Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 7 of 8

Intelligent Safety Relay Unit SL-R11 Instruction Manual, pages 35 to 37

Pages 35 to 37 of 42: 5 Checklist; 6 Maintenance

The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence SL-R11

Page 35

Chapter 5 Checklist

5 Checklist 5-1 List of Pre-use Check Items After the SL-C Series and SL-R11 are installed, the responsible personnel shall use the following checklist to check operation. The following checklist contains the minimum necessary items for using the SL-R11. The required check items will differ depending on the laws and regulations of the country or region of the machine in which the SL-R11 is being used, so KEYENCE corporation strongly recommends that the responsible personnel add any required check items to this check list. This check list is only to be used for the SL-R11, so refer to the SL-C Series Instruction Manual to create a checklist based on using the SL-R11 in combination with SL-C Series.

5-1-1 First, Check the SL-R11 Installation Conditions ❏ The SL-R11 is installed in an appropriate enclosure with at least an IP54 rating (in a control box, etc.). ❏ The machine to be controlled by the SL-R11 must be capable of receiving the output signal from the SL-R11 FSD and of emergency stops. ❏ For the method to reset the interlock (switches, etc.), the SL-R11 must be installed in a position where the entire hazardous zone or source of hazard can be checked and where it cannot be operated from within the hazardous zone.

5-1-2 Check the Wiring Before Turning on the Power ❏ For the SL-R11 power supply, only a dedicated power supply should be used to supply power to the

5

SL-C Series light curtain system, including the SL-R11. No other device can be supplied from the same power supply. ❏ To supply power to the SL-R11, KEYENCE Corporation strongly recommends that the SL-U2 be used, but a different DC24V power supply that satisfies the power supply conditions specified in this instruction manual may be used. (Be sure to refer to the power supply items.) ❏ The transmitter cable (gray) is correctly connected to the transmitter cable connector, and the receiver cable (black) is correctly connected to the receiver cable connector. ❏ When connecting 2 or more SL-R11s using the light interference prevention connections, correctly use the light interference prevention cable prescribed in this instruction manual. ❏ The FSD is connected to the machine's control circuit, and the wiring is such that the machine can be correctly stopped by the FSD output. ❏ When the E-STOP function is used, the wiring is such that the machine can be correctly stopped by the E-STOP input. ❏ When 2 or more emergency stop switches are connected to the E-STOP terminal, they are connected in series.

5-1-3 Check Using an Operation Test While Machine is Stopped ❏ When the start interlock is enabled, the SL-C Series and SL-R11 go to the start interlock state and

5-1

ENGLISH the machine stops. ❏ When the restart interlock is enabled and the SL-C is in the blocked beam state, the SL-C Series and SL-R11 go to the interlock state and the machine stops.

Page 36

Chapter 6 Maintenance

6 Maintenance 6-1 Regular Inspections 6-1-1 Output Relay Inspection Refer to the SL-C instruction manual and put the SL-C Series in the blocked beam state, or use the test input and turn this unit's FSD output off. At this time, confirm that both FSD outputs are off, and that the MPCE (machine primary control element) which is connected to the FSD is off. If the relay is fused or malfunctioning, ➮ See 6-2 “Relay Circuit Board Replacement” (➮ page 6-1) and service it.

6-1-2 E-STOP Function Check 1. Check to make sure there are no errors in the wiring between the SL-R11 and E-STOP switch. 2. If the wiring insulation is damaged, replace it immediately. 3. Actually operate the E-STOP function and check to make sure the SL-R11's FSD output terminal turns off and that the machine stops. In addition, check the SL-R11 indicator and confirm that the LEDs for both E-STOP1 and E-STOP2 are off. 4. Reset the E-STOP switch. At this time, check that the FSD outputs are kept off. (The restart interlock function will automatically operate when the FSDs are turned off by the E-STOP even when the restart interlock function is not used.)

6

5. Use the restart input to reset the FSD output. At this time, if the SL-R11 goes to lockout condition and the FSD output is not recovered, there is probably a wiring problem or an E-STOP switch failure, etc., so immediately stop using the machine and make repairs. Absolutely do not use the machine until the repairs are completed.

6-2 Relay Circuit Board Replacement The output relay provided in the SL-R11 is designed to be user-replaceable, and there is no need to reconfigure the wire connections to the relay output terminal. This section explains how to replace the relay circuit board. 1. Prepare a replacement relay circuit board (OP-42372). 2. Turn off the power to the SL-R11. 3. Turn off the power to the devices connected to the SL-R11 FSD output terminal and AUX output terminal. 4. Remove the relay output terminal from the replacement relay board according to the instructions in section 4-2-1 “How to replace the relay output terminal block” (➮ page 4-2). 5. Refer to the figure below and remove the relay circuit board from the SL-R11.

English ENGLISH 6-1 6-2

Page 37

Chapter 6 Maintenance 6. Install the new relay circuit board in the SL-R11 and tighten the screws. (Recommended tightening torque is 0.6 N•m) 7. Attach the relay output terminal removed in Step 4 to the new replacement relay board according to the instructions in section 4-2-1 “How to replace the relay output terminal block (➮4-2)”. 8. Refer to “Chapter 5. Checklist” (➮ page 5-1) and check the operation.

WARNING

• A high voltage is generated in the FSD output and AUX output terminals, so before beginning the replacement work, turn off the power to the SL-C Series and SL-R11 as well as the power of the devices connected to the FSD output and AUX output terminals. Leaving the power on could result in electric shock. • When the relay needs to be replaced, replace it with the replacement relay circuit board (OP-42372) provided by KEYENCE. Do not use parts from another manufacturer. Using other parts could cause the SL-C to malfunction, and a serious accident causing a serious injury or death.

6

ENGLISH 6-2 6-3