Page 171

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS (5)

「EXPANSION 1」 Not used.

(6)

「COMPLAINCE」 Not used.

(7)

「DD INDEX GAIN」 Not used.

(8)

「PTP CONST AB」 Not used.

(9)

「PTP CONST Z」 Not used.

(10) 「PTP CONST W」 Not used.

19.3

OFFSET 「DISPLAY OFFSET」 specifies the origin of each coordinate for the purpose of displaying. Since each 「DISPLAY OFFSET*」, reached by selecting 「OFFSET」 in System Parameter menu, is an offset used for display only, the actual robot position will not be changed even when offset values are changed. By using offset settings, you can:

z Establishes a relationship between the robot and the work based on the coordinate and make position data entry easier in KEY-IN mode.

z Moves the robot parallel with the coordinate concerned in LITEACH mode to make teaching easier.

z Sets for 「AREA LIMIT」 i easily by specifying a coordinate system. Three kinds of coordinate systems are available. (Refer to 2.7, “LCD (Liquid Crystal Display.”) “To display offset” means to switch the display of the robot-specific world coordinate system to that of the coordinate system of work (transferred data). The world coordinate system is converted into the work coordinate system in the following way: The origin of the world coordinate system is moved by (Δx, Δy) on the X-Y plane, and the position becomes the origin of the work coordinate system, as illustrated below. And then, the coordinate system is rotated by ΔR around the origin. As for the Z and W-Axes, the coordinate origin is located where Δz is subtracted, and where the coordinate is rotated in the opposite direction by Δw respectively.

i

: 「LIMIT」→「AREA LIMIT」 in System Generation menu.

19-13

Page 172

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS y Work coordinates x

Y ΔR

Δx=「DISP. X」 Δy=「DISP. Y」 ΔR=「DISP. R」

(Δx, Δy)

X World coordinates

Fig.19.11 「OFFSET」 (1)

「DISP. X1」 (Display X1)

(2)

「DISP. Y1」 (Display Y1)

(3)

「DISP. R1」 (Display R1)

(4)

「DISP. X2」 (Display X2)

(5)

「DISP. Y2」 (Display Y2)

(6)

「DISP. R2」 (Display R2)

(7)

「DISP. X3」 (Display X3)

(8)

「DISP. Y3」 (Display Y3)

(9)

「DISP. R3」 (Display R3)

• Number of entry digits : 7 • Valid range : X-Axis: -7999.999 to 7999.999 Y-Axis: -7999.999 to 7999.999 R-Axis: -180.000 to 180.000

• Minimum unit • Standard setting

: ±0.001 :0

Sets the origin of the X-Y coordinates to be displayed.

19-14

Page 173

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

「DISP. X*」 is for offsetting X-Axis for display and 「DISP. Y*」 is for offsetting Y-Axis for display, each specified in “mm,” while “DISP. R*” is for offsetting by rotating the coordinate for display specified in degree (angle). Since each 「DISPLAY OFFSET」 is an offset used for display only, the actual robot position will not be changed even when offset values are changed. Specify values in the following example for 「DISPLAY OFFSET 1」: ① Enter 0 for 「DISP. X1」, 「DISP. Y1」 and 「DISP. R1」 respectively. ② After A-CAL is completed, move the robot in TEACH mode to the position which will be the origin of the new X-Y coordinate to be displayed. ③ Read off the X and Y values of the position. Enter the values for 「DISP. X1」 and「DISP. Y1」 respectively. ④ When you wish to rotate the X-Y coordinate, calculate the value to be set for 「DISP. R1」 by using the two positions (X1, Y1) and (X2, Y2) on the line which will become the new X-coordinate. Y

Y

(X2, Y2)

X

(X1, Y1) R1

「DISP.R1」 = tan-1

X

Y2-Y1 X2-X1

Fig.19.12 Calculating 「DISP. R1」 (10) 「DISP. Z1」 (Display Z1) (11) 「DISP. Z2」 (Display Z2) (12) 「DISP. Z3」 (Display Z3)

• Number of entry digits : 7 • Valid range : Z-Axis -7999.999 to 7999.999 • Minimum unit : ±0.001 • Standard setting : 0 Sets the origin of the Z coordinate to be displayed. 「DISP. Z*」 is for offsetting Z-Axis for display, specified in “mm.” Since each 「DISPLAY OFFSET」 is an offset used for display purpose only, the actual robot position will not be changed even when offset values are changed.

19-15

Page 174

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

(13) 「DISP. W1」 (Display W1) (14) 「DISP. W2」 (Display W2)) (15) 「DISP. W3」 (Display W3)

• Number of entry digits : 7 • Valid range : W-Axis -540.000 to 540.000 • Minimum unit : ±0.001 • Standard setting :0 Offset value of W-Axis from X-Y coordinate. A value for W-Axis is an angle displayed based on the X-Y coordinates. After an X-Y coordinate system is specified by display offsetting, the operating direction of the W-Axis and the display will be constant on the X-Y coordinate system. 「DISP. W*」 is for setting the origin on W-Axis for the setting coordinate. Since each 「DISPLAY OFFSET」 is an offset used for display purpose only, the actual robot position will not be changed even when offset values are changed. Specify values in the following example for 「DISPLAY OFFSET 1」: ① Enter system data for 「DISP. X1」, 「DISP. Y1」 and 「DISP. R1」 respectively to specify the X-Y coordinate system. ② Enter 0 for 「DISP. W1」. ③ After A-CAL is completed, rotate the robot in TEACH mode to the position where the origin of the new coordinate will be set. ④ Read off the W1 value of the position. Enter the value for 「DISP. W1」. Since 「DISP. W1」 is an offset value for the display purpose only, the mechanical working area will not be changed. Because of this, if the work coordinate system is newly changed, entering data of W-Axis may not be accepted even though the values are identical with those of the former coordinate system, “AREA ERROR” being caused. (16) 「TOOL X1」 (17) 「TOOL Y1」 (18) 「TOOL Z1」 (19) 「TOOL X2」 (20) 「TOOL Y2」 (21) 「TOOL Z2」 (22) 「TOOL X3」 (23) 「TOOL Y3」

19-16

Page 175

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS (24) 「TOOL Z3」 Currently not supported. Specify data to switch display referenced with a coordinate system with the origin at the tool’s working center. Three types are available, allowing three different displays for the three tools. These items are used in combination with the 「DISP. **」 items described before.

19.4

SET-UP 「SET-UP」 contains data areas for expansion. There are two groups, 「EXPANSION A」 and 「EXPANSION B」.

19.4.1

EXPANSION A

Used for expansion. (1)

「Pass PTP Select」 Currently not supported. Switches from pass PTP operation, in which the robot does not stop at the passing position, to continuous pass PTP operation, in which regular PTP operation is continued without communication with external units when M-data values in the thirties (30-39) are used. Values

0 :

Specifies pass PTP operation where robot does not stop at the passing position.

1 :

Enables continuous PTP operation without communication with external devices. Stops the robot temporarily at the passing position.

(2)

「Base Pos Addr1」 (Base Position Address 1)

(3)

「Base Pos Addr2」 (Base Position Address 2)

(4)

「Base Pos Addr3」 (Base Position Address 3)

(5)

「Base Pos Addr4」 (Base Position Address 4)

• Number of entry digits : 3 • Valid range : 0 to the value specified for 「ADDRESS MAX」 i

• Minimum unit • Standard setting

: 1 : 0

Specifies the address for the reference base position of the robot (Robot origin).

i

: 「LIMIT」→「ADDRESS MAX」→「ADRRESS MAX」 in System Generation menu.

19-17

Page 176

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS With 「I/O ASSIGNMENT」 set to 4, by selecting 「ORIGIN」→ 「SET-UP SYSTEM」→「I/O ASSIGNMENT」 in System Generation menu, and when the robot is positioned at one of the addresses specified for the items above, OUT4 is output. You can specify four points. OUT4 turns ON when the robot positions at one of the four points specified. By using this output, interlock system can be established to give permission of start to the externally controlled units. To give some allowance in stopping position, set a value for the next item 「Base Pos Pulse」. (6)

「Base Pos Pulse」 (Base Position Pulse)

• Number of entry digits : 5 • Valid range : 0 to 99999 • Minimum unit : 1 • Standard setting : 0 Specifies the allowable variation range(±number of pulses), where OUT4 turns ON, for the address specified for 「Base Pos Addr」 above. Specify a value that is a number of pulses. (7)

「Safety select」 Specifies reference base position for 「ARCH UP」 i and 「SAFE. ZONE」 ii settings. Currently the setting for this item is fixed to 0. Values

19.4.2

0 :

Specifies the origin of Z-Axis as the reference position, validating absolute values of 「ARCH UP」 and 「SAFE. ZONE」.

1 :

Specifies the position currently located as the reference, turning OUT5 signal (ZONE output) ON when Z-Axis rises by a value specified for 「SAFE. ZONE」.

2 :

Specifies the position currently located as the reference, starting to move A and B-Axes (X and Y-Axes) when Z-Axis rises by a value specified for 「ARCH UP」.

EXPANSION B (1)

「SENS. OFF」 (Sensor Offset) Currently not supported. Specifies an offset upon stop of W-Axis sensor.

(2)

「SENS. SKIP」 (Sensor Skip) Currently not supported. Specifies an area where W-Axis sensor is ignored upon stop of W-Axis sensor.

i ii

: 「MOTION」→「MOTION」→「ARCH UP」 in System Parameter menu : 「RESPONSE」→「RESPONSE」→「SAFE.ZONE」 in System Parameter menu

19-18

Page 177

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS (3)

「AREA AX」 (Area Output A(X))

(4)

「AREA BY」 (Area Output B(Y))

• Number of entry digits : 7 • Valid range SCARA (horizontal multi-articulated) robot : -360.000°to 360.000° Cartesian robot : -7999.999mm to 7999.999mm

• Minimum unit • Standard setting

: ±0.001 : 0

Outputs OUT4 ON when the axis is within the specified range. As OUT4 is common with pass PTP output, set 「I/O ASSIGNMENT」 to 2 to use this OUT4 as Area Output, by selecting 「ORIGIN」→「SET-UP」→「I/O ASSIGNMENT」 in System Generation menu. The negative value (-) specifies to output OUT4 when the axis is at a position where the value is smaller than the specified value, and e a positive value (+) specifies to output OUT4 when the axis is at a position where the value is greater than the specified value. With a positive value (+)

: OUT4 is output when the axis is located at a position greater than the value.

With a negative value (-) : OUT4 is output when the axis is located at a position smaller than the value ① SCARA (horizontal multi-articulated) robot With the setting below, OUT4 is output when the tip is at a position in a shaded area. 「AREA AX」= 130°「AREA BY」= 0°

Fig.19.13 Valid Area of SCARA (Horizontal Multi-Articulated) Robot

19-19

Page 178

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

② Cartesian robot With each setting below, OUT4 is output when the tip is at a position in a shaded area. Example 1: 「AREA AX」= 100 mm 「AREA BY」= 150 mm Example 2: 「AREA AX」= -100 mm 「AREA BY」= 150 mm

150

150

A-CAL position

A-CAL position

100

100

Example 1

Example 2

Fig.19.14 Valid Areas of Cartesian Robot

・ The output is OFF when A-CAL is Incompleted. ・ This function is valid in any mode other than KEY-IN and ON-LINE modes. ・ The output turns ON when both Area Outputs A(X) and B(Y) are satisfied. (5)

「Z MD OF.」 (Z Middle Offset) Currently not supported. When S-code setting is either 24 or 25, the Z-Axis is relatively positioned with the value specified here.

(6)

「Z2 PL-UP」 Currently not supported. This item is for the second Z-Axis when the robot uses two Z-Axes. Specifies a value for 「PULL-UP」 i for the second Z-Axis.

(7)

「EXPANSION 14」 Currently not supported.

i

: 「MOTION」→「MOTION」→「PULL-UP」 in System Parameter menu

19-20

Page 179

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

19.5

REMOTE The groups in REMOTE display data set by S command (SAVE) of the HRCS-RⅣ i . You cannot enter data for items in these groups. Data that can be displayed are those in 「MOTION」 and 「RESPONSE」 groups. For details, refer to each group.

19.5.1

MOTION (1)

「PULL-UP」

(2)

「ARCH UP」

(3)

「ARCH DOWN」

(4)

「INS DIS. 」

(5)

「INS SPEED」

(6)

「UP DIS. 」

(7)

「UP SPEED」

19.5.2

SPEED/ACCEL/INPOS (1)

「SPEED A,B(X,Y)W」

(2)

「SPEED B」

(3)

「SPEED Z」

(4)

「SPEED W」

(5)

「EXPANSION 1」

(6)

「EXPANSION 2」

(7)

「ACCEL A,B(X,Y)W」

(8)

「ACCEL ABW(PASS)」

(9)

「ACCEL Z」

(10) 「ACCEL Z(PASS)」 (11) 「EXPANSION 3」 (12) 「EXPANSION 4」 (13) 「INP PULSE A,B」 (14) 「INP PULSE B」 (15) 「INP PULSE Z」 (16) 「INP PULSE W」 (17) 「EXPANSION 5」 (18) 「EXPANSION 6」 i

: HRCS-RⅣ: Communication protocol of our company. Used to control robot with RS-232C from the higher computer (PC, or the like). For details, refer to separate volume, "HRCS-RⅣ Operation Manual."

19-21

Page 180

CHAPTER 19 DETAILS OF SYSTEM PARAMETERS

19.5.3

REMOTE MOTION (1)

「CPC SPEED」

(2)

「CPC F.F.GAIN」

(3)

「SPLINE SPEED」

(4)

「A-CAL SPEED」

(5)

「INCHING SPEED」

(6)

「EXPANSION 1」

(7)

「PTP WEIGHT」

(8)

「EXPANSION 2」

(9)

「LOCAL COORDINATE」

(10) 「W AXIS ACCEL」 (11) 「W AXIS DECEL」 (12) 「OPTION DATA 1」 (13) 「OPTION DATA 2」 (14) 「OPTION DATA 3」 (15) 「EXPANSION 3」 (16) 「EXPANSION 4」