The text of a manual · part 3 of 8
Intelligent Safety Relay Unit SL-R11 Instruction Manual: 1 Specifications
Pages 7 to 12 of 42, from Intelligent Safety Relay Unit SL-R11 Instruction Manual
The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence SL-R11
Page 7
Chapter 1 Specifications
1 Specifications Integration with the SL-C SL-C Series+ SL-R11 (Intelligent Safety Relay Unit) + SL-U2 (Dedicated power supply unit)
1
Dete ctio n zo ne
SL-PC5P (5m (16.4 ft.)) cable for transmitter (gray) * 10 m (32.81 ft.) SL-PC10P cable
SL-R11 intelligent safety relay unit
SL-PC5P (5m (16.4 ft.)) cable for receiver (black) * 10 m (32.81 ft.) SL-PC10P cable
SL-U2 dedicated power supply unit
SL-U2: The UL certified, recommended dedicated power supply unit
ENGLISH 1-1 01_SL-R11E.p65
1
14.9.8, 2:34 PM
Page 8
Chapter 1 Specifications
1-1 Part Names This chapter gives the names of the SL-R11 parts. Front view
Front view Hole for mounting screw (for M4)
1 SL-C Series connector, "T" side
TR
TR
Mode switches
SL-C Series connector, "R" side Mode switch cover fastener
Relay circuit board replacement screw
POWER RESTART FSD-ON
TEST
FSD-OFF
MPCE
POWER RESTART FSD-ON
TEST
FSD-OFF
MPCE
INTERLOCK E-STOP1
INTERLOCK E-STOP1
LOCKOUT E-STOP2
LOCKOUT E-STOP2
Terminal replacement screws
See Instruction Manual.
See Instruction Manual.
Relay output terminal block
Signal input terminal block
CAUTION
CAUTION
Electric shock
Electric shock
Hole for mounting screw (for M4)
Side
Bottom
SL-R12EX connector *Covered by tape at time of shipment.
DIN rail mating area SL-U2, SL-R12EX mounting holes
Din rail lock pin
SL-U2 connector *Covered by tape at time of shipment.
English ENGLISH
Rear Connector for the light interference prevention connection *Covered by tape at time of shipment.
1-2 01_SL-R11E.p65
2
14.9.8, 2:34 PM
Page 9
Chapter 1 Specifications
1-2 Specifications Model SL-R11 Safety Light Curtain SL-C Series Power supply voltage 24V DC ±10% ripple (P-P) 10% max. Rating Current consumption 150mA max. (for SL-R11 only) Output FSD1, 2 230 V AC 4 A, 30 V DC 2 A (resistive load) 230 V AC 2 A, 30 V DC 1 A (cos ø=0.3) (inductive load) AUX 125 V AC 0.5 A, 30 V DC 2 A (resistive load) 125 V AC 0.25 A, 30 V DC 1 A (cos ø=0.3) (inductive load) Lifespan Mechanical life: 10 million times min. Electrical life: 100,000 times min. Response time FSD1, 2, AUX 24ms (including sensor response time)*2 Response time during E-STOP input 20ms Environmental Protective structure IP20 (IEC60529) (Install in control panels equal to or specifications greater than IP54) Ambient temperature -10 to +55 °C (No frost) Storage ambient temperature -10 to +60 °C (No frost) Relative humidity 35 to 85% RH (No condensation) Storage ambient humidity 35 to 95% RH Vibration 10 to 55 Hz double amplitude width 0.7 mm, 20 sweeps each for X, Y, Z directions Shock 100 m/s2 (Approx. 10G) 16ms pulse, in X, Y, Z directions 1,000 times each axis Material Polycarbonate Weight 380 g max. Approved EMC EMS UL61496-1 EMI standards *1 FCC Part 15B Class A Safety UL61496-1 (type 4 ESPE) UL61496-2 (type 4 AOPD) UL508
1
*1 Evaluated in combination with the SL-C Series *2 The OFF → ON return time is 150 ms.
1-3 External Dimensions Diagram SL-U2
SL-R11
3.5 (0.14")
3.5 (0.14")
(ø0.17") 35 (1.38") 2-ø4.2 11 (0.43") 24 (0.94")
(112 (4.41")) (102.3 (4.03")) 83.8 (3.3")
(ø0.17") 2-ø4.2
48 (1.89") 23 (0.91")
11 (0.43")
(96.6 (3.8")) 49.8 (1.96")
35.9 (1.41") 111 (4.37")
35.9 (1.41")
135 (5.31")
124 (4.89")
11 (0.43")
37 (1.46")
1-3 01_SL-R11E.p65
3
14.9.8, 2:34 PM
ENGLISH
100 (3.94")
23 (0.91") 25.8 (1.02")
Page 10
Chapter 1 Specifications
1-4 Power Supply Precautions 1-4-1 Power Units that Can Be Used as Power Supplies for SL-C Series and SL-R11
1
The power supply units that can be used as the power supply for SL-C Series and SL-R11 must completely satisfy the following requirements in order to satisfy the requirements of UL61496-1 for the SL-C Series and SL-R11. (a) Rated output voltage is 24V DC ±10%. (b) The power supply to be used shall be a dedicated power supply for the SL-C Series and/or SL-R11 and shall not be used to supply power to other devices. (c) The power supply output must satisfy the requirements for a Class 2 Circuit or Limited Voltage/Current Circuit as prescribed by UL508. (This requirement applies only when the SL-C is to be used in North America.) (d) The power supply must comply with the laws, regulations, and standards covering electrical safety, electromagnetic compatibility (EMC), etc., for the country or region in which the SL-C Series and/or SLR11 will be used. (e) The output hold time is 20 ms min.
1-4-2 Recommended Dedicated Power Supply Unit The SL-U2 is offered as the SL-C Series dedicated power supply. The SL-U2 is a power supply that completely satisfies the above requirements. <Approved standards> Standard EN60950-1 EN50178 UL60950-1 (R/C) UL508 (Listing) EN55011 Class A EN61000-6-2 FCC Part 15B Class A
Safety standard
EMC standard
SL-U2
SL-U2 OC
+
+ 24V DC
–
-
PE (GND)* CAUTION
100-240V AC ONLY
100 to 240 V AC
L
N
English ENGLISH
(*) The PE terminal is a protective conductor terminal that must be connected to a protective earthing conductor in the building installation.
1-4 01_SL-R11E.p65
4
14.9.9, 10:04 PM
Page 11
Chapter 1 Specifications <Specification> SL-U2
Model System Input power supply voltage Overvoltage category
Switching type AC 100 to 240 V ±10 % (50/60 Hz) II DC 24 V ±10 %, Class 2 240 mVp-p or less 1.8 A -10 °C to +55 °C (non-freezing) 35 % to 85 % RH (non-condensing) 2 AC 1,500 V, 1 min. (between all external terminals and case) 10 to 55 Hz, 0.7 mm (0.03") compound amplitude, 20 sweeps each in X, Y, and Z directions 100 m/s2, 1,000 iterations each in X, Y, and Z directions At least 50 MΩ (DC 500 V mega, between all external terminals and case) 135VA
Output voltage Ripple/noise Output capacity Environ- Ambient temperature ment Relative humidity Pollution degree Withstand voltage Vibration resistance Shock resistance Insulation resistance Power consumption 10 ms or less Supply voltage interruption Weight (excluding dedicated brackets) Approx. 240 g
WARNING
1
For the power supply used for the SL-C Series and SL-R11, always use a power supply that can fully satisfy the above requirements or use recommended SL-U2 power supply. Otherwise, the UL61496-1 requirements may not be satisfied and the SL-C Series and SL-R11 may not be recognized as a safety component.
ENGLISH 1-5 01_SL-R11E.p65
5
14.9.9, 10:04 PM
Page 12
Chapter 1 Specifications
MEMO
1
English ENGLISH 1-6 01_SL-R11E.p65
6
14.9.8, 2:34 PM