Page 191

CHAPTER 21 INITIALIZING SYSTEM DATA

CHAPTER 21 21.1

Initializing System Data

Outline System data are semi-fixed data required to operate robots, specifically they are the data intrinsic to robots used and data to optimize the robots accordingly with the system. It is not necessary to modify the data after the robots are incorporated into the system. However, incorrect or inappropriate values cause malfunctioning or failure of the robots. Initialize system data only when:

z System data are destroyed due to running out of battery power. z System configuration is executed. Before starting robot operation, always be sure to specify correct data and record such set values. Initializing system data also initializes servo parameters at the same time and the default value will be set automatically to the system data.

21.2

Setting Default Values to the System Setting default values to the system is described below. FUNC HIGH

F1 keys to set the Teach Pendant in KEY-IN

(1)

Press the mode.

(2)

Press the

SHIFT key to illuminate『SHIFT』LED.

(3)

Press the

READ key while pressing the

(4)

“DEFAULT COPY OK?” appears on the message line. To execute

SHIFT

+

FUNC HIGH key.

ENTER copying the default values onto the system, press the key. If you do not wish to copy the default values, press any key other than the

ENTER key.

After copying default values onto the system, be sure to set the system data supplied upon delivery of the system. Or, when system data list attached to the controller is available, set such data. Inside the robot memory, position data are stored as values on X-Y coordinates. When the robot performs positioning, the system converts values on X-Y coordinates into pulses allotted to axes, based on initial data (「INITIAL A」-「INITIAL C」) and arm lengths (「LENGTH A」-「LENGTH C」) in 「AR TYPE ADJUST」 reached from 「ADJUST」 in System Generation menu.

21-1

Page 192

CHAPTER 21 INITIALIZING SYSTEM DATA For this reason, if such initial data and/or arm lengths are changed after teaching, the original positions cannot be reproduced. For the following items, default copying (copying of the default values) will not be executed if the current value of each item is within a permissible variation range of the default value. However, it is necessary to check the following data after executing the default copy. Initial data: default value : ±90°(varies depending on the robot type) Arm length: default value : ±90mm (varies depending on the robot type) Direction of A-CAL i

: 0 (PLUS) or 1 (MINUS)

AXIS TYPE ii

: 0 (NOT USED) or 1 (USED)

AXIS SELECT iii

: 0 (NOT HOLD) or 1 (HOLD)

When “SYSTEM DATA ERROR” occurs, be sure to copy the default values on to the system first and then to edit the data. Also, after data editing, turn ON the power again.

21.3

Setting for SCARA (Horizontal MultiArticulated) Robot In cases of a SCARA robot, the steps described below should be performed after initializing the system data. (1)

Set for the 「A-CAL DIR. A」 to 「A-CAL DIR. B」 so that the counterclockwise direction corresponds to the “+” (PLUS) direction of A-CAL when A, B and W-Axes of the SCARA robot are displayed in angle. 「A-CAL DIR. A」 to 「A-CAL DIR. B」 can be reached by selecting 「ORIGIN」→「AXIS DIRECTION」 in System Generation menu.

(2)

The pose for A-CAL is as illustrated below. When the arm interferes, A-CAL should be performed axis by axis.

Fig.21.1 Pose for A-CAL i ii iii

: 「ORIGIN」→「AXIS DIRECTION」→「A-CAL DIR. A」→「A-CAL DIR. C」 in System Generation menu : 「ORIGIN」→「AXIS SELECT」→「A AXIS TYPE」→「C AXIS TYPE」in System Generation menu : 「ORIGIN」→「AXIS SELECT」→「A AXIS SEL」→「C AXIS SEL」 in System Generation menu

21-2

Page 193

CHAPTER 21 INITIALIZING SYSTEM DATA

(3)

Set for the 「INITIAL A」 to 「INITIAL B」 so that the respective values of A, B and W-Axes become 0 when the robot poses as shown below. 「INITIAL A」 to 「INITIAL B」 can be reached by selecting 「ORIGIN」→「AXIS DIRECTION」 in System Generation menu.

Fig.21.2 Pose for Setting 「INITIAL A」-「INITIAL C」 Table 21.1 Case of AR-ZL850 Example 「INITIAL A」-「INITIAL C」 「LENGTH A」-「LENGTH C」 「UPPER LMT A」-「UPPER LMT C」 「LOWER LMT A」-「LOWER LMT C」

21-3

A -110 850 110 -110

B -155 650 155 -155

Z 0 0 3000 0

W 0 0 360 0

Page 194

CHAPTER 22 INITIALIZING POSITION DATA

CHAPTER 22

Initializing Position Data

Initialize position data of the robot when: Steps for initializing robot position data are described below.

z Position data are destroyed. z System configuration is executed and system data is initialized. (1)

FUNC p.ed

Press the HIGH + 5 keys to block operation mode for position memory. The applicable position addresses are between address 0 and the maximum address number specified by 「LIMIT」→「ADDRESS MAX」→「ADDRESS MAX」 in System Generation menu. The shaded portion of the opening screen in Fig.22.1 appears. To display 「MODE COMMAND」 and the following items in sequence, press the up DOWN key to scroll the screen.

POSITION COMMAND START ADDRESS 0000 END ADDRESS 0000 SET ADDRESS 0000 MODE COMMAND [MOVE] Push END Key !!

Fig.22.1 Block Operation Mode (2)

Specify 0 in the space next to 「START ADDRESS」 and specify in the space next to 「END ADDRESS」 the value set for 「LIMIT」→ 「ADDRESS MAX」→「ADDRESS MAX」 in System Generation menu. It is not necessary to specify any value for 「SET ADDRESS」. Enter for respective items and press the each entry to set the data.

(3)

ENTER key twice after

Specify “INIT” for 「MODE COMMAND」. Press the ENTER io SEL key until “INIT” is displayed in the space. Press the key twice to set the value. END

(4)

Press the key. Then, "Position INIT Ok?" is displayed.

(5)

To execute the INIT command, press the

(6)

When "INIT Completed!!" appears, the command has been executed.

(7)

Initialized position data are shown below. 0010 M?? F99 X 0000.00 Y Z 0000.00 W R 0000.00 C

ENTER key.

S00 L 0 0000.00 0000.00 0000.00

Fig.21.1 Initialized Data (of 6-Axis Specification)

22-1

Page 195

CHAPTER 23 MESSAGE

CHAPTER 23

Message

The following tables are the messages displayed on the message line on the Teach Pendant. Also, error messages are displayed. Refer to these messages for trouble-shooting.

23.1

General Message Table 23.1 General Message Message A-CAL COMPLETE A-CAL INCOMPLETE A-CAL OK? AXIS SELECT OFF CHECK SPEED DATA > COMPLETE COMPLETED !! DEFAULT COPY OK? DELETE OK? END POINT END WRITE OK?

ENTER OK?

Mode TEACH CHECK TEACH CHECK AGING TEACH CHECK TEACH CHECK CHECK CHECK KEY-IN KEY-IN CHECK CHECK KEY-IN TEACH KEY-IN TEACH CHECK

INCOMPLETE

CHECK

INSERT OK?

KEY-IN TEACH

Description A-CAL completed normally. 『A-CAL』 LED light up. A-CAL incomplete. Error is occurred during A-CAL execution. Intend to perform the aging before A-CAL completion. The

A-CAL key is pressed to perform A-CAL.

No axis is selected for A-CAL. Sets the speed of the robot in CHECK mode. Positioning complete normally. Completes memory card transaction. Copies the system data default value in KEY-IN mode. del

SHIFT

+ INS keys are pressed. The Intend to perform the positioning to END point in CHECK mode. The The

END key is pressed.

ENTER

Press the key is pressed. ENTER key again for data input.

START

The key is pressed in the middle of positioning. Error is occurred during positioning. The

23-1 del INS key is pressed.

Page 196

CHAPTER 23 MESSAGE

23.2

Warning Message Table 23.2 Warning Message Message

Mode

A-CAL WARNING !!

TEACH CHECK

AGING ABORT AGING STOP(Start) ENC BATTERY WARNING! POSITIONING WARNING STOP ON SYS BATTERY WARNING!

i ii

AGING AGING TEACH CHECK ON-LINE TEACH CHECK ON-LINE TEACH CHECK ON-LINE TEACH CHECK ON-LINE

Description A- CAL is not executed correctly. “A-CAL ERR.------” error occurrence. System data 「A-CAL CHECK」 i is set to “1.” Aging is interrupted. Aging is completed for the aging count. Encoder battery voltage becomes low. “POS ERROR ******” error occurrence. System data 「POS ERROR SELECT」 ii is set to “1.” DI STOP signal is ON. Prohibit the axis operation. System battery voltage on the CPU board becomes low.

: System Generation, 「MAINTENANCE」→「MAINTENANCE DATA」→「A-CAL CHECK」 : System Generation, 「MAINTENANCE」→「MAINTENANCE DATA」→「POS. ERROR SEL」

23-2

Page 197

CHAPTER 23 MESSAGE

23.3

Error Message Table 23.3 Error Message Error Message

A-CAL INCOMLETE

Mode

Description

TEACH CHECK A-CAL is not executed normally. ON-LINE

Corrective Action Refer to Chapter 3, “A-CAL (Automatic Calibration).”

ACAL ERR *0 Not Find CAL is not executed normally. “*” is ACAL ERR *1 Not Off correspond the each axis. ACAL ERR *2 Other On TEACH A…X(A)-Axis ACAL ERR *3 Not Zero CHECK B…Y(B)-Axis Refer to Ch3.4, “A-CAL Related Error.” ACAL ERR *4 Lower ON-LINE ACAL ERR *5 Upper Z…Z-Axis, W…W-Axis ACAL ERR *6 Minus R…R-Axis, C…C-Axis ACAL ERR *7 Error Set for all the items starting from ACCEL/DECEL ERROR No accelerating/decelerating time has 「ACCEL A」 to 「ACCEL Z」. (System configuration error) been set. ADDRESS ERROR Improper address setting Correct the 「MAX POSITION」 setting. (System configuration error) TEACH The value for the input or motion address Set the large value for 「ADDRESS ADDRESS ERROR CHECK is out of range in the system data, MAX」. Correct the designated address. ON-LINE 「ADDRESS MAX」 i . ADDRESS OVER FLOW The total number of addresses robots use Correct the 「MAX POSITION」 setting. (System configuration error) has exceeded the maximum number. ALREADY USED A AXIS Other robot already uses the motor speciCorrect the 「A(X)AXIS NO.」 setting. (System configuration error) fied for A-Axis. ALREADY USED B AXIS Other robot already uses the motor speciCorrect the 「B(Y)AXIS NO.」 setting. (System configuration error) fied for B-Axis. ALREADY USED C AXIS Other robot already uses the motor speciCorrect the 「C AXIS NO.」 setting. (System configuration error) fied for C-Axis. ALREADY USED R AXIS Other robot already uses the motor speciCorrect the 「R AXIS NO.」 setting. (System configuration error) fied for R-Axis. ALREADY USED W AXIS Other robot already uses the motor speciCorrect the 「W AXIS NO.」 setting. (System configuration error) fied for W-Axis. ALREADY USED Z AXIS Other robot already uses the motor speciCorrect the 「Z AXIS NO.」 setting. (System configuration error) fied for Z-Axis. The designated value is out of the operational area of the robot. “*” is one of the AREA ERROR ****** Check the value of the System GeneraKEY-IN numbers from 0-3. tion, 「LIMIT」→「AREA LIMIT」 and TEACH 0…Normal, “******” is designates as CHECK 1…Over the lower limit input the value which is inside of the X(A), Y(B), Z, W, R,C-Axis ON-LINE operational area. status in the sequence. 2…Over the upper limit 3…Over the both limit Address Error KEY-IN Address is abnormal. (Automatic calculation error) Axis Not Used The setting for the axis, for which calculaKEY-IN Specify the proper value. (Automatic calculation error) tion is made, is “NOT USED.” Try again to write. KEY-IN BCC WRITE ERROR !! Error is occurred during writing the check When the error repeats, the memory card TEACH (Memory card abnormal) character in the file. itself has been damaged. Use another CHECK card. KEY-IN Execute the FORMAT command in CARD BCC ERROR The system area in the memory card is TEACH UTILITY mode. Refer to 13.7.5, “FOR(Memory card abnormal) destroyed. CHECK MAT Command.” KEY-IN CARD FULL !! You attempted to save more information TEACH Delete unnecessary files and save again. (Memory card abnormal) than the card storage capacity CHECK KEY-IN CARD NOT READY !! TEACH No memory card in place. Insert a memory card properly. (Memory card abnormal) CHECK i

: System Generation, 「LIIMIT」→「ADDRESS MAX」→「ADDRESS MAX」

23-3

Page 198

CHAPTER 23 MESSAGE

Error Message CPU LOW BATTERY DATA CHECK ERROR !! (Memory card abnormal) DATA ERROR [CODE] (System configuration error) DATA ERROR [LEAD] (System configuration error) DATA ERROR [PULSE] (System configuration error) DATA ERROR [REV.] (System configuration error) DRIVER ERR.****** “******” is designates as X(A), Y(B), Z, W, R, C-Axis status in the sequence. DRIVER NOT ONLINE DRIVER TIME OUT

Mode

Description

Corrective Action

CHECK Battery voltage on the CPU board beReplace the battery. ON-LINE comes low. Battery type: H-3339 KEY-IN Try again to write. When the error Either the independent check character or TEACH repeats, the memory card itself has been data in the file are destroyed. CHECK damaged. Use another card. The motor code is incorrect.

Correct the 「MOTOR CODE」 setting.

The lead value is incorrect.

Correct the 「LEAD」 setting.

The number of pulses is incorrect.

Correct the 「ENCPULSE」 setting.

The number of revolutions is incorrect.

Correct the 「MOTOR REV.」 setting.

Error is occurred in the servo ampliTEACH fier/driver. CHECK “*” is one of the numbers 0 and 1. ON-LINE 0…Normal, 1…Error occurrence TEACH CHECK Servo amplifier/driver disconnection ON-LINE TEACH CHECK Servo amplifier/driver disconnection ON-LINE

Check the servo amplifier/driver.

Check the cable connection. Check the cable connection.

DUPLICATE FILE NAME (Memory card abnormal)

The same file name is specified as the TEACH SOURCE and DESTINATION when CHECK copying .

Change the DESTINATION file name to a different one form the SOURCE file name. Refer to 13.6.4, “COPY Command.”

EMERGENCY STOP

TEACH CHECK Inputted Emergency Stop signal ON-LINE

Release Emergency Stop status.

Encoder battery voltage becomes low. CHECK “*” is one of the numbers 0 and 1. TEACH 0…Normal, ON-LINE 1…Error occurrence

Replace the battery. Battery type: R086-12-38

ENC BATTERY ****** “******” is designates as X(A), Y(B), Z, W, R, C-Axis status in the sequence. FAT WRITE ERROR !! (Memory card abnormal) FILE ALREADY OPEN (Memory card abnormal) FILE BAD ALLOCATION (Memory card abnormal) FILE CAN NOT OPEN (Memory card abnormal) FILE HANDLE FULL !! (Memory card abnormal) FILE ID ERROR !! (Memory card abnormal) FILE ID FULL !! (Memory card abnormal) FILE ID WRITE ERROR (Memory card abnormal) FILE NOT CLOSED (Memory card abnormal)

KEY-IN TEACH CHECK KEY-IN TEACH CHECK KEY-IN TEACH CHECK KEY-IN TEACH CHECK KEY-IN TEACH CHECK KEY-IN TEACH CHECK KEY-IN TEACH CHECK KEY-IN TEACH CHECK KEY-IN TEACH CHECK

FAT cannot be written in. You have opened again the file that had already opened. FAT has been destroyed.

Try again to write. When the error repeats, the memory card itself has been damaged. Use another card. Execute FORMAT command in UTILITY mode. Refer to Ch13.7.5, “FORMAT Command.”

You attempted to access a file that was not opened.

-

Too many files have been opened.

-

The check characters verifying the file information do not match.

Delete the file using DELETE command. Refer to 13.6.5, “DELETE Command.” Delete unnecessary files and try again.

You attempted to store more files than the defined number of files. Refer to 13.7.5, Delete unnecessary files and try again. “FORMAT Command.” Try again to write. When the error The check character to verify the file repeats, the memory card itself has been information cannot be written in. damaged. Use another card. You attempted to execute UTILITY command with files opened.

23-4

Close all the files that are opened.

Page 199

CHAPTER 23 MESSAGE

Error Message FILE NOT FOUND !! (Memory card abnormal) FORMAT ERROR !! (Memory card abnormal)

Mode

Description

KEY-IN TEACH The specified file cannot be found. CHECK KEY-IN TEACH The memory card is not initialized. CHECK

Corrective Action Check for the correct file name. Execute FORMAT command in UTILITY mode. Refer to 13.7.5, “FORMAT Command.”

INCOMPLETE (System configuration error)

-

Operation is canceled in the middle.

Complete the operation.

INVALID AXIS NUM (System configuration error)

-

Motor has not been assigned to the axis, or motor that can be assigned is not found.

Assign motors by specifying motor code for 「A(X) AXIS NO.」 up to 「Z AXIS NO.」 Check if the set data and teaching positions are appropriate. Then, specify correct data or teach again.

Incompleted!! KEY-IN Normal calculation is not possible. (Automatic calculation error) Initial Data Error KEY-IN Initial data is abnormal (Automatic calculation error) Mode Error The selected mode is not KEY-IN, KEY-IN (Automatic calculation error) TEACH, CHECK mode. NO REGISTRY A AXIS The motor specified for A-Axis has not (System configuration error) been registered. NO REGISTRY B AXIS (System configuration error)

The motor specified for B-Axis has not been registered.

NO REGISTRY C AXIS (System configuration error)

The motor specified for C-Axis has not been registered.

NO REGISTRY R AXIS (System configuration error)

The motor specified for R-Axis has not been registered.

NO REGISTRY W AXIS (System configuration error)

The motor specified for W-Axis has not been registered.

NO REGISTRY Z AXIS (System configuration error) OVERRUN ****** “******” is designates as X(A), Y(B), Z, W, R,C- Axis status in the sequence.

Initialize again. Change the mode. Set the motor No. for 「MOTOR NO.」 Then, set for 「A(X)AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「B(Y)AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「C AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「R AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「W AXIS NO.」 Set the motor No. for 「MOTOR NO.」 Then, set for 「Z AXIS NO.」

The motor specified for Z-Axis has not been registered. The robot is in overrun area. “*” is one of the numbers from 0-3. TEACH 0…Normal, Move the robot to inside of the operationCHECK 1…ORIGIN sensor side al are, and check the position data. ON-LINE 2…OVERRUN sensor side 3…ORIGIN/OVERRUN sensor Each number describes the sensor is ON.

P1-P2 Length Error KEY-IN Distance between P1 and P2 is too short. (Automatic calculation error) P1-P3 Length Error KEY-IN Distance between P1 and P3 is too short. (Automatic calculation error) Positioning is not completed even the robot reached at the target position. Excessive load POS ERROR ****** Excessive acceleration/deceleration CHECK Improper adjustment for the servo ampli“******” is designates as ON-LINE fier/driver. X(A), Y(B), Z, W, R, C-Axis “d” is one of the numbers 0 and 1. status in the sequence. 0…Normal, 1…Error occurrence POSITION DATA ERROR Reading data from the memory card is ON-LINE (Memory card abnormal) failed during automatic operation. Positioning is not able to performed. Designated speed and acceleraCHECK POSITIONING ERROR tion/deceleration at the last position is ON-LINE exceeding. Servo gain is small. R-Offset Data Error KEY-IN Rotary-offset value has been abnormal. (Automatic calculation error) ROBOT TYPE ERROR The robot type is incorrect. (System configuration error)

23-5

Teach again. Teach again.

Adjust the servo parameters. Check if any external pressure (Pneumatic hose, cable) is exist.

Check the designated data is stored to the memory card correctly. Adjust servo parameter. Slow down the acceleration/deceleration. Slow down the designated speed (Fcode) at the last position. Teach again. Correct the 「R/B TYPE」 setting.

Page 200

CHAPTER 23 MESSAGE

Error Message SERVO DATA ERROR SERVO ON ERROR STATUS ERROR

Mode

Description

TEACH Servo Parameters are abnormal or not be CHECK entered. ON-LINE TEACH CHECK Unable to be in servo lock condition ON-LINE TEACH Internal processing error CHECK Error which is not supported is occurred. ON-LINE

SYSTEM DATA ERROR

TEACH The system data is not correct or not CHECK entered. ON-LINE

SYSTEM ERROR

TEACH CHECK Internal processing error ON-LINE

Teaching Data Error KEY-IN (Automatic calculation error) KEY-IN UNDEFINED ERROR !! TEACH (Memory card abnormal) CHECK KEY-IN VERIFY ERROR !! TEACH (Memory card abnormal) CHECK KEY-IN WRITE PROTECT !! TEACH (Memory card abnormal) CHECK

Corrective Action Copy the default value of system data. Enter the correct value to the Servo Parameters. Check the power for the servo amplifier/driver control. spd

Cancel with the CAN key. Then, contact your distributor. Copy the default value of the system data. The, enter the required value of the system data. Refer to 17.3.5, “Setting Default Values for System Data.” Contact your distributor.

Teaching data is abnormal.

Teach again.

An unexpected error has occurred.

Re-try the operation. When the error repeats, contact your distributor.

The system failed to compare the file information for verification. The memory Replace the card with a new one. card may be damaged. Check the information stored on the card. You attempted to write with the writeIf editable, turn OFF the write-protect protect switch turned ON. switch.

23-6