Page 141
CHAPTER 17 SYSTEM DATA
「LIMIT」 group menu dec FUNC HIGH + INC keys
「MAINTE」 group menu
FUNC dec HIGH + INC dec FUNC HIGH + INC keys keys
「ORIGIN」 group menu dec FUNC HIGH + INC keys
SHIFT
「ADJUST」 group menu
When 『SHIFT』LED is OFF dec FUNC HIGH + INC
SHIFT keys
When 『SHIFT』LED is ON
「CAPABILITY」 group menu
Fig.17.8 Group Menu Cycle in System Generation In the same way, when a data screen is displayed, pressing the keys changes data screens in sequence. FUNC dec HIGH + INC key
「ADDRESS MAX」 data screen FUNC dec HIGH + INC
「AXIS DIRECTION」 data screen FUNC dec HIGH + INC key
「AREA LIMIT」 data screen dec FUNC HIGH + INC key
FUNC dec HIGH + INC
FUNC dec HIGH + INC key
FUNC dec HIGH + INC key
FUNC dec HIGH + INC key key key
「EXPANSION A」 data screen
When『SHIFT』 LED is OFF
SHIFT
When『SHIFT』 LED is ON
Fig.17.7 Data Screen Cycle in System Parameter
17.3.5 key
「ROBOT」 data screen
「SET-UP SYSTEM」 data screen
SHIFT key
「MB TYPE ADJUST」 data screen
「MAINTENANCE DATA」 data screen FUNC dec HIGH + INC dec FUNC HIGH + INC key
「AR TYPE ADJUST」 data screen
「EXPANSION B」 data screen FUNC dec HIGH + INC key
「AXIS SELECT」 data screen
「EXPANSION A」 data screen FUNC dec HIGH + INC
FUNC HIGH
Setting Default Values for System Data
Refer to Chapter 21, “Initializing System Data.”
17-6 dec
+ INC
Page 142
CHAPTER 18 DETAILS OF SYSTEM GENERATION
CHAPTER 18
Details of System Generation
The details of System Generation, which comprises a part of system data, are described.
18.1
LIMIT Group Data in LIMIT group are used to limit the position data and the working areas of programs to provide safety measures.
18.1.1
ADDRESS MAX (1)
「ADDRESS MAX」
• Number of entry digits : 4 • Valid range : 0 to 9999 • Minimum unit :1 • Standard setting : 999 Specifies the maximum number of position addresses that the program uses. The valid setting range is the value set for 「MAX POSITION」 i in the system configuration. However, when only a small number of positions are required in an actual application, the maximum number of position addresses can be limited. With this limitation, when an address number greater than the specified value is entered or input externally, “ADDRESS ERROR” is displayed on the message line indicating the error has resulted.
18.1.2
AREA LIMIT
Data in this group limit the working area of each axis. Input the either angle or stroke value depending on the unit type. (1)
「UPPER LMT A」
(2)
「LOWER LMT A」
• Number of entry digits : 7 • Valid range : -7999.999 to 7999.999 • Minimum unit : ±0.001 • Standard setting : 「UPPER LMT A」 : 1000 「LOWER LMT A」 : 0 As a safety measure, the software limits the maximum and minimum working areas of A-Axis (X-Axis).
: Refer to 20.4, “Assigning Motors to Robot Axes." i
18-1
Page 143
CHAPTER 18 DETAILS OF SYSTEM GENERATION
① For SCARA (horizontal multi-articulated) robot: The value indicates an angle of B-Axis, with its origin at the time of A-CAL as the reference. The relationship among the data is as shown below. 0 ≦ LOWER LMT B < UPPEER LMT B ≦maximum working area of B-Axis The maximum working area of A-Axis is the operating area mechanically limited and varies depending on the unit type. (e.g., AR-C270’s maximum working area of A-Axis = 205°) When the working area of A Axis is limited with the following settings: 「UPPER LMT A」= 200° 「LOWER LMT A」= 130° if you attempt to specify, in KEY-IN or TEACH mode, a position outside the shaded area in the illustration for A-Axis, “AREA ERROR” is displayed indicating the error. When area limiting is not required, set as follows: 「UPPER LMT A」= the maximum working area of A-Axis 「LOWER LMT A」= 0
200 130°
A-CAL position
Fig.18.1 Area Limitation for A-Axis ② For Cartesian robot: Sets the operating stroke value of X-Axis for 「UPPER LMT A」. When area limiting is not required, set as follows: 「UPPER LMT A」= the distance of operating stroke of X-Axis 「LOWER LMT A」= 0
18-2
Page 144
CHAPTER 18 DETAILS OF SYSTEM GENERATION (3)
「UPPER LMT B」
(4)
「LOWER LMT B」
• Number of entry digits : 7 • Valid range : -7999.999 to 7999.999 • Minimum unit : ±0.001 • Standard setting : 「UPPER LMT B」: 1000 「LOWER LMT B」: 0 As a safety measure, the software limits the maximum and minimum working areas of B-Axis (Y-Axis). ① For SCARA(horizontal multi-articulated) robot: The value indicates an angle of B-Axis, with its origin at the time of A-CAL as the reference. The relationship among the data is as shown below. 0 ≦ LOWER LMT B < UPPEER LMT B ≦maximum working area of B-Axis The maximum working area of B-Axis is the operating area mechanically limited and varies depending on the unit type. (e.g., AR-C270’s maximum working area of B-Axis = 285°) If you attempt to specify, in KEY-IN or TEACH mode, a position outside the shaded area in the illustration for B-Axis, “AREA ERROR” is displayed indicating the error. Below is the example diagram where the working areas of A and B-Axes are limited with the following settings: 「UPPER LMT A」=200° 「LOWER LMT A」= 130° 「UPPER LMT B」= 270° 「LOWER LMT B」= 20° 270° 20° A-CAL position
20° 270°
Fig.18.2 Area Limitation for B-Axis When area limiting is not required, set as follows: 「UPPER LMT B」= the maximum working area of B-Axis 「LOWER LMT B」= 0 18-3
Page 145
CHAPTER 18 DETAILS OF SYSTEM GENERATION ② For Cartesian robot: Sets the operating stroke value of the Y-Axis for 「UPPER LMT B」. When area limiting is not required, set as follows: 「UPPER LMT B」= the stroke of Y-Axis 「LOWER LMT B」= 0 (5)
「UPPER LMT Z」
(6)
「LOWER LMT Z」
• Number of entry digits : 7 • Valid range : -7999.999 to 7999.999 • Minimum unit : ±0.001 • Standard setting : 「UPPER LMT Z」: 400 「LOWER LMT Z」: 0 The maximum working stroke of Z-Axis is limited. If you attempt to specify, in KEY-IN or TEACH mode, a position outside the limited area for Z-Axis, an error is caused. For example, when 100mm stroke of Z-Axis suffices the required work even though the Z-Axis has 150mm stroke, set as follows taking safety into account: 「UPPER LMT Z」= 100 When area limiting is not required, set as follows: 「UPPER LMT Z」= the stroke of Z-Axis 「LOWER LMT Z」= 0 (7)
「UPPER LMT W」
(8)
「LOWER LMT W」
• Number of entry digits : 7 • Valid range : -7999.999 to 7999.999 • Minimum unit : ±0.001 • Standard setting : 「UPPER LMT W」: 720 「LOWER LMT W」: 0 The maximum working area of W-Axis is limited. If you attempt to specify a Z-Axis value outside the limited area (for W-Axis) in KEY-IN or TEACH mode, an error is caused. When the W-Axis is the rotation Axis, an angle should be entered, while a length in “mm” should be entered when the axis is linear.
18-4
Page 146
CHAPTER 18 DETAILS OF SYSTEM GENERATION (9)
「UPPER LMT R」
(10) 「LOWER LMT R」
• Number of entry digits : 7 • Valid range : -7999.999 to 7999.999 • Minimum unit : ±0.001 • Standard setting : 「UPPER LMT R」: 720 「LOWER LMT R」: 0 The maximum working area of R-Axis is limited. If you attempt to specify a Z-Axis value outside the limited area (for R-Axis) in KEY-IN or TEACH mode, an error is caused. (11) 「UPPER LMT C」 (12) 「LOWER LMT C」
• Number of entry digits : 7 • Valid range : -7999.999 to 7999.999 • Minimum unit : ±0.001 • Standard setting : 「UPPER LMT C」: 720 「LOWER LMT C」: 0 The maximum working area of C-Axis is limited. If you attempt to specify a Z-Axis value outside the limited area (for C-Axis) in KEY-IN or TEACH mode, an error is caused.
18.2
MAINTENANCE Data in this group sets data used for maintenance. Unless otherwise required, enter “0” (default value) for each item.
18.2.1
EXPANSION A
Currently not used」. (1)
「CPC GAIN Z」
(2)
「CPC GAIN W」
(3)
「DOWN CNT」.
(4)
「PRIV.FLAG」
18-5
Page 147
CHAPTER 18 DETAILS OF SYSTEM GENERATION
18.2.2
EXPANSION B
Currently not used. (1)
「INTIAL W」
(2)
「LENGTH W」
(3)
「AXIS UP/DOWN」
(4)
「ANGLE REV.」
18.2.3
MAINTENANCE DATA
Data in this group sets data used for maintenance. Unless otherwise required, enter “0” (default value) for each item. (1)
「CPC SELECT」 Not used.
(2)
「CPC LOOP TIME」 Not used.
(3)
「CPC SP1」 Not used.
(4)
「CPC SP2」 Not used.
(5)
「A-CAL CHECK」
• Number of entry digits : 3 • Minimum unit :1 • Standard setting :0 Determines the A-CAL operation. Values 0 : Defines the current position as the robot origin. 1 : Defines errors caused while the robot origin is outside the limited area as warning (displaying “WARNING” on screen) to continue the operation process. 2 : Ignores errors caused when the robot origin is outside the limited area. 16 : Defines the robot origin when the ORIGIN (ORG) sensor turns ON. 32 : Defines the robot origin when the ORIGIN (ORG) sensor turns ON and Z signal of motor turns ON. To select more than one of the processes above, enter the total of the values selected. However, it is not possible to select the combination of 1 and 2, or 16 and 32.
18-6
Page 148
CHAPTER 18 DETAILS OF SYSTEM GENERATION
(6)
「POS ERROR SEL」 Currently not supported. Specifies whether or not positioning error i is detected. Values 0 : Detects. 1 : Does not detect. (displaying “WARNING”)
(7)
「AB SLOWDOWN TIM」 Currently not supported. Manually sets timing to slow-down for A, B, and W-Axes. With 0 setting, the system automatically controls.
(8)
「SERVO TYPE」 Currently not in use.
(9)
「EMP SELECT」 (Encoder Monitor Program SELECT)
• Number of entry digits : 3 • Minimum unit :1 • Standard value :0 Sets whether the “DRIVER ERROR” detection is valid or invalid, and whether the detected encoder battery alarm is valid or invalid. Values 0
: Tests all the axes.
1
: Tests A (X)-Axis.
2
: Tests B (Y) -Axis.
3
: Tests Z-Axis.
8
: Tests W-Axis.
16 : Tests R-Axis. 32 : Tests C-Axis. 128 : Invalidates the detected encoder battery alarm. To specify so that a certain axis will not be tested, enter a total excluding the value corresponding to that axis. Currently, “DRIVER ERROR” detection is not supported. (10) 「HOLD POWER SAVE」 Currently not supported. Sets a time interval to switch from HOLD to braking. (for special models with additional specifications only)
i
: Occurs when positioning cannot be performed due to hunting or external pressure.
18-7
Page 149
CHAPTER 18 DETAILS OF SYSTEM GENERATION
(11) 「Z SLOWDOWN TIM」 Currently not supported. Manually sets timing to slow-down for Z-Axis. With 0 setting, the system automatically controls. (12) 「STATION NO」
• Number of entry digits : 3 • Valid range : 0 to 999 • Minimum unit : 1 • Standard value : Robot No. (“1” for ROBOT 1) Set a value when station No. should be specified for communication. (13) 「SENSOR STOP SEL」 Currently not supported. Changes the input logic of the W-Axis sensor when the sensor stops. (14) 「SENSOR COUNT」 Currently not supported. Changes the input detection amplitude of the W-Axis sensor when the sensor stops. (15) 「PTP Z IN DATA」 Currently not in use. (16) 「POSITIONING CNT」 Currently not in use.
18.3
ORIGIN In the ORIGIN group, you enter and set values and data mechanically intrinsic to robots. Failing to enter correct data for the items in this group results in irregular functioning in CPC operation and inaccuracy in data based on values on coordinates. Also, this group contains data that determine, upon application, the basic combinations of robots and motions.
18-8
Page 150
CHAPTER 18 DETAILS OF SYSTEM GENERATION
18.3.1
SET-UP SYSTEM (1)
「TRANSFER RATE」
•
Standard value : 9600 [bps]
Select the data transfer speed for RS-232C (selecting a characterform value). When the value has been changed, turn OFF the power supply for controller power and then turn it ON again. Select a value from the following: ・ 300
・ 600
・ 1200
・ 2400
・ 4800
・ 9600
・ 19200 ・ 38400 (2)
「ON-LINE SELECT」
• • •
Number of entry digit: 1 Minimum unit: 1 Standard value: 0
Values 0 : Standard 1 : Not in use. 2 : Uses the vision. 4 : Cancels the function of sequential speed acceleration i to allow operation at the specified speed from the start. To use more than one of the above, enter the total of the values selected. For instance, to use vision and sequential speed-up, enter 6. To use speed-up function alone, enter 4. (3)
「STOP SELECT」
•
Standard value : STATUS
Selects a way for detecting STOP signal (IN5) when it is input. (selecting a character-form value) Values STATUS : Detects the signal by status RISING
: Detects only the rising.
When “RISING” is selected for the above item, “STOP” must be selected for the next item.
i
: For the first three points, operation is carried out at a lower speed in standard condition. (first point: 20% of the speed; second point: 40%; third point: 60%; fourth point: 100%)
18-9