The text of a manual · part 14 of 22
580 Series Controller Teach Pendant Operation Manual, pages 131 to 140
Pages 131 to 140 of 217
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Hirata H3335
Page 131
CHAPTER 16 ROBOT OPERATION
P0(Motion start) P1 P2 P28
P29 P30
P7
P4 P3
P5
P6
A9
P8
P10
P27 P11 P31(Motion completes)
P26
P12 P25
P24
P13
P17 P23
P22
P21
P19 P20
P18
P16
P14
P15
Fig.16.9 Example of Robot Operation
For the P1 and P30 in the above illustration, the same point should be specified.
Table 16.1 Position Program Point P0 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16
Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
M 02 04 82 86 81 81 86 81 81 81 81 81 81 86 81 81 86
Operation PTP Linear Linear Arc Linear Arc Arc Arc Linear Arc Linear
16-10
Point P17 P18 P19 P20 P21 P22 P23 P24 P25 P26 P27 P28 P29 P30 P31 P32 P33
Address 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 END
M 81 81 86 81 81 86 81 81 81 81 86 81 81 88 08
Operation Arc Linear Arc Linear Arc Arc Linear Arc Linear PTP
Page 132
CHAPTER 16 ROBOT OPERATION
16.4
Functions of M-Data and S-Code
16.4.1
List of M-Data Functions
There are three types of robot operations (PTP operation, pass PTP operation and CPC operation). Normally, each motion is specified by the M-data as shown below. Table 16.2 List of M-Data Function M-Data 0 1-29 30-39 40-49 50-59 60-79 80-81 82-89 90-99
Function No operation PTP operation PTP pass operation PTP slow-up PTP insertion operation PTP operation CPC arc interpolation CPC linear interpolation PTP operation
When M-data value is 0 (M-data= 0), the system automatically increments the address until M-data value becomes other than 0, and the given address does not operate.
16.4.2
List of S-Code Functions
Normally, S-codes are used to expand the functions of M-data. The contents of expanded functions are described below. Table 16. 3 List of S-code Functions S-code
Note
98
Moves only A, B, and Z-Axes.
97
Prohibits PULL-UP.
95
Enables insertion motion.
94
90 29 28
Enables slow-up motion. Enables insertion motion/ slow-up motion Verifies once for positioning. Moves only Y-Axis. Moves only X-Axis.
26
Moves data by offsetting.
25
Moves only Z-Axis relatively.
24
Moves only Z-Axis relatively.
23
Moves only Z-Axis relatively.
22
Moves only Z-Axis relatively.
93 i
Function
: Specified by the System Parameter menu (the
FUNC s.p HIGH + 8
16-11
Position to be moved to = current position + position data Position where Z-Axis is moved to = Z-Axis current position + value specified for 「Z MD OF.」 i by selecting 「SET-UP」→「EXPANSION B」→「Z MD OF」. Position where Z-Axis is moved to = Z-Axis current position - value specified for 「Z MD OF.」 by selecting 「SET-UP」→「EXPANSION B」→「Z MD OF.」 Position where Z-Axis is moved to = Z-Axis current position + Z-Axis data Position where Z-Axis is moved to = keys), 「SET-UP」→「EXPANSION B」→「Z MD OF.」
Page 133
CHAPTER 16 ROBOT OPERATION S-code
Function
21 20 18
Moves only Z-Axis. Moves only A, B, and W-Axes. Moves only W-Axis.
17
Moves only W-Axis relatively.
Note Z-Axis current position – Z Axis data Position where W-Axis is moved to = W-Axis current position + W-Axis data
When using S-codes 1 through 89, you have to specify 2 for 「INCHING SELECT」 by selecting from System Generation menu i 「ORIGIN」→ 「SET-UP SYSTEM」→「INCHING SELECT」 (「INCHING SELECT」=2). When a value has already been set for the 「INCHING SELECT」, add 2 to the value. When S-code setting is 26, 23, or 33, position data may not be specified depending on the 「AREA LIMIT」 ii setting. Also, negative values (-) may not be accepted.
16.4.3
Changes in M-Data and S-Code Functions Depending on System Generation Setting
The contents of the M-data and S-code functions change depending on the setting of the 「M DATA」 reached from System Generation menu 「ORIGIN」→「SET-UP SYSTEM」. (1)
When 「M DATA」 setting is 0-7 M-data specifies functions while S-codes are used to expand the functions.
(2)
When 「M DATA」 setting is 8 M-data is used as the MOUT signal so that it does not specify functions. Instead, S-codes succeed the functions of M-data. However, in this case, M = 00 “JUMP” and M =?? “END” function as they normally do.
FUNC i ii s.g
: Press the HIGH + 7 keys to go to this screen menu. : Refer to 「AREA LIMIT」 group reached from 「LIMIT」 in System Generation menu.
16-12
Page 134
CHAPTER 16 ROBOT OPERATION
Below are the tables listing the modified functions of M-data and S-codes depending on the setting of 「M DATA」 in the System Generation. Table 16. 4 「M DATA」 and M-data M DATA M-data 0 1-29 30-39 40-49 50-59 60-79 80-81 82-89 90-99
0-7 No operation PTP operation PTP pass operation PTP slow-up PTP insertion operation PTP operation CPC semi-circle interpolation CPC linear interpolation PTP operation
8
M-data is used as the MOUT signal so that it does not specify functions.
Table 16.5 S-codes with 「M DATA」=0-7
Table 16.6 S-codes with 「M DATA」=8
M DATA S-code 98
Moves only A, B, and Z-Axes.
M DATA S-code 90-99
97
Prohibits PULL-UP motion.
82-89
95
Enables slow-down motion.
80-81
94
Enables slow-up motion. Enables slow-up motion /slow-down motion. Verifies for positioning once. Moves only Y-Axis. Moves only X-Axis. Moves data by offsetting. Moves only Z-Axis relatively. Moves only Z-Axis relatively. Moves only Z-Axis relatively. Moves only Z-Axis relatively. Moves only Z-Axis. Moves only A, B, and W-Axes. Moves only W-Axis. Moves only W-Axis relatively.
60-79
93 91 29 28 26 25 24 23 22 21 20 18 17
0-7
50-59
8 Allows PTP operation. Enables CPC linear interpolation. Enables CPC circular interpolation. Allows PTP operation. Enables PTP insertion motion.
40-49
Enables PTP slow-up.
30-39 1-29 0
Enables pass PTP operation. Allows PTP operation. Disables any operation.
PTP allows gate motions and/or arch motions. When PTP is specified for a certain group of axes to move them simultaneously i, neither gate motions nor arch motions are allowed.
i
: Typical with S-code 98 or 20, PTP operation is allowed for only axes defined by the code.
16-13
Page 135
CHAPTER 16 ROBOT OPERATION
16.5
F-Code The F-code specifies the positioning speed in each motion of robot. It is the ratio (percentage) specified for the speed setting items of 「MOTION」 group in System Parameter menu i . The valid range is 00-99. The actual speed is described in the following equation. Actual speed = value set as system data × (F-code + 1)/100 For speed values, the system parameters are referred. The items referenced are below.
z During PTP operation; 「MOTION」→「AXIS SPEED」→「SPEED A,B(X,Y), W」, 「SPEED Z」 z During CPC operation; 「MOTION」→「AXIS SPEED」→「SPEED A,B(X,Y), W」→「CPC SPEED」 To enter an F-code, select either KEY-IN or TEACH mode. Pressing the local F key moves the cursor to the first character of the F-code, allowing you to enter a value.
i
: Press the
FUNC s.p HIGH + 8 keys to go to this screen menu.
16-14
Page 136
CHAPTER 17 SYSTEM DATA
CHAPTER 17 17.1
System Data
Outline System data are semi-fixed data required to operate robots, specifically they are the data intrinsic to robots used and data to optimize the robots accordingly with the system. It is not necessary to modify the data after the robots are incorporated into the system. However, incorrect or inappropriate values cause malfunctioning or failure of the robots. Therefore, before starting robot operation, always be sure to specify correct data and record such set values. There are two categories in system data. One is called System Generation (SG), the items of which varies depending on the model of the robot main unit and the type of controller. Check and identify the model of the robot main units and the type of the controller that you use to specify correct values as the System Generation data. Another is called System Parameters (SP), which may be changed to modify the robot operation or motions after the robots have been incorporated into the system. The data in each category are divided into groups, as shown below, based on their functional use. To specify or check data, select necessary items listed in each group. (1)
System Generation (SG)
• LIMIT • MAINTE • ORIGIN • ADJUST
: Limits areas. : Used for maintenance purposes. : Sets the system up. : Specifies intrinsic values of mechanical components; such values for adjustments.
• CAPABILITY : Contains specification data and rated values of mechanical components.
(2)
System Parameters (SP)
• MOTION • RESPONSE • OFFSET • SET-UP • REMOTE
: Determines operation and motion. : Specifies various data of axes to be moved. : Specifies offset values of position data to be displayed. : Expands the system. : Controls the ON-LINE mode.
17-1
Page 137
CHAPTER 17 SYSTEM DATA
17.2
Configuration of System Data The configuration of system data is shown below. LIMIT
System Generation (SG)
ADDRESS MAX AREA LIMIT
MAINTE
EXPANSION A EXPANSION B MAINTENANCE DATA
ORIGIN
SET-UP SYSTEM AXIS DIRECTION AXIS SELECT
ADJUST
AR TYPE ADJUST MB TYPE ADJUST
CAPABILITY
ROBOT CAPABILITY EXPANSION A
Fig.17.1 System Generation (SG) MOTION
System Parameters (SP)
MOTION AXIS SPEED CPC CONSTANT
RESPONSE
ACCEL INP PULSE RESPONSE
OFFSET
DISPLAY OFFSET 1 DISPLAY OFFSET 2 DISPLAY OFFSET 3
SET-UP
EXPANSION A EXPANSION B
REMOTE
MOTION SPEED/ACCEL/INPOS RESPONSE
Fig.17.2 System Parameters (SP)
17-2
Page 138
CHAPTER 17 SYSTEM DATA
17.3
Setting/Changing Data Before attempting to specify values, read Chapter 18, “Details of System Generation” and Chapter 19, “Details of System Parameters” thoroughly. Whenever a system data error occurs, be sure to perform “default copying (copying default values)” onto the system data first, and then specify the values and data to be set again. When these activities have been completed, turn ON the power again. The following operations can be used in any mode:
17.3.1
Procedure for System Data Entry (1)
Specify either System Generation or System Parameter. FUNC
When the data are of System Generation group, press the HIGH + keys. When the data are of System Parameter group, press the keys.
FUNC HIGH s.g 7 s.p
+ 8
SYSTEM GENERATION 1.LIMIT 2.MAINTE. 3.ORIGIN 4.ADJUST 5.CAPABILITY
Fig.17.3 System Generation Menu (2)
Select the desired group to be edited by pressing the corresponding numeric key.
The steps to change the value specified for 「STOP」 in 「SET-UP SYSTEM」, by selecting 「ORIGIN」 from the System Generation menu, are described as an example. The current value “STOP” will be changed to “PAUSE” in this example. FUNC HIGH s.g 7
(1)
Press the
(2)
Press the 3 key when System Generation menu is on display. The display changes as illustrated below.
+ keys to display System Generation menu.
mot
ORIGIN GROUP 1.SET-UP SYSTEM 2.AXIS DIRECTION 3.AXIS SELECT
Fig.17.4 ORIGIN Group Menu
17-3
Page 139
CHAPTER 17 SYSTEM DATA
(3)
Press the follows.
cal 1 key 「1. SET-UP SYSTEM」. The display changes as
ORIGIN-SET UP TRANSFER RATE [9600] ON-LINE SELECT 0 STOP SEL [ STATUS]
Fig.17.5 SET-UP DATA Screen① (4)
The cursor is placed on the first entry place of 「TRANSFER RATE」 up space. The item 「STOP」 is not displayed. Press DOWN key to scroll the screen to move the cursor to the entry space of 「STOP」. TRANSFER RATE [9600] ONLINE SELECT 0 STOP SEL [ STATUS] STOP [ STOP]
Fig.17.6 SET-UP DATA Screen② (5)
Change the value. io
Press the either SEL or the value “STOP.” (6)
cal 1 key to select “PAUSE” to change from
Set the value. ENTER
① Press the key. The message, “ENTER OK?” appears on the screen with a buzzer sound. ② Confirm the data entered is the correct value. ③ After the confirmation, press the
ENTER key again.
④ When you wish to cancel this data entry operation, press any key other than the (7)
ENTER key.
The screen scrolls back and the following display appears: ONLINE SELECT 0 STOP SEL [ STATUS] STOP [ PAUSE] STORE ADDRESS [CURR]
Fig.17.7 「ORIGIN」 Screen spd CAN
(8)
Press the 17.4.
(9)
Press the CAN key again to go back to the System Generation menu as in Fig. 17.3.
key to go back to the ORIGIN Group Menu as in Fig.
spd
17-4
Page 140
CHAPTER 17 SYSTEM DATA
When changing system data on a data screen, use the Teach Pendant as described below. seq
・Press the A key on the data screen. The cursor moves to the first data on the data screen. up
・Press the DOWN key to move the cursor down to the data on the line immediately below the current line. To move the cursor up to the data on the line immediately above the current line, press the illuminate 『SHIFT』 LED, and then press the up DOWN
SHIFT key to key.
READ
・When the key is pressed before the data setting operation after the data has been changed, the previous data is displayed instead of the newly specified data. spd
・ If the CAN key is pressed in the middle of data entry operation, the entry operation is skipped and the screen goes back to the group menu screen.
17.3.2
Changing Data
There are two ways to change data.
z When values are numerical numbers, press the desired numeric keys to change data.
z When values are in character forms, select the desired character form.
A value in a character form such as “STOP” can be selected by io pressing the SEL key to switch to the value. Also, as numbers are assigned to character-form values, you can select a character-form value by pressing the corresponding numeric key.
17.3.3
Number of Items on Display
The screen can display only four lines. But some group menus hold more items than can be displayed on the screen at one time. In such a case, up press the DOWN key to scroll the screen to display the items in the following pages in sequence. After the last item in the group is displayed, “ ... bottom ...” appears in the line below. This “ ... bottom ...” indicates the end of the group menu.
17.3.4
Screen Transition
In System Generation menu, there are five group menus and 12 data screens. The System Parameter menu holds five group menus and 15 data screens. When a group menu is displayed in either System Generation or System FUNC dec
Parameter menu, pressing the HIGH + INC keys changes the group menus in cycle. With 『SHIFT』 LED not illuminated, the group menus are displayed in numerical order. With 『SHIFT』 LED illuminated, they are displayed in the reversed numerical order. 17-5