Page 21
CHAPTER 2 CONNECTING THE TEACH PENDANT
2.9
Function Mode FUNC
The mode selected by the HIGH with blue colored key, such as the io SEL k.in M seq A k.out S local F cal 1 to key 9
, m.c M.OUT
, , , , , and keys, is the function mode. This mode can be activated in any other mode. However, in order to display it, the display stage on the Teach Pendant must be in the home stage described in item (2) below. In ON-LINE mode, the data is displayed but no data cannot be input.
(1)
FUNC cal + HIGH 1
[cal] keys (calculation)
Calculates the robot individual characteristic values and the offset value or creates position data (palletizing software). Refer to Chapter 12 , “Automatic Creation of Position Data & Parameters” for details.
(2)
task FUNC + 2 [task] keys (task) HIGH
Changes the display on the Teach Pendant. There are thirteen screens. Every time pressing these keys, the display screen is switched in order. The first display is called “home screen.” Table 2.7 Display Screens (task) Screen No. 1 2
3 4 5 6 7 8
Name
Description
Home Positioning history 「POSITIONING HISTORY」 Communication monitor 「RS232 MONITOR」 Speed monitor 「SPEED MONITOR」 Current monitor 「CURRENT MONITOR」 Servo status 「STATUS MONITOR」 Servo alarm 「SERVO ALARM」 System information 「SYSTEM MONITOR」
9
Expanded interface 「EXINTERFACE MONITOR」
10
Maintenance monitor 1 「GA1045 MONITOR」
2-14
Normal display Displays nine of the history address in order. Refer to Chapter11, “Positioning Address History” for details. Input/output data communicated by RS232C. (Only for HIRATA maintenance) Speed for each axis. (Only for HIRATA maintenance) Current used by each axis. Current upper limits is 100%. (Only for HIRATA maintenance) Servo status of each axis (Only for HIRATA maintenance) Contents of the servo alarm for each axis (Only for HIRATA maintenance) The system information. Refer to the following page for details. Expanded interface is displayed when specifying the I/O type (“CC-Link” or “CompoBus/D (DeviceNet)”) in system configuration. It will not be displayed unless the I/O type is specified. (Only for HIRATA maintenance) (Only for HIRATA maintenance)
Page 22
CHAPTER 2 CONNECTING THE TEACH PENDANT Screen No.
11
Name
Description Errors are stored to error history from 1 to F. Stores past 15 errors. The error history 1 is the latest error, and it will be sift up in the order when the error is occurred. Three errors are displayed on the screen at one time.
Alarm history 「ALARM HISTORY」 io
12
Servo communication error monitor 「SERVO ERROR COUNT」
13
Maintenance monitor 2 「AUTO EVENT」
Press the SEL key to scroll and display the following screen. (Only for HIRATA maintenance) Monitors how many times an error is occurred for the each axis servo LINK communication. (Only for HIRATA maintenance) (Only for HIRATA maintenance)
FUNC task
The function mode, except that selected by [task] key ( HIGH + 2 ), is displayed on home the screen. Press the from all others.
spd CAN key to return to home screen
Following figure shows the details of system information (Screen No.: 8) . There are four screens. SYSTEM MONITOR VERSION NC MODE RB MODE
Press the io SEL
1/4 5.02.007B MANUAL KEY-IN key
SYSTEM MONITOR 2/4 SCALE NORM I/O TYPE REMOTE 00 ID 00 00 00 00 00 00
Press the io SEL key
SYSTEM MONITOR VOLTAGE BATTERY MEM BATTERY
Press the io SEL
3/4 OK OK OK key
SYSTEM MONITOR HOUR METER RB TYPE EN OK OK OK
4/4 0000000H AR-K ** **
Fig.2.8 Display Switching (task)
2-15
Page 23
CHAPTER 2 CONNECTING THE TEACH PENDANT Explanation of displayed items are as follows: Table 2.8 System Monitor Display Items
Item VERSION NC MODE
RB MODE
SCALE
I/O TYPE
ID VOLTAGE
BATTERY
MEM BATTERY
HOUR METER RB TYPE EN
(3)
Meaning Controller Version Controller Mode ・MANUAL ・AUTO Robot Mode ・AUTO ・CHECK ・TEACH ・KEY-IN Scale Factor ・NORM : Standard ・SHORT : Short stroke ・LONG : Long stroke ・SUPER : Super long stroke I/O type ・REMOTE : Hirata remote I/O ( With ID No.) ・CC-Link : CC-Link ・Dev-Net : DeviceNet ・Option1 : Option 1 ・Option2 : Option 2 ID number for each axis +5V voltage of CPU board ・OK : Normal ・NG : Abnormal (Lower than 4.3V) Voltage of CPU board battery ・OK : Normal ・NG : Abnormal (Lower than 3.3V) Voltage of memory card battery ・OK : Normal ・NG : Abnormal (Lower than 2.4V) ・** : Not equipped Elapsed time after system set up Robot type The rest of encoder battery ・OK : Normal ・NG : Abnormal ・** : No axis mot FUNC + 3 [mot] keys(motion) HIGH
Selects the aging mode. This function is used before shipping at the factory. Refer to 2.10, “Aging.”
(4)
s.ed FUNC HIGH + 4 [s.ed] keys(sequence edit)
Edits the position data collectively. Refer to 8.5, “Editing Position Data in Blocks.”
2-16
Page 24
CHAPTER 2 CONNECTING THE TEACH PENDANT
(5)
p.ed FUNC HIGH + 5 [p.ed] keys(position edit)
Edits the position data collectively. Same function as [s.ed] previously referred. Refer to 8.5, “Editing Position Data in Blocks.”
(6)
home FUNC + 6 [home] keys(home mode) HIGH
Returns the display to the home mode from all other modes. (7)
s.g FUNC HIGH + 7 [s.g] keys(System Generation)
Edits the System Generation data. Refer to Chapter 18, “Details of System Generation.”
(8)
s.p FUNC + 8 [s.p] keys(System Parameter) HIGH
Edits System Parameter data. Refer to Chapter 19, “Details of System Parameters.”
(9)
key FUNC HIGH + 9 [key] keys(KEY-IN)
Changes the mode to KEY-IN when the mode is ON-LINE. Refer to Chapter 4, “KEY-IN Mode.”
(10)
io FUNC + SEL [io] keys(input/output) HIGH
Changes the display to I/O monitor. Refer to 9.1, “DI/DO Monitor.”
(11)
m.c FUNC + M.OUT [m.c]keys(memory card) HIGH
Changes the display to memory card mode. Refer to Chapter 13, ”Memory Card.”
(12)
k.in FUNC HIGH + M [k.in] keys(key input macro)
Starts and ends the key input macro that stores keyed in.
(13)
k.out FUNC + S [k.out] keys(key output macro) HIGH
Executes the stored key-in data input with the key-in macro. An example of the key input/output macro is described in following page.
2-17
Page 25
CHAPTER 2 CONNECTING THE TEACH PENDANT
Set the Z-Axis data to “10.”
EXAMPLE
① ② ③
FUNC HIGH k.in
+ M : Starts key input cal
↑Z
→ 1 ,
FUNC HIGH k.in M
+
* 0
→
ENTER
→
ENTER
: sets “10” to the Z-Axis data
: Ends key input
④ Set the address where the Z-Axis data of “10” is to be entered. ⑤
FUNC HIGH k.out
+ S : Executes key macro. The Z-Axis data of the set address should be “10.”
This function is useful for repeating key operation.
(14)
local FUNC + F [local] keys(local) HIGH
Moves the cursor to the displayed coordinate’s data. Refer to 2.7, “LCD (Liquid Crystal Display).”
(15)
FUNC seq HIGH + A [seq]keys(sequence)
Sets the mode to enter sequence data or input the particular data.
2.10
Aging The robot should be operated continuously in order to test the robot motion. The speed in aging mode is set by the System Parameter i, 「MOTION」→ 「AXIS SPEED」→「AXIS A,B(X,Y),W」→「AXIS Z」. (1)
Execute A-CAL first if the A-CAL has not been completed.
(2)
Set the position data to be entered and put the END point (Mdata=??) at the end of the position. Refer to 8.1, “Entering END Point (M-Data=??)” to set the END point.
(3)
Press the
(4)
Run the robot in CHECK mode to confirm the motion speed because the speed in aging mode is same as in AUTO mode. Then set the position from the first address to the end of the address with the END point in order.
(5)
Press the
FUNC HIGH
FUNC HIGH
+
F3 keys to change to CHECK mode.
mot
+ 3 keys. The displays shows;
Motion Set Motion = [NORMAL ] Motion Address 0000 Aging Count 0000
Fig.2.9 Aging Mode Display i
: Press the
FUNC s.p HIGH + 8 keys to change.
2-18
Page 26
CHAPTER 2 CONNECTING THE TEACH PENDANT (6)
Input the data. Press the io SEL key to select the 「Motion」 data.
Input the all data following the method given below; ① Input the data. ENTER
② Press the key to enter the input data. The message line displays the message “ENTER OK?” and a beep sounds. ③ Press the
ENTER key again to confirm the input data.
The meaning of each of the items on the display is: •
「Motion」 Selects the motion in three types. ・NORMAL ・AGING ・ADJUST (Currently not used.)
•
「Motion Address」 Sets the first address of the position data which you set in step (2) previously. 「Aging Count」 Inputs the times to repeat the aging motion. Set to “0” not to specify the repeat times.
•
(7)
FUNC
F4 keys to change to AUTO mode and the message Press the HIGH + line will display ”AGING.”
The NC MODE (controller mode) is AUTO, the aging mode cannot be selected and the message ”NC Mode Error!!” is displayed. (8)
Before aging the robot, confirm the safety around the operation area and be ready to push the E.S. button. Then press the start aging.
START key to
・ Push the E.S. button to stop the robot operation when the robot works with noise or vibration. ・ Aging speed can be set to the maximum speed by the System Generation. (9)
The robot starts aging.
(10) Change the mode from AUTO to any other to stop the aging.
2-19
Page 27
CHAPTER 3 A-CAL(AUTOMATIC CALIBRATION)
CHAPTER 3 3.1
A-CAL(Automatic Calibration)
Basic Operation It is necessary to perform A-CAL (Automatic calibration) and light the 『ACAL』 LED on the Teach Pendant before the robot operation. The position of each axis is detected by counting the encoder pulse generated from the encoder which is connected each axis. The encoder and counter do not count the encoder pulse unless the controller has been connected to the power supply. The robot must know the current position in physically and electronically. Generally, all the mechanism requires, so-called calibration, which is to match the coordinate data in the controller and physical robot position. A-CAL automatically brings about the coincidence of the two origins. Once A-CAL is done after turning ON the power, it is not necessary to repeat the A-CAL procedure as long as the 『A-CAL』 LED remains ON.
The 580 series controller uses the ABS (Absolute) encoder to detect the position, so that the A-CAL is performed only once when the robot is installed. That is, it is not necessary to perform A-CAL again after the first A-CAL. If the driver error “U” has occurred, set 「A-CAL CHEK」 in System Generation menu to ”0” and perform A-CAL again to escape from this error. Refer to 3.2, “A-CAL Parameters” for details.
3-1
Page 28
CHAPTER 3 A-CAL(AUTOMATIC CALIBRATION)
3.2
A-CAL Parameters Followings are the data referred when the A-CAL is performed. Refer to Chapter 18, “Details of System Generation” and Chapter 19, “Details of System Parameters” for details. Table 3.1 A-CAL Operation Data Item
System Generation i → 「MAINTE」→ 「MAINTENANCE DATA」→ 「A-CAL CHECK」
System Generation→ 「ORIGIN」→ 「AXIS DIRECTION」→ 「A-CAL SEQ」
System Parameter ii → 「RESPONSE」→ 「RESPONSE」→ 「A-CAL SPEED」 i ii
: Press the
FUNC s.g HIGH + 7 keys.
: Press the
FUNC s.p HIGH + 8 keys.
Meaning Determine the A-CAL algorithm. 0: Set current position as origin position. 1: A-CAL the robot, but alert an operator with “A-CAL WARNING” when the origin is out of range. 2: Ignores the error when the origin is out of range. 16: Define the origin when the origin (ORG) sensor turns ON. 32: Define the origin when the origin (ORG) sensor and Z signal of motor turns ON. Sets the axis order to be performed A-CAL; 0 0 0 0 0 0 ↓ ↓ ↓ ↓ ↓ ↓ A B Z W R C Define the same number for the axis to be performed A-CAL simultaneously. Sets A-CAL speed by percentage of the maximum speed.
3-2
Data
You can set multiple conditions to A-CAL by adding the codes. <Example> “17” (=16+1) Sets the origin when the ORG sensor turns ON and warn the error when the origin is out of range and keep the operation. Combination of 1 and 2, and 16 and 32 is invalid.
Setting range: ”000000”- “666666” ・000000: No order is set (A-CAL is in standard order). ・666666: A-CAL is all axes simultaneously. Standard order: 221222 Performs A-CAL for Z-Axis first, and rest of axes A-CAL. Setting range: “1”-“999” (0.1%99.9%) Standard setting: 50 (50%)
Page 29
CHAPTER 3 A-CAL(AUTOMATIC CALIBRATION)
3.3
A-CAL Procedure A-CAL
Press the key to perform A-CAL in TEACH and CHECK mode. In the automatic operation, A-CAL is performed by the commands, such as SELECT signal in AUTO mode and A-CAL command in ON-LINE mode, from external devices. Refer to 2.4, “Mode Select Operation,” about the robot modes. The following is the manual A-CAL procedure to be performed with the Teach Pendant. (1)
Set the Teach Pendant to TEACH or CHECK mode. A-CAL can be performed in both modes by the same procedure.
(2)
Make sure not to release the Deadman switch during the following operation. Releasing the Deadman switch causes the system to go into Emergency Stop status.
(3)
Set the position data display by pulse. FUNC HIGH
+ F keys.
② Press the key 9 key.
READ
③ Press the (4)
local
① Press the
Press the
FUNC HIGH
+ key
A-CAL keys, then the following screen will appear as +R/R
+C
↑Z
+W below. Select the axis to A-CAL by the +X , +Y , , keys. Selected axes indicate “ON” at “a” part and will execute A-CAL. Normally, select all axes “ON” when performing A-CAL unless otherwise necessary. “a” (A-CAL option selection) A-CAL the axis : ON Skip A-CAL : OFF
A-CAL SET X ON ON Y Z ON ON W Push A-CAL
MODE ON O N ON O N Key!!
“b” (A-CAL status) A-CAL completed : ON Incompleted : OFF
Fig.3.1 A-CAL Axis Selection(4 Axes Robot)
• Press the
+R/R +X key to select X-Axis.
• Press the
+C +Y key to select Y-Axis.
• Press the ↑Z key to select Z-Axis. • Press the
+W key to select W-Axis. +R/R
• Press the SHIFT + +X keys to select R-Axis. +C
• Press the SHIFT + +Y keys to select C-Axis.
3-3
Page 30
CHAPTER 3 A-CAL(AUTOMATIC CALIBRATION)
A-CAL
A-CAL
(5)
Keep pressing the key until the A-CAL completes.
(6)
When A-CAL is completed successfully, “A-CAL COMPLETED”will be appeared on screen and a buzzer will sound. If A-CAL could not be completed for some reason, “A-CAL INCOMPLETE”will be appeared and a buzzer will sound. Repeat from step (2) in the case of A-CAL incomplete. Once A-CAL is done, the 『A-CAL』 LED lights.
(7)
Verify the A-CAL results. Take note of the current encoder pulse count on the screen. To display the pulse count; local
① Press the
FUNC HIGH
+ F keys.
② Press the key 9 key.
③ Press the
READ key.
(8)
Turn OFF the power.
(9)
Turn ON the power again.
(10) Compare the current encoder pulse and recorded pulse at step (7). If the pulse difference is less than 100 pulse, A-CAL is done successfully. If the difference is exceeding 100 pulse, go back to step (2) above.
A-CAL
Releasing the key before A-CAL complete, the robot stops the A-CAL operation and “A-CAL INCOMPLETE” is displayed and a buzzer will sound. Perform A-CAL operation again from step (2) above.
3.4
A-CAL Related Error A-CAL is the most basic operation to confirm robot functionality. By performing A-CAL, it is confirmed whether or not the motor, encoder and sensor of each axis works and are controlled correctly. While A-CAL is being performed, error detection is executed at each stage of A-CAL. The error codes are shown below. Table 3.2 A-CAL Error Code Message * 0 Not Find * 1 Not Off * 2 Other On * 4 Lower * 5 Upper * 7 Error
Meaning ORIGIN sensor did not respond. ORIGIN sensor does not back OFF. OVERRUN sensor response during A-CAL. A-CAL completed below the safety margin. A-CAL complete above the safety margin Misc. unknown error.
“*” mark indicates the axis that caused the error. A=A(X)-Axis, B=B(Y)-Axis Z=Z-Axis, W=W-Axis, R=R-Axis, C=C-Axis.
3-4