Page 101

Chapter 2 Editor ■ Ladder diagram (details)

2 Example of printout LADDER

Name : SAMP01.LDR (KV10)

0001

**

Date : 1997/09/06

**

0000

$00024 T 000

T000

$00020 T 001

T001

$00054 T 002

0002

0003

0004 0000

Page (1/1)

L0002 (A) L0006 (A)

L0005 (%)

L0006 (A) L0007 (A)

L0008 (%)

L0007 (A)

T000

0005

Item

Setting contents (input range)

Initial value

Print Start Line No.

Line number from which printout is started

1

Print Finish Line No.

Line number at which printout is ended

Last line on edit screen

No. of Lines in Page

Number of lines printed on one page (5 to 50)

20

Print Comment

Comment 1, Comment 2, Comment 3, or No

No

Print Device

Device Name or Label Name

Device Name

Divide Block

Consider (divided) or Ignore (not divided)

Consider

■ Mnemonic list (details)

Example of printout Name : TRST02 LDR (KV01)

0000 0001 0002 0003 0004 0005 0006 0007 0008 0009 00010 00011 00012 • 00013

2-78

** LD MPS CTC CON CTC CON CTH MPP CTC CON CTC CON CTH ** LD

LIST

Date : 1997/08/22

Page (1/3)

** 2002 1

#020

0

#255

0

2101

2

#65535

3

#65535

1

0500

** 2008

Item

Setting contents (input range)

Initial value

Print Start Step

Step number from which printout is started

0

Print Finish Step

Step number at which printout is ended

65534

No. of Lines in Page

Number of lines printed on one page (30 to 120)

60

Print Comment

Comment 1, Comment 2, Comment 3, or No

No

Print Device

Device Name or Label Name

Device Name

Page 102

Chapter 2 Editor ■ Labels/comments/references (details) Add the check mark to the devices to be printed out, and set the printout range. By default, all devices are selected and the entire range is specified.

12

Example of printout Label

Name : SAMP01.LDR (KV10)

< > <N0.> 0000

<Label> : L002(A)

<Comment1> SWO L0006(A)

0500

: OUTPUT 500 L006(OUT)

0501

: OUTPUT 501 L008(OUT)

0502

: OUTPUT 502 L007(OUT)

Date : 1997/09/06

<Comment2> SWITCH

Page (1/1)

<Comment2> SWITCH

Item

Input range (initial value)

Relay

Available range according to the model

Timer Counter High-Speed Counter

–

Comparator

–

Data Memory

Available range according to the model

Temporary Memory

–

Item

Setting contents (input range)

Initial value

No. of Lines in Page

Number of lines printed on one page (30 to 120)

70

Print References

Yes or No

No

2-79

Page 103

Chapter 2 Editor ■ Device use status Add a check mark to the devices to be printed out, and set the printout range. By default, all devices are selected to be printed out.

2

Example of printout (relay) Name : SAMP01.LDR (KV10)

[

Date : 1997/09/11

Page (1/5)

] 0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF

0000–– 0415: X 0500–– 0915: XXX 1000–– 1415: 1500–– 1915: 2000–– 2415: 2500–– 0915:

2-80

Page 104

Chapter 2 Editor

2.13.2 Preview display File (F) ➔ Print Preview (V)

To preview on the screen the contents to be printed out, perform the following procedure. 1. Select "Print Preview" from the "File" menu. The "Print Setup" dialog box is displayed. 2. Set the contents to be printed out.

12

➮ For the setup procedure, refer to page 2-79.

3. Click the [Execute] button. The actual image to be printed out is displayed. The [Print] button can be clicked on this screen to print out the contents displayed.

2-81

Page 105

Chapter 2 Editor

2.14

Changing the Display Color on the Screen In the Ladder Builder, the color layout of the screen can be changed. This section describes how to change display colors on the screen.

2.14.1 Changing display colors on the screen View ➔ Change Ladder Diagram Color

This function sets the color layout of the Ladder Builder screen. The setup procedure is described below.

2

1. Select "Change Ladder Diagram Color" from the "View" menu. The "Change Ladder Diagram Color" dialog box is displayed. The "Color" box provided on the side of each item indicates the color currently set.

Object screen

2. Select the item whose color is to be changed in the "Section to be Specified" text box, and click the button of "Color". The "Section to be Specified" text box can be set by clicking the desired position in the diagram displayed on the object screen. The "Color Setup" dialog box is displayed. Select the desired color, and click the [OK] button. You can create an intermediate color by clicking the [Create Color] button. To determine the intermediate color created, click the [Add Color] button.

Sets the color tint.

Sets the brightness.

3. When changes are complete, click the [OK] button. Click the [OK] button to confirm the setting. Click the [Cancel] button to cancel the setting. To return the screen colors to the default setting, click the [Back to Initial Setting] button. Note: When the number of display colors on the screen is set to 256 or less, some colors may not be displayed correctly.

2-82