Page 1 of J375 Modbus Adapter Data Sheet

Manual · Gould

J375 Modbus Adapter Data Sheet

Manual6 pagesPDF 643 KB

Data sheet for the Gould Modicon J375 Modbus adapter, the communications interface that connects a Micro 84 controller to Modbus.

Download the PDF643 KB

Covers · 4 models

The models it covers

Summary

What is in it

Gould's data sheet for the J375 Modbus Adapter, a communications interface module that connects the Micro 84 controller as a slave to a Modbus network. It describes the features, the case and mounting, the ports for the P370 programmer, an RS-232-C device and the Micro 84, the built-in power supply, LED indicators and DIP switches, the supported Modbus function codes, a typical network, the RS-232-C signals, transmission modes and parity, and the environmental and other specifications.

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Gould Modicon data sheets for the J375 Modbus Adapter, followed by the sheets for the J378 Modem and the Micro 84/P190 Programmer/Tape Loader cartridge. The J375 connects a Micro 84 controller to a Modbus network as a slave. The sheets give its ports, function codes, specifications and mounting notes, and show how the modem and the P190 programmer work with it.

Device
Modbus communications interface module that makes a Micro 84 controller a slave to a Modbus master p. 1
Ports
P370 Micro 84 Programmer, one RS-232-C device and the Micro 84 controller p. 1
Addressing
Up to 247 slaves on one system; address and system parameters set by dip switches at the rear p. 1
Power
Own built-in power supply with factory-selectable AC options; draws no power from the Micro 84 or the data bus p. 1
Indicators
Three LEDs: Run, Comm Active and Error p. 1
Function codes
Modbus function codes 1-8 and 15-19 p. 1
RS-232-C signals
TXD, RXD, RTS, CTS, DSR and DTR p. 2
Baud rates
75 to 19,200 p. 2
Dimensions (W x H x D)
1.63 x 10.50 x 5.50 in (41.40 x 266.70 x 139.70 mm) p. 2
Weight
2 lb 2.5 oz (0.978 kg) p. 2
Compatible modems
Modicon J378 modem plus many commercial modems p. 1
Micro 84 cable
6 ft long, interchangeable with the P370 cable p. 2
J378 modem
Attaches to the J375's right side; 4-wire twisted pair link using FSK, up to 19,200 bps p. 3
J378 cable
Four conductor, fully shielded twisted pair (Belden 8777); up to 32 drops p. 4

What this manual walks you through

  • Connecting a Micro 84 to a Modbus network as a slave p. 1
  • Setting the address and system parameters with the dip switches p. 1
  • Changing the dip switch parameters from the Modbus master with function code 19 p. 2
  • Adding a J378 modem for a 4-wire twisted pair network p. 3
  • Programming a Micro 84 from a P190 programmer through the J375 p. 5
  • Loading, recording and comparing Micro 84 programs on P190 tape p. 5

Good to know

  • When the Modbus port and the P370 port conflict, Modbus has priority and the P370 port only monitors. p. 1
  • Without a J378 modem, the J375 is installed as the last module in the I/O structure. p. 2
  • Attaching the J378 modem dedicates the adapter's RS-232-C port to the modem. p. 3
  • The J378 modem has no voice communication capability. p. 3
  • The J378 network's 15,000 ft maximum length can be increased when fewer than 32 slaves are used. p. 4

Questions this manual answers

What does the Gould J375 do?

It is a communications interface module that connects a Micro 84 controller to a Modbus network as a slave to a Modbus master. p. 1

How many slaves can a J375 Modbus system address?

Up to 247 slaves on one system, with the address set by dip switches at the rear of the case. p. 1

Does the J375 take power from the Micro 84?

No. It has its own power supply and needs no power from the Micro 84 or the data bus. p. 1

Which modem works with the J375?

The Modicon J378 modem, which attaches to the adapter's right side for 4-wire twisted pair networks; many commercial modems also work. p. 1, 3

The whole text · 1 part

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6

The file

Revision and size

RevisionPI-J375-001
PublisherGould Electronics
Pages6
PDF643 KB
TextText from the PDF itself.

The first pages · 3 of 6

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 6
Page 2
Page 2of 6
Page 3
Page 3of 6

More documents · 1