Output 120/240V AC Module (32 or 16 points) Specification Table

Characteristic Function Part number

Output 120/240V AC module specifications Switches an external AC source to 32 or 16 loads 32 point M.1016.9076 (old # 502-03641-03) 16 point M.1016.8943 (old # 502-03551-03) AC source requirements Nominal 115 VAC, range 48 to 240V AC Field side connector 32 point 40-pin card edge connector, screw terminals 16 point 25-pin card edge connector, screw terminals Protection of logic circuits Optical isolation between the logic and field side, 2830 V AC Arrangement of outputs Four groups of 8 or 4 solid-state switches. Each group can use its own AC source, or one source can be daisy-chained. UL 508 spacing Fuse per group of 8 Fast-acting, UL rated 3A 250V AC metric fuse, 5 x 20 mm Maximum current per 2 A of continuous current for the group; group 32 point each switch is rated at .75 A continuous 16 point each switch is rated at 2 A continuous Indicator lights, output An LED for each output circuits Indicator light, module A DIAG LED turns OFF when the module passes its diagnostic tests at power-on. Indicator light, fuses A logic side LED lights to indicate a "blown fuse" condition when power is on to a group with a missing or open fuse. Switch characteristics Solid-state switches. Switch voltage, maxi32 point 1V AC @ .75A RMS mum ON 16 point 1.2V AC @ 2A RMS Surge current, maximum 20 A for 2 cycles, every 2 seconds; fuse blows if this is exceeded. Frequency 50 / 60 Hz. ± 5% Time delay on, maximum 1/2 cycle (turns on at zero voltage) Time delay off, maximum 1/2 cycle (turns off at zero voltage) Minimum load current 50 mA Leakage current in OFF 4 mA @ 120 VAC 6 mA @ 240V AC state, max Response to scan loss All outputs are reset to the OFF state (present) Logic side power require- 32 point 1 mA @ +5V ments (typical) 7 mA per energized output @ +5V 16 point 1 mA @ +5V 23 mA per energized output @ +5V

Giddings & Lewis

PiC900 Controls Motion Solutions Product Guide

67

Page 72

Output 120/240V AC Module (32 or 16 points) Field side power dissipa- 32 point 11.0 W tion, worst case 16 point 12.0 W Operating temperature 7°C to 55°C (45°F to 131°F) range Storage temperature range -40° C to 85°C (-40°F to 185°F) Humidity 5 to 95%, non-condensing EMC Compliant Emissions Operates with emissions below EN55011/ CISPR 11 Class A limits Noise immunity Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information. UL and C/UL Listed File No. E126417 NRAQ Programmable Controllers Physical size 1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm Vibration (per IEC 68-2- 10-57 Hz (constant amplitude .15 mm) 6) 57-2000 Hz (acceleration 2 g) Shock (per IEC 68-2-27) Four shocks per axis (15g/11 msec)

68

PiC900 Controls Motion Solutions Product Guide

Giddings & Lewis

Page 73

Input/Output TTL Module (24 inputs/8 outputs)

Input/Output TTL Module (24 inputs/8 outputs) The TTL (Transistor-Transistor Logic) module provides 24 optically isolated input points to monitor the status of TTL devices and 8 optically isolated output points to interface with TTL devices (or other 5V DC devices such as photoelectric sensors). The module can also be used as a feedback module to read devices like linear displacement transducers (TEMPOSONICS™, BALLUFF) or absolute encoders. These devices provide high speed, low voltage, low noise parallel digital signals. An external +5V DC is required for operation. The DIAG LED goes on briefly while the diagnostic tests are running.

TTL (24 inputs/8 outputs)

Name of Module Diagnostic LED

TTL

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

Giddings & Lewis

Screw terminal connector

Door

PiC900 Controls Motion Solutions Product Guide

69

Page 74

Input/Output TTL Module (24 inputs/8 outputs) Specification Table

Characteristics

TTL module specifications

Function

Monitors on/off states of 24 TTL inputs and controls on/off state of 8 TTL outputs.

Part number

M.1016.9291 (old # 502-03810-03)

Field side connector

40 pin card edge connector, screw terminals

External power supply

+5V ±5% 450 mA

Isolation

2500 VRMS between field side and logic side

Input characteristics

Vin high2.0 V minimum Vin low0.8 V maximum Iin high 1µA maximum Iin low - -0.65 mA maximum Minimum input pulse width1 µsec

Output characteristics

Vol -0.8V maximum @ Io = 10 mA (sinking) Voh -4.0V minimum @ Io = -10 mA (sourcing) Output turn on/off time - 300 nano sec Maximum cable length - 3 meters (approximately 10 feet)

Logic side power requirements (typical)

+5V @ 450 mA

Operating temperature range

7°C to 55°C (45°F to 131°F)

Storage temperature range

-40°C to 85°C (-40°F to 185°F)

Humidity

5 to 95%, non-condensing

70

PiC900 Controls Motion Solutions Product Guide

Giddings & Lewis

Page 75

Input/Output TTL Module (24 inputs/8 outputs)

EMC Compliant Emissions Noise immunity

Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information.

UL and C/UL Listed

File No. E126417 NRAQ Programmable Controllers

Physical size

1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm

Vibration (per IEC 68-2-6)

10-57 Hz (constant amplitude .15 mm) 57-2000 Hz (acceleration 2 g)

Shock (per IEC 68-2-27)

Four shocks per axis (15g/11 msec)

Giddings & Lewis

PiC900 Controls Motion Solutions Product Guide

71

Page 76

Input/Output 24V DC Sink Module (16/8 points)

Input/Output 24V DC Sink Module (16/8 points) The input section of the 24V DC I/O module converts DC signals from 16 devices into logic levels that the CPU can use. Each signal is converted into a corresponding logic 1 or 0 which is transmitted through the system bus to the CPU. An "on" signal is nominally 24 VDC, but can be any level between 14 and 30 volts. An "off" signal is any level below 5V. The wiring configurations may be sink or source. 16 LEDs indicate the logic state of each input. The output section of the module sinks voltage for eight individual loads from one DC power supply. The external supply is nominally 24 volts, but can be between 5 and 32 volts. Eight LEDs on the module indicate the logic state that drives each output. Another LED labeled FB turns on if the fuse in the active circuit is open or missing. The DIAG LED goes on briefly while the diagnostics tests are running.

24V DC Input/Output Module (16/8 sink pt)

IN/OUT

24 V DC

Name of Module Diagnostic LED Input LEDs “Fuse Blown” LED Output LEDs

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

72

Screw terminal connector

Door

PiC900 Controls Motion Solutions Product Guide

Giddings & Lewis

Page 77

Input/Output 24V DC Sink Module (16/8 points) Specification Table

Characteristic

Module specifications

Function

Monitors on/off states from up to 16 DC voltage inputs Sinks an external DC source to eight loads

Part number

M.1016.9350 (old # 502-03843-02)

Field side connector

40-pin card edge connector, screw terminals

Logic side power requirements (typical)

30 mA 7 mA per energized input 25 mA per energized output

Field side power dissipation (worst case at 32V DC)

3.6 W for inputs 4.0 W for outputs

Indicator lights, input/output circuits

An LED for each input/output

Indicator light, module

A DIAG LED turns OFF when the module passes its diagnostic tests at power-on

Indicator light, fuses

A logic side LED lights to indicate a "blown fuse" condition when power is on to the eight outputs when a fuse is missing or open

Operating temperature range

7°C to 55°C (45°F to 131°F)

Storage temperature range

-40°C to 85°C (-40°F to 185°F)

Humidity

5 to 95%, non-condensing

@ @ @

5V +5 V +5 V

EMC Compliant Emissions Noise immunity

Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information.

UL and C/UL Listed

File No. E126417 NRAQ Programmable Controllers

Physical size

1.6" wide x 12" high x 8.4" deep (including latch). 41 mm x 305 mm x 213 mm

Vibration (per IEC 68-2-6)

10-57 Hz (constant amplitude .15 mm) 57-2000 Hz (acceleration 2 g)

Shock (per IEC 68-2-27)

Four shocks per axis (15g/11 msec)

Giddings & Lewis

PiC900 Controls Motion Solutions Product Guide

73

Page 78

Input/Output 24V DC Sink Module (16/8 points)

Input section(16 pt) Input signals (exceed IEC standards) Nominal 24V DC on, 0V DC off UH Max (max. allowed voltage)

30V DC

IH Max (max. current @ 30 VDC)

7.5 mA

UL Min

Polarity independent

Guaranteed on

14V DC

IH Min (min. current @ UH Min)

2.8 mA

Guaranteed off

5V DC

IT Min (current allowed when off)

.75 mA

Time delay on

.75 mA

Time delay off

1 ms max

Protection of logic circuits

Optical isolation between the logic and field sides 4000 V peak

Input groups

Two groups of 8 IEC Type 1 inputs per NEMA Standard, ICS 3-1983, Table 3-304-2. UL 508 spacing

Output section (8 pt sink) DC source requirements

Nominal 24V DC; range 5 to 32V DC

Protection of logic circuits

Optical isolation between the logic and field side

Grouping of output

One grup of 8 solid-state switches UL 508 spacing

Fuse per group of 8 switches

Fast-acting UL rated 3 A 250V AC metric fuse, 5 x 20 mm

Maxiumum current per group

2 A of continuous current for the group; each switch is rated at .4 A continuous

Switch characteristics

Solid-state switches

Time delay on for resistive loads

30 µsec max

Time delay off for resistive loads

300 µsec max

Leakage current in off state

0.5 mA max

Switch voltage, maxiumum ON

1.8 VDC@ .4A

Surge current, maxiumum

2.5 A for 40 msec., every 2 seconds

Response to scan loss (present)

All outputs are reset to the OFF state

74

PiC900 Controls Motion Solutions Product Guide

Giddings & Lewis

Page 79

Input/Output 24V DC Source Module (16/8 points)

Input/Output 24V DC Source Module (16/8 points) The input section of the 24V DC I/O module converts DC signals from 16 devices into logic levels that the CPU can use. Each signal is converted into a corresponding logic 1 or 0 which is transmitted through the system bus to the CPU. An “on” signal is nominally 24V DC, but can be any level between 14 and 30 volts. An “off” signal is any level below 5V. The wiring configurations may be sink or source. 16 LEDs on the module indicate the logic state of each input. The output section of the module sources voltage for eight individual loads from one or two DC power supplies. Each external supply is nominally 24 volts, but can be between 5 and 32 volts. Eight LEDs indicate the logic state that drives each output. Another LED labeled FB turns on if the fuse in any active circuit is open or missing. The DIAG LED goes on briefly while the diagnostics tests are running.

24V DC input/output module (16/8 source PT) IN/OUT

24 V DC

Name of Module Diagnostic LED Input LEDs “Fuse Blown” LED Output LEDs

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

Giddings & Lewis

Screw terminal connector

Door

PiC900 Controls Motion Solutions Product Guide

75

Page 80

Input/Output 24V DC Source Module (16/8 points) Specification Table

Characteristic

Input/Output module specifications

Function

Monitors on/off states from up to 16 DC voltage inputs Sources an external DC source to 8 loads

New Part number

M.1016.9348 (old # 502-03842-02)

Field side connector

40-pin card edge connector, screw terminals

Logic side power requirements (typical)

30 mA @ +5V 7 mA per energized input @ +5V 23 mA per energized output @ +5V for outputs

Field side power dissipation worst case (at 32V DC)

3.6 W for inputs 6.4 W for outputs

Indicator lights, input/output circuits

An LED indicates the logic state of each input/output

Indicator light, module

The DIAG LED goes OFF when the module passes power-on diagnostic tests

Indicator light, fuses

A logic side LED lights to indicate a "blown fuse" condition when power is on to a group with missing or open fuse

Operating temperature range

7°C to 55°C (45°F to 131°F)

Storage temperature range

-40°C to 85°C (-40°F to 185°F)

Humidity

5 to 95%, non-condensing

EMC Compliant Emissions

Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information.

Noise immunity

UL and C/UL Listed

File No. E126417 NRAQ Programmable Controllers

Physical size

1.6" wide x 12" high x 8.4" deep (including latch). 41 mm x 305 mm x 213 mm

Vibration (per IEC 68-2-6)

10-57 Hz (constant amplitude .15 mm) 57-2000 Hz (acceleration 2 g)

Shock (per IEC 68-2-27)

Four shocks per axis (15g/11 msec)