Page 91

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

P3

P3

P1

P2

P1

「PATTERN 0-15」=8

P2

「PATTERN 0-15」=9

P3

P3

P1

P1

P2 「PATTERN 0-15」=10

「PATTERN 0-15」=11

P3

P3

P1

P2

P2 P1

「PATTERN 0-15」=12

P3

P2

「PATTERN 0-15」=13

P3

P1

P2 「PATTERN 0-15」=14

P1

P2 「PATTERN 0-15」=15

Fig.12.13 「PATTERN 0-15」 ②

12-10

Page 92

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

• 「ADDR STEP 0-255」 The number of steps to be skipped for developing position data addresses should be specified. If you input “0” for this item when “0” is specified for 「Z UPPER DATA」 explained above, the system automatically sets your input to “1.” And if you input “0” or “1” for this item when 「Z UPPER DATA」 setting is other than “0,” the system automatically sets to “2.”

12.1.4

END

(8)

When you press the message line.

(9)

To execute the calculation, press the key. When the calculation has been completed, “COMPLETED!!” is displayed.

key, “Calculate OK?” appears on the

ENTER

PATTERN

When there is a certain rule among a block of position data, the rule of the block (pattern) can be applied to create patterned blocks of data, by teaching the series of movements corresponding to the pattern to the robot system. EXAMPLE

A movement pattern where the Z-Axis position data increases 20mm per block is given below. Address 900 901 902 903

X 100 110 110 120

Y 150 160 180 180

Z 10 15 15 20

W 60 60 60 80

M 2 3 4 5

F 99 99 99 99

S 0 0 0 0

This pattern, when started from address 10 with the +20mm increment (or displacement) in Z-Axis position data for every additional block, can be developed as follows: Address 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025

X 100 110 110 120 100 110 110 120 100 110 110 120 100 110 110 120

Y 150 160 180 180 150 160 180 180 150 160 180 180 150 160 180 180

12-11

Z 10 15 15 20 30 35 35 40 50 55 55 60 70 75 75 80

W 60 60 60 80 60 60 60 80 60 60 60 80 60 60 60 80

M 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5

F 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99

S 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 93

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

The steps for developing these patterned data blocks are described below. (1)

Set the coordinates to “0 (world coordinates).” Refer to “2.4 Mode Select Operation.”

(2)

Teach to the robot system the original basic series of movements. At this time, teach the position from which the robot starts the operation.

(3)

Select a mode other than AUTO for the robot.

(4)

Press the

FUNC HIGH cal

+ 1 keys to display Fig. 12.1, Robot Calculate Mode screen. Select 「1.CALC.」 by pressing the cal 1 key.

(5)

When the screen display is as shown in Fig. 12.2, Calculate Mode screen, select 「4. PATTERN」.

(6)

Pressing the 4 key 「4. PATTERN」 displays the shaded section of the illustration below. To display the 「WORK NUMBER」 and the s.ed following items on the screen, press the up DOWN key to scroll.

PATTERN CALC MODE START ADDRESS 0000 END ADDRESS 0000 OPEN ADDRESS 0000 WORK NUMBER 000 MODE SELECT 000 X OFSSET 0000.000 Y OFSSET 0000.000 Z OFSSET 0000.000 W OFSSET 0000.000 Push END Key !!

Fig.12.14 PATTERN (7)

Input data. Inputting method is the same for all the items. To input, ④ Enter the value to be set. ENTER

⑤ Confirm that the data to be set is correct and press the key. The confirming message “ENTER OK?” appears on the message line and a buzzer sound. ⑥ Confirm again that the value to be set is correct. Then press the ENTER key for the second time. The data setting has been completed. The entry items are described below. •

「START ADDRESS」 Specify the first address of the block the pattern of which will be developed. In the case of the example on the previous page, the address is 900.

12-12

Page 94

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS •

「END ADDRESS」 Specify the last address of the block the pattern of which will be developed. In the case of the example on previous page, the address is 903.

•

「OPEN ADDRESS」 Specify the first address at which the pattern is opened and developed. In the case of the example on previous page, the address is 10.

•

「WORK NUMBER」 Specify the number of times the pattern is repeated. In the case of the example on previous page, the number is 4.

•

「MODE SELECT」 Select a value to select the system parameter used for display offset. Currently only “DISPLAY OFFSET 1” is available. 1: DISPLAY OFFSET 1 2: DISPLAY OFFSET 2 3: DISPLAY OFFSET 3 When a value other than those given above is specified, the system will use the data for “DISPLAY OFFSET 1” as the offset data.

•

「X OFFSET」 You can specify an offset value (increment or displacement) on the X-coordinate. Specify the value when the pattern has such regular increment/difference along the X-Axis. In the case of the example on previous page, the value is 0.

•

「Y OFFSET」 You can specify an offset value (increment or displacement) on the Y-coordinate. Specify the value when the pattern has such regular increment/difference along the Y-Axis. In the case of the example on previous page, the value is 0. 「Z OFFSET」 You can specify an offset value (increment or displacement) on the Z-coordinate. Specify the value when the pattern has such regular increment/difference along the Z-Axis. In the case of the example on previous page, the value is 20.

•

•

12.2

「W OFFSET」 You can specify an offset value (increment or displacement) on the W-coordinate. Specify the value when the pattern has such regular increment/difference along the W-Axis. In the case of the example on previous page, the value is 0. END key. “Calculate OK?” appears on the message line.

(8)

Press the

(9)

To execute the calculation, press the key. When the calculation has been completed, “COMPLETED!!” is displayed.

ENTER

Offset (OFFSET) Currently this function is not used for the system.

12-13

Page 95

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

12.3

Memory Data (MEMORY) Currently this function is not used for the system.

12.4

DISPLAY OFFSET Automatic Calculation Automatically calculates the value for 「DISP.X*」, 「DISP.Y*」, 「DISP.W *」, and 「DISP.R*」 of the System Parameter, 「OFFSET」→「DISPLAY OFFSET*」 group. The value for 「DISP. Z*」 is not calculated.

Currently this function is not used for the system. (1)

Set the coordinates to “0 (world coordinates).” Refer to 2.4, “Mode Select Operation.”

(2)

Teach following two points to the robot. P1 : Origin point on the display. P2 : The point which P1 move toward to P2 direction on X coordinates.

The addresses for P1 and P2 must be serial. Always teach P1-P2 in this order.

Y x y

P2

P1 X X-Y : Robot base coordinates x-y : Coordinates which have point P1 as the origin and P2 direction as x-Axis coordinates.

Fig.12.15 DISPLAY OFFSET (3)

Select a mode other than AUTO for the robot.

12-14

Page 96

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

(4)

Press the

FUNC HIGH cal

+ 1 keys to display Fig.12.1, Robot Calculate Mode screen. Select 「4. DISP」 by pressing the shows as following figure. DISP.OFF. 1.DISPLAY 2.DISPLAY 3.DISPLAY s.ed 4 key, and display

CALC.MODE 1 2 3

Fig.12.16 DISP (5)

(6)

Select the item which you wish to calculate from the DISPLAY OFFSET group. cal 1

: 1. DISPLAY 1 task 2

: 2. DISPLAY 2 mot 3

: 3. DISPLAY 3

Displays the shaded section of the illustration below. To display the 「DISPLAY Y1」 and the following items on the screen, press the up DOWN key to scroll. DISP.OFF.1 CALC.MODE TEACH ADDRESS 0000 MODE SELECT 000 DISPLAY X1 0000.00 DISPLAY Y1 0000.00 DISPLAY Z1 0000.00 DISPLAY W1 0000.00 DISPLAY R1 0000.00 Push END Key!!

Fig.12.17 DISPLAY Following items are for System Parameter data display. Changing the data on the screen will be ignored. Refer to 19.3, “OFFSET” for details.

• 「DISPLAY X1」 Displays the System Parameter, 「OFFSET」→「DISPLAY OFFSET1」→「DISP.X1」. After the automatic calculation, the calculated value for 「DISPLAY X1」 is rewritten and displayed on the screen.

• 「DISPLAY Y1」 Displays the System Parameter, 「OFFSET」→「DISPLAY OFFSET1」→「DISP.Y1」. After the automatic calculation, the calculated value for 「DISPLAY Y1」 is rewritten and displayed on the screen.

12-15

Page 97

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

• 「DISPLAY Z1」 Displays the System Parameter, 「OFFSET」→「DISPLAY OFFSET1」→「DISP.Z1」.

• 「DISPLAY W1」 Displays the System Parameter, 「OFFSET」→「DISPLAY OFFSET1」→「DISP.W1」. After the automatic calculation, the calculated value for 「DISPLAY W1」 is rewritten and displayed on the screen.

• 「DISPLAY R1」 Displays the System Parameter 「OFFSET」→「DISPLAY OFFSET1」 →「DISP.R1」. After the automatic operation, the calculated value for 「DISPLAY R1」 is rewritten and displayed on the screen. (7)

Input data. Inputting method is the same for all the items. To input, ① Enter the value to be set. ENTER

② Confirm that the data to be set is correct and press the key. The confirming message “ENTER OK?” appears on the message line and a buzzer sound.

③ Confirm again that the value to be set is correct. Then press the ENTER key for the second time. The data setting has been completed. The entry items are described below.

12.5

•

「TEACH ADDRESS」 Specify the position data address for taught position P1.

•

「MODE SELECT」 Not used. Specify “0” for this value. END key. “Calculate OK?” appears on the message line.

(8)

Press the

(9)

key. When the To execute the calculation, press the calculation has been completed, “COMPLETED!!” is displayed.

ENTER

Setting Servo Parameters (SERVO) Servo parameters are properly adjusted before shipment according to the unit to be controlled. However, if the motor emits abnormal noise or hunting occurs during positioning operation after the shipment, readjust the parameters. The steps to readjust the parameters are as follows: (1)

Set the coordinates to “0 (world coordinates).” Refer to 2.4, “Mode Select Operation.”

(2)

Press the

FUNC HIGH cal

+ 1 keys to set the Teach Pendant in KEY-IN mode.

12-16

Page 98

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

(3)

Pressing the screen:

p.ed 5 key 「5. SERVO」 displays the following on the

SERVO PARAM.TUNE 1.A PARAM 2.B PARAM 3.Z PARAM 4.W PARAM 5.R PARAM 6.C PARAM

Fig.12.18 SERVO (4)

Press the numeric key corresponding to the parameter you want to adjust. cal 1

: “A PARAME”: A (X)-Axis task 2

: “B PARAME”: B (Y)-Axis mot 3

: “Z PARAME”: Z-Axis s.ed 4

: “W PARAME”: W-Axis p.ed 5

: “R PARAME”: R-Axis home 6

: “C PARAME”: C-Axis

If the operation above is attempted in a mode other than KEY-IN, the message “Mode Error” appears and the input will be ignored. (5)

Then, the shaded portion of the illustration below appears on the screen. To display the 「Sync. Time」 and the following items on up the screen, press the DOWN key to scroll. Here, A (X)-Axis screen is described as an example. A(X) SERVO PARAMETER Motor Code 072 Enc. Pulse 012 Enc. Type 001 Sync. Time 002 Func 0 000 Kp (rad/s) 025 Kff (%) 000 Kvp (Hz) 0100 Tvi (msec) 0020 TPCM (msec) 000 FLPF (Hz) 990 ICMLPF(Hz) 450 ICMBEF(Hz) 990 OVFDAT(pluse) 00256 In Pos(pluse) 00016 SILIM 120 Alarm 0000 Cpu Ver. 04110 Amp Code 004 ExPansion 5 00000 ExPansion 4 00000 ExPansion 3 00000 ExPansion 2 00000 ExPansion 1 00000

Fig.12.19 SERVO PARAMETER

12-17

Page 99

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS (6)

Input data. Inputting method is the same for all the items. To input, ① Enter the value to be set. ENTER

② Confirm that the data to be set is correct and press the key. The confirming message “ENTER OK?” appears on the message line and a buzzer sound.

③ Confirm again that the value to be set is correct. Then press the ENTER key for the second time. The data setting has been completed The entry items and the outlined description are given below. For details, refer to separated volume, “Robot Controller User’s Guide” of the controlling devices you are using. Table 12.1 SERVO Parameters Parameter

Standard Value

Motor Code Enc.Pulse Enc.Type Sync.Time

012 001 002

Func0

000

Kp(rad/s) Kff(%) Kvp(Hz) Tvi(msec)

025 000 0100 0020

TPCM(msec)

0000

FLPF(Hz) ICMLPF(Hz) ICMBEF(Hz)

990 450 990

OVFDAT(pulse)

00256

In Pos(pulse) SILIM Alarm Cpu Ver. Amp Code IILMF(%) IILMR(%) Expansion3 Expansion2 Expansion1

00012 120

00000 00000 00000 00000 00000 END key.

Description Motor code (Refer to APPENDIX D “Motor Code.”) Sensor division number code Sensor type code Synchronous frame cycle Servo amplifier/driver function select bit Position loop gain Feed forward gain Speed loop proportional gain Speed loop integration constant Position command low-pass filter constant Feed forward pass filter Current command low-pass filter Current command notch filter Position deviation over setting value In-position setting value Sequence current limit Not used CPU version Amplifier capacity code Normal revolution current limit Reversed revolution current limit Not used Not used Not used

Replacement No allowed basically Not allowed Not allowed Not allowed Allowed Allowed Allowed Allowed Allowed Allowed Allowed Allowed Allowed Allowed Allowed Allowed Not allowed Not allowed Not allowed Allowed Allowed Allowed Allowed Allowed

(7)

Press the

The message “Servo Tune OK?” appears.

(8)

To execute the calculation, press the key. When the calculation has been completed, “COMPLETED!!” is displayed.

ENTER

When initializing the system data, it also initialize the servo parameters. (Refer to Chapter 21, “Initializing System Data.”)

12-18

Page 100

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

12.6

Expanded Zone Assignment (BP/ZONE) The data specified here are valid only when an expanded interface i is used. The data are used to assign outputs to the remote register of the expanded interface. Total maximum eight points are added for the A, B (X, Y)-Axes area output ii and the base position output iii. (1)

Set the coordinate to “0 (world coordinates)” (Refer to 2.4, “Mode Select Operation.”)

(2)

Select a mode other than AUTO.

(3)

Press the HIGH + 1 keys to display Fig.12.1, Robot Calculate Mode screen. Select 「6. BP/ZONE」 on the screen when the screen

FUNC cal home display is as shown in Fig.12.1. Pressing the 6 key 「6. BP/ZONE」 displays the shaded section of the illustration below. To display the 「7. ZONE 7…..」 and the following items on the screen, press the up DOWN key to scroll.

EXT. ZONE/BP ASSIGN 1.ZONE 1 2.ZONE 2 3.ZONE 3 4.ZONE 4 5.ZONE 5 6.ZONE 6 7.ZONE 7 8.ZONE 8 9.INITIALIZE

Fig.12.20 BP/SERVO (4)

Press the numeric key corresponding to the function you wish to use. cal 1

: ZONE 1 task 2

: ZONE 2 mot 3

: ZONE 3 s.ed 4

: ZONE 4 p.ed 5

: ZONE 5 home 6

: ZONE 6 s.g 7

: ZONE 7 s.p 8

: ZONE 8 key 9

: INITIALIZE i

: This function becomes valid when you specify either "CC-Link" or "Device-Net" as the I/O type in the system configuration mode. The expanded interface allows reading and writing of position data and system data. For details, refer to the operation manuals of the individual interfaces. ii : Refer to the System Parameter, 「SET-UP」→「EXPANSION A」→「Base Pos Addr*」. iii : Refer to the System Parameter, 「SET-UP」→「EXPANSION B」→「AREA AX」, 「AREA BY」.

12-19