Page 161

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS (3)

「ARCH DOWN」

• Number of entry digits : 7 • Valid range : 0 up to the value of the maximum working area of Z-Axis

• Minimum unit • Standard value

: 0.001 : 0

In PTP operation, the robot starts horizontal shift after the Z-Axis is raised, and lowers Z-Axis after the horizontal shift is finished. When automatic PULL-UP is activated, this gate motion is executed to avoid interference of work with the robot moving horizontally. 「ARCH DOWN」 allows the robot to lower the Z-Axis while moving horizontally, under a 「PULL-UP」 setting. Because of this, the tact time for the arch down motion is shorter than for the regular PULL-UP (gate) motion above. However, if an incorrect value is set, the robot may interfere with the work. Therefore, use care to set a correct value. Z-Axis origin 「PULL UP」 「ARCH DOWN」 D (mm)

Work

Fig.19.3 ARCH DOWN A value specified for 「ARCH DOWN」 is a distance from the Z-Axis origin. When setting for ARCH DOWN motion, confirm the difference between the value set for 「ARCH DOWN」 and that for 「PULL-UP」. Specifically, confirm that by what mm the ARCH DOWN level is lower than the PULL-UP level. For example, as illustrated above, specify a value D (mm) that allows Z-Axis to start lowering while horizontal move without interference with the work.

19-3

Page 162

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS (4)

「INS DIS.」

• Number of entry digits : 7 • Valid range : 0 up to the value of the maximum working area of Z-Axis

• Minimum unit • Standard value

: 0.001 : 20

Sets the distance for which the PTP insertion motion is performed. The robot starts deceleration at the level (value) which is obtained by taking the set value from the level (value) of the target point to which the Z-Axis lowers.

Z-Axis lowers Positioning with decelerated speed 「INS DIS.」

Target point

Fig.19.4 INS DIS. (5)

「INS SPEED」 (Inserting speed)

• Number of entry digits : 3 • Valid range : 0 to 99 • Minimum unit :1 • Standard value : 20 Sets inserting speed for PTP insertion motion. The maximum speed of each axis varies depending on the robot type. The maximum speed is scaled into 100 levels (0: minimum speed-99: maximum speed). The inserting speed can be specified by selecting a value (0-99) which functions as a ratio to the maximum speed. The robot moves the distance specified in (4) above at a decelerated speed. The area S2 represents the distance where the insertion motion 「INS DIS.」 takes place. Speed

Z-Axis lowering speed

「INS SPEED」

S1 S2

Time

Fig.19.5 INS SPEED

19-4

Page 163

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

When the speed of Z-Axis immediately before moving into the distance set for 「INS DIS.」 is set lower than the 「INS SPEED」, the lower speed will control. For example, if Z-Axis is lowering at 50 and the speed set for 「INS SPEED」 is 100, the axis does not change speed to that as represented in dotted line in the diagram below, but moves as illustrated in straight line. The area S2 represents the distance 「INS DIS.」 where the insertion motion takes place. Speed 「INS SPEED」

Z-axis lowering speed S1

S2 Time

Fig.19.6 Notes for 「INS SPEED」 Setting Value

(6)

「UP DIS.」 (distance of moving up)

• Number of entry digits : 7 • Valid range : 0 up to the value of the maximum working area of Z-Axis

• Minimum unit • Standard value

: 0.001 : 20

Sets the distance for which the PTP slow-up motion is performed. The distance where the Z-Axis moves at a slower speed is specified when Z-Axis starts moving up.

Z-Axis moving up

Distance where the Z-Axis moving up at a slower speed 「UP DIS.」

Fig.19.7 UP DIS.

19-5

Page 164

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

(7)

「UP SPEED」

• Number of entry digits : 3 • Valid range : 0 to 99 • Minimum unit : 1 • Standard value : 20 Sets the speed of moving-up for PTP slow-up motion. The robot moves the distance specified in (6) 「UP DIS.」 above at a speed specified in this step. The area S1 represents the distance of moving up, 「UP DIS.」, where the slow-up motion takes place. Speed

Z-Axis moving up speed S2 「UP SPEED」 S1

Time

Fig.19.8 UP SPEED

When the speed of Z-Axis immediately after moving out of the distance set for 「UP DIS.」 is set lower than the 「UP SPEED」, the lower speed will control. For example, if Z-Axis is moving up at 50 and the speed set for 「UP SPEED」 is 100, the axis does not change speed to that as illustrated in dotted line in the diagram below, but moves as shown in straight line. The area S1 represents the distance 「UP DIS.」 where the slow-up motion takes place. 「UP SPEED」

Speed

Z-axis moving up speed S1

S2 Time

Fig.19.9 Notes for 「UP SPEED」 Setting Value

(8)

「Z NEXT PULL」 Currently not used.

19-6

Page 165

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

19.1.2

AXIS SPEED (1)

「SPEED A, B (X, Y) W」 (Speed of axes, A, B (X, Y) W)

(2)

「SPEED Z」 (Speed of Z-Axis)

• Number of entry digits : 3 • Valid range : 0 to 100 • Minimum unit :1 • Standard value : 100 For automatic operation, specify the operating speed of each axis except for that in CPC operation. The maximum speed of each axis differs depending on the robot type. The maximum speed is scaled into 100 levels (0: Minimum speed to 100: Maximum speed). The speed can be specified by selecting a value (0-100) which functions as a ratio to the maximum speed. The value specified in this step sets the speed of every positioning. The speed in CPC operation should be specified for 「CPC SPEED」 described in the following section. (3)

「SPEED B」 (B-Axis speed for expansion)

(4)

「SPEED W」 (W-Axis speed for expansion)

(5)

「EXPANSION 2」 (R-Axis speed for expansion)

(6)

「EXPANSION 1」 (C-Axis speed for expansion)

• Number of entry digits : 3 • Valid range : 0 to 100 • Minimum unit :1 • Standard value : 100 Use the above items to specify a speed for each of the axes as expanded functions. In this case, 「SPEED A, B (X, Y), W」 functions as the setting for the speed of A-Axis (X-Axis). For automatic operation, specify the operating speed of each axis except for that in CPC operation. The maximum speed of each axis differs depending on the robot type. The maximum speed is scaled into 100 levels (0: Minimum speed to 100: Maximum speed). The speed can be specified by selecting a value (0-100) which functions as a ratio to the maximum speed.

19-7

Page 166

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

19.1.3

CPC CONSTANT (1)

「CPC SPEED」

• Number of entry digits : 3 • Valid range : 0 to 999 • Minimum unit :1 • Standard value : 100 Sets speed for interpolation (CPC operation). The scale unit for this item is 1 mm/sec. The tip speed depends on the setting of 「CPC SPEED」 and the Fcode specified for the start of the CPC operation. Tip speed (mm/sec) = 「CPC SPEED」 x

1 + F-code (mm/sec) 100

The maximum speed differs depending on the robot type. Even if a value greater than the maximum speed specific to the robot is set, the robot will operate at its rated maximum speed. (2)

「CPC F.F. GAIN」 Currently not used.

(3)

「SPLINE SPEED」 Currently not used.

(4)

「CPC CONSTANT」

• Number of entry digits : 3 • Valid range : 0 to 100 • Minimum unit :1 • Standard value :0 Sets the smoothness at the passing point in continuous CPC operation. The setting range is between 0-100%. The curve is most smooth with the setting 0, and the most steep with the setting 100. (5)

「CPC ACCEL/DECEL」 (CPC acceleration/deceleration)

• Number of entry digits : 3 • Valid range : 0 to 100 • Minimum unit :1 • Standard value : 80 Sets the acceleration/deceleration of the speed during CPC operation.

19-8

Page 167

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

19.2

RESPONSE

19.2.1

ACCEL

The accelerating/decelerating time is determined by the robot type, and set by configuration. (Refer to 20.4, Assigning Motors to Robot Axes.”) The accelerating/decelerating time set in the configuration is treated as the minimum time required. Items in this group set the ratio of (number of times of) such time required to complete the acceleration/deceleration. (1)

「ACCEL SELECT」

• Standard value : AUTO Currently the above value is not used. The setting is constantly MANUAL. Selects either to set acceleration/deceleration with the settings of the following (2)「ACCEL A」 to (7)「ACCEL C」, or to set the optimized acceleration/deceleration using the weight of work in addition to the settings of (2) to (7). (selecting a character-form value) AUTO

: Automatically creates to set an accelerating/decelerating time. Optimizes the acceleration/deceleration by using the values of (2)「ACCEL A」 to (7)「ACCEL C」 and the setting of 「PTP WEIGHT」 reached by selecting 「RESPONSE」→「RESPONSE」 in System Parameter menu. Allows smooth acceleration/deceleration for carrying heavy works.

MANUAL : Requires specifying values for (2)「ACCEL A」 to (7) 「ACCEL C」.

AUTO is quite effective for SCARA (horizontal multi-articulated) robots. However, for Cartesian robots, acceleration varies due to the simplified calculation value of 「PTP WEIGHT」. Therefore, to obtain a shorter tact time, change values for the following items of acceleration data with the 「PTP WEIGHT」 set to 0.

19-9

Page 168

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

(2)

「ACCEL A」

(3)

「ACCEL B」

(4)

「ACCEL Z」

(5)

「ACCEL W」

(6)

「ACCEL R」

(7)

「ACCEL C」

• Number of entry digits : 3 • Valid range : 0 to 100 • Minimum unit :1 • Standard value : 80 Each of the above is to slow-down acceleration/deceleration of the axis. In standard condition, always set between 70-100. The smaller the value becomes, the more gradual the acceleration becomes. Table 19.1 Set Value and Acceleration/Deceleration Time (Minimum Time:1) 「ACCEL」 value 100 90 80 70 60 50 40 30 20 10

Acceleration/Deceleration time 1 10/9 10/8 10/7 10/6 10/5 10/4 10/3 10/2 10/1

The optimum values of 「ACCEL」 for various robot with working load are given below. Table 19.2 Optimum ACCEL Value and Working load 「ACCEL」 value 80

AR-C270 With 2kg working load

AR-C350 With 2kg working load

70 With 4kg working load

60

19-10

MB With standard working load

Page 169

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

19.2.2

AXIS INP PULSE

This group is not used. In the past, the group was used to specify positioning accuracy, which now is specified by servo parameters. Refer to 12.5, “Setting Servo Parameters (SERVO),” and the user’s guide of the controlled units used. (1)

「INP PULSE A, B」

(2)

「PULSE B」

(3)

「INP PULSE Z」

(4)

「INP PULSE W」

(5)

「EXPANSION 2」

(6)

「EXPANSION 1」

19.2.3

RESPONSE (1)

「SAFE. ZONE」

• Number of entry digits : 7 • Valid range : 0 up to the value of the maximum working area of Z-Axis

• Minimum unit • Standard value

: 0.001 : 10

Outputs to turn ON OUT5 when Z-Axis moves up to a higher level than the setting of this item (when the level value becomes smaller than the setting). Used for determining robot refuge. The unit is mm (millimeter). The conditions of the output (OUT5) are: ① AUTO is selected for 「AUTO/ON-LINE」 reached by selecting 「ORIGIN」→「SET-UP SYSTEM」 in System Generation menu, OUT5 is output either in TEACH, CHECK, or AUTO mode. ② When ON-LINE is selected for 「AUTO/ON-LINE」 reached by selecting 「ORIGIN」→「SET-UP SYSTEM」 in System Generation menu, and only when 1 is set for 「I/O ASSIGNMENT」 reached by selecting 「ORIGIN」→「SET-UP SYSTEM」 in System Generation menu, OUT5 is automatically output. Z origin

Outputs to turn ON OUT5

「SAFE. ZONE」

Fig.19.10 SAFE.ZONE

19-11

Page 170

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

・ The setting becomes invalid when A-CAL has not been completed. With A-CAL incomplete, output of OUT5 is always OFF. ・ In KEY-IN mode, OUT5 will not change. ・ When PULL-UP function of Z-Axis is used, specify for 「SAFE. ZONE」 a value greater than the setting of 「PULL-UP」 i. If the same value as 「PULL-UP」 is set for 「SAFE. ZONE」, output of OUT5 may keep switching ON and OFF or may not turn ON. (2)

「A-CAL SPEED」

• Number of entry digits : 3 • Valid range : 1 to 999 • Minimum unit :1 • Standard value : 50 Sets speed during A-CAL. The maximum speed of each axis varies depending on the robot type. The maximum speed is scaled into 1000 levels (0.1% to 99.9 %), and the speed can be set between the above range. However, for ensuring safety, the robot will not operate at 250mm/sec or greater. (3)

「INCHING SPEED」

• Number of entry digits : 3 • Valid range : 1 to 999 • Minimum unit :1 • Standard value :2 Sets inching speed. The maximum speed of each axis varies depending on the robot type. The maximum speed is scaled into 1000 levels (0.1% to 99.9 %), and the speed can be set between the above range. However, for ensuring safety, the robot will not operate at 250mm/sec or greater. (4)

「PTP WEIGHT」

• Number of entry digits : 7 • Valid range : 0 up to the value of the maximum transportation weight

• Minimum unit • Standard value

: 0.001 : 2

Specifies the total weight of tip tool and a work (kg). By using this value, the system automatically optimizes the acceleration/deceleration during PTP operation and pass PTP operation. The optimization is constantly carried out during pass PTP operation. For PTP operation, acceleration/deceleration is optimized when AUTO is set for 「ACCEL SELECT」 reached by selecting 「RESPONSE」→「ACCEL」 in System Generation menu.

i

: Specified by the System Parameter, 「MOTION」→「MOTION」→「PULL-UP」.

19-12