Page 31

CHAPTER 3 A-CAL(AUTOMATIC CALIBRATION)

User Action for “*0 Not Find”

3.4.1

This error means missing ORIGIN sensor signal input. Take following steps to resolve the problem. Possibly, the sensor did not react or mechanically the robot did not move onto the sensor. (1)

Retry A-CAL and monitor the robot motion. Verify there is no mechanical jam, slip or broken timing belt which causes mechanical failure. If you find a problem, take the necessary actions to correct it.

(2)

Move the robot to verify the sensor turns ON. ① Go to RO-TEACH mode. ② Press the minus (-) axis key to move the robot until the ORIGIN sensor reacts. •

-R/L -X key

: X (A)-Axis moves toward ORIGIN sensor direction.

•

-C -Y key

: Y(B)-Axis moves toward ORIGIN sensor direction.

•

↑Z key

: Z-Axis moves toward ORIGIN sensor direction.

•

-W key

: W-Axis moves toward ORIGIN sensor direction.

•

SHIFT

+ -X keys : R-Axis moves toward ORIGIN sensor direction.

•

SHIFT

+ -Y keys : C-Axis moves toward ORIGIN sensor direction.

-R/L

-C

③ Move the robot to confirm the ORIGIN sensor turns ON and the message “OVERRUN******” should be displayed on the Teach Pendant. The “******” part shows the sensor status of each axis by number in the order of “XYZWRC.” Table 3.3 Description for the “******” Part Number 0 1 2 3

Meaning The sensor is not ON. The ORIGIN sensor is ON. The OVERRUN sensor is ON. The ORIGIN and limit sensors are ON.

④ Confirm the “1” is displayed on the “******” part. For example, when the ORIGIN sensor of X-Axis is ON, the display shows ”100000.” Check the sensor and replace it if necessary. If you get a message other than 1, the ORIGIN/OVERRUN sensor is defective or the sensor is not properly connected.

3-5

Page 32

CHAPTER 3 A-CAL(AUTOMATIC CALIBRATION)

3.4.2

User Action for “*1 Not Off” This message indicates that the sensor did not turn OFF after the axis left from the sensing range. When you get this message, you should see the OVERRUN error when you turn the power ON. (1) Retry A-CAL and monitor the robot motion. Verify there is no mechanical jam, slip or broken timing belt which causes mechanical failure. If you find a problem, take necessary actions to correct it. (2) Move the robot to verify the sensor turns OFF. ① Go to RO-TEACH mode. ② Since the ORIGIN sensor turns ON, the message “OVERRUN ******” should be displayed on the Teach Pendant. Confirm the “1” is displayed on the “******” part which shows the sensor status of each axis by number in the order of “XYZWRC.” For example, when the ORIGIN sensor of X-Axis is ON, the display shows ”100000.” ③ Press the plus (+) axis key move the robot until the ORIGIN sensor reacts. •

+R/R +X key

: X (A)-Axis moves toward OVERRUN sensor direction.

•

+C +Y key

: Y(B)-Axis moves toward OVERRUN sensor direction.

•

↓Z key

: Z-Axis moves toward OVERRUN sensor direction.

•

+W key

: W-Axis moves toward OVERRUN sensor direction.

•

SHIFT

+ +X keys : R-Axis moves toward OVERRUN sensor direction.

•

SHIFT

+ +Y keys : C-Axis moves toward OVERRUN sensor direction.

+R/R

+C

④ Verify the sensor turns OFF when the axis leaves the sensing area. The “OVERRUN *****” message should disappear. If the sensor still does not go OFF, replace the sensor.

3-6

Page 33

CHAPTER 3 A-CAL(AUTOMATIC CALIBRATION)

User Action for “*2 Other On”

3.4.3

This error message indicates that the OVERRUN sensor turned ON during A-CAL. This is caused by improper sensor connection. (1)

Retry A-CAL and monitor the robot motion. Verify there is no mechanical jam, slip or broken timing belt which causes mechanical failure. If you find a problem, take necessary actions to correct it.

(2)

Verify the robot motion by using the following steps. ① Go to RO-TEACH mode. ② Press each key and to verify the each axis moves correctly. •

+R/R +X key

: X (A) -Axis moves toward OVERRUN sensor direction.

•

+C +Y key

: Y(B) -Axis moves toward OVERRUN sensor direction.

•

↓Z key

: Z-Axis moves down toward OVERRUN sensor direction.

•

+W key

: W-Axis moves toward OVERRUN sensor direction.

•

SHIFT

+ +X keys : R-Axis moves toward OVERRUN sensor direction.

•

SHIFT

+ +Y keys : C-Axis moves toward OVERRUN sensor direction.

+R/R

+C

•

-R/L -X key

: X (A) -Axis moves toward ORIGIN sensor direction.

•

-C -Y key

: Y (B) -Axis moves toward ORIGIN sensor direction.

•

↑Z key

: Z-Axis moves up toward ORIGIN sensor direction.

•

-W key

: W-Axis moves toward ORIGIN sensor direction.

•

SHIFT

•

SHIFT

-R/L

+ -X keys : R-Axis moves toward ORIGIN sensor direction. -C

+ -Y keys : C-Axis moves toward ORIGIN sensor direction. ③ Verify each sensor reacts correctly. Most likely, when you see this error, the ORIGIN/OVRRUN sensor is not properly connected.

3-7

Page 34

CHAPTER 3 A-CAL(AUTOMATIC CALIBRATION)

3.4.4

User Action for “*4 Lower” Sensor tab is adjusted lower than safety margin. To correct the position drift, it is recommended to adjust the sensor tab position. This error indicates that A-CAL is completed when the encoder pulse count is less than 2,048. The position of the sensor and sensor tab should be set so that the ORIGIN sensor turns ON between 2,048~6,144 pulses.

3.4.5

User Action for “*5 Upper” Sensor tab is adjusted lower than safety margin. To correct the position drift, it is recommended to adjust the sensor tab position. This error indicates that A-CAL is completed when the encoder pulse count is greater than 6,144. The position of the sensor and sensor tab should be set so that the ORIGIN sensor turns ON between 2,048~6,144 pulses.

3.4.6

User Action for “OVERRUN ******” The OVERRUN sensor maybe disconnected. Check the sensor connection. However the “OVERRUN ******” error during the procedure above mentioned to recover from A-CAL error is a normal message.

3-8

Page 35

CHAPTER 4 KEY-IN MODE

CHAPTER 4 4.1

KEY-IN Mode

General KEY-IN mode enables you to enter the position data with the numeric keys manually. Set the controller mode to MANUAL and press the

FUNC HIGH

+

F1 keys to enter

KEY-IN mode. Also, it is able to enter KEY-IN mode by pressing the

FUNC HIGH key

+ 9 keys in AUTO mode. In KEY-IN mode, the position data, which is stored in memory, is displayed and “KEY-IN” will appear on the message line. Enter each data with the numeric keys at the place where the cursor “■” is located. 0000 M01 F90 S00 R 0 X 0123.45 Y-0123.45 Z 0123.45 W 0123.45 KEY-IN RB1 [WORLD]

Fig.4.1 Display in KEY-IN Mode(Robot 1 with 4 Axes) In KEY-IN mode, all axes are not in HOLD condition; however, only the motor equipped with a brake is held.

4.2

Basic Operation The following is basic operation to enter the position data. (1)

Address seq up k.in up local up

Press the A key, or the DOWN key to position the cursor to the address data. Set the data with the numeric keys. (2)

M-data Press the M key, or the DOWN key to position the cursor to the Mdata. Set the data with the numeric keys.

(3)

F-code Press the F key, or the DOWN key to position the cursor to the Fcode. Set the data with the numeric keys.

4-1

Page 36

CHAPTER 4 KEY-IN MODE (4)

S-code k.out up

Press the S key, or the DOWN key to position the cursor to the Scode. Set the data with the numeric keys. (5)

Arm position Press the key or the

(6)

SHIFT -R/L -X key to light up the 『SHIFT』 LED. Press the

+R/R +X key to set the arm position, “R” or “L.”

Coordinates system display FUNC local up

Press the HIGH + F keys or the DOWN key to move the cursor to the position where the data is to be entered by the numeric keys. (7)

Position data Move the cursor to the position where the axis data is to be entered. ① The robot with 4 axes (X,Y,Z,W) •

X-Axis : Press the up DOWN

•

•

•

+C +Y key and the

↑Z key and the

+W key and the key to move the cursor.

② The robot with 6 axes (X,Y,Z,W,R,C) Press the up DOWN key, or press the

-C -Y key, or press the

↓Z key, or press the

-W key, or press the key to move the cursor.

W-Axis : Press the up DOWN

-R/L -X key to move the cursor.

Z-Axis : Press the up DOWN key and the key to move the cursor.

Y-Axis : Press the up DOWN

+R/R +X key to move the cursor.

4-2

Page 37

CHAPTER 4 KEY-IN MODE

4.3

Basic Operation Example The following is an example to enter new position data into address 50, M=10, F=99, R/L=L, X=500.05, Y=-80, Z=20.1, W=100 FUNC

F1

(1)

Press the HIGH +

(2)

The display shown in Fig.4.1, Display in KEY-IN Mode (Robot 1 with 4 Axes) will appear. However the displayed data indicates the stored data. Enter new data as follows.

keys to set the Teach Pendant to KEY-IN mode.

① Set the Address to “50.” Press the seq A p.ed 5 key and enter

* 0

,

.

0050 M01 F90 S00 R 0 ② Set the M-data to “10.” Press k.in M key and enter cal 1

* 0

,

.

0050 M10 F90 S00 R 0 ③ Set the F-data to “99.” Press the local F key and enter key 9 twice.

0050 M10 F99 S00 R 0 ④ Set the arm position to, “R” or “L.” Press the key.

SHIFT key and 『SHIFT』 LED is lit, and press the

-R/L -X

0050 M10 F99 S00 L 0 ⑤ Set the X data to “500.05.” Press the or the

-R/L -X

SHIFT key and 『SHIFT』 LED is lit. Press the key and enter p.ed 5

→

* 0

→

* 0

→

/ .

→

* 0

→

+R/R +X p.ed 5 key

.

X 0500.05 Y 0123.45 ⑥ Set the Y data to “-80.” Press the

+C +Y key or the

-C -Y key and enter

+ - s.p

*

*

/

→ 8 → 0 .

X 0050.05 Y-0080.00 ⑦ Set the Z data to “20.1.” Press the cal 1

↑Z key or the

↓Z key and enter task 2

→ 0 → .→

. Z 0020.10 W 0123.45

⑧ Set the W data to “100.” Press the

+W key or the

-W key and enter cal 1

Z 0020.10 W 0100.00

4-3

*

*

→ 0 → 0 .

Page 38

CHAPTER 4 KEY-IN MODE

(3)

The following display appears using above procedure. 0050 M10 F99 S00 L 0 X 0500.05 Y-0080.00 Z 0020.10 W 0100.00 KEY-IN RB1 [WORLD]

Fig.4.2 Data Setting Display (Robot 1 with 4 Axes)

ENTER

When the coordinates system has been changed before pressing the key to enter the data (ADD, R, M, F, X, Y, Z, W, R, C), all data changes except the coordinates system displayed will be canceled. Be sure to enter the data before changing the coordinates system (Coordinates System is the System Parameters selected on「DISPLAY OFFSET 1-3」i.)

ENTER

(4)

Press the key to enter the input data. “ENTER OK ?” will appear on the message line and a buzzer will sound.

(5)

Press the

(6)

After the confirmation, the next address data will appear on the display (For this example, address “51”). There are two ways to check the data at address “50”. The Fig.4.2, Data Setting Display (Robot 1 with 4 Axes) will appear using either following procedures.

(7)

ENTER key again to confirm the input data.

z Press the SHIFT key to light up the 『SHIFT』 LED, then press the dec INC key to go back to previous address which data of address “50” is displayed.

z Press the seq A key to move the cursor to the position where the address data is to be entered. Press the READ p.ed 5

*

→ 0 keys. Press the key and Fig.4.2, Data Setting Display (Robot 1 with 4 Axes) will appear.

i

: System Parameter, 「OFFSET」→「DISPLAY OFFSET1-3」→「DISP.**」

4-4

Page 39

CHAPTER 4 KEY-IN MODE

4.4

Data Correction (1)

To correct wrong data; Move the cursor to the position where the correct data is to be input and entered.

(2)

To cancel all data before entering; READ key and the display shows the data stored in the Press the current address. (3)

When you cancel the entry of all data and start from address “0000”; Press the

(4)

spd CAN key

When you cancel the entry of data; After “ENTER OK ?” appears on the display, press any key except the

(5)

ENTER key.

When an error message appears on the display; spd

Data cannot be entered. Press the CAN key then the error message disappears and the stored data is displayed. After confirming the error (Refer to Chapter 23, “Message”), enter the correct data.

4-5

Page 40

CHAPTER 5 TEACH MODE

CHAPTER 5 5.1

TEACH Mode

General This mode enables you to manipulate the robot and perform teaching by hand or with the axis key i. The axis moves at high speed by pressing each axis key with the

FUNC HIGH key.

If you press the opposite direction keys (e.g., the axis does not move.

+R/R +X

,

-R/L -X

) at the same time,

While operating the robot in TEACH mode, hold the Deadman switch. If you release the Deadman switch, the Emergency Stop function turns ON. FUNC

F2

Set the controller mode to MANUAL and press the HIGH + keys to change TEACH mode. There are two modes for TEACH operation, LITEACH and RO-TEACH. The LI-TEACH is to manipulate the A,B (X,Y)Axes linearly along the X-Y coordinates set by the system data. The ROTEACH is to manipulate each axis independently. When the mode is changed to TEACH, either mode of LI-TEACH or RO-TEACH will be designated by the coordinate system displayed on the Teach Pendant. Refer to 2.4, “Mode Select Operation” for details.

5.2 5.2.1

Basic Operation Operation with X-Y Coordinates in LI-TEACH Mode. In LI-TEACH mode, the X (A) and Y (B)-Axes are controlled simultaneously and are linearly operated along the X-Y coordinates set at DISPLAY OFFSET ii. The X (A) and Y (B)-Axes moves in parallel with the X coordinate with the

+R/R +X or the

+C +Y

-R/L -X key and in parallel with the Y

-C -Y coordinate with the or the key. In linear operation, the W-Axis moves independently and keeps its orientation to the X-Y coordinates.

A-CAL

Unless the 『A-CAL』 LED is lit, you cannot operate the robot in LI-TEACH mode. “A-CAL INCOMPLETE” will appear on the display. Refer to Chapter 3, “ A-CAL (Automatic Calibration)” to perform A-CAL.

+R/R

-R/L

-R/L i

-C

↑Z

↓Z

+W

: The axis is specified by pressing the +X , -X , -X , -Y , , , ,or the to Fig.2.1, “Naming and Function of the Teach Pendant.” ii : Specified by 「OFFSET」→「DISPLAY OFFSET1-3」→「DISP.**」 in System Parameter menu.

5-1

-W key. Refer