Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 11 of 22

580 Series Controller Teach Pendant Operation Manual, pages 101 to 110

Pages 101 to 110 of 217

The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Hirata H3335

Page 101

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

(5)

cal s.p

When one of the numeric keys 1 to 8 is pressed, the shaded portion of the illustration below appears. To display the 「LOWER up

(ZONE)」 and the following items on the screen, press the DOWN key to scroll. Here, the case of 「ZONE 1」 is described as an example. EXT. ZONE/BP 1 OUT TYPE [ NOT USE ] AXIS (ZONE) [ A(X) ] UPPER(ZONE) 0000.000 LOWER(ZONE) 0000.000 BS ADDR (BP) 0000 BS PLUSE(BP) 0000 Push END Key!!

Fig. 12. 21 EXT ZONE/BP1 (6)

When 「EXT. ZONE/BP1」 is displayed, specify ZONE data for desired items. io

For 「OUT TYPE」 and 「AXIS (ZONE)」, press the SEL key to select the value. For other items, steps for data input is following. ① Enter the value to be set. ENTER

② Confirm that the data to be set is correct and press the key. The confirming message 「ENTER OK?」 appears on the message line with a buzzer sound ③ Confirm again that the value to be set is correct. Then press the ENTER key for the second time. The data setting has been completed. The entry items are described below.

• 「OUT TYPE」 Specifies the type of output signal using ZONE/BP. Select one of the following: BASE POS : Outputs base position signal. ZONE : Outputs ZONE signal. NOT USE : Not used

• 「AXIS (ZONE)」 Use this item when the ZONE signal is selected in the above step. Specify the output axis.

• 「UPPER (ZONE)」 Use this item when the ZONE signal is used. Specify the upper limit value.

• 「LOWER (ZONE)」 Use this item when the ZONE signal is used in the above step. Specify the lower limit value.

• 「BS ADDR (BP)」 Use this item when the BASE POS signal is used.

• 「BS PULSE (BP)」 Use this item when the BASE POS signal is used. 12-20

Page 102

CHAPTER 12 AUTOMATIC CREATION OF POSITION DATA & PARAMETERS

(7)

key

When you press the 9 key (「9. INITIALIZE」) on the Fig.12.20, BP/SERVO screen, “ZONE/BP INIT OK?” appears on the message line. To initialize all of the data set for the above items, press the ENTER

12.7 key. For each of the following items, “0” is written.

Error Messages in Automatic Calculate Mode Table 12.2 Error Messages in Automatic Calculation Mode (Robot Calculate) Error Message P1-P2 Length Error P1-P3 Length Error R-Offset Data Error Initial Data Error Teaching Data Error Address Error Mode Error Axis Not Used

Incompleted!!

Possible Cause Distance between P1 and P2 is too short. Distance between P1 and P3 is too short. Rotary-offset value has been abnormal. Initial data is abnormal. Teaching data is abnormal. Address is abnormal. The selected mode is not KEY-IN, TEACH, nor CHECK mode. The setting for the axis, for which calculation is made, is “NOT USED.”

Normal calculation is not possible.

12-21

Action to Take Teach again. Teach again. Teach again. Initialize again. Teach again. Change the mode. Specify the proper value. Check if the set data and teaching points are appropriate. Then, specify correct data or teach again.

Page 103

CHAPTER 13 MEMORY CARD

CHAPTER 13

Memory Card

As a medium to store information in the controller, an optional memory card can be used. This chapter explains how to use memory cards and the commands.

13.1

Selecting the Function To select the memory card function, press the as shown below appears on the screen.

FUNC HIGH m.c

+ M.OUT keys. The display

MEMORY CARD 1.ALL-LOAD 3.EDIT 2.ALL-SAVE 4.UTIL 5.VERIFY

Fig.13.1 Memory Card

13.2

Basic Operation (1)

To select an item, use the numeric key corresponding to the item.

(2)

Characters in the [ ] can be changed by using the numeric keys.

(3)

File names are seven-digit numbers. Use these seven-digit numbers to specify or display file names.

(4)

Command execution with no memory card inserted in the controller causes an error.

io SEL key or

Files on a memory card are managed in a similar way as those on floppy discs used for personal computers. Therefore, be sure to format a NEW memory card prior to use.

13-1

Page 104

CHAPTER 13 MEMORY CARD

13.3

File Name List When saving information, you have to specify a name for the file using numbers to save it under the name. The valid range of file names under which you can save your files is 0000001 to 9999999. However, 1234500 up to 1234599 are reserved for the system to use in the ALL-LOAD mode or ALL-SAVE mode. The file name allocation is as shown below. Table 13.1 File Name Allocation File Name 0000001 : 1234499 1234500 : 1234509 1234510 1234511 1234512 1234513 : 1234519 1234520 1234521 1234522 1234523 : 1234529 1234530 1234531 1234532 1234533 : 1234539 1234540 1234541 1234542 1234543 : 1234599 1234600 : : : 9999999

Allocation Area

Description

File area for users

Not used. Robot 1 position data Robot 1 system data(SG,SP) Robot 1 servo parameter Not used. Robot 2 position data Robot 2 system data(SG,SP) Robot 2 servo parameter System reserved file area

Not used. Robot 3 position data Robot 3 system data(SG,SP) Robot 3 servo parameter Not used. Robot 4 position data Robot 4 system data(SG,SP) Robot 4 servo parameter Not used.

File area for users

13-2

Page 105

CHAPTER 13 MEMORY CARD

13.4

ALL-LOAD Mode(MEMCARD → ROBOT) In this mode, the system loads all the system data, servo parameters, and position data from 0 to 999 (for standard model) to the robot controller. Use this mode to load data, which have been saved on the memory card by using the ALL-SAVE mode (refer to 13.5, “ALL-SAVE Mode (ROBOT→ MEMCARD)” below), to the robot controller. The files to be loaded are 1234500 to 1234599. If the files saved in the ALL-SAVE mode are of wrong type, or there are missed files, an error is caused. (1)

When the screen display is as shown in Fig.13.1, Memory Card cal screen, select the 1 key 「1. ALL-LOAD」. The display changes as follows and a buzzer sounds. LOAD MEMORY CARD MEMCARD >> ROBOT ALL-LOAD OK ?

Fig.13.2 ALL-LOAD

(2)

13.5

ENTER

Then, press the key to start the loading operation. When the all the data have been normally loaded, “COMPLETED!!” is displayed and the screen goes back to the Memory Card screen shown in Fig.13.1.

ALL-SAVE Mode(ROBOT → MEMCARD) In this mode, all the system data, servo parameters, and position data from 0 to 999 (as standard) are saved. The information retained in the robot controller is saved onto the memory card. The pieces of the information are saved in the respective locations reserved for the system as described in the previous section 13.3, “File Name List.” (1)

When the screen display is as shown in Fig.13.1, Memory Card task screen, select the 2 key 「2. ALL-SAVE」. The display changes as shown below and a buzzer sounds. SAVE MEMORY CARD ROBOT >> MEMCARD ALL-SAVE OK ?

Fig.13.3 ALL-SAVE

(2)

ENTER

Then, press the key to start saving. When all the data have been normally saved, “COMPLETED!!” is displayed and the screen goes back to the Memory Card screen as shown in Fig.13.1.

13-3

Page 106

CHAPTER 13 MEMORY CARD

13.6

EDIT Mode In this mode, reading, writing, or deleting files saved on the memory card is possible. When the screen display is as shown in Fig.13.1, Memory Card screen, mot 3 select the key 「3. EDIT」. The display changes as shown below. FILE EDIT 1.FILE 2.LOAD 3.SAVE 4.COPY 5.DEL 6.DUMP 7.FIND

Fig.13.4 EDIT

13.6.1

FILE Command

With this command, files that are currently saved on the memory card are displayed. Press the below.

cal 1

「1. FILE」 key. The display changes as shown

FILES FILES TYPE [Position Data] Push END Key !!

Fig.13.5 FILE (1)

Use the files.

io SEL key or the numeric key to select the desired type of

* 0

: Position Data cal 1

: System Data task 2

: Memory Data mot 3

: ALL s.ed 4

: Servo Param p.ed 5

: Option Data

Optional functions and sequences vary depending on the model. When such optional functions and/or sequences are added, additional file types are included accordingly. (2)

“Files Type OK?” is displayed with a buzzer sound. Then, press the ENTER key. The names of the files that have been saved are displayed. 1234560 1234561

Pos Sys

File name

0024004 0000836 File type

File size

Fig.13.6 Memory Card Display

13-4

Page 107

CHAPTER 13 MEMORY CARD The file types are described below. Pos Sys

: Position data : System data (data for the System Generation and the System Parameter) Srvo : Servo parameters Opt : Optional data Main : Main program *) Sub : Sub-program *) Hand : Hand program *) Time : Timer data *) *) when HARL-U1 i is used (3)

When there are many files following those currently on display, press any key to display the rest of the files in sequence page by page.

(4)

When all the files have been displayed, “COMPLETED!!” appears and the screen goes back to the FILE screen shown in Fig. 13.5.

13.6.2

LOAD Command

With this command, specified files are loaded to the controller. When the screen display is as shown in Fig.13.4, EDIT screen, select the task 2 key 「2. LOAD」. The display changes as shown below. FILE LOAD FILE NAME 1234561 START ADDR 0000000 Push END Key !!

Fig.13.7 FILE LOAD (1)

Specify a file name in the space for FILE NAME. ① Enter the file name in the space next to FILE NAME. ② Confirm that the entered file name (specified data) is correct. ENTER key. The message “ENTER OK?” is Then, press the displayed with a buzzer sound. ③ Confirm again that the file name (specified data) is correct. Then press the

ENTER i key again to set the data.

: A simplified robot control programming language developed by our company. For more information, refer to separated volume,"HARL-U1 Operation Manual.”

13-5

Page 108

CHAPTER 13 MEMORY CARD

(2)

Specify a value for 「START ADDRESS」 for loading the file. However, the loading steps are different depending on the file type. When a file is saved, the file type is determined.

• Pos: When the file is a position data file Specify addresses of the robot, to which the position data of the saved file is to be loaded. The steps to specify the start address are the same as those for 「FILE NAME」. When the start address specified for 「START ADDR」 is within the address range i assigned to the robot, the position data are loaded to the specified addresses of the robot. When the number of position data to be loaded is more than the number of the specified addresses of the robot, the position data are loaded up to the maximum address limit assigned to the robot. When an address outside the address range is specified for 「START ADDR」, the position data are loaded to addresses saved on the memory card. The addresses saved on the memory card can be displayed with DUMP command. (Refer to 13.6.6, “DUMP Command.”)

• Sys: When the file is a system data file All the system data are loaded. This operation is skipped because specifying the range is not required.

• Mem: When the file is a memory data file Currently this function is not used for this system.

• Srvo: When the file is a servo parameter file Servo parameters are loaded. This operation is skipped because specifying the range is not required.

• Opt: When the file is an optional data file Currently this function is not supported. (3)

Press the

END key. The message “File Load OK?” appears. To execute the LOAD command, press the

ENTER key.

When the loading has been successfully completed, “COMPLETED!!” is displayed. Then, the screen goes back to the screen shown in Fig. 13.7, FILE LOAD.

i

: Specified by the System Generation, 「LIMIT」→「ADDRESS MAX」→「ADDRESS MAX」.

13-6

Page 109

CHAPTER 13 MEMORY CARD

13.6.3

SAVE Command

Use this command to save a specified information onto the memory card. When the screen display is as shown in Fig.13.4, EDIT screen, select the mot 3 key 「3. SAVE」. The shaded portion of the illustration shown below appears. To display the 「STOP ADDR」 and the following items on the screen, press the up DOWN key to scroll.

FILE SAVE TYPE [Position Data] FILE NAME 1234561 START ADDR 0000000 STOP ADDR 0000000 Push END Key !!

Fig.13.8 FILE SAVE

(1)

Specify the type (「TYPE」) of the file to be saved by using the key or numeric keys. * 0

: Position Data cal 1

: System Data task 2

: Memory Data mot 3

: Servo Param s.ed 4

: Option Data io SEL

When optional functions and/or sequences are added, such additional file types are included accordingly. (2)

Specify a file name in the space for 「FILE NAME」. ① Enter the file name in the space next to 「FILE NAME」. However, do not use 1234500 to 1234599, as they are the reserved file names for the system. ② Confirm that the entered file name (specified data) is correct. ENTER key. The message “ENTER OK?” is Then, press the displayed on the message line with a buzzer sound. ③ Confirm again that the file name (specified data) is correct. Then press the

ENTER

13-7 key again to set the data.

Page 110

CHAPTER 13 MEMORY CARD

(3)

Specify the range of the file to be saved. However, the steps to save the range are different depending on the file type.

• Pos: When the file is a position data file Specify an address in the space for 「START ADDR」 from which saving process starts, and a stop address for 「STOP ADDR」 at which the saving process ends. The steps to specify for 「START ADDRESS」 and 「STOP ADDRESS」 are the same as those for 「FILE NAME」. The start address, where the first data to be saved are located, will be written in the position data file as the 4-byte header of the file, leading the position data.

• Sys: When the file is a system data file All the system data are saved. No need to specify the range. This operation is skipped because specifying the range is not required.

• Mem: When the file is a memory data file Currently this function is not used for this system.

• Srvo: When the file is a servo parameter file Servo parameters are saved. No need to specify the range. This operation is skipped because specifying the value is not required.

• Opt: When the file is an optional data file Currently this function is not used for this system. (4)

Press the

END key. The message “File Save OK?” appears. To ENTER execute the SAVE command, press the key. When the saving has been successfully completed, “COMPLETED!!” is displayed. Then, the screen goes back to the screen shown in Fig.13.8, FILE SAVE.

13.6.4

COPY Command

With this command, a file on the memory card can be copied and stored as another file on the memory card. When the screen display is as shown in Fig.13.4, EDIT screen, select the as shown below.

s.ed 4 key 「4. COPY」. The display changes

FILE COPY SOURCE NAME 0000000 DEST. NAME 0000000 Push END Key !!

Fig.13.9 FILE COPY

13-8