Manual · Keyence
Intelligent Safety Relay Unit SL-R11 Instruction Manual
Manual42 pagesPDF 1.7 MB
Instruction manual for the Keyence SL-R11 intelligent safety relay unit used with the SL-C series safety light curtains.
Covers · 1 model
The models it covers
Summary
What is in it
Instruction manual for the Keyence SL-R11 Intelligent Safety Relay Unit, which works with the SL-C series safety light curtain and the SL-U2 power supply. It covers safety precautions, specifications and dimensions, power supply precautions, functions (start and restart interlock, E-STOP input, MPCE monitor, main/sub setting, test input, FSD and AUX outputs, mode switches), DIN rail and wall mounting, wiring, a pre-use checklist, maintenance and troubleshooting.
Its parts
- Safety Precautions
- 1 Specifications
- 2 Functions
- 3 Mounting and Installation
- 4 Wiring
- 5 Checklist
- 6 Maintenance
- 7 Troubleshooting
- 8 Revision History
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Instruction manual for the SL-R11 Intelligent Safety Relay Unit, the dedicated control unit for the SL-C Series safety light curtain. It gives the specifications, explains the interlock, E-STOP, MPCE monitor and test functions and the mode switches, and covers mounting, wiring and troubleshooting.
- Type
- Safety relay control unit for the SL-C Series safety light curtain p. 21
- Power supply
- 24V DC ±10%, ripple (P-P) 10% max. p. 9
- Current consumption
- 150mA max. (SL-R11 only) p. 9
- FSD1, 2 outputs
- 230 V AC 4 A, 30 V DC 2 A resistive; 230 V AC 2 A, 30 V DC 1 A inductive (cos ø=0.3) p. 9
- AUX output
- 125 V AC 0.5 A, 30 V DC 2 A resistive; 125 V AC 0.25 A, 30 V DC 1 A inductive (cos ø=0.3) p. 9
- Response time
- FSD1, 2, AUX: 24ms including sensor response time; E-STOP input: 20ms p. 9
- Relay life
- Mechanical 10 million times min.; electrical 100,000 times min. p. 9
- Operating temperature
- -10 to +55 °C (no frost) p. 9
- Enclosure
- IP20; install in a control panel of IP54 or better p. 9
- Weight
- 380 g max. p. 9
- SL-C cables
- SL-PC5P/SL-PC10P and SL-CC10PT/SL-CC10PR only; 30m (98.43 ft.) max. each p. 25
- Dedicated power supply
- SL-U2 recommended dedicated power supply unit p. 10
- Output terminal wire
- AWG # 22 to 12, stranded copper only, min. 60 °C; torque 0.5 N•m p. 26
- Mounting
- DIN rail or wall mounting with screws p. 2, 21
What this manual walks you through
- Using the start interlock, restart interlock and E-STOP input p. 13
- Monitoring the machine primary control element (MPCE) p. 14
- Setting main and sub units for a light interference prevention connection p. 15
- Reading the status and input indicators p. 16
- Setting the mode switches p. 17, 18
- Mounting the unit on a DIN rail p. 21
- Connecting the SL-C transmitter and receiver cables p. 25
- Wiring and replacing the relay output terminal block p. 25, 26
- Troubleshooting errors from the SL-C bar LED display p. 38, 39
Good to know
- FSD1 and FSD2 must both be used, wired as an AND circuit. p. 15
- The AUX relay output is for monitoring only and cannot be used to build a safety system. p. 15
- The TEST input cannot serve as an emergency stop input. p. 15
- SL-C connection cables longer than 30m each may cause unstable operation. p. 25
- The manual states the SL-C and SL-R11 have UL Canada-U.S.-Listing to UL61496-1 and UL61496-2. p. 6
Questions this manual answers
What power supply does the SL-R11 need?
24V DC ±10% with ripple of 10% max.; the unit alone draws 150mA max. The manual offers the SL-U2 as the dedicated power supply. p. 9, 10
Which cables connect the SL-R11 to an SL-C light curtain?
Only the SL-PC5P/SL-PC10P and SL-CC10PT/SL-CC10PR cable combinations, each up to 30m (98.43 ft.). p. 25
How do I enable the start interlock on the SL-R11?
With the power off, turn on both mode switches of the pair, 2 and 6, before supplying power. p. 18
How do I clear an SL-R11 lockout?
When the lockout indicator is flashing, fix the cause shown on the SL-C bar LED display, then turn the power off and on again. p. 38
What wire fits the SL-R11 relay output terminals?
AWG # 22 to 12, stranded copper only, rated min. 60 °C, stripped 7mm and tightened to 0.5 N•m. p. 26
Contents
Chapters and sections
Each line opens the PDF at its page.
- Safety Precautions4
- 1 Specifications7
- 2 Functions13
- 2-1 Start Interlock13
- 2-2 Restart Interlock13
- 2-3 E-STOP Input13
- 2-4 MPCE (Machine Primary Control Element) Monitor14
- 2-5 Main/Sub Setting15
- 2-6 TEST Input15
- 2-7 FSD Output15
- 2-8 AUX Output15
- 2-9 Relay Replacement and Terminal Block Installation Removal Function16
- 2-10 Status Indicators16
- 2-11 Mode Switch Settings17
- 2-12 I/O Circuit19
- 3 Mounting and Installation21
- 4 Wiring25
- 5 Checklist35
- 6 Maintenance36
The whole text · 8 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file