The text of a manual · part 12 of 12
Visual KV Series User's Manual 2: Support Software, pages 101 to 105
Pages 101 to 105 of 105
The original document is the PDF (910 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Keyence KV-16R
Page 101
Chapter 2 Editor ■ Ladder diagram (details)
2 Example of printout LADDER
Name : SAMP01.LDR (KV10)
0001
**
Date : 1997/09/06
**
0000
$00024 T 000
T000
$00020 T 001
T001
$00054 T 002
0002
0003
0004 0000
Page (1/1)
L0002 (A) L0006 (A)
L0005 (%)
L0006 (A) L0007 (A)
L0008 (%)
L0007 (A)
T000
0005
Item
Setting contents (input range)
Initial value
Print Start Line No.
Line number from which printout is started
1
Print Finish Line No.
Line number at which printout is ended
Last line on edit screen
No. of Lines in Page
Number of lines printed on one page (5 to 50)
20
Print Comment
Comment 1, Comment 2, Comment 3, or No
No
Print Device
Device Name or Label Name
Device Name
Divide Block
Consider (divided) or Ignore (not divided)
Consider
■ Mnemonic list (details)
Example of printout Name : TRST02 LDR (KV01)
0000 0001 0002 0003 0004 0005 0006 0007 0008 0009 00010 00011 00012 • 00013
2-78
** LD MPS CTC CON CTC CON CTH MPP CTC CON CTC CON CTH ** LD
LIST
Date : 1997/08/22
Page (1/3)
** 2002 1
#020
0
#255
0
2101
2
#65535
3
#65535
1
0500
** 2008
Item
Setting contents (input range)
Initial value
Print Start Step
Step number from which printout is started
0
Print Finish Step
Step number at which printout is ended
65534
No. of Lines in Page
Number of lines printed on one page (30 to 120)
60
Print Comment
Comment 1, Comment 2, Comment 3, or No
No
Print Device
Device Name or Label Name
Device Name
Page 102
Chapter 2 Editor ■ Labels/comments/references (details) Add the check mark to the devices to be printed out, and set the printout range. By default, all devices are selected and the entire range is specified.
12
Example of printout Label
Name : SAMP01.LDR (KV10)
< > <N0.> 0000
<Label> : L002(A)
<Comment1> SWO L0006(A)
0500
: OUTPUT 500 L006(OUT)
0501
: OUTPUT 501 L008(OUT)
0502
: OUTPUT 502 L007(OUT)
Date : 1997/09/06
<Comment2> SWITCH
Page (1/1)
<Comment2> SWITCH
Item
Input range (initial value)
Relay
Available range according to the model
Timer Counter High-Speed Counter
–
Comparator
–
Data Memory
Available range according to the model
Temporary Memory
–
Item
Setting contents (input range)
Initial value
No. of Lines in Page
Number of lines printed on one page (30 to 120)
70
Print References
Yes or No
No
2-79
Page 103
Chapter 2 Editor ■ Device use status Add a check mark to the devices to be printed out, and set the printout range. By default, all devices are selected to be printed out.
2
Example of printout (relay) Name : SAMP01.LDR (KV10)
[
Date : 1997/09/11
Page (1/5)
] 0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF
0000–– 0415: X 0500–– 0915: XXX 1000–– 1415: 1500–– 1915: 2000–– 2415: 2500–– 0915:
2-80
Page 104
Chapter 2 Editor
2.13.2 Preview display File (F) ➔ Print Preview (V)
To preview on the screen the contents to be printed out, perform the following procedure. 1. Select "Print Preview" from the "File" menu. The "Print Setup" dialog box is displayed. 2. Set the contents to be printed out.
12
➮ For the setup procedure, refer to page 2-79.
3. Click the [Execute] button. The actual image to be printed out is displayed. The [Print] button can be clicked on this screen to print out the contents displayed.
2-81
Page 105
Chapter 2 Editor
2.14
Changing the Display Color on the Screen In the Ladder Builder, the color layout of the screen can be changed. This section describes how to change display colors on the screen.
2.14.1 Changing display colors on the screen View ➔ Change Ladder Diagram Color
This function sets the color layout of the Ladder Builder screen. The setup procedure is described below.
2
1. Select "Change Ladder Diagram Color" from the "View" menu. The "Change Ladder Diagram Color" dialog box is displayed. The "Color" box provided on the side of each item indicates the color currently set.
Object screen
2. Select the item whose color is to be changed in the "Section to be Specified" text box, and click the button of "Color". The "Section to be Specified" text box can be set by clicking the desired position in the diagram displayed on the object screen. The "Color Setup" dialog box is displayed. Select the desired color, and click the [OK] button. You can create an intermediate color by clicking the [Create Color] button. To determine the intermediate color created, click the [Add Color] button.
Sets the color tint.
Sets the brightness.
3. When changes are complete, click the [OK] button. Click the [OK] button to confirm the setting. Click the [Cancel] button to cancel the setting. To return the screen colors to the default setting, click the [Back to Initial Setting] button. Note: When the number of display colors on the screen is set to 256 or less, some colors may not be displayed correctly.
2-82