Page 151
CHAPTER 18 DETAILS OF SYSTEM GENERATION
(4)
「STOP」
•
Standard value : STOP
Selects a function of the STOP signal (IN5). (selecting a characterform value) Values
STOP : Stops when STOP signal turns ON and restarts with START or NEXT signal input after STOP signal (IN5) turns OFF. PAUSE : Pauses while STOP signal (IN5) is ON.
(5)
「STORE ADDRESS」
•
Standard value : NEXT
Selects an address to which the system returns upon recovery from power interruption. (Selecting a character-form value) Valid for AUTO mode of automatic operation. When power is shut down during robot operation, for example, due to power failure, either the address where the system was operating the moment when the power was cut, or the next address is selected according to the setting after the power supply is recovered. Values NEXT : Selects the address next to the address where power was interrupted. CURR : Selects the address where power was interrupted. (6)
「I/O ASSIGNMENT」
• Number of entry digit : 1 • Minimum unit : 1 • Standard value : 0 Selects whether to use DI/DO as standard or as defined I/O. To use this function, turn OFF the power after setting the value and turn ON the power again. Values 0 : Standard 1 : Uses in ON-LINE mode all of the OUT 0-OUT 15 in the same way as that in AUTO mode (outputting MOUT). 2 : A and B area output 4 : Base position output 8 : Outputs to an axis at the base position.
18-10
Page 152
CHAPTER 18 DETAILS OF SYSTEM GENERATION
(7)
「INCHING SELECT」
• Number of entry digit : 1 • Minimum unit : 1 • Standard value : 0 Values 0
(8)
:
1
: Validates limitations on inching. When overrun or area limit is input during inching, the inching operation is stopped.
2
: Uses special functions such as offsetting by a S-code (S-code: 1-89).
4
: Carries out linear inching i during inching in AUTO mode. (Invalidated when expanded interfaces are used.)
「M DATA」
• Number of entry digits : 2 • Valid range : 0 to 99 • Minimum unit : 1 • Standard value : 0 Sets definitions of use for M-data. For details, refer to 16.4.3, “Changes in M-data and S-code Functions Depending on System Generation Setting.” Values
0 : Sets the insertion motion, starting X, Y, and W-Axes simultaneously where M-data are in the fifties (M=50-59). 8 : Does not allow M-data to change operations/motions. Allows only S-codes to change operations/motions.
(9)
「AUTO/ON-LINE」 Specifies the mode to be used when ON-LINE operation is activated. (selecting a character-form value)
•
Standard value : ON-LINE
Values ON-LINE AUTO
: Uses ON-LINE mode. : Uses AUTO mode.
EXT AUTO : Uses extended AUTO mode. Select this value when 1000 or more position addresses are used. Note that with “EXT AUTO,” DI/DO assignment changes. (Refer to 7.2, “Extended AUTO Mode.”)
i
: Normally axes are inched individually. When the linear inching is specified, inching operation takes place on X-Y coordinates. Refer to 5.2.1, “Operation with X-Y Coordinates in LI-TEACH Mode."
18-11
Page 153
CHAPTER 18 DETAILS OF SYSTEM GENERATION
(10) 「EMERGENCY STOP」
•
Standard value: KEEP
The value is currently invalid. Normally the A-CAL is constantly retained. Select either character-form value for A-CAL for emergency stops. Press the Values
KEEP io SEL key to select.
: Retains the A-CAL.
RESET : Resets the A-CAL.
18.3.2
AXIS DIRECTION (1)
「A-CAL SEQ」
• Number of entry digits : 6 • Minimum unit : 111111 • Standard value : 221222 Specifies an order in which A-CAL is performed for the axes. Each digit corresponds to an axis as shown below. 000000 ↓↓↓↓↓↓ ABZWRC Enter the same value for axes for which A-CAL is performed at the same time. (2)
「A-CAL DIR. A」 : A-CAL direction for A-Axis (X-Axis).
(3)
「A-CAL DIR. B」 : A-CAL direction for B-Axis (Y-Axis).
(4)
「A-CAL DIR. Z」 : A-CAL direction for Z-Axis.
(5)
「A-CAL DIR. W」 : A-CAL direction for W-Axis.
(6)
「A-CAL DIR. R」 : A-CAL direction for R-Axis.
(7)
「A-CAL DIR. C」 : A-CAL direction for C-Axis.
•
Standard value for the above : PLUS
Each item above changes the direction of A-CAL. (selecting a character-form value) Values PLUS
: Normal direction
MINUS : Reversed direction Be sure to record the data specified for the above items after the robot installation.
18-12
Page 154
CHAPTER 18 DETAILS OF SYSTEM GENERATION
(8)
「INCHI DIR. A」 : Inching direction for A-Axis (X-Axis)
(9)
「INCHI DIR. B」 : Inching direction for B-Axis (Y-Axis)
(10) 「INCHI DIR. Z」 : Inching direction for Z-Axis (11) 「INCHI DIR. W」 : Inching direction for W-Axis (12) 「INCHI DIR. R」 : Inching direction for R-Axis (13) 「INCHI DIR. C」 : Inching direction for C-Axis
•
Standard value for the above : PLUS
Each item above changes the direction of inching. (selecting a character-form value) Values PLUS
: Normal direction
MINUS : Reversed direction
18.3.3
AXIS SELECT (1)
「A AXIS TYPE」: A-Axis (X-Axis)
(2)
「B AXIS TYPE」: B-Axis (Y-Axis)
(3)
「Z AXIS TYPE」: Z-Axis
(4)
「W AXIS TYPE」: W-Axis
(5)
「R AXIS TYPE」: R-Axis
(6)
「C AXIS TYPE」: C-Axis
•
Standard value : USED
Specifies the status of the each axis, whether it is to be used or not. (selecting a character-form value) Values NOT USED : Sets the non-use condition. USED
: Sets the use condition.
Be sure to record the data specified for the above items after the robot installation.
18-13
Page 155
CHAPTER 18 DETAILS OF SYSTEM GENERATION
(7)
「A AXIS SEL」: Selects A-Axis (X-Axis).
(8)
「B AXIS SEL」: Selects B-Axis (Y-Axis).
(9)
「Z AXIS SEL」: Selects Z-Axis.
(10) 「W AXIS SEL」: Selects W-Axis. (11) 「R AXIS SEL」: Selects R-Axis. (12) 「C AXIS SEL」: Selects C-Axis.
•
Standard value : USED
Each of the above values is currently invalid. Currently the axis is held even if the setting is NOT HOLD. Select either characterform value for the axis. Values
NOT HOLD : Normal HOLD
: Constantly holds the axis.
Be sure to record the data specified for the above items after the robot installation.
18.4
ADJUST The items in this group are used to set the values of the robot main unit.
18.4.1
AR TYPE ADJUST (1)
「INITIAL A」
(2)
「INITIAL B」
(3)
「INITIAL Z」
(4)
「INITIAL W」
(5)
「INITIAL R」
(6)
「INITIAL C」
• Number of entry digits : 7 • Valid range : -7999.999 to 7999.999 • Minimum unit : ±0.001 Specifies the initial value of the robot. Normally, the position where A-CAL is performed is specified as the origin. When you wish to move the origin from the originally given position to another position, specify a value necessary for correction Be sure to record the data specified for the above items after the robot installation.
18-14
Page 156
CHAPTER 18 DETAILS OF SYSTEM GENERATION
INITIAL B INITIAL A
Fig.18.3 INITIAL A (7)
「LENGTH A」
(8)
「LENGTH B」
(9)
「LENGTH Z」
Fig.18.4 INITIAL B
(10) 「LENGTH W」 (11) 「LENGTH R」 (12) 「LENGTH C」
• • •
Number of entry digits : 7 Valid range
: 0 to 9999.999
Minimum unit
: 0.001
Specifies the arm length for each axis. Used for SCARA (horizontal multi-articulated) robot only. The SCARA robot converts quantities of rotation (in pulse) for A and B-Axes into quantities on X-Y coordinates, determining the position on the coordinates based on the arm lengths from the base point to the tip. Therefore, if the set values of initial data and the arm lengths are not correct, accuracy of the arm positioning in linear motions (arm operation in TEACH mode and CPC operation in automatic operation) becomes lower. The length of the first arm is constant for the model, but the length of the second arm varies depending on the design of the tool used at the tip. Special attention should be paid to the data to be set for the above. Be sure to record the data specified for the above items after the robot installation. (13) 「AXIS COMBINATION」 Not in use.
18.4.2
MB TYPE ADJUST
Currently not supported.
18-15
Page 157
CHAPTER 18 DETAILS OF SYSTEM GENERATION
18.5
CAPABILITY Use this group when checking the specifications of the robot main unit or memory data intrinsic to the robot.
18.5.1
ROBOT CAPABILITY
Displays the individual settings for the encoders. You cannot change the data here. (1)
「ENC. PULSE A」: Encoder pulse for A-Axis (X-Axis)
(2)
「ENC. PULSE B」: Encoder pulse for B-Axis (Y-Axis)
(3)
「ENC. PULSE Z」: Encoder pulse for Z-Axis
(4)
「ENC. PULSE W」: Encoder pulse for W-Axis
(5)
「ENC. PULSE R」: Encoder pulse for R-Axis
(6)
「ENC. PULSE C」: Encoder pulse for C-Axis
• •
Number of entry digits : 7 Minimum unit
:1
Displays the encoder pulse set for each axis. (7)
「LEAD/GEAR A」: Lead/gear setting for A-Axis (X-Axis)
(8)
「LEAD/GEAR B」: Lead/gear setting for B-Axis (Y-Axis)
(9)
「LEAD/GEAR Z」: Lead/gear setting for Z-Axis
(10) 「LEAD/GEAR W」: Lead/gear setting for W-Axis (11) 「LEAD/GEAR R」: Lead/gear setting for R-Axis (12) 「LEAD/GEAR C」: Lead/gear setting for C-Axis
• •
Number of entry digits : 6 Minimum unit
: 0.001
Displays the lead or gear ratio set for each axis. (13) 「MOTER REV. A」: Maximum motor revolution speed for A-Axis (XAxis) (14) 「MOTER REV. B」: Maximum motor revolution speed for B-Axis (YAxis) (15) 「MOTER REV. Z」: Maximum motor revolution speed for Z-Axis (16) 「MOTER REV. W」: Maximum motor revolution speed for W-Axis (17) 「MOTER REV. R」: Maximum motor revolution speed for R-Axis (18) 「MOTER REV. C」: Maximum motor revolution speed for C-Axis
• •
Number of entry digits : 4 Minimum unit
:1
Displays the maximum motor revolution speed set for each axis.
18-16
Page 158
CHAPTER 18 DETAILS OF SYSTEM GENERATION
18.5.2
EXPANSION A
The following data are system data for expansion to be specified when applicable data items are added. Therefore, specify “0” for the following items unless our company requests otherwise. (1)
「EXPANSION 0」
(2)
「EXPANSION 1」
(3)
「EXPANSION 2」
(4)
「EXPANSION 3」
(5)
「EXPANSION 4」
(6)
「EXPANSION 5」
(7)
「EXPANSION 6」
(8)
「EXPANSION 7」 Not used.
(9)
「CPC INTEG GAIN」 Not used.
(10) 「FV TIME 0」 (11) 「FV TIME 1」 (12) 「FV TIME 2」 Not used.
18-17
Page 159
CHAPTER 19 DETAILS OF SYSTEM PARAMETERS
CHAPTER 19 19.1
Details of System Parameters
MOTION The items in this group set conditions of robot operations and motions.
19.1.1
MOTION (1)
「PULL-UP」
• Number of entry digits : 7 • Valid range : 5 up to the value of the maximum working area of Z-Axis
• Minimum unit • Standard value
: 0.001 : 10
With 「PULL-UP」 setting, Z-Axis is automatically moved in PTP operation. In PTP operation, when moving from a point to another, both of which are at a lower level than the setting of 「PULL-UP」, the robot will not move horizontally at that level. The robot automatically raises the Z-Axis to the set value (automatic pull-up), then moves horizontally, then lowers the Z-Axis for positioning. This item specifies the distance from the Z-Axis origin to the level at the point where horizontal move is started. The value is specified in “mm.” Z-Axis origin C
B
A
Work
「PULL-UP」 (mm)
D
Fig.19.1 PULL-UP Motion For example, in the figure above, if the robot moves horizontally from point A to point D, it will interfere with the work. When a 「PULL-UP」 value is set so that the Z-Axis reaches to point B (level B), the robot starts horizontal move from that level via point C to point D for positioning. However, when moving between two points which are exactly on the same position on X-Y coordinates but different in height on Z coordinate, the PULL-UP motion is not performed. Specify a value for 「PULL-UP」 according to the robot used so that the ORIGIN (ORG) sensor does not turn ON due to the setting during the PULL-UP motion.
19-1
Page 160
CHAPTER 19 DETAILS OF SYSTEM PARAMETERS (2)
「ARCH UP」
• Number of entry digits : 7 • Valid range : 0 up to the value of the maximum working area of Z-Axis
• Minimum unit • Standard value
: 0.001 : 0
In PTP operation, the robot starts horizontal shift after the Z-Axis is raised, and lowers Z-Axis after the horizontal shift is finished. When automatic PULL-UP is activated, this gate motion is executed to avoid interference of work with the robot moving horizontally. 「ARCH UP」 allows the robot to move horizontally while the Z-Axis is rising, under a 「PULL-UP」 setting. Because of this, the tact time for the ARCH-UP motion is shorter than for the regular PULL-UP (gate) motion above. However, if an incorrect value is set, the robot may interfere with the work. Therefore, use care to set a correct value. Z-Axis origin 「PULL UP」 「ARCH UP」 D (mm)
Work
Fig.19.2 ARCH UP A value specified for 「ARCH UP」 is a distance from the Z-Axis origin. When setting for ARCH UP motion, check and confirm the difference between the value set for 「ARCH UP」 and that for 「PULL-UP」. Specifically, confirm that by what mm the ARCH UP level should be lower than the PULL-UP level. For example, as illustrated above, specify a value D (mm) that allows Z-Axis to start horizontal shift without interference with the work.
19-2