Manual · AEG
PanelMate Modicon Communication Driver Manual
Manual49 pagesPDF 719 KB
Driver manual for connecting Cutler-Hammer PanelMate operator stations to Modicon PLCs, including setup of the J375 Modbus Adapter.
Covers · 4 models
The models it covers
Summary
What is in it
Cutler-Hammer's manual for the PanelMate Modicon communication drivers. It explains installing drivers and downloading them to a PanelMate unit, then how to connect the operator station to Modicon PLCs over Modbus (ASCII or RTU) and Modbus Plus, and to the Modicon 410 Servo Controller: memory, possible configurations, cable diagrams, communication parameters, switch settings and word and bit references. It includes dipswitch settings for the Micro 84/J375 Modbus Adapter.
Its parts
- Introduction
- Modicon PLCs Using Modbus
- Modicon PLCs Using Modbus Plus
- Modicon 410 Servo Controller
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Eaton Cutler-Hammer manual (P/N 01-00454-03) for the PanelMate operator station drivers that talk to Modicon PLCs over Modbus and Modbus Plus and to the Modicon 410 Servo Controller. Its Modbus chapter describes the J375 Modbus Adapter for the Micro 84 PLC and how to set its dipswitches, along with cables, communication settings and word and bit references.
- J375 role
- J375: Modbus Adapter, a communications interface module for the Micro 84 PLC p. 21
- J375 ports
- J375: one RS232C port for intelligent RS232 devices, plus ports for the Micro 84 controller and a P370 Micro 84 Programmer p. 21
- J375 settings
- J375: dipswitches at the rear of the case set address, stop bits, parity and baud rate; data bits fixed at 7 p. 21
- J375 address
- J375: switch set S1 sets the Micro 84 station address in binary, switch 1 lowest and switch 8 highest significance p. 21
- J375 baud and parity
- J375: switch set S2, switches 1 to 4 set baud rate, switches 5 and 6 set parity p. 21
- J375 stop bits and mode
- J375: S2 switch 7 ON for two stop bits, OFF for one; switch 8 OFF for ASCII, ON for RTU p. 21
- Micro 84 read size
- Micro84: up to 16 words per read cycle; 184 and 484 up to 25 contiguous words p. 24
- Supported PLCs
- Modicon Micro 84, 184, 384, 484, 584, 884 and 984, with Modbus ASCII or Modbus RTU mode drivers p. 12
- Memory types
- 0XXX coils/discrete outputs, 1XXX discrete inputs (read only), 3XXX input registers (read only), 4XXX holding/output registers p. 12
- Standard Modbus settings
- 7 data bits for ASCII or 8 for RTU, 1 stop bit (2 for 984-38X, 984-48X, 984-68X), 9600 baud, no parity p. 19
- Interface and cable
- RS232C; recommended maximum 50 cable feet; a standard Modicon W190 cable may be used p. 16
- Modbus adapters
- J375 for the Micro 84; J474 Communication Interface for the 484 PLC p. 21, 22
- 884 port 1 defaults
- 7 data bits (fixed), RTU mode, even parity, 1 stop bit, 9600 baud p. 20
- Ladder logic
- None needed in the PLC for the operator station interface p. 12
What this manual walks you through
- Installing PanelMate drivers from the CD-ROM p. 8
- Downloading Executive Firmware and a driver to a PanelMate unit p. 9
- Building an RS232C cable between the operator station and a Modicon PLC or modem p. 16
- Setting the J375 dipswitches for address, baud rate, parity, stop bits and mode p. 21
- Setting 884 Modbus port parameters p. 20
- Wiring the J474 30-pin connector to select baud rate, address, mode, stop bits and parity p. 22, 23
- Writing Modicon word and bit references p. 24, 25, 26
- Using the Maintenance Template p. 27
Good to know
- With ASCII Modbus, the J375 parity must be set to odd or even. p. 21
- PanelMate PC does not support Modbus RTU. p. 8
- 884 models with 4-digit serial numbers cannot use ASCII mode, so RTU must be used. p. 20
- The operator station cannot write to inputs or input registers. p. 24
- Individual bit writes to holding/output registers are not allowed, except on the 984-785. p. 25
Questions this manual answers
What is the Modicon J375?
It is the Modbus Adapter for the Micro 84 PLC, giving one RS232C port for intelligent devices plus ports for the Micro 84 and a P370 programmer. p. 21
How do I set the J375 to RTU mode?
Turn switch 8 of switch set two (S2) ON for RTU; OFF selects ASCII. p. 21
How is the J375 station address set?
With switch set S1, as a binary number where switch 1 is lowest and switch 8 highest significance. p. 21
How long can the Modbus cable to a PanelMate be?
The link is RS232C and the recommended maximum is 50 cable feet. p. 16
Does the PLC need ladder logic for the PanelMate?
No, the driver generates the requests and the PLC needs no ladder logic for the interface. p. 12
Contents
Chapters and sections
Each line opens the PDF at its page.
- Communication Driver Manual1
- Preface2
- Table of ContentsIntroduction5Installing Drivers6Downloading Drivers to a PanelMate Unit7Serial Transfer Cables7Modicon PLCs Using Modbus9Introduction10Memory10Possible Configurations11Direct11Multiple PLCs on a Single Modbus12Adapters and Cable Connecto5
- Introduction7
- Modicon PLCs Using Modbus11
- Modicon PLCs Using Modbus Plus28
- Modicon 410 Servo Controller42
- Index48
- Reader Comment Card49
1 more line, from page 49 on
The whole text · 6 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file