to a system that includes Internet access. At the end of this document is a partial list of Internet links to useful information about Ethernet and TCP/IP networking. The Remote Programmer Access key (future feature) will allow you to enable/disable PiCPro for Windows running over Ethernet. The DIAG LED goes on briefly while the diagnostic tests are running shortly after power is applied. Figure B4-1. Ethernet - TCP/IP Module Name of module

ETHERNET - TCP/IP

DIAG IN OUT GDLNK ETHERNET PREV COL

Diagnostic LED Ethernet Port LEDs

IN OUT RS232-1 IN OUT

RS232 COMM Ports

RS232-2

REMOTE PROGRAMMER ACCESS

Remote Programmer Access Key

Enable

(Future)

Disable

RS232 COMM Port 1

RS232 COMM Port 2

10Base T RJ-45 8-pin connector

AUI 15-pin D connector Door

10Base 2 BNC connector

B.4 - 1

Page 116

ETHERNET™ - TCP/IP Module

Connections

The PiCPro cable is used to make a connection between the PC and the PiC. 1.

Connect the PC to the RS232 Com 2 Port on the Ethernet - TCP/IP module to download the TCP/IP configuration file.

2.

Connect the PC to the PiCPro Port on the CPU to download the application LDO. Figure B4-2. PiC/PC Connections

PC

PiC CSM CPU

ETHER

2. 1.

PiCPro Port

You may choose one of three connection choices to set up your Ethernet - TCP/IP system.

B.4 - 2

1.

10Base T (10 Mbps, baseband, over twisted pair cable)

2.

AUI (Attachment Unit Interface, over shielded twisted pairs of wires with an overall shield covering these individual shielded wire pairs) NOTE: The 15-pin AUI connector does not have the traditional slide lock clip. Instead, #4-40 screw lock bushings are provided. If you want to use a standard transceiver cable, remove the slide lock posts from the male end of the cable. Plug the cable into the AUI connector and secure with #4-40 screws. A screw retainer kit with captivation clips is available from AMP (part number 2059801). A 20 inch ribbon cable is available from Giddings & Lewis for connecting to microtransceivers. It has the advantage of allowing the access door on the Ethernet - TCP/IP module to close.

3.

10Base 2 (10 Mbps, baseband, over thin coaxial cable)

Page 117

ETHERNET™ - TCP/IP Module

The table below summarizes the specifications (IEEE 802.3) for the Ethernet connections available on the Ethernet - TCP/IP module. Connections 10Base T

AUI

10Base 2

Category 3 or 5 (5 rec- 78 Ω shielded twisted- RG-58 thinnet coaxial ommended) pair transceiver UTP (unshielded twisted-pair) Shielded category 5 cable is optional. RJ-45

DB-15

BNC T connector

Terminator resistance Ω

NA

NA

50

Topology

Star bus

Point to Point

Bus

Type of Cable Connection

100 m (328’) between 50 m transceiver (TCP/IP module) and hub

Minimum of 0.5 m (23") between computers, maximum of 185 m (607’)

Maximum cable segment length

100 m (328’)

50 m (164’)

185 m (607’)

Computers per segment

NA

NA

30

Distance

B.4 - 3

Page 118

ETHERNET™ - TCP/IP Module

A typical 10Base T connection is shown below. Figure B4-3. Ethernet - TCP/IP 10Base T Connections

PiC CSM CPU

ETHER

10Base T Twisted Pair Segment

Hub

Node

Node

Node

Maximum segment length is 100 m (328’).

A typical AUI connection is shown below. Figure B4-4. Ethernet - TCP/IP AUI Connections

PiC CSM CPU

ETHER

AUI Cable (Transceiver Cable)

Maximum length 50 m (164’) Fiber Optic MAU (Transceiver or Microtransceiver) Fiber Optic Cable (To another computer or to an optical hub)

B.4 - 4

Page 119

ETHERNET™ - TCP/IP Module

A typical 10Base 2 connection is shown below. Figure B4-5. Ethernet - TCP/IP 10Base 2 Connections

PiC CSM CPU

ETHER

10Base 2 Coax Cable BNC T connector Minimum cable length .5m (23") 50 Ω Termination

MAU and connection to Coax Cable

Node

Node

Node up to 30 taps Node per segment

50 Ω Termination

Maximum segment length 185 m (607’)

The Ethernet Ports

There are three ethernet ports on the module as shown in Figure 4-3. One of these ports may be used to make your ethernet connections depending on the type of medium you are using. The 10Base-T port uses a RJ-45 style 8-pin connector using 100 Ω unshielded twisted pair category 3 or 5 (IEEE 802.3 section 14.4). The maximum length of the twisted pair cable segment is 100 m (328 ft.). NOTE: The connector is also suitable for shielded cable and will ground the shield to the chassis. The AUI connection uses a shielded D style 15-pin connector using 78 Ω shielded twisted pair cable (IEEE 802.3 section 7.4.3). The maximum length of the twisted pair cable is 50 m (164 ft.). The 10Base-2 (found on the bottom of the module) uses a BNC style coax connector and 50 Ω coax (IEEE 802.3 section 10.5). The maximum length of the coax cable is 185 m (607 ft.).

B.4 - 5

Page 120

ETHERNET™ - TCP/IP Module

The RS232 COMM Ports

There are two RS232 ports at the top of the module as shown in Figure 4-3. COMM 1 will be used for modem connections (future). COMM 2 is used to download your configuration file to the PiC. Pin #

Signal Name

2

Receive Data

RX

3

Transmit Data

TX

5

Ground

Gnd

7

Ready to send

RTS

8

Clear to send

CTS

LEDs

There are nine LEDs on the Ethernet - TCP/IP module in addition to the DIAG LED. They are located directly under the DIAG LED as shown below. Figure B4-6. Ethernet - TCP/IP LEDs

IN

B.4 - 6

DIAG

Diagnostic (yellow)

OUT GDLNK

Ethernet receiving data (green) Ethernet transmitting data (green) Ethernet 10Base-T good link (green)

PREV COL

Polarity reversed on 10Base-T receiver (yellow) Ethernet collision (yellow)

IN

OUT

IN

OUT

Com 1 receive data (green) Com 1 transmit data (green) Com 2 receive data (green) Com 2 transmit data (green)

Page 121

ETHERNET™ - TCP/IP Module

Theory of operation

The Ethernet - TCP/IP module contains a 32-bit processor to handle TCP/IP, PPP (future), and Ethernet protocols. It allows you to use the Ethernet network architecture and the TCP/IP standard set of protocols to communicate and access other modules, computers, or the Internet and its resources. The topology alternatives include linear bus and star bus. The CSMA/CD (Carrier Sense Multiple Access with Collision Detection) access method is used to regulate traffic on the main cable segment. The design is based on the IEEE 802.3 specifications. The data rate is 10 Mbps. The diagram below provides an overview. Figure B4-7. Ethernet - TCP/IP Overview

Ethernet - TCP/IP Module Software

Application Program TCP

Transmission Control UDP Protocol User Datagram Protocol

IP Internet Protocol

Ethernet - TCP/IP Module Hardware Ethernet

(FUTURE)

PPP

Point to Point Protocol

Network Interface

RS232

Ethernet Physical Mediums

Modem

Phone Line 10Base T

AUI

10Base 2

B.4 - 7

Page 122

ETHERNET™ - TCP/IP Module

Specification Table Characteristics

Ethernet - TCP/IP Module Specifications

Function

Provides the PiC with Ethernet access and Internet connectivity

Part number

502-04137-00

RS232 Port 1

Com Port 1 modem (future)

RS232 Port 2

Com Port 2 (for firmware and configuration loading)

10Base T

RJ-45 8-pin connector Maximum twisted pair length is 100 m (328 ft.).

AUI

15-pin D connector Maximum twisted pair length is 50 m (164 ft.).

10Base 2

BNC connector Maximum coax cable length is 185 m (607 ft.).

Logic side power requirements (typical)

+5V +15V -15V

Operating temperature range

7° C to 55° C (45° F to 131° F)

Storage temperature range

-40° C to 85° C (-40° F to 185° F)

Humidity

5 to 95%, non-condensing

@ 1250 mA @ 30 mA @ 30 mA maximum maximum

EMC Compliant Emissions Noise immunity

Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8KV air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information.

UL and C/UL Listed

File No. E126417 NRAQ Programmable Controllers

Physical size

1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm

Vibration (per IEC 68-2-6)

10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)

Shock (per IEC 68-2-27)

Four shocks per axis (15g/11 msec)

B.4 - 8

Page 123

ETHERNET™ - TCP/IP Module

Useful Internet Links http://www.3com.com/technology/tech_net/white_papers/ 500698.html#6 http://www.library.ucg.ie/Connected/Course/index.htm http://www.combsnet.com/cable/Basics/types.html http://www.jdltech.com/solutions/Standards_Terms.cfm http://www.jdltech.com/solutions/LAN_terms.cfm http://www.datatech.com/hot/w96_2.htm http://www.standards.ieee.org/catalog/IEEE802.3.html http://www.3com.com/nsc/glossary/main.htm http://www.alliedtelesyn.com/prd_tran.htm#microtrans http://www.lothlorien.net/collections/computer/ethernet_frames.html http://www.lantronix.com/htmfiles/mrktg/catalog/etntba.htm http://www.warehouse.com/datacomm/

B.4 - 9

Page 124

ETHERNET™ - TCP/IP Module

NOTES

B.4 - 10