Page 181

CHAPTER 20 SYSTEM CONFIGURATION

CHAPTER 20

System Configuration

Controllers of HNC-580 series can control more than one robot. However, this requires work to configure the system to conform to the application (system configuration). When the Teach Pendant shows the following display, the system area is destroyed. Pressing any key automatically starts the system configuration. In cases other than this, take the steps described below to start the system configuration. System Area Destroy. Push Any Key to Start Configuration.

Fig.20.1 Display Indicating System Area Destruction With the system area destroyed, the controller may not be able to recognize the Teach Pendant. In such a case, you have to clear all the memories.

Memory All Clear Set to ON the DIP switches 1-7 (in Fig. 20.2) in CPU board inside the controller, then turn ON the power. Without any operation, turn OFF the power after 10 seconds. This process initializes all the memories inside the controller. You only have to perform this operation once when the CPU board is installed for the first time and without being energized. After this, no additional memory clearing will be necessary.

EVEN

HPC-767 ODD

→

Set to ON the DIP switches 1 - 7 1 2 3 4 5 6 7 8

O N

20.1

DIP switch

Fig.20.2 Location of DIP Switch on CPU Board

Normally this operation is unnecessary. If you perform this, all the data stored will be cleared.

20-1

Page 182

CHAPTER 20 SYSTEM CONFIGURATION

20.2

Starting Configuration (1)

Set the DIP switch 1 (in Fig. 20.3) to OFF and turn ON the power. This brings the condition ready for configuring the system. At this time, you cannot perform any regular operations at all. The only way to exit this condition is, to turn OFF the power, set the DIP switch 1 to ON and then to turn ON the power again.

EVEN

HPC-767 ODD

→

Set the DIP switch No. 1 to OFF 1 2 3 4 5 6 7 8

O N

DIP switch

Fig.20.3 Location of the DIP Switch of System Configuration

When system configuration is executed, system data and position data are cleared. System configuration should be done before setting-up the system. (2)

Carry out the steps in 2.2, “Connecting the Teach Pendant to the Controller” to display the opening screen. TEACH-PENDANT Ver.1.08 PUSH!SHIFT FUNC+CAN*

Fig.20.4 Opening Screen

Confirm that “*” is blinking at the left side bottom on the screen. If the “*” is not blinking, the controller will not recognize the following operations.

SHIFT

SHIFT

(3)

Press the LED.

key on the Teach Pendant to illuminate 『SHIFT』

(4)

Press the HIGH + CAN keys. The shaded portion of the illustration below appears. To display 「4. INITIALIZE」 on screen, press the

FUNC up DOWN spd key to scroll. SYSTEM CONFIGURATION 1.AUTO SETTING 2.MANUAL SETTING 3.OPTION DATA 4.INITIALIZE

Fig.20.5 System Configuration

20-2

Page 183

CHAPTER 20 SYSTEM CONFIGURATION

To set data, the following two ways are available: 「1. AUTO SETTING」 : Sets data when you select a robot type/model from the preset robot list given by the controller. 「2. MANUAL SETTING」 : Allows you to set each value manually one by one from motor setting, when you use a robot type not listed in the preset list. Refer to “20.3 Registering motors for axes.” 「3. OPTION DATA」 is valid only when optional specifications are included. Normally do not use this item.

(5)

cal

Press the 1 key 「1. AUTO SETTING」. The AUTO SETTING Example screen in Fig. 20.6 appears with the connectable robot types. AUTO CONFIG SETTING 1.ROBOT 1 2.ROBOT 2 3.ROBOT 3 4.ROBOT 4

Fig.20.6 Auto Setting Example (6)

Select a desired robot. The numeric keys correspond to the robots as follows: cal 1 mot 3 key: ROBOT 1 task 2 key: ROBOT 2 key: ROBOT 3 s.ed 4 key: ROBOT 4

Below shows the case of selecting 「1. ROBOT 1」. R/B 1 AUTO SETTING TYPE [GR-1800 2(X,Y) ] Enter = [END] Key

Fig.20.7 Auto Setting for ROBOT 1

(7)

Press the

END key. The message, “ENTER OK?” appears. ENTER key automatically sets the parameters preset Pressing the for each robot type. You can select a type from the following:

• GR-1800 • GR-1800 • GR-1800

2 (X,Y) 3 (X,Y,Z) 4 (X,Y,Z,W)

20-3

Page 184

CHAPTER 20 SYSTEM CONFIGURATION

20.3

Registering Motors for Axes Register motors used for each axis by specifying in motor/driver configuration mode. Up to 16 motors can be registered. The items to be specified are listed in the table below. Table 20.1 Motor Amplifier/Driver Configuration Setting Items Keys for Entry

Item

Description dec SHIFT → INC dec INC

MOTOR NO.

key: Up, key: Down Selects 01 up to 16. Each number represents the number of the servo amplifier/driver. (The servo a amplifier/driver and the motor are paired.) io SEL

MOTOR TYPE key Selects one of the following: ・ ABS (absolute) ・ INC. (incremental) ・ NOT USE (not used) *

MOTOR REV.

*

ENCPULSE key

Numeric keys: 0 up to 9 key Specifies a number of pulses per motor revolution. setting is 2048. *

LEAD key

Numeric keys: 0 up to 9 key Specifies the maximum operating speed of motor.

Standard key

Numeric keys: 0 up to 9 key Specifies a value of lead in “mm” per motor revolution for linear type, and specifies gear ratio for rotary type. io SEL

OVERRUN key Selects either of the two below: ・ USED (Validates OVERRUN sensors.) ・ NOT USED (Invalidates OVERUN sensors.) io SEL

ORIGIN key Selects either of the two below: ・ USED (Validates ORIGIN sensor.) ・ NOT USED (Invalidates ORIGIN sensor.) io SEL

AXIS TYPE key Selects either of the two below: ・ LINEAR (for linear actuators) ・ROTARY (for rotary actuators) io SEL

AXIS REV.

key Selects either of the two below: ・ NORMAL (normal revolution) ・ INVERSE (reversed revolution) *

MOTOR CODE EXPAND 2 EXPAND 1 key

Numeric keys: 0 up to 9 key Specifies a motor code in decimal notation. (For codes, refer to AOOEBDUX D, “Motor Code.”) For expansion For expansion

20-4

Page 185

CHAPTER 20 SYSTEM CONFIGURATION How to specify data and register motors manually are described below. (1)

With the System Configuration screen displayed as in Fig.20.5, task press the 2 key 「2. MANUAL SETTING」. The screen display changes as shown below. MANUAL SETTING 1.MOTOR/DRIVER 2.ROBOT CONFIG

Fig.20.8 Manual Setting (2)

cal

Press the 1 key 「1. MOTOR/DRIVER」. The shaded portion of the illustration below appears. To display 「ENC. PULSE」 and the following pages in sequence, press the up DOWN key to scroll the screen.

MOTOR/DRIVER CONFIG MOTOR NO 01 MOTOR TYPE [ABS. ] MOTOR REV. 3600 ENC.PULSE 02048 LEAD 010.000 OVERRUN [NOT USED] ORIGIN [NOT USED] AXIS TYPE [LINEAR ] AXIS REV. [NORMAL ] MOTOR CODE 049 EXPAND 2 000 EXPAND 1 000 Enter = [END] Key

Fig.20.9 Motor Driver Configuration (3)

Specify a value for each item, referring to the Table 20.1, Motor Amplifier/Driver Configuration Setting Items. ① Enter a value for each item and press the message, “ENTER OK?” appears. ② To set the value, press the

(4)

ENTER

ENTER key. The key again. END

After setting for all the items, press the key. The message, “SAVE CONFIG OK?” is displayed. When everything is OK, press the

ENTER key. If you do not wish to save the settings, press the spd CAN

(5)

(6)

key to cancel this process. When the setting is completed, “COMPLETED” appears. When entered data are incorrect, the data will not be set with an error message on display. Refer to Table 20.3, Configuration Error Message List When the setting has been successfully completed, press the key to go back to the Manual Setting screen, Fig.20.8.

END spd CAN

Be sure to press the key after entering values for the items. Failing to do so will invalidate the values entered.

20-5

Page 186

CHAPTER 20 SYSTEM CONFIGURATION

20.4

Assigning Motors to Robot Axes In this section, motors registered in 20.3, “Registering Motors for Axes” are assigned to individual axes of the robot to be used in robot configuration mode. The items to set are given below. Table 20.2 Robot Configuration Setting Items Keys for Entry Description

Item io SEL

R/B TYPE

A(X)AXIS NO. B(Y)AXIS NO. Z AXIS NO. W AXIS NO. R AXIS NO. C AXIS NO. ACCEL A ACCEL B ACCEL Z ACCEL W ACCEL R ACCEL C key Select the robot type. For any Cartesian robot, select [MB-ZWR]. ・AR ・AR-K ・AR-V ・MB ・MB-ZW ・MB-ZWR ・NOT USED Numeric keys Enters the motor No. for A-Axis (X-Axis for Cartesian type). *) Numeric keys Enters the motor No. for B-Axis (Y-Axis for Cartesian type). *) Numeric keys Enters the motor No. for Z-Axis. *) Numeric keys Enters the motor No. for W-Axis. *) Numeric keys Enters the motor No. for R-Axis. *) Numeric keys Enters the motor No. for C-Axis. *) Numeric keys Enters accelerating/decelerating time for A-Axis. Numeric keys Used for Enters accelerating/decelerating time for B-Axis. calculation of Numeric keys 「ACCEL」 group, by Enters accelerating/decelerating time for Z-Axis. selecting Numeric keys 「RESPONSE」→ Enters accelerating/decelerating time for W-Axis. 「ACCEL」 in System Numeric keys Parameter menu. Enters accelerating/decelerating time for R-Axis. Numeric keys Enters accelerating/decelerating time for C-Axis. io SEL

I/O TYPE

REMOTE I/O ID

MAX POSITION key Select the I/O type for REMOTE I/O. ・CC Link ・OPTION1 ・OPTION2 ・OPTION3 ・HIRATA ・DeviceNet (CompoBus/D) Numeric keys Select the ID for using the REMOTE I/O product of HIRATA. Numeric keys Enters the maximum number of position data by the 1000.(The maximum setting is 4000; 8000 for all the robots) When 1000 is set, the valid address range is from 0 to 999. io SEL key Select a robot's operation range type (stroke). ・ NORM: <10m ・ SHORT: <1m ・ LONG: >10m to <100m ・ SUPER: ≧100m *) Enter “00” for an axis not to be used. SCALE FACTOR

20-6

Page 187

CHAPTER 20 SYSTEM CONFIGURATION

How to specify data and assigning motors are described below. (1)

With the Manual Setting screen displayed as in Fig. 20.8, press the task 2 key 「2. ROBOT CONFIG」. The screen display changes as shown below. ROBOT CONFIGURATION 1.ROBOT 1 2.ROBOT 2 3.ROBOT 3 4.ROBOT 4

Fig.20.10 Selection of Robots on ROBOT CONFIGURATION Screen (2)

(3)

Select a desired robot for which you are going to set values. The numeric keys correspond to the robots as follows: cal 1 key: ROBOT 1 task 2 key: ROBOT 2 mot 3 key: ROBOT 3 s.ed 4 key: ROBOT 4 cal

Press the 1 key 「1. ROBOT 1」. The shaded portion of the illustration below appears. To display 「Z AXIS NO.」 and the following screen in sequence, press the up DOWN to scroll the screen.

R/B 1 CONFIGURATION R/B TYPE [MB-ZW ] A(X)AXIS NO. 01 B(Y)AXIS NO. 02 Z AXIS NO. 03 W AXIS NO. 04 R AXIS NO. 05 C AXIS NO. 06 ACCEL A 0.20 ACCEL B 0.20 ACCEL Z 0.20 ACCEL W 0.20 ACCEL R 0.20 ACCEL C 0.20 I/O TYPE [HIRATA ] REMOTE I/O ID 00 MAX POSITION 1000 SCALE FACTOR [NORM ] Enter = [END] Key

Fig.20.11 Robot Configuration (4)

Specify a value for each item, referring to the Table 20.2, Robot Configuration Setting Items. ① Enter a value for each item and press the message, “ENTER OK?” appears. ② To set the value, press the

20-7

ENTER

ENTER key again.

key. The

Page 188

CHAPTER 20 SYSTEM CONFIGURATION

(5)

END

After setting for all the items, press the key. The message, “SAVE CONFIG OK?” is displayed. When everything is OK, press ENTER the spd CAN key. If you do not wish to save the settings, press the key to cancel this process.

(6)

When the data setting is completed, “COMPLETED” appears. When entered data are, the data will not be set with an error message on display. Refer to Table 20.3, Configuration Error Message List.

(7)

Press

(8)

When all the settings have been completed, execute as described later in 20.7, “Ending Configuration,” to start the system again.

spd CAN key to go back to the Manual Setting screen, Fig. 20.8.

END

Be sure to press the key after entering values for the items. Failing to do so will invalidate the values entered. Below is the Configuration Error Message List. Table 20.3 Configuration Error Message List Message INCOMPLETE ADDRESS ERROR ADDRESS OVER FLOW ALREADY USED A AXIS ALREADY USED B AXIS ALREADY USED Z AXIS ALREADY USED W AXIS ALREADY USED R AXIS ALREADY USED C AXIS

Description Operation is canceled in the middle. Improper address setting The total number of addresses robots use has exceeded the maximum number. Other robot already uses the motor specified for A-Axis. Other robot already uses the motor specified for B-Axis. Other robot already uses the motor specified for Z-Axis. Other robot already uses the motor specified for W-Axis. Other robot already uses the motor specified for R-Axis. Other robot already uses the motor specified for C-Axis.

NO REGISTRY A AXIS

The motor specified for A-Axis has not been registered.

NO REGISTRY B AXIS

The motor specified for B-Axis has not been registered.

NO REGISTRY Z AXIS NO REGISTRY W AXIS NO REGISTRY R AXIS

The motor specified for Z-Axis has not been registered. The motor specified for W-Axis has not been registered. The motor specified for R-Axis has not been registered.

20-8

Corrective Action Complete the operation. Correct the 「MAX POSITION」 setting. Correct the 「MAX POSITION」 setting. Correct the 「A(X)AXIS NO.」 setting. Correct the 「B(Y)AXIS NO.」 setting. Correct the 「Z AXIS NO.」 setting. Correct the 「W AXIS NO.」 setting. Correct the 「R AXIS NO.」 setting. Correct the 「C AXIS NO.」 setting. Set the motor No. for 「MOTOR NO.」 Then, set for 「A(X)AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「B(Y)AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「Z AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「W AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「R AXIS NO.」

Page 189

CHAPTER 20 SYSTEM CONFIGURATION Message

DATA ERROR [LEAD]

Description The motor specified for C-Axis has not been registered. The number of revolutions is incorrect. The number of pulses is incorrect. The lead value is incorrect.

DATA ERROR [CODE]

The motor code is incorrect.

ROBOT TYPE ERROR

The robot type is incorrect.

NO REGISTRY C AXIS DATA ERROR [REV.] DATA ERROR [PULSE]

INVALID AXIS NUM ACCEL/DECEL ERROR

20.5

Motor has not been assigned to the axis, or motor that can be assigned is not found. No accelerating/decelerating time has been set.

Corrective Action Set the motor No. for 「MOTOR NO.” Then, set for 「C AXIS NO.」 Correct the 「MOTOR REV.」 setting. Correct the 「ENCPULSE」 setting. Correct the 「LEAD」 setting. Correct the 「MOTOR CODE」 setting. Correct the 「R/B TYPE」 setting. Assign motors by specifying motor code for 「A(X) AXIS NO.」 up to 「C AXIS NO.」 Set for all the items starting from 「ACCEL A」 to 「ACCEL Z」.

Data for Optional Specifications When the System Configuration screen as shown in Fig. 20.5 is retrieved, mot pressing the 3 key 「3. OPTION」 displays the data setting items for optional specifications. Normally, you do not have to use this group.

20.6

Initializing the Configuration When the System Configuration screen as shown in Fig.20.5 is retrieved, pressing the s.ed 4 key 「4. INITIALIZE」 displays “INITIALIZE OK?” on the message line. To initialize the system configuration, press the key.

ENTER

This initializing operation clears the entire system configuration. Never carry out this operation after the system set-up, unless data are destroyed.

20.7

Ending Configuration Steps for ending configuration are described below. (1)

Turn OFF the power.

(2)

Set to ON the DIP switch 1 on CPU board (shown in Fig. 20.3) in the controller.

(3)

After 10 seconds, turn ON the power again.

(4)

The screen display returns to Opening Screen, as shown in Fig. 20.4.

20-9

Page 190

CHAPTER 20 SYSTEM CONFIGURATION

20.8

Checking the Settings You can start system configuration without changing the DIP switch setting. The procedure for checking the system configuration data is given below. (1)

Carry out the steps in 2.2, “Connecting the Teach Pendant to the Controller” and retrieve the screen as illustrated below for selecting a robot number. SELECT ROBOT NUMBER 1.ROBOT1 2.ROBOT2 3.ROBOT3 4.ROBOT4

Fig.20.12 Screen for Selecting Robot Number (2)

Select ROBOT 1.

(3)

Press the Pendant.

(4)

Press the HIGH + 1 keys simultaneously. The shaded portion of the illustration, Fig.20.13, Robot Calculation Mode, appears on the

FUNC HIGH

+

F1 keys to set KEY-IN mode for the Teach cal

FUNC screen. To display 「7. CONFIG MODE」, press the scroll the screen.

up DOWN key to

ROBOT CALCULATE MODE 1.CALC. 2.OFFSET 3.MEMORY 4.DISP 5.SERVO 5.BP/ZONE 7.CONFIG MODE

Fig.20.13 Robot Calculation Mode

(5)

Pressing the s.g 7 key 「7. CONFIG MODE」 displays “CHANGE

OK?” on the message line. Then, press the

ENTER key.

(6)

When “Reboot Controller.” appears on the message line, turn OFF the power on the controller. Thirty seconds after this, turn ON the power again.

(7)

The system configuration mode is entered. Start the operation from the step (2) in 20.2, “Starting Configuration.”

(8)

Check the contents of the system configuration settings.

(9)

Turn OFF the power. After thirty seconds, turn ON the power again to exit the system configuration mode.

20-10