Page 1 of PanelMate Modicon Communication Driver Manual

Manual · AEG

PanelMate Modicon Communication Driver Manual

Manual49 pagesPDF 719 KB

Driver manual for connecting Cutler-Hammer PanelMate operator stations to Modicon PLCs, including setup of the J375 Modbus Adapter.

Download the PDF719 KB

Covers · 4 models

The models it covers

Summary

What is in it

Cutler-Hammer's manual for the PanelMate Modicon communication drivers. It explains installing drivers and downloading them to a PanelMate unit, then how to connect the operator station to Modicon PLCs over Modbus (ASCII or RTU) and Modbus Plus, and to the Modicon 410 Servo Controller: memory, possible configurations, cable diagrams, communication parameters, switch settings and word and bit references. It includes dipswitch settings for the Micro 84/J375 Modbus Adapter.

Its parts

  1. Introduction
  2. Modicon PLCs Using Modbus
  3. Modicon PLCs Using Modbus Plus
  4. Modicon 410 Servo Controller

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Eaton Cutler-Hammer manual (P/N 01-00454-03) for the PanelMate operator station drivers that talk to Modicon PLCs over Modbus and Modbus Plus and to the Modicon 410 Servo Controller. Its Modbus chapter describes the J375 Modbus Adapter for the Micro 84 PLC and how to set its dipswitches, along with cables, communication settings and word and bit references.

Read for this summary: pages 1 to 2 and 6 to 27 of 49.

J375 role
J375: Modbus Adapter, a communications interface module for the Micro 84 PLC p. 21
J375 ports
J375: one RS232C port for intelligent RS232 devices, plus ports for the Micro 84 controller and a P370 Micro 84 Programmer p. 21
J375 settings
J375: dipswitches at the rear of the case set address, stop bits, parity and baud rate; data bits fixed at 7 p. 21
J375 address
J375: switch set S1 sets the Micro 84 station address in binary, switch 1 lowest and switch 8 highest significance p. 21
J375 baud and parity
J375: switch set S2, switches 1 to 4 set baud rate, switches 5 and 6 set parity p. 21
J375 stop bits and mode
J375: S2 switch 7 ON for two stop bits, OFF for one; switch 8 OFF for ASCII, ON for RTU p. 21
Micro 84 read size
Micro84: up to 16 words per read cycle; 184 and 484 up to 25 contiguous words p. 24
Supported PLCs
Modicon Micro 84, 184, 384, 484, 584, 884 and 984, with Modbus ASCII or Modbus RTU mode drivers p. 12
Memory types
0XXX coils/discrete outputs, 1XXX discrete inputs (read only), 3XXX input registers (read only), 4XXX holding/output registers p. 12
Standard Modbus settings
7 data bits for ASCII or 8 for RTU, 1 stop bit (2 for 984-38X, 984-48X, 984-68X), 9600 baud, no parity p. 19
Interface and cable
RS232C; recommended maximum 50 cable feet; a standard Modicon W190 cable may be used p. 16
Modbus adapters
J375 for the Micro 84; J474 Communication Interface for the 484 PLC p. 21, 22
884 port 1 defaults
7 data bits (fixed), RTU mode, even parity, 1 stop bit, 9600 baud p. 20
Ladder logic
None needed in the PLC for the operator station interface p. 12

What this manual walks you through

  • Installing PanelMate drivers from the CD-ROM p. 8
  • Downloading Executive Firmware and a driver to a PanelMate unit p. 9
  • Building an RS232C cable between the operator station and a Modicon PLC or modem p. 16
  • Setting the J375 dipswitches for address, baud rate, parity, stop bits and mode p. 21
  • Setting 884 Modbus port parameters p. 20
  • Wiring the J474 30-pin connector to select baud rate, address, mode, stop bits and parity p. 22, 23
  • Writing Modicon word and bit references p. 24, 25, 26
  • Using the Maintenance Template p. 27

Good to know

  • With ASCII Modbus, the J375 parity must be set to odd or even. p. 21
  • PanelMate PC does not support Modbus RTU. p. 8
  • 884 models with 4-digit serial numbers cannot use ASCII mode, so RTU must be used. p. 20
  • The operator station cannot write to inputs or input registers. p. 24
  • Individual bit writes to holding/output registers are not allowed, except on the 984-785. p. 25

Questions this manual answers

What is the Modicon J375?

It is the Modbus Adapter for the Micro 84 PLC, giving one RS232C port for intelligent devices plus ports for the Micro 84 and a P370 programmer. p. 21

How do I set the J375 to RTU mode?

Turn switch 8 of switch set two (S2) ON for RTU; OFF selects ASCII. p. 21

How is the J375 station address set?

With switch set S1, as a binary number where switch 1 is lowest and switch 8 highest significance. p. 21

How long can the Modbus cable to a PanelMate be?

The link is RS232C and the recommended maximum is 50 cable feet. p. 16

Does the PLC need ladder logic for the PanelMate?

No, the driver generates the requests and the PLC needs no ladder logic for the interface. p. 12

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Communication Driver Manual1
  2. Preface2
    1. RESTRICTED RIGHTS LEGEND2
    2. TRADEMARKS2
    3. Support Services4
  3. Table of ContentsIntroduction5Installing Drivers6Downloading Drivers to a PanelMate Unit7Serial Transfer Cables7Modicon PLCs Using Modbus9Introduction10Memory10Possible Configurations11Direct11Multiple PLCs on a Single Modbus12Adapters and Cable Connecto5
  4. Introduction7
    1. Installing Drivers8
    2. Downloading Drivers to a PanelMate Unit9
  5. Modicon PLCs Using Modbus11
    1. Introduction12
    2. Memory12
    3. Possible Configurations13
    4. Adapters and Cable Connectors for Modicon PLCs15
    5. Cable Diagrams16
    6. Communications Parameters19
    7. Modicon Word and Bit References24
    8. Maintenance Access27
  6. Modicon PLCs Using Modbus Plus28
    1. Introduction29
    2. Memory29
    3. Possible Configurations30
    4. Cabling Diagrams33
    5. Communication Parameters35
    6. Configuration Entries35
    7. Switch Settings36
    8. Modbus Plus Word and Bit References38
    9. Unsolicited Writes to the Operator Station with Modbus Plus40
    10. Maintenance Access41
  7. Modicon 410 Servo Controller42
    1. Introduction43
    2. Driver Installation43
    3. Memory43
    4. Possible Configurations44
    5. Cabling45
    6. Communication Parameters46
    7. Modicon 410 Word and Bit References47
    8. Maintenance Access47
  8. Index48
  9. Reader Comment Card49
1 more line, from page 49 on
  1. Title: Modicon Communication Driver Manual 01-00454-0349

From the PDF’s own bookmarks.

The whole text · 6 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Pages 5 to 105-10
  3. Modicon PLCs Using Modbus, pages 11 to 1911-19
  4. Modicon PLCs Using Modbus, pages 20 to 2720-27
  5. Modicon PLCs Using Modbus Plus28-41
  6. Pages 42 to 4942-49

The file

Revision and size

RevisionP/N 01-00454-03, 2002
PublisherEaton Corporation, Cutler-Hammer Business Unit
Pages49
PDF719 KB